  582   Fri Jun 27 14:36:39 2008 JohnSummaryLocking Rob, Yoichi, John

Some progress last night:
 gettingcloser.png 
  581   Fri Jun 27 09:20:15 2008 steveFrogsPEMdust particle count is up & alarm handler is onThis 3 years plot show the trend of seasons.
When outside air quality goes bad ( 0.5 micron
> 1 million ) the lab follows.
 dust3y.jpg 
  580   Thu Jun 26 22:08:33 2008 JenneUpdateElectronics3.7MHz bandstop filter in MC Servo The 3.7MHz elliptical bandstop filter that
I made during my SURF summer is now installed
in the MC servo loop to reduce the noise
 MCLoopGainBoth.pngTP1ASpectrumBoth.pngQmonWithFilt.pngMCOut2WithFilt.png 
  579   Thu Jun 26 21:07:11 2008 ranaConfigurationASSdust & MC1I realized today, that yesterday while we
were trying to debug the adaptive noise canceler,
I turned
 Screenshot-2.png 
  578   Thu Jun 26 20:59:22 2008 ranaUpdateComputer Scripts / ProgramsAlarm Handler[COLOR=red][SIZE=5][B]Please do not turn off
the Alarm Handler on op540m.[/B][/SIZE][/COLOR]
  
  577   Thu Jun 26 18:29:44 2008 JenneUpdate MC Back onlineJenne, Rob, Yoichi

I was playing with the Mode Cleaner earlier
  
  576   Thu Jun 26 18:27:04 2008 ranaUpdateComputer Scripts / ProgramsNo Dataviewer No CryDataviewer was hanging. It would open the
Grace window but then not plot anything.
Since DTT was working
  
  575   Thu Jun 26 18:24:28 2008 YoichiUpdatePSLFSS input ofset slider problem - fixedI checked the FSS servo interface board and
found that a LT1125CSW used to differentialize
offset channel was broken (no virtual short).
  
  574   Thu Jun 26 14:06:00 2008 MashaUpdateGeneral500mW INNOLIGHT NPRO infoBelow is the placement of 500mW INNOLIGHT
NPRO mephisto laser. It is set up on the
Symmetric Port table. [IMG]elog:574/1[/IMG]
 500mW_NPRO.JPG 
  573   Thu Jun 26 12:30:40 2008 JohnSummaryLockingCARM on REFL_DC[COLOR=blue]Idea:[/COLOR]

Try REFL_DC as the error signal for CARM
  
  572   Thu Jun 26 10:56:15 2008 Max JonesUpdatePEMRemoved MagnetometerI removed the Bartington Magnetometer on the
x arm to one of the outside benches. I'll
be trying to determine if and how it works
  
  571   Thu Jun 26 01:10:18 2008 ranaUpdatePEMAlarm Handler indicates that dust level is high[I]In its first useful act[/I], the Alarm
Handler started beeping indicating that the
[COLOR=purple]dust particle
 Untitled.png 
  570   Thu Jun 26 01:08:22 2008 ranaConfigurationGeneralAlarm Handler RevivedI have revived the Alarm Handler by turning
it on on op540m and adjusting the levels
of
 b.gif 
  569   Wed Jun 25 18:03:21 2008 YoichiConfigurationPSLFSS Input Offset slider problemWhile working on the PMC scanning, I noticed
that the FSS input offset slider is doing
nothing.
  
  568   Wed Jun 25 13:56:56 2008 JohnSummaryLockingTuesday night lockingRob, John

Worked to try and reduce the CARM offset
  
  567   Wed Jun 25 13:38:22 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Placement of the 700mW NPRO on the AP tableThis morning I have put the 700mW NPRO on
the AP table for the abs length measurement.
 NPRO700mW_placement.jpg 
  566   Wed Jun 25 12:25:28 2008 EricSummaryCameras2D Gaussian Fitting CodeI initially wrote a script in MATLAB that
takes pictures of the laser beam's profile
and fits them to a two dimensional gaussian
  
  565   Wed Jun 25 11:36:14 2008 Max JonesUpdateComputer Scripts / ProgramsFirst Week UpdateFor the first week I have been modifying the
noise budget script in caltech/NB to run
with 40 m parameters and data. As per Rana's
 C1_NoiseBudgetPlot_Day.epsC1_NoiseBudgetPlot_Night.eps 
  564   Wed Jun 25 11:01:45 2008 MashaUpdateAuxiliary lockingfiber stabilizationFor the first week, I have been learning about
fiber noise cancellation, auxiliary locking
techniques, and other relevant helpful topics
  
  563   Wed Jun 25 09:46:45 2008 SharonUpdate Adaptive FiltersI have been learning about different methods
for applying adaptive filters to improve
the Mode Cleaner lock in specific, and other
  
  562   Wed Jun 25 01:30:19 2008 JohnSummaryIOOFrequency noise after the MCI made some (very) rough estimates of the
contribution made to the noise after the
mode cleaner by three sources.
 MC2noise080623.png 
  561   Wed Jun 25 00:35:40 2008 KojiSummaryGeneralOptical Layout on the AP tableI have visited the AP table in order to investigate
where we are going to put the optical setup
for the abs. length meas. 
 optical_layout_ap_table.pngoptical_layout_ap_table.pdf 
  560   Tue Jun 24 22:43:23 2008 ranaSummarySEIStack TF   Screenshot.png 
  559   Tue Jun 24 22:31:10 2008 MashaUpdateAuxiliary lockingmy first step in fiber stabilizationThere is a new 1W INNOLIGHT NPRO laser at
the Symmetric Port.
  
  558   Tue Jun 24 17:12:10 2008 josephb, EricConfigurationCamerasGC750 setup, 1X4 Hub connected, ETMX imagesThe GC750 camera has been setup to look at
ETMX.  In addition, the new 1X4 rack mounted
switch (131.215.113.200) has been connected
 GC750_ETMX_E30000_single.pdfGC750_ETMX_E30000_avg.pdfGC750_ETMX_E30000_std.pdf 
  557   Tue Jun 24 15:15:09 2008 JohnSummaryLSCLocking effortsRob, Rana, John

In the past week or so we've been working
 mcl080623.png 
  556   Tue Jun 24 10:24:43 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Cavity Swing Measurement (2)At the entry 555, Alberto reported the results
of the cavity length measurement using cavity
sweeping.
 armlength.pngarmlength2.png 
  555   Mon Jun 23 21:51:19 2008 AlbertoUpdateGeneralArm Cavity Length MeasurementWe measured the arm cavity lengths sweeping
the ETM mirror position and looking at the
reflected demodulated output. We excited
 40mLengthMeasure.pdf 
  554   Mon Jun 23 19:48:28 2008 rana,albertoSummaryIOOStochMon trends (80 days)Here's a StochMon plot showing the RFAM after
the MC. Remember that in these units, 2V
means no RFAM
 e.png 
  553   Mon Jun 23 19:33:01 2008 rana, jenneUpdateIOOMC_F Noise checkWe looked at the MC_F spectrum because Rob
and Yoichi said that it had gone 'all crazy'.
It
 mcf.png 
  552   Mon Jun 23 15:22:04 2008 ranaBureaucracySAFETYLaser Safety Walkthrough today   Walkthrough08.jpg 
  551   Sun Jun 22 21:38:49 2008 robHowToGeneralIFO CONFIGURE
Now that we're getting back into locking,
it's nice to have a stable alignment of the
  
  550   Fri Jun 20 17:42:48 2008 steveUpdatePSLSS trap scattering compared to black glass trapCircular SS304 trap was compared to wedged
black glass trap.
 cSSt_1.pngcSSt_2.pngscatset_61908.pngcSSt&wBGt.pngcSStbeam.png 
  549   Fri Jun 20 08:30:27 2008 stivUpdatePhotos40m summer line up 2008atm1: John, Alberto, Yoichi, Koji, Masha,
and Sharon 
 P1020559.pngP1020560.png 
  548   Fri Jun 20 02:20:33 2008 YoichiUpdate PMC transmittance degradationThe PMC transmitted light power has been degrading
constantly for last two weeks (see the attachment
1).
 pmc_trans_long_trend.pdfpmc_trans_improvement.pdf 
  547   Fri Jun 20 01:38:55 2008 ranaUpdatePEM20 day WeatherYoichi showed me that its possible to make
PNG images from PS using GS:
 test.png 
  546   Thu Jun 19 20:22:03 2008 ranaUpdateGeneralFE Computer StatusI called Rolf (@LLO) who called Alex (@MIT)
who suggested that we power cycle every crate
  
  545   Thu Jun 19 15:52:06 2008 AlbertoConfigurationComputersMeasure of the current absorbed by the new Megatron ComputerTogether with Rich Abbot, sam Abbot and I
measured the current absorbed by the new
Megatron computer that we installed yesterday
  
  544   Wed Jun 18 18:50:09 2008 ranaUpdateComputersIt can only be attributable to human error. (HAL - 2001)[B]There has been another one of "those" events
and all of the front end machines are down.[/B]
  
  542   Wed Jun 18 18:32:09 2008 Max JonesUpdateComputer Scripts / ProgramsNB UpdateI am reconfiguring the the noisebudget code
currently in use at the sights. To that end,
I have done the following things (in addition
  
  541   Wed Jun 18 18:26:19 2008 YoichiUpdatePSLFinding the optimal operation temperature for the NPRO by the slow act scanBeing suspicious of the temperature stabilization
of the NPRO crystal, I ran the slow scan
script written by Rana to find the suitable
 FSS-slow-scan.pdf 
  540   Wed Jun 18 18:20:10 2008 YoichiUpdatePSLInvestigation on the NPRO temperature stabilization glitchesAs Rob pointed out in http://dziban.ligo.caltech.edu:40/40m/537
the MOPA NPRO has been showing some glitchiness
in the LTEC loop.
 LTEC-loop-HeatGun-Response.pdfLTMP-glitches.pdf 
  539   Wed Jun 18 16:37:54 2008 steve,ranaUpdateSAFETYCO2 test in the east armThe CO2 laser and table are in the east arm
for characterization of the mechanics. We
will not be operating it until we have an
 co2.png 
  538   Wed Jun 18 16:07:57 2008 robSummaryComputersRFM network down
The RFM network tripped off around noon today.
 It's still down.  The problem appears to
  
  537   Wed Jun 18 00:19:29 2008 robUpdatePSLMOPA trend15 day trend of MOPA channels.  The NPRO temperature
fluctations are real, and causing the PMC
to consistently run up against its rails.
 MOPAtrend.png 
  536   Tue Jun 17 22:00:53 2008 JohnHowToPSLProblems turning MZ servo on/offWe were unable to toggle the MZ servo on/off
(Blank/Normal) from MEDM. Pushing on the
Xycom board and cables changed the fault
  
  535   Mon Jun 16 18:26:01 2008 Max JonesUpdateComputer Scripts / ProgramsNoise Budget ChangesIn the directory cvs/cds/caltech/NB the following
changes were made:
  
  534   Fri Jun 13 11:17:25 2008 YoichiUpdatePSLPMC transmittance at high powerWe received a new cable for the Scientech
calorimeter. So I measured the transmittance
of the PMC at higher power.
  
  533   Thu Jun 12 15:55:15 2008 robUpdateLockingreport[quote]Rob: Awesome figure. As you can imagine,
I have lots of questions, and hope that you
will consider this figure to be the beginning,
  
  532   Thu Jun 12 15:09:33 2008 alanUpdateLockingreportRob: Awesome figure. As you can imagine, I
have lots of questions, and hope that you
will consider this figure to be the beginning,
  