40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 333 of 344  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
Entry  Mon Jun 6 17:22:09 2011, valera, Configuration, LSC, Clipping in the X arm 1064 um trans path XarmTransMon.pdf
I changed optics in the ETMX transmon path to remove clipping (which made a false QPD signal).
During the weekend I found that there was an offset in X arm c1ass pitch servo, which derives the signal by demodulating the arm cavity power,
coming from the beam clipping in the transmon path.
Entry  Mon Jun 6 23:56:16 2011, rana, valera, Configuration, SUS, ETMX/ETMY OSEM whitening 
 We measured the OSEM PD whitening transfer function of the ETMX OSEM UL whitening stage (D000210) by comparing the input signal to the whitening amplifier (single pin LEMO monitor) to the output signal - both
were piped into the DAQ. The transfer function was close to constant 0 dB/180 deg independent of the whitening switch selection (FM1 filter engaged/disengaged)
Entry  Mon Jun 13 19:26:42 2011, Jamie, Joe, Configuration, CDS, SUS binary IO chassis 2 and 3 moved from 1X5 to 1X4 
While preping 1X4 for installation of c1lsc, we removed some old VME crates that were no longer in use.  This freed up lots of space in 1X4. 
We then moved the SUS binary IO chassis 2 and 3, which plug into the 1X4 cross-connect, from 1X5 into the newly freed space in 1X4.  This makes the
cable run from these modules to the cross connect much cleaner.
    Reply  Tue Jun 14 09:24:36 2011, steve, Configuration, Photos, SUS binary IO chassis 2 and 3 moved from 1X5 to 1X4 P1070891.JPGP1070893.JPG


    
        
            Quote:
        
        
            

           While preping 1X4 for installation of c1lsc, we removed some old VME crates that were no longer in use.  This freed up lots of space
Entry  Fri Jun 17 00:17:26 2011, rana, Configuration, Electronics, 2 RFPDs sent to LLO P1070895.JPG
Koji and I found 2 RFPD boxes to send to LLO. We've put them onto Steve's desk to be overnighted to Valera.
One of them is our old 21.5 MHz gold box RFPD from the FSS (which we don't use). The other one is a 2mm gold box one which was previously tuned
for 66 MHz.
Entry  Fri Jun 24 22:35:23 2011, rana, Configuration, CDS, dataviewer broken on pianosa 
When I try to get minute trend, it says "word too long". 
Entry  Thu Jun 30 21:55:16 2011, rana, Configuration, DAQ, NDS2 conf change Untitled.png
As I recently had trouble getting all of the SUS SENSOR channels at once from NDS2, I asked J.Z. for help. He found that the number of buffers on mafalda
was set to only allow a small amount of data to be requested at one time.
He's going to have to figure out a more permanent fix, but for now he's increased the data buffer size to allow somewhat larger chunks to be gotten.
Entry  Mon Jul 11 10:10:31 2011, Ishwita, Configuration, , AA board  P7080305.JPGseismometers.png
The AA board shown in attachment 1 will be used in the seismometer hardware setup. A cartoon of this setup is shown in attachment 2.
BNC connectors are required for the seismometer breakout boxes. So the four-pin LEMO connectors present in the AA board were removed and panel
mount BNC connectors were soldered to it. Red and blue colored wires were used to connect the BNC connectors to the board. Red wire connects the center
Entry  Sat Jul 16 18:54:05 2011, Ishwita, Manuel, Configuration, Electronics, AA board DSC_3236.JPGpic1.pngDSC_3237.JPG
We fixed the anti-aliasing board in its aluminum black box,  the box couldn't be covered entirely because of the outgoing wires of the BNC connectors,
so we drilled additional holes on the top cover to slide it backwards by 1cm and then screw it.
We had to fix the AA board box in rack 1X7, but there wasn't enough space, so we tried to move the blue chassis (ligo electro-optical fanout chassis
    Reply  Wed Jul 27 15:49:13 2011, jamie, Configuration, CDS, dataviewer now working on pianosa 
Not exactly sure what the problem was, but I updated to the head of the SVN and rebuilt and it seems to be working fine now.
Entry  Fri Aug 12 16:42:51 2011, Yoichi, Configuration, LSC, LSC Feed Forward Compensator FFCinLSC.pngFFC.png
I've been working on adding feed forward (FF) paths to our LSC code.
So far, I've made a basic feed forward functionality connected
to the feedback path of the LSC model.
Entry  Fri Aug 12 16:50:37 2011, Yoichi, Configuration, CDS, FE Status screen rearranged 
I rearranged the FE_STATUS.adl so that I have a space to add c1ffc in the screen.
So, please be aware that the FE monitors are no longer in their original positions
in the screen.
Entry  Fri Aug 12 17:05:22 2011, Manuel, Ishwita, Configuration, PEM, STS2 Cable configuration 01050901.PDF
The WWF_M connector is the end of the STS2 seismometer orange cable and the S1 connector is the end of the gray 26-pin-cable
Entry  Mon Aug 22 20:37:43 2011, Anamaria, Configuration, RF System, Plan for install of 3f PDs 40m3fReflPdLayout.pdf
I made a quick sketch of how to include two more RF PDs on the REFL beam, given the space we have on the table. We want to install REFL33 and REFL165,
3f signals for the the two modulation frequencies we are using. The point is to make the distance from first beam splitter the same to all PDs so that
we can use only one lens before this BS to make the beam the right size. Currently there are 2 PDs on the refl beam, REFL11 and REFL55, predictably. So
Entry  Mon Aug 29 16:27:34 2011, Manuel, Configuration, SUS, SUS Summary Screen 
I edited the C1SUS_SUMMARY.adl file and set the channels in alarm mode to show the values in green, yellow and
red according to the values of the thresholds (LOLO,
Entry  Mon Sep 12 18:45:04 2011, Anamaria, Configuration, LSC, AP table current layout 40mAPtable.pdf
Before we install the REFL 3f PDs I made a drawing of the current table layout, since there has been no update lately. Once I've incorporated the two
extra PDs (now seen sitting bottom left), I will update the drawing and post in the wiki as well.
Entry  Mon Sep 12 23:45:14 2011, Suresh, Configuration, Computer Scripts / Programs, StripTool does not scale properly on Pianosa 
When I run StripTool on Pianosa, I get the following message
==== StripTool Xt Warning Handler ====
warning:         Axis: minVal is greater than or equal to maxVal
Entry  Wed Sep 14 01:19:20 2011, Anamaria, Configuration, LSC, 3f PD Install in Progress 
I have reconfigured the refl beam path on the AP table to include REFL33 and REFL165. Would be done if we hadn't prepared P BSs instead of S, which required
some serious digging to find two others. And if someone hadn't stolen our two 3m SMA cables that Keiko and I made on our previous visit and I had
left with the 3f PDs. I don't expect them to reappear but if they do, it would be grand.
Entry  Tue Sep 20 20:58:35 2011, Anamaria, Configuration, LSC, New AP Table Drawing APtableSep20th.pdf
As promised, I have made a final AP table drawing, including the MC camera relocation changes by Kiwamu. I have posted it in the wiki on the tables list,
and on the AP table page I've attached the inkscape .svg I used to make it, if someone needs to do small modifications.
Attached is a pdf version of it.
Entry  Fri Oct 7 22:41:05 2011, Koji, Configuration, General, Script backup fixed  
Script backup regularly runs on op340m by crontab,
 but the true backup were not taken since Oct 16, 2010
as the backup program was looking at the old script directory.
Entry  Tue Oct 18 21:19:18 2011, rana, Configuration, IOO, WFS disabled in SUS 
I found that the MC WFS had large offset control signals going to the MC SUS. Even though the input switch was off, the integrators were holding the
offset.
I have disabled the ASCPIT outputs in the MC SUS. Suresh is going to fix the MC autolocker script to gracefully handle the OFF and ON and
    Reply  Tue Oct 18 22:47:09 2011, Suresh, Configuration, IOO, MC autolocker script edited to shutdown and restart WFS loops  


    
        
            Quote:
        
        
            
            I found that the MC WFS had large offset control signals going to the MC SUS. Even though the input switch was off,
Entry  Mon Nov 14 21:22:48 2011, rana, Configuration, Computers, primetime RSYNC slowing down NODUS 
nodus:elog>w; who ; date
  9:20pm  up 44 day(s),  5:14,  5 users,  load average: 0.29, 1.04, 1.35
User     tty           login@  idle   JCPU   PCPU 
Entry  Wed Nov 23 14:47:14 2011, Jenne, Configuration, Environment, AC in the IFO room was off 
I turned it back on, maybe around 11am?  Definitely a little while before the 12:30 meeting.
EDIT by KI:
 Sorry, it's me. I was checking if AC was doing something bad on the ALS noise.
Entry  Wed Dec 21 14:23:08 2011, rana, Configuration, SUS, Hysteresis in suspensions? 
While discussing the suspension hysteresis measurements, Koji, Kiwamu, and I realized that the suspension wire standoff is aluminum, whereas the standoff
for the LIGO LOS are using
quartz.
Entry  Thu Jan 12 21:22:16 2012, Leo Singer, Configuration, WIKI-40M Update, Unable to create Wiki page 
 I can't create a new page on the 40m wiki.  The page that I was trying to create is
http://blue.ligo-wa.caltech.edu:8000/40m/Stewart
I get this message when I try to save the new page:
    Reply  Thu Jan 12 23:13:42 2012, Koji, Configuration, WIKI-40M Update, Unable to create Wiki page 


    
        
            Quote:
        
        
            
             I can't create a new page on the 40m wiki.  The page that I was trying to create is
Entry  Sat Jan 14 00:50:08 2012, rana, koji, Configuration, IOO, Towards coating thermal noise measurement with RefCav / MC beat 
Koji asked aloud tonight if we could measure
the coating thermal noise of the refcav optics by beating the refcav light with the MC_TRANS light. Then we looked at our calculations for the noises:
Displacement noise of T=200ppm silica/tantala coating on a 1" silica substrate with a 300 micron beam
    Reply  Tue Jan 17 03:10:27 2012, kiwamu, Configuration, IOO, rotated lambda/2 plate  
I have slightly rotated the lambda/2 plate, which is used for attenuating the REFL beam's power on the AS table
because the plate had been at an unusual angle for investigation of the glitches since last Thursday.
It means the laser power going to the coating thermal noise setup has also changed. Just keep
Entry  Fri Feb 3 19:54:21 2012, rana, Configuration, IOO, MC trans awry mctrans.png
As usual, I noticed several bad things within 30 seconds of sitting in front of the workstation. Today its that there are OFF or missing filters on the
MC TRANS.
is this the normal state? Screenshot attached.
Entry  Fri Feb 3 19:57:26 2012, rana, Configuration, SUS, PSL Shutter closed for SUS hysteresis test 
Fri Feb 03 19:57:20 2012
Fri Feb 03 20:25:19 2012 :   Aligned all SUS to center their OL beams
Fri Feb 03 20:29:21 2012:    Aligned all SUS to make OL_PIT = 0.5
Entry  Fri Feb 3 20:58:56 2012, Steve, Configuration, General, Illuminator Picture P1080526.JPG
 
Entry  Mon Mar 5 23:47:15 2012, keiko, Configuration, LSC, ND2 at REFL OSA 
ND filter ND3 (which is at the REFL port to
the REFL OSA) is removed. Don't forget to put it back when you restore PRM!!!
    Reply  Tue Mar 6 16:06:15 2012, Jenne, Configuration, SUS, PRM watchdog tripped 


    
        
            Quote:
        
        
            
            ND filter
Entry  Thu Mar 15 04:04:23 2012, Koji, Configuration, Locking, PRC Matching issues P3150910.jpgP3150902.jpgP3150906.jpgP3150907.jpgP3150900.jpg
Kiwamu and Koji
We found that the intra-cavity mode of the PRC is not round although it was obvious even with the DARK and REFL port images.
We need to review the mode matching situation.
Entry  Tue Mar 27 21:37:51 2012, keiko, Configuration, IOO, Beam Profile measurement: IPPOS beam 9x
 From the mode measurement I and Suresh have done yesterday, I calculated what beam size we expect at ETM ((1) upper Fig.1)  and at ETM after
one bounce ((2) lower Fig.1).
Entry  Thu Mar 29 20:13:21 2012, jamie, Configuration, PEM, PEM_SLOW (i.e. seismic RMS) channels added to fb master 
I've added the PEM_SLOW.ini file to the fb master file, which should give us the slow seismic RMS channels when the framebuilder is restarted.  Example
channels:

[C1:PEM-RMS_ACC6_1_3]
[C1:PEM-RMS_GUR2Y_0p3_1]
[C1:PEM-RMS_STS1X_3_10]
etc.

I also updated the path to the other _SLOW.ini files.
    Reply  Wed Apr 4 13:25:29 2012, jamie, Configuration, PEM, PEM_SLOW (i.e. seismic RMS) channels aquiring 2012-04-04-132346_1182x914_scrot.png


    
        
            Quote:
        
        
            

           I've added the PEM_SLOW.ini file to the fb master file, which should give us the slow seismic RMS channels when the framebuilder is restarted.
Entry  Thu Apr 5 18:24:55 2012, Den, Configuration, Adaptive Filtering, oaf starts to work oaf2.pdf
Today I tried to make the lms filter to work online. I played around with the signals (GUR1_X and MC_F) to pre-whiten them and in the end the following
configuration worked out:
1. mu = 0.03, tau = 1e-5, downsample=8, nCoeff = 4000, delay = 5 (sample-and-hold delay is not included in the new code, it should be added
Entry  Tue May 22 11:45:12 2012, Jamie, Configuration, CDS, Please remember to commit SVN changes 
Hey, folks.  Please remember to commit all changes to the SVN in a timely manor.  If you don't, multiple commits will get lumped together and
we won't have a good log of the changes we're making.  You might also end up just loosing all of your work.  SVN COMMIT when you're done! 
But please don't commit broken or untested code.
Entry  Fri May 25 16:58:54 2012, Jamie, Configuration, Computers, .bashrc for workstations 
I have setup a shared .bashrc for all the workstations that is symlinked to the normal location on all machines:

controls@rossa:~ 0$ ls -al /home/controls/.bashrc 
lrwxrwxrwx 1 controls controls 23 2012-05-25 15:37 /home/controls/.bashrc -> /users/controls/.bashrc
controls@rossa:~
0$ 

This should help simplify maintenance considerably.  Editing that file on one machine will edit it for all.  
Entry  Tue Jun 12 13:49:32 2012, Jamie, Configuration, Computer Scripts / Programs, tconvert 
A nicer, better maintained version of tconvert is now supplied by the lalapps package.  It's called lalapps_tconvert. 
I installed lalapps on all the workstations and aliased tconvert to point to lalapps_tconvert.
Entry  Mon Jul 9 16:28:13 2012, Masha, Configuration, General, Seismometer repositioning  
Today I REPOSITIONED THE SEISMOMETERS in order to triangulate
noise sources (as Rana suggested). 
    Reply  Tue Jul 10 10:50:02 2012, Jamie, Configuration, General, Seismometer repositioning  


    
        
            Quote:
        
        
            

           Today I REPOSITIONED THE SEISMOMETERS 
Entry  Tue Jul 31 15:33:17 2012, Masha, Configuration, PEM, Gurlap Pin Map GurlapPinMap3.png
I checked the connections specified in the old Gulap Pin Map and found that they do not correspond
to the current values. I mapped out the current connections (in this case, the letter refers to the labeled
pin on the mil/spec while the number refers to the pin on the 37 pin DSub, labeled consecutively):
Entry  Thu Aug 2 22:52:23 2012, Masha, Configuration, PEM, STS, GUR2, and Trillium in isolation box. 
Den and I moved the Streckeisen, Guralp 2, and Trillium seismometers to the isolation box in order to measure the noise of the Streckeisen while we have
the Trillium.
Entry  Wed Aug 8 19:54:06 2012, Manasa, Configuration, IOO, MC trans optics configured Pic1.png
Jan and I wanted to measure the ringdown at the IMC. Since the QPD at the MC trans is not fast enough for ringdown measurements, we decided to install
a pickoff to include a faster PD while not disturbing much of the current MC trans configuration. The initial configuration had very little space to accommodate
the pickoff. So the collimating lens along with the QPD were moved 2 inches closer to the incoming beam. A 50-50 BS was put in front of the QPD and the
    Reply  Wed Aug 8 22:12:30 2012, rana, Configuration, IOO, MC trans optics configured 
  The PDA255 is a
good ringdown detector - Steve can find one in the 40m if you ask him nicely.
    Reply  Wed Aug 8 22:17:43 2012, Manasa, Configuration, IOO, MC trans optics configured 


    
        
            Quote:
        
        
            

             The
    Reply  Fri Aug 10 09:54:51 2012, Manasa, Configuration, IOO, MC trans optics configured 


    
        
            Quote:
        
        
            

           
            
                
           
ELOG V3.1.3-