ID |
Date |
Author |
Type |
Category |
Subject |
2402
|
Fri Dec 11 19:51:13 2009 |
Alberto | Configuration | LSC | 166 LO Disconnected |
Quote: |
Seems like very strange cable loss numbers. The Heliax is lossier than the RG-174? I wonder how these compare with the specs in the cable catalog?
|
In my last entry there was a typo for the measurement of the Heliax at 55 MHz. I corrected it. It was 1.084 dB instead of 1.084 dB/m.
For the Heliax I don't have the measurement of the loss per meter since I don't know the cable actual length.
Except for that, I checked the values I found on the Internet.
My measurements for the RG-174 seem comparable to the loss specified in the catalog ( here): 6.6dB in 100ft @ 55 MHz, that is 0.22 dB/m, that compare with 0.155 dB/m that I measured.
I did the measurement on a 4.33 meter long cable with SMA connectors at the ends. |
12948
|
Wed Apr 19 15:46:24 2017 |
gautam | Update | General | 1611/1811 inventory check |
I looked through the lab area to do a fast photodiode inventory check, as we may need to buy some for the higher order mode spectroscopy SURF project. I looked on the following optical tables: ETMY, ITMY, BS, AS, PSL, SP, ITMX, Jenne laser table, and ETMX, as well as the photodiode cabinet, and could only find two 1611s. Here is a summary of the inventory:
- Power supply 0901: 2x in photodiode cabinet (E6 along the Y arm), 1x on Jenne laser table
- Newfocus 1611 S/N 7284-WX, labelled "REF DET" on ITMY optical table, currently unused
- Newfocus 1611 S/N 57109 on Jenne laser table
I have not yet checked if these photodiodes are in working order.
|
4351
|
Thu Feb 24 17:42:00 2011 |
Aidan | Update | Green Locking | 15% of end laser sideband power transmitted through cavity |
I did a quick calculation to determine the amount of sideband transmission through the FP cavity.
The modulation frequency of the end PDH is 216kHz. The FSR of the cavity is about 3.9MHz. So the sidebands pick up about 0.17 radians extra phase on one round trip in the cavity compared to the carrier.
The ITM reflectance is r_ITM^2 = 98.5% of power, the ETM reflection is r_ETM^2 = 95%.
So the percentage of sideband power reflected from the cavity is R_SB = r_ITM*r_ETM*(exp(i*0.17) - 1)^2 / (1 - r_ETM*r_ITM exp(i*0.17) )^2 = 0.85 = 85%
So about 15% of the sideband power is transmitted through the cavity. The ratio of the sideband and carrier amplitudes at the ETM is 0.05
So, on the vertex PD, the power of the 80MHz +/-200kHz sidebands should be around sqrt(0.15)*0.05 = 0.02 = 2% of the 80MHz beatnote.
Once we get the green and IR locked to the arm again, we're going to look for the sidebands around the beatnote.
|
9618
|
Mon Feb 10 18:03:41 2014 |
jamie | Update | CDS | 12 core c1sus replacement |
I have configured one of the spare Supermicro X8DTU-F chassis as a dual-CPU, 12-core CDS front end machine. This is meant to be a replacement for c1sus. The extra cores are so we can split up c1rfm and reduce the over-cycle problems we've been seeing related to RFM IPC delays.
I pulled the machine fresh out of the box, and installed the second CPU and additional memory that Steve purchased. The machine seems to be working fine. After assigning it a temporary IP address, I can boot it from the front-end boot server on the martian network. It comes up cleanly with both CPUs recognized, and /proc/cpustat showing all 12 cores, and free showing 12 GB memory.
The plan is:
- pull the old c1sus machine from the rack
- pull OneStop, Dolphin, RFM cards from c1sus chassis
- installed OneStop, Dolphin, RFM cards into new c1sus
- install new c1sus back in rack
- power everything on and have it start back up with no problems
Obviously the when of all this needs to be done when it won't interfere with locking work. fwiw, I am around tomorrow (Tuesday, 2/11), but will likely be leaving for LHO on Wednesday. |
7513
|
Tue Oct 9 23:12:56 2012 |
Jenne | Update | LSC | 11MHz reconnected to EOM |
Riju hasn't been in the lab in a long time to do any measurements, so I put the signals back to how they should be.
I turned off / confirmed off the things which were sending signal to the EOM: the network analyzer, the RF generator box, and the Marconi which supplies the 11MHz.
I removed the cavity scanning cable, and terminated it, and put the regular 11MHz cable back on the splitter.
I then turned on the RF gen box and the Marconi. The Marconi had been off, so we were not getting any 11MHz or 55MHz out of the RF gen. box. This is why I couldn't lock any cavities last night (duh).
On to locking!
----------------- In other news,
While swapping out the EOM cable, I noticed that the DC power supply sitting under the POX table was supplying a weird value, 17 point something volts. I checked on the table to remind myself why that power supply is there...it's powering an RF amplifier right after the commercial PD that is acting as POP22. The amplifier wants +15 and GND, so I reset the power supply to 15V. We should add this to the list of things to fix, because it's dumb. Either we need to put in the real POP22 (long term goal), or we need to get this guy some rack power, and do the same for any amplifiers for the Beat setup. It's a little hoakey to have power supplies littering the lab. |
4530
|
Fri Apr 15 12:17:39 2011 |
kiwamu | Update | LSC | 11MHz demod board : funny I-Q phase |
During checking the 11MHz demod boards I found that the I-Q relative phase showed funny LO power dependence.
It is now under investigation.
In the plot above the green curve represents the I-Q phase of a 11MHz demod board (see here).
It showed a strong dependence on the LO power and it changes from -60 deg to -130 deg as the LO power changes.
This is not a good situation because any power modulation on the LO will cause a phase jitter.
For a comparison I also took I-Q relative phase of a 33MHz demod board, which hasn't been modified recently.
It shows a nice flat curve up to 5 dBm although it looks like my rough measurement adds a systematic error of about -5 deg.
- to do -
* check RF power in every point of LO path on the circuit
* check if there is saturation by looking at wave forms. |
4533
|
Fri Apr 15 15:15:08 2011 |
kiwamu | Update | LSC | 11MHz demod board : 90 degree splitter |
[Rana, Koji, Kiwamu]
Moreover the amplitude of the I and Q signals are highly unbalanced, depending on the LO power again.
This implies the coil for a 90 degree splitting won't work at 11 MHz since the coil is home made and used to be designed for a specific frequency (i.g. 24.5 MHz).
We decided to use a Mini circuit 90 deg splitter instead. Steve will order few of them soon and we will test it out.
Quote: |
During checking the 11MHz demod boards I found that the I-Q relative phase showed funny LO power dependence.
It is now under investigation.
|
|
4537
|
Sat Apr 16 02:00:14 2011 |
rana | Update | LSC | 11MHz demod board : 90 degree splitter |
One way to avoid some of the bad stuff in there is to take the 1 dBm input and amplify it to ~21 dBm before splitting and sending in to the Level 17 mixers.
One way to do this is by using the A3CP6025 from Teledyne-Cougar. Its an SMA connectorized amp which can put out 25 dBm and has a gain of 24 dB. We can just glue it onto the demod boards. Then we can remove the ERA-5 amplifiers and just use the broadband splitter as Kiwamu mentioned. |
2657
|
Thu Mar 4 22:07:21 2010 |
rana | Update | 40m Upgrading | 11MHz PD not yet designed |
Use 10 Ohms for the resistance - I have never seen a diode with 25 Ohms.
p.s. PDFs can be joined together using the joinPDF command or a few command line options of 'gs'. |
2656
|
Thu Mar 4 19:53:56 2010 |
Alberto | Update | 40m Upgrading | 11MHz PD designed adjusted for diode's resistance; 55 MHz RFPD designed |
I read a few datasheets of the C30642GH photodiode that we're going to use for the 11 and 55 MHz. Considering the values listed for the resistance and the capacitance in what they define "typical conditions" (that is, specific values of bias voltage and DC photocurrent) I fixed Rd=25Ohms and Cd=175pF.
Then I picked the tunable components in the circuit so that we could adjust for the variability of those parameters.
Finally with LISO I simulated transfer functions and noise curves for both the 11 and the 55MHz photodiodes.
I'm attaching the results and the LISO source files.
|
Attachment 1: rfpd55_Noise.pdf
|
|
Attachment 2: rfpd55_TF.pdf
|
|
Attachment 3: rfpd11_v2_TF.pdf
|
|
Attachment 4: rfpd11_v2_Noise.pdf
|
|
Attachment 5: rfpd11_v2.fil
|
Attachment 6: rfpd55.fil
|
6590
|
Mon Apr 30 22:58:57 2012 |
Jenne | Update | Electronics | 11MHz Marconi set to default after power outage |
After a power outage, a Marconi comes back to it's defaults. It needed to be reset to the values in elog 5530. I'm putting a label on the Marconi so we don't have to look it up next time.
Before fixing the Marconi, POY11, AS11 and AS55 all looked like noise, no real signals, even though the arm is flashing. Now they all look PDH-y, so things are better. |
11230
|
Tue Apr 21 11:55:05 2015 |
Steve | Update | Optical Levers | 1103P noise measurement |
Manasa and Steve,
Is this what you want? Dashed lines are dark.
BS and PRM oplevs are blocked for this measurement. I will restore to normal operation at 4pm today.
|
Attachment 1: 1103P@qpdBS.jpg
|
|
Attachment 2: oplev1103P.png
|
|
Attachment 3: oplevSum1103Pbs.png
|
|
11231
|
Tue Apr 21 15:03:27 2015 |
rana | Update | Optical Levers | 1103P noise measurement |
It doesn't work with the lens in there, but it seems pretty close. Please leave it as is and I'll play with it after 5 today. |
11232
|
Tue Apr 21 21:46:34 2015 |
rana | Update | Optical Levers | 1103P noise measurement |
To test what the inherent angular noise of the HeNe 1103P laser is, we're testing it on a table pointing into the BS OL QPD with only a few steering mirrors.
From the setup that I found today, I've removed the lens nearest to the laser (which was used for the BS and PRM) as well as the ND filter (what was this for?) and the lens placed just before the BS QPD.
With the ND filter removed, the quadrant signals are now ~15000 if we misalign it and ~9000 each with the beam centered.
In order to calibrate the OLPIT_IN1 and OLYAW_IN1 signals into mm of beam motion, I misaligned the mirror just before the QPD. The knobs on there actuate the 100 TPI screws and the knurling on the knob itself has 10 ridges, so that's 36 deg per bump.
Pit Knob (deg) |
OLPIT |
Yaw Knob (deg) |
OLYAW |
0 |
29 |
0 |
-36 |
45 |
13 |
36 |
-16 |
90 |
-16 |
72 |
19 |
135 |
-39 |
108 |
36 |
|
|
|
|
PIT cal ~ 1.55 (knob deg / count) -->> 10 microns / count --->>> 10 urad / count
YAW cal ~ 1 (knob deg / count) -->> 6.5 microns / count --->>> 6.5 urad / count
Distance from the 45 deg turning mirror to the QPD silicon surface is 23 cm. Distance between knob tip and fixed pivot point is ~4 cm. 1 knob turn = 0.01" = 0.254 mm = 0.254/40 radians of mirror angle.
So 360 deg of knob gives 2*0.254/40 = 0.012 radians of beam angle = 0.012 * 230 mm ~2.3 mm of beam spot motion. Or 6.4 microns of translation / deg of knob.
The distance from the face of the laser to the QPD is 96 cm.
The punchline is that the laser shows a level of noise which has a similar shape to what's seen at LLO, but 10x lower.
The noise at 0.05 - 0.2 Hz is ~2-3x worse than the PR3 at LLO. Not sure if this is inherent to the HeNe or the wind in our setup. |
Attachment 1: oplev1103P.png
|
|
Attachment 2: L1-ISI_SUS_ODC_FC496F_SPECTRUM-1113523216-86400.png
|
|
9072
|
Tue Aug 27 18:21:35 2013 |
Jenne | Configuration | Electronics | 110 MHz LO options |
As I see it, we have a few options for getting the 110 MHz LO to both the POP110 and AS110 demod boards.
The current situation is described by Kiwamu in elog 5746. The 55 MHz signal comes into the box, and is split 4 ways, with each path having 19.7 dBm. One of these 4 is for 110. It has a 2dB attenuator (giving us ~17.7 dBm), and then it goes to an MK-2 frequency multiplier. I'm a little lost on why we're giving the MK-2 17 dBm, since it says that it can handle an input power between 1 - 15 dBm. It has ~16 dB conversion loss, so the 110 output of the distribution board has (according to the drawing) 1.9 dBm. The demod boards have a 10 dB attenuator as the first element on the LO path, so we're giving the ERA-5 -8 dBm.
We can either amplify the 110 leaving the distribution box, split it, and then attenuate it to the appropriate level for the demod boards, or we can change the attenuators on the POP110 and AS110 demod boards.
Since we seem to be over driving the 2x frequency multiplier, I think I should change the 2dB attenuator to a 5dB attenuator, so we're giving the 2x multiplier ~15 dBm. The conversion loss of ~16 dB means we'll have -1 dBm of 110 MHz. I want to amplify that by ~10 dB, to give 9 dBm. Attenuate by 5 dB to get to 4 dBm, then split into 2, giving me 2 110 MHz spigots, each of ~1 dBm. Since the demod boards expect between 0-2 dBm for the LO's, this should be just fine.
Thoughts, before I start scrounging parts, and pulling the RF distribution box? |
9073
|
Tue Aug 27 18:58:52 2013 |
Koji | Configuration | Electronics | 110 MHz LO options |
- Do we have an appropriate amplifier?
- True challenge could be to find a feedthrough for the new port. (or to find a space for the amplifier in the box)
- PDXXX channels is on the DC whitening filter module. There could be some modification on this module (like diabling the whitening gain selector).
- We don't have AS11 and AS165, and so far it is unlikely to use AS11. i.e. The feedthrough, the slot on the crate, the whitening, and the channels can be trasnsition from 11 to 110.
Quote: |
I want to amplify that by ~10 dB, to give 9 dBm. Attenuate by 5 dB to get to 4 dBm, then split into 2, giving me 2 110 MHz spigots, each of ~1 dBm.
Thoughts, before I start scrounging parts, and pulling the RF distribution box?
|
|
7360
|
Fri Sep 7 12:28:09 2012 |
Koji | Update | LSC | 11&55MHz modulations turned off |
11MHz modulation source was turned off (disabled) at Marconi at 12:00. |
845
|
Mon Aug 18 09:19:55 2008 |
steve | Summary | VAC | 11 days at atm |
It took 11 days to fix earth quake triggered sus problems of ITMX, SRM and PRM
Only ITMX north and BSC north vac doors were removed.
The PRM sus had to be removed form the vac envelope for "hip replacement"-new wire stand off was
epoxied in place.
Note: the PRM has no guide rod on the other side
ITMX, SRM and BS osems were optimized in place.
No crosscoupling optimization was performed.
Beam block was removed from ITMXC, it was too close to the main beam.
POX pick off mirror and mount will be replaced next vent.
Vac viewports were inspected from the inside. |
Attachment 1: ventprm.jpg
|
|
7515
|
Wed Oct 10 02:15:14 2012 |
rana | Update | LSC | 11 MHz reconnected to EOM |
Absolutely hokey. What are our requirements for this RFPD? What are the power levels and SNR that we want (I seem to remember that its for 22 as well as 110 MHz)? Perhaps we can test an aLIGO one if Rich has one sitting around, or if the aLIGO idea is to use a broadband PD I guess we can just keep using what we have. |
2653
|
Wed Mar 3 18:32:25 2010 |
Alberto | Update | 40m Upgrading | 11 MHz RFPD elctronics |
** Please add LISO file w/ component values.
I designed the circuit for one of the 11 MHz photodiodes that we're going to install in the 40m Upgrade.
This is a simple representation of the schematic:
gnd # | # Cw2 # | # n23 # | # Lw2 # | # n22 # | # Rw2 # | |\ # n2- - - C2 - n3 - - - - | \ # | | | | |4106>-- n5 - Rs -- no # iinput Rd L1 L2 R24 n6- | / | | # nin - | | | | | |/ | Rload # Cd n7 R22 gnd | | | # | | | | - - - R8 - - gnd # gnd R1 gnd R7 # | | # gnd gnd # # #
I chose the values of the components in a realistic way, that is using part available from Coilcraft or Digikey.
Using LISO I simulated the Tranfer Function and the noise of the circuit.
I'm attaching the results.
I'll post the 55MHz rfpd later. |
Attachment 1: rfpd11_v2_TF.pdf
|
|
Attachment 2: rfpd11_v2_Noise.pdf
|
|
2655
|
Thu Mar 4 08:43:35 2010 |
Alberto | Update | 40m Upgrading | 11 MHz RFPD elctronics |
Quote: |
** Please add LISO file w/ component values.
|
oops, forgotten the third attachment...
here it is |
Attachment 1: rfpd11_v2.fil
|
# Resonant RF diode front end
#
# gnd
# |
# Cw2
# |
# n23
# |
# Lw2
# |
... 60 more lines ...
|
12949
|
Fri Apr 21 13:59:47 2017 |
Eric Gustafson | Summary | | 1064 nm Semiconductor Laser Fiber Distribution System and Mirror Tomography |
1064 nm Semiconductor Laser Fiber Distribution System and Mirror Tomography
Below threshold these Semiconductor Fabry-Perot lasers have an axial mode structure with a spacing of about a THz. As you turn up the current to above threshold the first mode to oscillate saturates the gain down on all the modes and only it oscillates. The laser I have here in my office (a backup for the one you have at the 40 meter) has a wavelength of 1064.9 nm at 70 Degrees C. We should be able to temperature tune it down to 1064.3 nm although this could be a bit tedious the first time we do it. The specifications claim a "spectrum width" of 1.097 nm which I believe is the temperature tuning range. I don’t know what the line width is but it will be single frequency and we shouldn’t have mode hoping problems. So we should be able to use it in the “Mirror Tomography” experiment. You might want to use some sort of polarization diversity to avoid the problems of fiber polarization drift.
There have been 2 student projects on using the fiber distributed PD frequency response at1064 nm laser.
“Automated Photodiode Frequency Response Measurement System,” Alexander Cole - T1300618
“Final Report: Automated Photodiode Frequency Response Measurement System for Caltech 40m lab,” Nichin Sreekantaswamy - P140021
I’ll look up a few more references and add include them in the next elog.
Eric
|
9253
|
Fri Oct 18 08:12:08 2013 |
Steve | Update | PEM | 1000 days trends |
|
Attachment 1: trend1000days.png
|
|
1640
|
Mon Jun 1 19:19:26 2009 |
rana | Update | PSL | 1000 days of hour-trend |
|
Attachment 1: u.png
|
|
9482
|
Tue Dec 17 20:59:23 2013 |
Jenne | Update | LSC | 1/sqrt(TR) signals added to frames |
I noticed that we have not been saving the 1/sqrt(TRX) and 1/sqrt(TRY) data, so I modified the c1lsc model and added them to the DAQ channels block. I restarted the c1lsc model, and the _DQ channels are now archived. |
3171
|
Wed Jul 7 19:41:27 2010 |
Jenne | Update | SUS | 1.5 more ECD sets suspended for tip tilts |
[Jenne, Kyung Ha]
We made some good progress on suspending the Tip Tilt ECDs today. We finished one whole set, plus another half. The half is because one of the screw holes on the lower right ECD somehow got cross threaded. The ECD and screws in question were separately wrapped in foil to mark them as iffy. We'll redo that second half tomorrow. This makes a total of 2.5 (including yesterday's work) ECD backplanes suspended. The only thing left for these ones is to trim up the excess wire.
We also (with Koji) took a look at the jig used for suspending the mirror holder. It looks like it was designed for so many Tip Tilt generations ago as to be basically useless for the 40m TTs. The only really useful thing we'll get out of it is the distance between the suspension block and the mirror holder clamps. Other than that we'll have to make do by holding the mirror and block at the correct distance apart, utilizing a ruler, calipers, or similar. Rana pointed out that we should slightly bend the blade springs up a bit, so that when they are holding the load of the mirror holder, they sit flat.
Attached below are 2 different pictures of one of the ECD backplane sets that has been suspended. One with black background to illustrate the general structure, and one with foil background to emphasize the wires. |
Attachment 1: ECDbackplane_blackdump_small.jpg
|
|
Attachment 2: ECDbackplane_foil_small.jpg
|
|
8008
|
Wed Feb 6 14:51:25 2013 |
Jenne | Update | Electronics | 1 power supply replaced! |
Quote: |
Currently, DC power for amplifiers ZHL-1000LN+ is supplied by Aligent E3620A.
I tried to use power supply from the side of 1X1 rack, but fuse plug(Phoenix Contact ST-SI-UK-4) showed red LED, so I couldn't use it.
|
Yuta, Jenne
We fixed things so that we are now using regular fused rack power for these amplifiers. The fuse no longer had a red LED, but it measured open when we checked the resistance. Although, somehow (magic?) 13.73V were getting to the other side of the fuse.
Anyhow, replacing the fuse with a new one fixed the problem right up. |
6496
|
Fri Apr 6 15:06:05 2012 |
Den | Update | IOO | 1 Hz resonance |
I think we can try to damp 1 Hz resonance more. In September it was not seen because of the digital noise. After we've figured it out, 1 Hz resonance began to be more clear (blue line).

Now applying oaf we reduce the effect of the stack and the 1 Hz resonance is even more clear:

|
7234
|
Mon Aug 20 13:02:57 2012 |
Den | Update | Adaptive Filtering | 1 Hz resonance |
Static filter was adjusted to filter 1 Hz resonance in MCL and it could do it. Stack is not great in this experiment due to the phase mismatch. I'll fix it.

|
11986
|
Thu Feb 11 14:28:50 2016 |
Steve | Update | Treasure | 091415 declared |
Beautifully Done
Chirp
what is next?
Atm 3, Ron Drever could not celebrate with us because of health issues.
|
Attachment 1: 091415declared.jpg
|
|
Attachment 2: You_were_right!.jpg
|
|
Attachment 3: P1080312.JPG
|
|
9042
|
Tue Aug 20 16:23:41 2013 |
rana | Summary | General | /home/cds nearly full |
/home/cds is >98% full - below are some of the usage numbers:
controls@rosalba:/users/OLD 0$ du -h --max-depth=1
42M ./katrin
1.5M ./ben
2.4M ./sanjit
569M ./waldman
328M ./sonia
3.6G ./lsinger
44M ./dbusby
105M ./dbarron
21M ./manuel
709M ./yaakov
46M ./rodionov
240M ./ishwita
2.7G ./clara
56M ./gopal
290M ./mashaB
87M ./varvella
5.6M ./Sascha
2.9G ./ryan
190M ./nancy
3.5G ./john
269M ./elizabeth.davison
165M ./jweiner
460K ./mjones
49M ./stephanie
52M ./mohana
56M ./noriyasu
38M ./mjenson
76M ./sballmer
224M ./kirk
812K ./bonnie
33M ./janosch
16M ./kevin
122M ./dblair
2.6G ./mirko
389M ./keenan
195M ./tf
150M ./littlezach
193M ./jmiller
1.8G ./ting
131M ./dmalling
842M ./sharmila
1.4G ./caryn
12G ./rward
4.1M ./jay
443M ./emintun
184M ./katharine
76K ./nick
804K ./nicole.ing
14M ./jenny
542M ./vsanni
45M ./peter
7.8G ./miyakawa
4.8M ./channa
4.0K ./frank
9.9G ./razib
35M ./amin
361M ./sharon
62M ./bram
3.9M ./volodya
7.9M ./larisa
301M ./sasha
33M ./eric.hendries
18M ./vuk
101M ./huan
1.8M ./sonali
453M ./megan
43M ./Royal
5.4G ./ayaka
19M ./mott
518M ./justing
501M ./avi
173M ./kakeru
3.9G ./alberto
41M ./paul.fulda
59M ./elena
67G .
controls@rosalba:/opt/rtcds/userapps 0$ du -h --max-depth=1
1.4G ./tags
13M ./trunk.bak
40K ./.svn
3.0G ./trunk
174M ./trunk.bak2
4.2G ./branches
8.7G .
linux1:cds>nice du -h --max-depth=1
du: `./llo/chans/daq/archive': Permission denied
du: `./llo/chans/daq/old': Permission denied
707M ./llo
9.7M ./mit~
752K ./raidwebFirmware
462M ./epics
2.1G ./tmp
1.5G ./gds
76M ./project
9.1G ./ligo
449G ./rtcds
3.3G ./apps
20K ./.kde
512K ./cdscfg
1.4M ./.Trash-controls
5.8M ./scripts
20K ./.TemporaryItems
964G ./caltech
71M ./bin
16K ./.Trash-1001
4.5G ./rtapps
564M ./src
11M ./vw
3.8M ./dvSave
460M ./lho
1.2G ./data
1.5T . |
9045
|
Wed Aug 21 17:42:03 2013 |
rana | Summary | General | /home/cds nearly full |
One of the reasons that our disk is getting full is due to the scripts_archive directory. A backup script runs on op340m and makes a tar.bz2 file of the scripts directory and puts it in scripts_archive every morning at 6 AM.
On Oct 7, 2011, Koji fixed this script to point at our new scripts directory instead of the old /cvs/cds/caltech/scripts directory. Since then, however, no one has fixed the exclude file to NOT back up the junk that's in that directory. Its a 1.6 GB directory so its full of it.
I've deleted a bunch of junk from the scripts directory: this directory is for scripts, not for your personal home movies or junk data files. Put those in your USER directory. Put temporary data files in /tmp/. I've also added a few more patterns to the exclude file so that less .mpg, .png, .pdf, .dat, etc get stored every day. The new daily .tar.bz2 file wil be ~25 MB instead of 770 MB.
(also fixed the backup script to use 'env' to setup the perl environment and removed the hard-coded path to tar) |
9147
|
Fri Sep 20 20:14:52 2013 |
rana | Summary | General | /home/cds nearly full |
Quote: |
One of the reasons that our disk is getting full is due to the scripts_archive directory. A backup script runs on op340m and makes a tar.bz2 file of the scripts directory and puts it in scripts_archive every morning at 6 AM.
On Oct 7, 2011, Koji fixed this script to point at our new scripts directory instead of the old /cvs/cds/caltech/scripts directory. Since then, however, no one has fixed the exclude file to NOT back up the junk that's in that directory. Its a 1.6 GB directory so its full of it.
I've deleted a bunch of junk from the scripts directory: this directory is for scripts, not for your personal home movies or junk data files. Put those in your USER directory. Put temporary data files in /tmp/. I've also added a few more patterns to the exclude file so that less .mpg, .png, .pdf, .dat, etc get stored every day. The new daily .tar.bz2 file wil be ~25 MB instead of 770 MB.
(also fixed the backup script to use 'env' to setup the perl environment and removed the hard-coded path to tar)
|
OUr disk was getting full again. Turned out my "fix" to 25 MB was only a fix to 250 MB. Since we were getting disk full warnings on our Ubuntu workstations, I deleted some COMSOL.dmg files from users/zach/ and then started deleting every other tarball from the scripts_archive directory. ~221 GB are now free. Still need to fix the exclude file for scripts better. |
9535
|
Tue Jan 7 23:50:27 2014 |
jamie | Update | CDS | /frames space cleared up, daqd stabilized |
The wiper script is done and deleted a whole bunch of stuff to clean up some space:
controls@fb ~ 0$ /opt/rtcds/caltech/c1/target/fb/wiper.pl --delete
Tue Jan 7 23:09:21 PST 2014
Directory disk usage:
/frames/trend/minute_raw 385927520k
/frames/trend/second 125729084k
/frames/full 12552144324k
/frames/trend/minute 2311404k
Combined 13066112332k or 12759875m or 12460Gb
/frames size 13460088620k at 97.07%
/frames above keep value of 95.00%
Frame area size is 12401156668k
/frames/full size 12552144324k keep 11781098835k
/frames/trend/second size 125729084k keep 24802313k
/frames/trend/minute size 2311404k keep 620057k
Deleting some full frames to free 771045488k
- /frames/full/10685/C-R-1068567600-16.gwf
- /frames/full/10685/C-R-1068567616-16.gwf
...
controls@fb ~ 0$ df -h /frames
Filesystem Size Used Avail Use% Mounted on
/dev/sda1 13T 12T 826G 94% /frames
controls@fb ~ 0$
So it cleaned up 826G of space. It looks like the fb is stabilized for the moment. On site folks should confirm...
asdfasdfsadf sadf asdf |
9949
|
Tue May 13 17:45:21 2014 |
rana | Update | CDS | /frames space cleared up, daqd stabilized |
Late last night we were getting some problems with DAQD again. Turned out to be /frames getting full again.
I deleted a bunch of old frame files by hand around 3AM to be able to keep locking quickly and then also ran the wiper script (target/fb/wiper.pl).
controls@pianosa|fb> df -h; date
Filesystem Size Used Avail Use% Mounted on
/dev/sda1 440G 9.7G 408G 3% /
none 7.9G 288K 7.9G 1% /dev
none 7.9G 464K 7.9G 1% /dev/shm
none 7.9G 144K 7.9G 1% /var/run
none 7.9G 0 7.9G 0% /var/lock
none 7.9G 0 7.9G 0% /lib/init/rw
none 440G 9.7G 408G 3% /var/lib/ureadahead/debugfs
linux1:/home/cds 1.8T 1.4T 325G 82% /cvs/cds
linux1:/ligo 71G 18G 50G 27% /ligo
linux1:/home/cds/rtcds
1.8T 1.4T 325G 82% /opt/rtcds
fb:/frames 13T 12T 559G 96% /frames
linux1:/home/cds/caltech/users
1.8T 1.4T 325G 82% /users
Tue May 13 17:35:00 PDT 2014
Looking through the directories by hand it seems that the issue may be due to our FB MXstream instabilities. The wiper looks at the disk usage and tries to delete just enough files to keep us below 95% full for the next 24 hours. If, however, some of the channels are not being written because some front ends are not writing their DAQ channels to frames, then it will misestimate the disk size. In particular, if its currently writing small frames and then we restart the mxstream and the per frame file size goes back up to 80 MB, it can make the disk full.
For now, I have modified the wiper.pl script to try to stay below 93%. As you can see by the above output of 'df', it is already above 96% and it still has files to write until the next run of wiper.pl 7 hours from now at. at 6 AM.
IF we assume that its writing a 75MB file every 16 seconds, then it would write 405 GB of frames every day. There is 559 GB free right now so we are OK for now. With 405 GB of usage per day, we have a lookback of ~12TB/405GB ~ 29 days (ignoring the trend files). |
9955
|
Thu May 15 01:42:07 2014 |
rana | Update | CDS | /frames space cleared up, daqd stabilized |
Script seems to be working now:
nodus:~>df -h | grep frames
fb:/frames 13T 12T 931G 93% /frames
|
9531
|
Tue Jan 7 23:08:01 2014 |
jamie | Update | CDS | /frames is full, causing daqd to die |
Quote:
|
The daqd process is segfaulting and restarting itself every 30 seconds or so. It's pretty frustrating.
Just for kicks, I tried an mxstream restart, clearing the testpoints, and restarting the daqd process, but none of things changed anything.
Manasa found an elog from a year ago (elog 7105 and preceding), but I'm not sure that it's a similar / related problem. Jamie, please help us
|
The problem is not exactly the same as what's described in 7105, but the symptoms are so similar I assumed they must have a similar source.
And sure enough, /frames is completely full:
controls@fb /opt/rtcds/caltech/c1/target/fb 0$ df -h /frames/
Filesystem Size Used Avail Use% Mounted on
/dev/sda1 13T 13T 0 100% /frames
controls@fb /opt/rtcds/caltech/c1/target/fb 0$
So the problem in both cases was that it couldn't write out the frames. Unfortunately daqd is apparently too stupid to give us a reasonable error message about what's going on.
So why is /frames full? Apparently the wiper script is either not running, or is failing to do it's job. My guess is that this is a side effect of the linux1 raid failure we had over xmas. |
9533
|
Tue Jan 7 23:13:47 2014 |
jamie | Update | CDS | /frames is full, causing daqd to die |
Quote: |
So why is /frames full? Apparently the wiper script is either not running, or is failing to do it's job. My guess is that this is a side effect of the linux1 raid failure we had over xmas.
|
It actually looks like the wiper script has been running fine. There is a log from Tuesday morning:
controls@fb ~ 0$ cat /opt/rtcds/caltech/c1/target/fb/wiper.log
Tue Jan 7 06:00:02 PST 2014
Directory disk usage:
/frames/trend/minute_raw 385289132k
/frames/trend/second 100891124k
/frames/full 12269554048k
/frames/trend/minute 1906772k
Combined 12757641076k or 12458633m or 12166Gb
/frames size 13460088620k at 94.78%
/frames is below keep value of 95.00%
Will not delete any files
df reported usage 97.72%
controls@fb ~ 0$
So now I'm wondering if something else has been filling up the frames today. Has anything changed today that might cause more data than usual to be written to frames?
I'm manually running the wiper script now to clear up some /frames. Hopefully that will solve the problem temporarily. |
12796
|
Fri Feb 3 11:40:34 2017 |
ericq | Summary | CDS | /cvs/cds/caltech/chans back on svn1.6 |
I was able to bring back svn 1.6 formatting to /cvs/cds/caltech/chans by doing the following on nodus:
cd /cvs/cds/caltech
mkdir newchans
cd newchans
svn co https://nodus.ligo.caltech.edu:30889/svn/trunk/chans ./
rm -rf ../chans/.svn
mv ./.svn ../chans/
Note that I used the http address for the repository. The svn repository doesn't live at file:///cvs/cds/caltech/svn anymore; all of our checkouts (e.g. in the scripts directory) use http to get the one true repo location, regardless of where it lives on nodus' filesystem. (I suppose we could also use https://nodus.martian:30889/svn to stick to the local network, but I don't think we're that limited by the caltech network speed)
Presumably, at some point we will want to introduce a newer operating system into the 40m, as ubuntu 12.04 hits end-of-life in April 2017. Ubuntu 16.04 includes svn 1.8, so we'll also hit this issue if we choose that OS.
Aside from the svn issues, this directory (/cvs/cds/caltech/chans ) only contains pre-2010 channels. Filters and DAQ ini files currently live in /opt/rtcds/caltech/c1/chans , which is not under version control. It's also not clear to me why summary page configurations should be kept in this /cvs/cds place. |
12797
|
Sat Feb 4 12:00:59 2017 |
rana | Summary | CDS | /cvs/cds/caltech/chans back on svn1.6 |
True - its an issue. Koji and I are updating zita into Ubuntu16 LTS. If it looks like its OK with various tools we'll swap over the others into it. Until then I figure we're best off turning allegra back into Ubuntu12 to avoid a repeat of this kind of conflict. Once the workstations in the LLO control room are running smoothly on a new OS for a year, we can transfer into that. I don't think any of us wants to be the CDS beta tester for DV or DTT. |
12798
|
Sat Feb 4 12:20:39 2017 |
jamie | Summary | CDS | /cvs/cds/caltech/chans back on svn1.6 |
Quote: |
True - its an issue. Koji and I are updating zita into Ubuntu16 LTS. If it looks like its OK with various tools we'll swap over the others into it. Until then I figure we're best off turning allegra back into Ubuntu12 to avoid a repeat of this kind of conflict. Once the workstations in the LLO control room are running smoothly on a new OS for a year, we can transfer into that. I don't think any of us wants to be the CDS beta tester for DV or DTT.
|
Just to be clear, since there seems to be some confusion, the SVN issue has nothing to do with Debian vs. Ubuntu. SVN made non-backwards compatible changes to their working copy data format that breaks newer checkouts with older clients. You will run into the exact same problem with newer Ubuntu versions.
I recommend the 40m start moving towards the reference operating systems (Debian 8 or SL7) as that's where CDS is moving. By moving to newer Ubuntu versions you're moving away from CDS support, not towards it. |
12799
|
Sat Feb 4 12:29:20 2017 |
jamie | Summary | CDS | /cvs/cds/caltech/chans back on svn1.6 |
No, not confused on that point. We just will not be testing OS versions at the 40m or running multiple OS's on our workstations. As I've said before, we will only move to so-called 'reference' systems once they've been in use for a long time.
Quote: |
Quote: |
True - its an issue. Koji and I are updating zita into Ubuntu16 LTS. If it looks like its OK with various tools we'll swap over the others into it. Until then I figure we're best off turning allegra back into Ubuntu12 to avoid a repeat of this kind of conflict. Once the workstations in the LLO control room are running smoothly on a new OS for a year, we can transfer into that. I don't think any of us wants to be the CDS beta tester for DV or DTT.
|
Just to be clear, since there seems to be some confusion, the SVN issue has nothing to do with Debian vs. Ubuntu. SVN made non-backwards compatible changes to their working copy data format that breaks newer checkouts with older clients. You will run into the exact same problem with newer Ubuntu versions.
I recommend the 40m start moving towards the reference operating systems (Debian 8 or SL7) as that's where CDS is moving. By moving to newer Ubuntu versions you're moving away from CDS support, not towards it.
|
|
12800
|
Sat Feb 4 12:50:01 2017 |
jamie | Summary | CDS | /cvs/cds/caltech/chans back on svn1.6 |
Quote: |
No, not confused on that point. We just will not be testing OS versions at the 40m or running multiple OS's on our workstations. As I've said before, we will only move to so-called 'reference' systems once they've been in use for a long time.
|
Ubuntu16 is not to my knowledge used for any CDS system anywhere. I'm not sure how you expect to have better support for that. There are no pre-compiled packages of any kind available for Ubuntu16. Good luck, you big smelly doofuses. Nyah, nyah, nyah. |
12914
|
Tue Mar 28 21:06:53 2017 |
rana | Summary | CDS | /cvs/cds/caltech/chans back on svn1.6 |
Debian doesn't like EPICS. Or our XY plots of beam spots...Sad!
Quote: |
Quote: |
No, not confused on that point. We just will not be testing OS versions at the 40m or running multiple OS's on our workstations. As I've said before, we will only move to so-called 'reference' systems once they've been in use for a long time.
|
Ubuntu16 is not to my knowledge used for any CDS system anywhere. I'm not sure how you expect to have better support for that. There are no pre-compiled packages of any kind available for Ubuntu16. Good luck, you big smelly doofuses. Nyah, nyah, nyah.
|

|
1059
|
Mon Oct 20 15:02:00 2008 |
Yoichi | Configuration | Computers | /cvs/cds restored |
I moved missing files in /cvs/cds restored by Alan and Stuart to the original locations.
I confirmed autoburt runs, and dtt, which had also been having trouble running, runs ok now.
I found an interesting piece of evidence on allegra, our new 64bit linux machine.
In the Trash of controls Desktop on that machine, there is /cvs/cds/vw/ directory.
I remember that when I last time emptied the trash bin on the machine (yesterday), it took somewhat long time.
Too bad that I did not pay attention to what was actually in the Trash, but now I have a feeling that in the Trash were
missing /cvs/cds/* directories.
While emptying the Trash, I encountered several errors saying permission denied or something like that, and skipped those files.
Sometimes, when you move something from NFS mounted directories to the Trash, you get this kind of errors.
So my guess is that someone accidentally (or intentionally) moved /cvs/cds/* except for "caltech" to the Trash of allegra.
And I completely removed them carelessly. |
1060
|
Mon Oct 20 16:18:00 2008 |
Alan | Configuration | Computers | /cvs/cds restored |
Quote: | I moved missing files in /cvs/cds restored by Alan and Stuart to the original locations.
I confirmed autoburt runs, and dtt, which had also been having trouble running, runs ok now.
I found an interesting piece of evidence on allegra, our new 64bit linux machine.
In the Trash of controls Desktop on that machine, there is /cvs/cds/vw/ directory.
I remember that when I last time emptied the trash bin on the machine (yesterday), it took somewhat long time.
Too bad that I did not pay attention to what was actually in the Trash, but now I have a feeling that in the Trash were
missing /cvs/cds/* directories.
While emptying the Trash, I encountered several errors saying permission denied or something like that, and skipped those files.
Sometimes, when you move something from NFS mounted directories to the Trash, you get this kind of errors.
So my guess is that someone accidentally (or intentionally) moved /cvs/cds/* except for "caltech" to the Trash of allegra.
And I completely removed them carelessly. |
In the meantime, I have re-started the nightly backup for /frames/minute-trends
but NOT YET for /cvs/cds ,
since I fear that we'll find another problem and will need to go back to the June 27 backup.
Let's wait a few days for the dust to settle,
and if everyone feels confident that /cvs/cds is ok,
I'll restart the backup of that.
How I restored the files, for the record:
Stuart mounted /archive/backup onto an accessible computer (garrak.ligo.caltech.edu ) and I logged on to controls@nodus and ran this command:
/cvs/cds/caltech/scripts/backup/rsync --rsync-path=/usr/bin/rsync --rsh=/usr/bin/ssh --compress --verbose --archive --hard-links --exclude=caltech/ ajw@garrak.ligo.caltech.edu:/backup/40m/cvs /cvs/cds/recover_20081020
I had to type in my GC password, and it ran for ~20 minutes (would have been much longer had I asked for /cvs/cds/caltech as well!).
you can view the backups by logging on to garrak.ligo.caltech.edu with your GC account:
/backup/40m/cvs/cds/
/archive/frames/trend/minute-trend/40m |
13929
|
Thu Jun 7 20:21:15 2018 |
Koji | Update | Computer Scripts / Programs | /cvs/cds Backup in danger |
Local backup on chiara seems not working since Nov 19, 2017.
/opt/rtcds/caltech/c1/scripts/backup/localbackup.log
2017-11-18 07:00:01,504 INFO Updating backup image of /cvs/cds
2017-11-18 07:03:00,113 INFO Backup rsync job ran successfully, transferred 1954 files.
2017-11-19 07:00:02,564 INFO Updating backup image of /cvs/cds
2017-11-19 07:00:02,592 ERROR External drive not mounted!!!
|
13963
|
Thu Jun 14 15:21:58 2018 |
gautam | Update | Computer Scripts / Programs | /cvs/cds Backup in danger |
I think this is because /cvs/cds is getting too big. lsblk reveals:
controls@chiara|~> lsblk
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
sda 8:0 0 465.8G 0 disk
├─sda1 8:1 0 446.9G 0 part /
├─sda2 8:2 0 1K 0 part
└─sda5 8:5 0 18.9G 0 part [SWAP]
sdb 8:16 0 2.7T 0 disk
└─sdb1 8:17 0 2T 0 part /home/cds
sr0 11:0 1 1024M 0 rom
sdc 8:32 0 1.8T 0 disk
└─sdc1 8:33 0 1.8T 0 part /media/40mBackup
sdd 8:48 0 1.8T 0 disk
└─sdd1 8:49 0 1.8T 0 part
I believe one of sdc or sdd is connected via SATA while the other is an external USB drive. Maybe we have to get bigger backup disks, but this may be a huge pain to setup as it will involve taking chiara down. Actually, now that I check the backup log, seems like backup is executing successfully - not sure if this is due to my unelogged mounting of sdc (using sudo mount /dev/sdc1 /media/40mBackup) last week, or if this is some LDAS backup. But in any case, seems undesirable that sdb1 is larger than sdc1 or sdd1.
2018-06-06 07:00:01,086 INFO Updating backup image of /cvs/cds
2018-06-06 07:00:01,086 ERROR External drive not mounted!!!
2018-06-07 07:00:01,147 INFO Updating backup image of /cvs/cds
2018-06-07 07:00:01,147 ERROR External drive not mounted!!!
2018-06-08 07:00:01,244 INFO Updating backup image of /cvs/cds
2018-06-08 08:23:32,939 INFO Backup rsync job ran successfully, transferred 316870 files.
2018-06-09 07:00:01,465 INFO Updating backup image of /cvs/cds
2018-06-09 07:12:11,865 INFO Backup rsync job ran successfully, transferred 1926 files.
2018-06-10 07:00:01,842 INFO Updating backup image of /cvs/cds
2018-06-10 07:12:28,931 INFO Backup rsync job ran successfully, transferred 1656 files.
2018-06-11 07:00:01,294 INFO Updating backup image of /cvs/cds
2018-06-11 07:06:14,748 INFO Backup rsync job ran successfully, transferred 1664 files.
2018-06-12 07:00:02,081 INFO Updating backup image of /cvs/cds
2018-06-12 07:07:36,775 INFO Backup rsync job ran successfully, transferred 1870 files.
2018-06-13 07:00:02,194 INFO Updating backup image of /cvs/cds
2018-06-13 07:08:37,356 INFO Backup rsync job ran successfully, transferred 1818 files.
2018-06-14 07:00:01,753 INFO Updating backup image of /cvs/cds
2018-06-14 07:01:43,270 INFO Backup rsync job ran successfully, transferred 1744 files.
Quote: |
Local backup on chiara seems not working since Nov 19, 2017.
/opt/rtcds/caltech/c1/scripts/backup/localbackup.log
2017-11-18 07:00:01,504 INFO Updating backup image of /cvs/cds
2017-11-18 07:03:00,113 INFO Backup rsync job ran successfully, transferred 1954 files.
2017-11-19 07:00:02,564 INFO Updating backup image of /cvs/cds
2017-11-19 07:00:02,592 ERROR External drive not mounted!!!
|
|
1683
|
Wed Jun 17 01:09:47 2009 |
rob | Update | Computers | /cvs/cds 91% full |
In /cvs/cds/caltech
1.6M 2008-8-15.pdf
2.9M 40mUpgradeOpticalLayoutPlan01.pdf
2.4M alh
19M apache
18G apps
11M archive
4.0K authorized_keys2
8.0K backup.notes
8.0K backup.notes~
1.9G build
62G burt
47M cds
13M cds40m
37M chans
70G conlog
52K crontab
12K cshrc.40m
12K cshrc.40m~
36M diag
1.4G dmt
8.2M framecpp-0.2.0
1.7M free_080730.pdf
57M gds
9.8G home
60K hooks
8.0K hosts.40m
4.0K id_rsa
10M iscmodeling
110M ldg-4.7
648M libs
4.0K log2.txt
224K logs
0 log.txt
238M medm
344M NB
148M NB_080304
211M NB_080307
401M NB40
1.2G noisebudget.071109
837M noisebudget.bak.20060623
3.5M oldtarget
123M root
5.7M savesets
208K schematics
655M scripts
13G scripts_archive
1.1M state
3.7G svn
4.0K svn-commit.tmp
7.3G target
295M target_archive
6.7M test
72K test.png
4.0K tmp
8.0K typescript
35G users
205M wind
|
583
|
Fri Jun 27 15:20:52 2008 |
rob | DAQ | LSC | .ini file change |
I removed C1:LSC-XARM_CTRL from the frames and added C1:LSC-CARM_ERR |