Entry  Wed Jan 6 08:09:04 2016, Steve, Update, PEM, 4.5 Mag Banning EQ 4.5Mag__Banning.png
IFO restored after 4.5 Mag Banning, Ca earthquake.
    Reply  Tue Mar 18 08:31:37 2014, Steve, Update, SUS, 4.4M local earthquake & its miracle miracel.pngETMX_LR.JPGETMX_LR-UL.JPGETMX_UL-LL-S-IRshield.jpg


    
        
            Quote:
        
        
            

           It was little bit surprising to me but Rana's professorial rock'n roll excitation released its sticking
Entry  Mon Mar 17 09:27:05 2014, Steve, Update, SUS, 4.4M local earthquake 4.4M-Encino.png3.9-4.4Meq.pngEQdamage4.4.png
 It looks like that ETMX have  2 sticky magnets.
 
    Reply  Mon Mar 17 20:44:42 2014, rana, Update, SUS, 4.4M local earthquake 
 
    Reply  Mon Mar 17 21:55:36 2014, Koji, Update, SUS, 4.4M local earthquake 
It was little bit surprising to me but Rana's professorial rock'n roll excitation released its sticking on
the unconfirmed thing by unconfirmed reason.
I aligned the Xarm manually and via ASS.
    Reply  Tue Mar 18 00:51:02 2014, Jenne, Update, SUS, 4.4M local earthquake 
 
 I am really, really happy to hear that it was just a sticking situation.  Really happy.  
    Reply  Wed Dec 30 11:09:52 2015, Steve, Update, SUS, 4.4M EQ 4.4MeqDevore.pngfree.png
Suspensions recovered after 4.4 Mag EQ

 
    Reply  Thu Jan 16 08:19:29 2014, Steve, Update, PEM, 4.4 and 3.8M local earth quakes local4.4eq.pnglocal3.8eq.png


    
        
            
            
        
        
            
            It looks
Entry  Wed Jan 15 13:05:30 2014, Jenne, Update, PEM, 4.4 EQ in Fontana, CA 
It looks like there was a 4.4 magnitude earthquake near Fontana, CA around 1:30am today.  This tripped all of the suspension watchdogs, which Q
has just now re-enabled. 
Entry  Mon Dec 28 14:12:23 2015, Steve, Update, SUS, 4.2M EQ 4.2Meq.pngrecovered4.2M.png
Suspensions are recovered after 4.2 Mag earth quake. No obvoius sign of damage.

 
Entry  Wed May 17 08:19:59 2017, Steve, Update, SUS, 4.1M earthquake  eq_4.1_SantaBarbara.png4.1m_Isla_Vista_CA.png
Sus dampings recovered. ETMY oplev needs to be recentered.

GV May 17 11am: I shut down the BS, SRM,
ITMX and ITMY watchdogs, as the coil-driver boards for these optics are presently
    Reply  Mon Mar 23 09:42:29 2015, Steve, Summary, IOO, 4" PSL beam path posts .75odSSpost.pdfMC_mml_trans_clamp.jpgPMCmmLn.jpg
To achive the same beam height each components needs their specific post height.




 Beam Height
Base
Plate
Mirror Mount
Lens Mount
 Waveplates-Rotary
0.75" OD. SS Post Height
                     


 
 
 
 
 
 
 


    Reply  Mon Apr 22 19:48:56 2013, Jenne, Update, 40m Upgrading, 4 pins enough? 
Are 4 of these spring loaded pins enough?  I'm not sure how one pin can hold 2 lids at each point.  It seems like we need 8 pins.
    Reply  Tue Apr 23 15:00:20 2013, Jenne, Update, 40m Upgrading, 4 pins enough? 


    
        
            Quote:
        
        
            

           Are 4 of these spring loaded pins enough?  I'm not sure how one pin can hold 2 lids at each point.  It seems like we need 8 pins.
    Reply  Mon Jan 27 09:08:00 2014, Steve, Update, VAC, 4 days at atmosphere day4atm.pngvent76bgTp3d4.png
 
 
    Reply  Fri Jul 6 09:27:40 2012, steve, Update, VAC, 4 days at atm vent_moves.png
 I'm looking for some movement indicators of the vent-pump down events.
 
Entry  Wed Feb 11 18:11:46 2015, Koji, Summary, LSC, 3f modulation cancellation 
33MHz sidebands can be elliminated by careful choice of the modulation depths and the relative phase between the modulation signals.
If this condition is realized, the REFL33 signals will have even more immunity to the arm cavity signals because the carrier signal will lose
its counterpart to produce the signal at 33MHz.
    Reply  Thu Feb 12 23:47:45 2015, Koji, Update, LSC, 3f modulation cancellation 
- I built another beat setup on the PSL table at the South East side of the table.
- The main beam is not touched, no RF signal is touched, but recognize that I was present at the PSL table.
- The beat note is found. The 3rd order sideband was not seen so far.
    Reply  Sat Feb 14 00:48:13 2015, Koji, Update, LSC, 3f modulation cancellation 
[SUCCESS] The 3f sideband cancellation seemed worked nicely.

- Beat effeciency improved: ~30% contrast (no need for amplification)

- PLL locked
    Reply  Sat Feb 14 19:54:04 2015, Koji, Summary, LSC, 3f modulation cancellation beat_setup1.JPGbeat_setup2.JPGelectrical_setup.pdf
Optical Setup

[Attachment 1]

Right before the PSL beam goes into the vacuum chamber, it goes through an AR-wedged plate.
    Reply  Sat Feb 14 20:37:51 2015, Koji, Summary, LSC, 3f modulation cancellation beat_pd_response.pdfbeat_nominal.pdf3f_reduction.pdfbeat_3f_reduced.pdf
Experimental results

- PD response [Attachment 1]

The AUX laser temperature was swept along with the note by Annalisa [http://nodus.ligo.caltech.edu:8080/40m/8369]
Entry  Wed Mar 4 12:38:07 2009, Alberto, Update, Computer Scripts / Programs, 3f locking simulations 23_3f_40mOld_DDplots.pdf59_3f40m_Upgrade_DDplots.pdf20_3f_AdvL_DDplots.pdf
I simulated the REFL signals demodulated at the differential frequencies of the sidebands (f2-f1), at their summed frequencies (f2+f1). I also simulated
their combination as in the Double Demodulation.
 
I repeated the simulation for:
- Old (current) 40m
-
40m Upgrade
- AdvLIGO
 
I'm attaching the results to this elog entry.
 
The plots
Entry  Sat Sep 10 14:55:28 2011, Keiko, Update, LSC, 3f demodulation board check 
 To check the demodulation boards for REFL33 and REFL165, a long cable from ETMY (SUS-ETMY-SDCOIL-EXT monitor)
is pulled to the rack on Y side.
(1) A filter just after the RF input and (2) transfer function from the RF input to the demodulated signal will be checked for the two 3f demod
    Reply  Sat Sep 10 16:10:42 2011, Keiko, Update, LSC, 3f demodulation board check REFL33-input-filter.png
There is a LP filter just after the RF input of an demodulation board (its schematic can be found as D990511-00-C on DCC). I have checked if the 3f freq,
33MHz, can pass  this filter. The filter TF from the RF input to RF monitor (the filter is between the input
and monitor) on REFL33 demo-board was measured as shown in Fig. 1. At 33MHz, the magnitude is still flat and OK, but the phase is quite steep.
    Reply  Sat Sep 10 18:57:52 2011, Keiko, Update, LSC, 3f demodulation board check 
The phase delay due to the RF input filter on the demodulation board will not bother the resulting PDH signals.
I quickly calculated the below question (see the blue sentence in the quote below). I applied an arbitrary phase delay (theta) due to the filter
I measured, on the detected RF signal by the photo detector. Then the filtered RF signal is multiplied by cos(omega_m) then filter the higher (2 omega_m)
    Reply  Sun Sep 11 22:36:32 2011, Keiko, Update, LSC, 3f demodulation board check REFL33.pngREFL165.png
Filters at the RF inputs of REFL33 and REFL165 demodulation boards were measured again. The filters will be totally
fine for 33MHz and 165MHz.
Last time I forgot to calibrate the cable lengths, therefore the phase delay of the measurement included the cable lengths. This time the measurements
    Reply  Mon Sep 12 13:24:07 2011, Keiko, Update, LSC, 3f demodulation board check 
I also quickly checked the orthogonality of the demodulation board for REFL33 and REFL165 using function generators
and oscilloscope. I checked the frequencies at 1,10,100,1K,10KHz of the demodulated signals. They are fine and ready for 3f signal extraction.
    Reply  Mon Sep 12 16:27:01 2011, Keiko, Update, LSC, 3f demodulation board check 
Wait. I am checking the whitening filters of the 33 and 165 demodulation boards.
Also, LSC-REFL33-I-IN1(IN2, OUT) and LSC-REFL165-Q-IN1(IN2,OUT) channels may not be working??
 
    Reply  Mon Sep 12 18:40:35 2011, Keiko, Update, LSC, 3f demodulation board check 
LSC-REFL33-I-IN1(IN2, OUT) and LSC-REFL165-Q-IN1(IN2,OUT)
channels are back!
We disconnected and connected again the AA filters then the channels are fixed. Apparently the AA filters just before the digital world were somhow
    Reply  Tue Sep 13 15:00:25 2011, Keiko, Update, LSC, 3f demodulation board check WF33.pdfWF165.pdf
Whitening filters for the REFL33 & 165 demodulated channels were measured and confirmed that they are working. They can be turned on and off by un-white
filter switches on the MEDM screen because they are properly linked. The measured filter responses are showen below. (Sorry, apparentyl the thumbnails
are not shown here. Please click the attachments.) 
    Reply  Tue Sep 13 23:08:51 2011, Keiko, Update, LSC, 3f demodulation board check REFL33-modified.pngREFL165-modified.png
Keiko, Jamie , Kiwamu
The I and Q orthogonalities of REFL33 and 165 demodulation board were measured by "orthogonality.py"
 Python package scipy were addied on Pianosa to run this code. Please note that
    Reply  Thu Sep 15 01:06:20 2011, Keiko, Update, LSC, 3f demodulation board check 
In addition to REFL 33 ans 165, I checked the orthogonality for the other existing three channels.
 
AS11
    Reply  Fri Sep 16 21:26:12 2011, Keiko, Update, LSC, 3f demodulation board check 
The demodulation phases and gains for the all existing channels, AS11, REFL11,REFL55, REFL165, and REFL33, were
adjusted by the command "ezcawrite" commands. 
Entry  Tue May 20 16:48:52 2014, ericq, Update, LSC, 3f Stability 3fs.pdfCARMsweepPrcFields.pdf
So, I really should have done this as soon as Manasa measured the arm lengths... I've
updated my MIST model with the real arm lengths, but still am using assumed identical losses of 75ppm on each mirror. (I've tried measuring the arm losses
for real, but got numbers in the hundreds of ppms, so I need to reexamine things...) 
    Reply  Tue May 20 22:42:28 2014, ericq, Update, LSC, 3f Stability PRCangles.pdf
 Here's the angles of MICH and PRCL from the my earlier plot by themselves; this shows that the individual demod angles in REFL165 aren't changing
much either. 
Entry  Wed Sep 14 01:19:20 2011, Anamaria, Configuration, LSC, 3f PD Install in Progress 
I have reconfigured the refl beam path on the AP table to include REFL33 and REFL165. Would be done if we hadn't prepared P BSs instead of S, which required
some serious digging to find two others. And if someone hadn't stolen our two 3m SMA cables that Keiko and I made on our previous visit and I had
left with the 3f PDs. I don't expect them to reappear but if they do, it would be grand.
    Reply  Tue Nov 11 21:41:09 2014, Koji, Update, LSC, 3f DRMI sensing mat DRMI_radar.pdf
Sensing matrix calculation using DTT + Matlab
Note: If the signal phase is, for example,  '47 deg', the phase rotation angle is -47deg in order to bring this signal to 'I' phase.
Note2: As I didn't have the DQ channels for the actuation, only the relative signs between the PDs are used to produce the radar chart.
    Reply  Wed Nov 12 03:22:23 2014, Jenne, Update, LSC, 3f DRMI sensing mat 8x
Koji pointed out something to me that I think he had told me ages ago, and Rana alluded to last night:  Since I'm not tuning my "demod phase"
for the sensing matrix lockins, unless I happened to get very lucky, I was throwing away most of the signal.  Lame.  
So, now the magnitude is sqrt(real^2 + imag^2), where real and imag here are the I and Q outputs of the lockin demodulator, after the 0.1Hz lowpass. 
Entry  Tue Nov 11 03:48:46 2014, Jenne, Update, LSC, 3f DRMI SensMatMeas_10Nov2014_DRMI.pngSensMatMeas_10Nov2014_PRMI.png
I was able to lock the DRMI on 3f signals this evening, although the loops are not stable, and I can hear oscillations
in the speakers.  I think the big key to making this work was the placement of the SHP-150 high pass filter at the REFL165 PD, and also
the installation of Koji's 110 MHz notch filter just before the amplifier, which is before the demod board for REFL165.  These were done to prevent
Entry  Wed Nov 5 01:58:54 2014, ericq, Update, LSC, 3F RFPD RF spectra Nov52014_3fPD_DRMIspectra.zipREFL165_DRMIspectrum.pngREFL33_DRMIspectrum.png
Given the checkout of the aLIGO BBPDs happening (aLOG link), wherein the
PDs were acting funny, and Koji has made some measurements determining that intermodulation/nonlinearity of circuitry can corrupt 3F signals, I've made
a similar measurement of the RF spectra of REFL165 when we're locked on DRMI using 1F signals. Maybe this could give us insight to our bad luck using REFL165...
    Reply  Wed Nov 5 11:09:44 2014, Koji, Update, LSC, 3F RFPD RF spectra 
If you look at the intermodulation at 14 (4+10) and 16 (6+10), 15 (5+10) would make any problem, thanks to the notch at 1f and 5f.
BUT, this absolute level of 165MHz is too tiny for the demodulator. From the level of the demodulated signal, I can say REFL165 has
too little SNR. We want to amplify it before the demodulator.
    Reply  Wed Nov 5 22:25:42 2014, ericq, Update, LSC, 3F RFPD RF spectra REFL165_demod_DRMIspectrum.png
 
Now that I have followed the chain, the PD signal is indeed being amplified at the LSC rack. It goes into a ZFL-1000LN+ amplifier (~23dB gain at
165MHz and 15V supply), followed by a SHP-100 high pass filter, and then enters the RF IN of the demod board. 
    Reply  Thu Nov 6 01:58:55 2014, Koji, Update, LSC, 3F RFPD RF spectra 
Where is the PD out spectrum measured with the coupler??? 
    Reply  Thu Nov 6 11:49:58 2014, ericq, Update, LSC, 3F RFPD RF spectra 


    
        
            Quote:
        
        
            

           Where is the PD out spectrum measured with the coupler???
    Reply  Thu Nov 6 14:41:49 2014, Koij, Update, LSC, 3F RFPD RF spectra 
That's not what I'm asking.
Also additional cables are left connected to the signal path. I removed it.
    Reply  Fri Nov 7 02:21:12 2014, ericq, Update, LSC, 3F RFPD RF spectra 
 
After some enlightening conversation with Koji, we figured that the RF amplifier in the REFL165 chain is probably being saturated (the amp's 1dB
compression is at +3dBm, has 23dB gain, and there are multiple lines above -20dBm coming out of the PD). I took a few more spectrum measurements to quantify
    Reply  Fri Nov 7 14:41:18 2014, ericq, Update, LSC, 3F RFPD RF spectra 165_ampSaturation.png165_HPatPD.png


    
        
            Quote:
        
        
            

            After some enlightening conversation with Koji, we figured that the RF amplifier in the REFL165 chain is probably being saturated.
    Reply  Fri Nov 7 16:15:53 2014, Jenne, Update, LSC, 3F RFPD RF spectra 
I have found an SHP-150, but no SHP-175's (also, several 200's, and a couple of 500's).
Why do you say the SHP-150 isn't enough?  The blue peak at 10*fmod in your plot looks like it's at -12 dBm.  -13 dB on top of that will
leave that peak at -25 dBm.  That should be enough to keep us from saturation, right?  It's not a lot of headroom, but we can give it a twirl
    Reply  Sat Nov 8 11:35:05 2014, rana, Update, LSC, 3F RFPD RF spectra 
 
 I think 'saturation' here is a misleading term to think about. In the RF amplifiers, there is always saturation. What we're
trying to minimize is the amount of distorted waveforms appearing at 3f and 15f from the other large peaks. Usually for saturation we are
    Reply  Mon Nov 10 18:11:57 2014, ericq, Update, LSC, 3F RFPD RF spectra 165signals.pdf
 Jenne and I measured the situation using a SHP-150 directly attached to the REFL165 RF output, and at first glance, the magnitude of the 165MHz
signal seems to not be distorted by the amplifier. 
 
ELOG V3.1.3-