  189   Wed Dec 12 22:24:48 2007 tobinFrogsPEMweather stationI poked at the weather station briefly this
evening.
  
  196   Tue Dec 18 16:50:35 2007 tobinUpdateSAFETYuvex laser safety glasses defectiveA few days ago we noticed what appeared to
be a blotched, speckled fracturing of the
coating of the "UVEX" laser safety glasses.
 bad-glasses.jpgbad-glasses-zoom.jpg 
  197   Tue Dec 18 21:31:31 2007 tobinUpdatePSLISS RINMy measurements of the ISS RIN via the SR785
and via the DAQ disagree considerably. The
spectral shapes are very similar, however,
 iss-rin.pdf 
  210   Fri Dec 21 20:32:25 2007 tobinUpdatePhotosGigE cameraI couldn't resist any longer: I plugged in
the Prosilica GC 750 GigE camera and took
it for a spin.  This is the little CMOS camera
 robs_desk.png 
  211   Sat Dec 22 00:52:57 2007 tobinConfigurationPSLISS surgeryIn an attempt to quell oscillations in the
(unused) outer loop portion of the ISS, I
shorted the "PD+" and "PD-" signals from
  
  212   Sat Dec 22 15:32:11 2007 tobinAoGEnvironmentantsAnts are everywhere: on the PSL table, on
the circuit board I'm soldering...  
 DSC_0361.JPG 
  219   Wed Jan 2 11:38:56 2008 tobinSummaryWIKI-40M Updatewiki spamOur wiki keeps getting spammed.  It turns
out that you can upload attachments without
a password, which is a bug.  I'll ask David
  
  231   Thu Jan 10 00:12:01 2008 tobinSummaryLockingDR[John, Tobin, Rana]

1.  We found SUS_BS_SENSOR_UL to have a ratty
  
  238   Mon Jan 14 23:11:26 2008 tobinConfigurationGeneralfiberJohn and I removed the fiber that ran from
the SP table to the cleanroom.  We plan to
build a MZ interferometer with this fiber
  
  239   Tue Jan 15 13:15:27 2008 tobinUpdateEnvironmentlots of noiseThey're throwing concrete around at the construction
site.
  
  243   Wed Jan 16 19:57:49 2008 tobinConfigurationPhotosISCT_EXHere's a photo of the ISCT_EX table, for the
purpose of planning our auxiliary laser arm
locking scheme.   Note the (undumped!) beam
 trx-annotated-small.jpg 
  247   Thu Jan 17 20:50:55 2008 tobinUpdateGeneralfiber couplingSam, John, and I matched the beam from an
NPRO into a fiber on the SP table today.
 In doing so we used our GigE camera for
  
  250   Fri Jan 18 20:53:56 2008 tobinConfigurationGeneralETMY oplevI monkeyed around with the ETMY oplev, adding
a folding mirror and moving the HeNe so that
John, Sam, and I have more room for our auxiliary
  
  253   Tue Jan 22 13:11:03 2008 tobinUpdateASCETMY oplev recenteredThe light wasn't even on the diode.   
  277   Sun Jan 27 13:13:21 2008 tobinMetaphysicsGeneraldepartureIt's been grand.  Thanks for having me!

GWAVES IN '08!
  
  498   Sun May 25 21:14:14 2008 tobinConfigurationComputersEPICS proxy serverI set up an EPICS gateway server on Nodus
so that we can look at 40m MEDM screens from
off-site.
  
  500   Tue May 27 16:24:54 2008 tobinConfigurationComputer Scripts / ProgramsndsproxyThe NDS Proxy is a program that accepts NDS
(LIGO Network Data Server) connections from
the internet and relays them to
  
  508   Fri May 30 21:30:15 2008 tobinConfigurationComputerssvn on solarisI installed svn on op440m.  This involved
installing the following packages from sunfreeware:
  
  510   Sun Jun 1 19:39:35 2008 tobinConfigurationComputerselog, etcPhil Ehrens gave me a DVD of the 40m elog,
apache, and (Jamie's) SVN archive.
I copied it to nodus:/home/controls/dvd-from-ehrens.
  
  513   Tue Jun 3 10:19:45 2008 tobinConfigurationComputersbig machineSeveral of us transported the big new awesome
Sun box from Bridge over to 
the 40m last week.  If I recall correctly,
  
  514   Tue Jun 3 10:40:27 2008 tobinConfigurationComputersnew dataviewerAlex let me know the secret location of the
latest dataviewer executable for Linux. 
It is:
  
  636   Sun Jul 6 16:17:40 2008 tobinHowToComputersSVNI was able to check out the 40m SVN here in
Livingston using this command:
  
  68   Tue Nov 6 14:51:03 2007 tobin, robUpdateIOOMode cleaner lengthUsing the Ward-Fricke variant* of the [url=http://ilog.ligo-wa.caltech.edu/ilog/pub/ilog.cgi?group=detector&date_to_view=02/14/2004&anchor_to_scroll_to=2004:02:15:00:06:50-daniel]Sigg-Frolov
method[/url], we found the length of the
mode cleaner to be [b]27.0934020183 meters[/b],
  
  16183   Fri Jun 4 17:46:25 2021 unYehonathanUpdateCDSOpto-isolator for c1auxeyI mounted the optoisolator on the DIN rail
and connected the 3 first channels
 20210604_173420.jpg 
  3038   Wed Jun 2 18:36:20 2010 valeraDAQCDSNoise generators in LSPAlex wrote a new code to implement LSP
noise generator. The code is based on 64
bit random number generator from Numerical
 noisegenerators.pdf 
  3048   Thu Jun 3 22:33:31 2010 valeraSummaryCDSsimulated plant work I put matlab files and a summary
into the 40m wiki for the fitting of the
40m Optickle transfer functions and generating
  
  3070   Fri Jun 11 22:09:58 2010 valeraHowToCDSfoton It appears that foton does not like
the unstable poles, which we need to model
the transfer functions.
  
  3074   Sun Jun 13 08:28:44 2010 valeraUpdateLocking40m Upgrade Optickle Model In my calculation of the digital
filters of the optical transfer functions
the carrier light is resonant in coupled
  
  3558   Sat Sep 11 22:42:07 2010 valeraUpdatePSLPSL update- The PMC REFL PD was moved from the temporary
location to the one called for by the PSL
layout (picture attached). The leakage beams
 DSC_2502.JPGDSC_2505.JPG 
  3560   Sun Sep 12 23:02:53 2010 valeraUpdate PMC mode matchingKiwamu and I found that the first lens
in the PMC mode matching telescope was mislabeled.
It is supposed to be PLCX-25.4-77.3-C and
 pmc.pdfpmc-abcd.tiff 
  3561   Sun Sep 12 23:16:52 2010 valeraUpdate FSS mode matchingThe attached plot shows the beam scans
of the beam leaking from the back mirror
of the PMC to the BS cube that first turns
 fss.pdffssaom-abcd.tifffssrc-abcd.tiff 
  3574   Wed Sep 15 01:58:28 2010 valeraUpdatePSLFSS lockingThe RefCav is locked and aligned. I changed
the fast gain sign by changing the jumper
setting on the TTFSS board. The RefCav visibility
 DSC_2510.JPG 
  3579   Wed Sep 15 19:29:13 2010 valeraSummary PSL power budget
    
        

            Location
  
  3580   Fri Sep 17 01:36:14 2010 valeraUpdate PMC line widthThe attached plots show the PMC cavity
line width measurement with 1 mW and 160
mW into the PMC. The two curves on each plot
 TEK00009.PNGTEK00010.PNG 
  3899   Thu Nov 11 18:05:55 2010 valeraUpdatePSLPMC mode matching at full laser power The
PMC mode matching was initially done at low
power ~150 mW. It was expected and found
 scan.pdfpmc2-abcd.png 
  3913   Sat Nov 13 16:57:21 2010 valeraConfigurationElectronicsPRM Side OSEM transimpedance changeNow that we have increased the range of
the AA to +/- 10 V I have increased the PRM
side OSEM transimpedance from 29 kV/A to
 PRM-SD-ADC.pdfPRM-SD-Current.pdf 
  3915   Sun Nov 14 11:56:59 2010 valeraUpdateCDSTest of ADC noise 
We missed
  
  3933   Tue Nov 16 15:32:18 2010 valeraUpdateElectronicsOSEM noise at the output of the satellite box I measured the SRM OSEM (no magnets
at the moment) noise out of the satellite
box with a SRS785 spectrum analyzer. I inserted
 osemnoise.pdf 
  4335   Tue Feb 22 00:18:47 2011 valeraConfiguration c1ioo and c1ass work and related fb crashes/restartsI have been editing and reloading the c1ioo
model last two days. I have restarted the
frame builder several times. After one of
  
  4339   Tue Feb 22 23:11:42 2011 valeraUpdate new medm screens: C1ASS.adl and C1MCASS.adl   C1MCASS.jpegC1ASS.jpeg 
  4345   Wed Feb 23 16:34:42 2011 valeraConfiguration pmc lens stagedI put the PMC last mode matching lens (one
between the steering mirrors) on a translation
stage to facilitate the PMC mode matching.
 PMCrefl.JPGP1070438.JPGP1070439.JPG 
  4355   Fri Feb 25 01:48:54 2011 valeraUpdateASCmc auto alignment status I made several scripts to handle
the mcass configuration and sensing measurements:
- The scripts and data are in the 
 mcditherlines.pdfmcdecenter.pdfmcmirror.pdf 
  4625   Wed May 4 13:51:51 2011 valeraConfiguration Intermittent MC3 UL PD signalThe attached plot shows the 30 day trend
of the MC3 UL PD signal. The signal dropped
to zero at some point but now it is close
 mc3ulpdmon.pdf 
  4629   Wed May 4 15:56:09 2011 valeraSummaryGeneralPSL and MC trendsThe attached plot shows 2 day trends of
the PMC and MC reflected and transmitted
power, the PSL POS/ANG QPD signals, and the
 pslmcdrift.pdf 
  4653   Fri May 6 15:42:55 2011 valeraMetaphysicsIOOInput mode cleaner length and 11 MHz modulation frequency After Kiwamu set the REFL11 phases
in the PRMI configuration (maximized PRM->REFL11I
reesponse) I tried to measure the MC length
  
  4659   Sat May 7 18:08:54 2011 valeraUpdateIOOMC beam spot centering scriptI tried to run the scripts/senseMCdecentering
to check the centering of the MC beam spots
on the mirrors. The script (csh) produces
 mcditherlines2.pdf 
  4660   Sun May 8 16:32:52 2011 valeraUpdateIOOMC beam spot centering Kiwamu told me that the CDS matrix
notation has changed and the 40m front end
code has changed since February. I changed
  
  4663   Mon May 9 09:37:51 2011 valeraUpdatePSLPSL and MC trendsThe attached plot shows 7 day trends of
the MC and PMC power levels, PSL QPDs, and
temperature. The MC stayed locked for ~40
 pslmcdrift2.pdf 
  4674   Tue May 10 00:44:52 2011 valeraUpdateIOOMC2 centeringKiwamu, Koji, Valera
We centered the beam on MC2 in pitch
by moving the MC1,2,3 in the following combination
 mc2centering.pdf 
  4685   Wed May 11 10:49:16 2011 valeraConfigurationElectronicsMC3 LL PD has no signalYesterday we found that MC3 OSEM LL PD
did not have a sensible signal - the readback
was close to zero and it was making MC move
  
ELOG V3.1.3-