Entry  Wed Sep 21 17:01:59 2022, Paco, Update, BHD, BH55 RFPD installed - part I IMG_3760.jpegIMG_3764.jpeg
    Reply  Thu Sep 22 19:51:58 2022, Anchal, Update, BHD, BH55 LSC Model Updates - part II 
       Reply  Fri Sep 23 19:04:12 2022, Anchal, Update, BHD, BH55 LSC Model Updates - part III 
    Reply  Fri Sep 23 14:10:19 2022, Radhika, Update, BHD, BH55 RFPD installed - part I IMG_3766.jpegIMG_3770.jpegIMG_3773.jpeg
       Reply  Fri Sep 23 18:31:46 2022, rana, Update, BHD, BH55 RFPD installed - part I 
          Reply  Mon Sep 26 11:39:37 2022, Paco, Update, BHD, BH55 RFPD installed - part II PXL_20220926_175010061.MOTION.jpgBH55_Transimpedance_Measurement.pdf
Entry  Thu Aug 4 19:01:59 2022, Tega, Update, Computers, Front-end machine in supermicro boxes IMG_20220804_184444473.jpgIMG_20220804_191658206.jpgIMG_20220804_185336240.jpgIMG_20220804_185023002.jpg
    Reply  Mon Aug 8 17:16:51 2022, Tega, Update, Computers, Front-end machine setup IMG_20220808_170349717.jpg
       Reply  Wed Aug 10 20:51:14 2022, Tega, Update, Computers, CDS upgrade Front-end machine setup IMG_20220810_171002928.jpgIMG_20220810_171019633.jpg
          Reply  Tue Aug 16 18:22:59 2022, Tega, Update, Computers, c1teststand rack mounting for CDS upgrade IMG_20220816_180157132.jpgIMG_20220816_175125874.jpg
             Reply  Wed Aug 17 11:10:51 2022, rana, Update, Computers, c1teststand rack mounting for CDS upgrade 
             Reply  Mon Aug 22 19:02:15 2022, Tega, Update, Computers, c1teststand rack mounting for CDS upgrade II IMG_20220822_185437763.jpgIMG_20220822_131340214.jpgc1bhd.jpegc1lsc.jpeg
                Reply  Tue Aug 23 22:30:24 2022, Tega, Update, Computers, c1teststand OS upgrade - I 
                Reply  Fri Aug 26 14:05:09 2022, Tega, Update, Computers, rack reshuffle proposal for CDS upgrade 6x
                   Reply  Sun Aug 28 23:14:22 2022, Jamie, Update, Computers, rack reshuffle proposal for CDS upgrade 
                      Reply  Mon Aug 29 15:15:46 2022, Tega, Update, Computers, 3 FEs from LLO got delivered today IMG_20220829_145533452.jpgIMG_20220829_144801365.jpg
                         Reply  Tue Aug 30 15:21:27 2022, Tega, Update, Computers, 3 FEs from LHO got delivered today IMG_20220830_144925325.jpgIMG_20220830_142307495.jpgIMG_20220830_143059443.jpg
                   Reply  Mon Sep 19 20:21:06 2022, Tega, Update, Computers, 1X7 and 1X6 work IMG_20220919_204013819.jpgIMG_20220919_203541114.jpgIMG_20220919_203458952.jpg
                      Reply  Tue Sep 20 23:06:23 2022, Tega, Update, Computers, Setup the 6 new front-ends to boot off the FB1 clone IMG_20220921_084220465.jpgdolphin_err_init_state.pngdolphin_final_state.png
                         Reply  Wed Sep 21 17:16:14 2022, Tega, Update, Computers, Setup the 6 new front-ends to boot off the FB1 clone 
                            Reply  Thu Sep 22 20:57:16 2022, Tega, Update, Computers, build, install and start 40m models on teststand  dolphin_state_plus_c1shimmer.pngFE_status_overview.png
                               Reply  Fri Sep 23 19:07:03 2022, Tega, Update, Computers, Work to improve stability of 40m models running on teststand  dolphin_state_all_green.pngdolphin_state_IPC_glitch.png
Entry  Fri Sep 23 10:05:38 2022, JC, Update, VAC, N2 Interlocks triggered  Screenshot_2022-09-23_10-19-39.pngScreenshot_2022-09-23_10-22-45.png
Entry  Wed Sep 21 10:10:22 2022, Yehonathan, Update, CDS, C1SU2 crashed 
Entry  Tue Sep 20 18:18:07 2022, Anchal, Summary, SUS, ETMX, ETMY damping loop gain tuning 
Entry  Tue Sep 20 15:40:07 2022, yehonathan, Update, BHD, Trying doing AC lock Screenshot_2022-09-20_15-38-44.png
Entry  Mon Sep 19 17:02:57 2022, Paco, Summary, General, Power Outage 220916 -- restored all 
    Reply  Tue Sep 20 07:03:04 2022, Paco, Summary, General, Power Outage 220916 -- restored all 
Entry  Tue Sep 13 14:12:03 2022, Yehonathan, Update, BHD, Trying LO phase locking again Screenshot_2022-09-13_17-41-33.png
    Reply  Thu Sep 15 21:12:53 2022, Paco, Update, BHD, LO phase "dc" control lophase_oltf.pdflophase_noise_spectra.pdf
Entry  Thu Sep 15 16:19:33 2022, Yehonathan, Update, LSC, POX-POY noise budget XARM_Actuation_Plot.pdfYARM_Actuation_Plot.pdfSensitivity_Plot_1347315385.pdf
Entry  Thu Sep 15 11:13:32 2022, Anchal, Summary, ASS, YARM and XARM ASS restored 
Entry  Wed Sep 14 15:40:51 2022, JC, Update, Treasure, Plastic Containers B0DD2BEC-E57E-4AA2-8672-2ABB41F44F84.jpeg
Entry  Thu Sep 8 16:03:25 2022, Yehonathan, Update, LSC, Realignment, arm locking, gains adjustments 
Entry  Thu Sep 8 12:01:02 2022, JC, Configuration, Lab Organization, Lab Organization F41AD1DA-29E9-4449-99CB-5F43AE527CA6_1_105_c.jpegFF5F2CE8-85E8-4B6F-8F8A-9045D978F670.jpeg
Entry  Thu Sep 8 11:54:37 2022, JC, Configuration, Lab Organization, Lab Organization 1A7026BC-82A9-49E9-BA22-1A700DFEC5D2.jpeg2A904809-82F0-40C0-B907-B48C3A0E789E.jpegCB4B8591-B769-454D-9A16-EE9176004099.jpeg
Entry  Fri Apr 22 07:01:58 2022, Jc, Update, Coil Drivers, Adding Resistors and Reinstalling 8x
    Reply  Fri Apr 22 12:09:51 2022, Anchal, Update, Coil Drivers, Please update DCC pages 
    Reply  Wed Sep 7 14:32:15 2022, Anchal, Update, SUS, Updated SD coil gain to keep all coil actuation signals digitally same magnitude 
Entry  Thu Aug 25 16:05:51 2022, Yehonathan, Update, SUS, Trying to fix some SUS PR2_Step_Response_Test_2022-08-25_16-23.pdfPR3_Step_Response_Test_2022-08-25_18-37.pdf
    Reply  Tue Sep 6 17:39:40 2022, Paco, Update, SUS, LO1 LO2 AS1 AS4 damping loop step responses LO1_Step_Response_Test_2022-09-06_17-19.pdfLO2_Step_Response_Test_2022-09-06_17-30.pdfAS1_Step_Response_Test_2022-09-06_17-53.pdfAS4_Step_Response_Test_2022-09-06_18-16.pdf
Entry  Tue Jul 6 17:40:32 2021, Koji, Summary, General, Lab cleaning 7x
    Reply  Tue Sep 6 09:57:26 2022, JC, Summary, General, Lab cleaning 982146B2-02E5-4C19-B137-E7CC598C262F.jpeg0FBB61AC-E882-458D-A891-7B11F35588FF.jpeg
Entry  Fri Sep 2 15:40:25 2022, Anchal, Summary, ALS, DFD cable measurements ICableOpenEnd_2022-09-02_3_08_34_PM.pngICableShortedEnd_2022-09-02_3_04_43_PM.pngQCableOpenEnd_2022-09-02_3_09_49_PM.pngQCableShortedEnd_2022-09-02_3_00_55_PM.pngDFD_Delay_Measurement.pdf
Entry  Wed Aug 31 00:46:56 2022, Koji, Update, General, Vertex Lab area to be cleaned 9x
    Reply  Wed Aug 31 01:22:01 2022, Koji, Update, General, Along the X arm part 1 9x
       Reply  Wed Aug 31 01:24:48 2022, Koji, Update, General, Along the X arm part 2 9x
          Reply  Wed Aug 31 01:25:37 2022, Koji, Update, General, Along the X arm part 3 9x
             Reply  Wed Aug 31 01:30:53 2022, Koji, Update, General, Along the X arm part 4 PXL_20220831_020757504.jpgPXL_20220831_020825338.jpgPXL_20220831_020856676.jpgPXL_20220831_020934968.jpgPXL_20220831_021030215.jpg
                Reply  Wed Aug 31 01:53:39 2022, Koji, Update, General, Along the Y arm part 1 9x
                   Reply  Wed Aug 31 01:54:45 2022, Koji, Update, General, Along the Y arm part 2 8x
                      Reply  Fri Sep 2 15:35:19 2022, Anchal, Update, General, Along the Y arm part 2 
       Reply  Fri Sep 2 15:30:10 2022, Anchal, Update, General, Along the X arm part 1 
    Reply  Wed Aug 31 16:11:37 2022, Koji, Update, General, Vertex Lab area to be cleaned PXL_20220831_224457839.jpgPXL_20220831_224816960.jpgPXL_20220831_225408183.jpgPXL_20220901_021729652.jpg
Entry  Wed Aug 31 00:32:00 2022, Koji, Update, General, SOS and other stuff in the clean room 6x
    Reply  Fri Sep 2 15:26:42 2022, Yehonathan, Update, General, SOS and other stuff in the clean room osem_sus.jpegmagnet_gluing.jpeg2-3inch_adapter_parts.jpegTTs.jpegBHD_optics.jpeg
Entry  Mon Sep 20 15:42:44 2021, Ian MacMillan, Summary, Computers, Quantization Code Summary 472px-Typical_State_Space_model.svg.pngBiquad_filter_DF-IIx.svg.pngSS-IIR-TF.pdf
    Reply  Wed Sep 22 14:22:35 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary IIR64-bitnoisespectrum.pdf
       Reply  Mon Sep 27 12:12:15 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary 
          Reply  Mon Sep 27 16:03:15 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary DeltaNoiseSpectrum.pdf
             Reply  Mon Sep 27 17:04:43 2021, rana, Summary, Computers, Quantization Noise Calculation Summary 
                Reply  Thu Sep 30 11:46:33 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary SS-IIR-Bode.pdfPSD_32bit.pdfPSD_64bit.pdf
                   Reply  Wed Nov 24 11:02:23 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary PSD_IIR_all.pdf
                      Reply  Wed Nov 24 13:44:19 2021, rana, Summary, Computers, Quantization Noise Calculation Summary 
                         Reply  Tue Dec 7 10:55:25 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary DF2_TS.pdfBIQ_TS.pdfScreen_Shot_2021-12-07_at_11.47.57_AM.pngPSD_COMP_BIQ_DF2.pdfPSD_COMP_SS_DF2.pdf
                            Reply  Fri Dec 10 13:02:47 2021, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary G0900928-v1_(dragged).pdfPSD_COMP_BIQ_DF2.pdfInput_PSD.pdfInput_Filter.pdfQuantizationN.zip
                               Reply  Mon May 9 15:32:14 2022, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary SUS-ETMX_SUSYAW3_0.0.pdfLowNoiseBiquad2.pdfquant_noise_floor.pdf
                                  Reply  Fri Sep 2 13:30:25 2022, Ian MacMillan, Summary, Computers, Quantization Noise Calculation Summary averagefiltering.pdfAveragingFilter.py.zip
Entry  Thu Sep 1 09:00:02 2022, JC, Configuration, Daily Progress, Locked both arms and aligned Op Levs Daily.pdfDaily.pdf
Entry  Wed Aug 31 12:57:07 2022, rana, Summary, ALS, control of ALS beat freq from command line -easy Untitled.png
Entry  Wed Aug 31 11:39:48 2022, Yehonathan, Update, LSC, Updated XARM noise budget Screenshot_2022-08-31_11-38-46.png
Entry  Mon Aug 29 18:25:12 2022, Cici, Update, General, Taking finer measurements of the actuator transfer function PZT_TF_fine.pngPZT_TF_fine_mag_stdev.pngATF_fine.zip
Entry  Mon Aug 29 13:33:09 2022, JC, Update, General, Lab Cleanup EDE63209-D556-41F1-9BF2-89CD78E3D7B7.jpeg
Entry  Fri Aug 26 12:46:07 2022, Cici, Update, General, Progress on fitting PZT resonances PZT_fit.zipAUX_PZT_Actuator_narrow_fit_1.pdf
Entry  Thu Aug 25 16:39:31 2022, Cici, Update, General, I have learned the absolute basics of github 
Entry  Thu Aug 25 15:24:06 2022, Paco, HowTo, Electronics, RFSoC 2x2 board -- fandango adc0_1137MHz.pngadc1_1137MHz.pngrfdc_PLLsettings.pngclockingwiz_settings.pngblockIPdiag.png
Entry  Wed Aug 24 16:37:52 2022, Cici, Update, General, More DFD/AUX PZT resonance measurements  AUX_PZT_Actuator_narrow_fit.pdf
Entry  Wed Aug 24 12:02:24 2022, Paco, Update, SUS, ITMX SUS is sus UL glitches? ITMX_UL_badness_08242022.png
Entry  Wed Aug 24 10:49:43 2022, Cici, Update, General, Measuring DFD output/X-arm laser PZT TF with Moku AUX_PZT_Actuator_nofit.pdf
Entry  Tue Aug 23 14:59:15 2022, JC, Update, Tools, New Toolbox at Y-End 9AFD3E49-0C5B-4626-889A-0A5C62590AD7.jpeg99EC2EB1-EEA0-4AD8-B6D7-A494431E91E5.jpeg
Entry  Wed Aug 17 07:35:48 2022, yuta, Bureaucracy, General, My wish list for IFO commissioning 
    Reply  Fri Aug 19 14:46:32 2022, Anchal, Update, SUS, Open loop transfer function measurements for local damping loops of BHD optics 
       Reply  Sat Aug 20 20:26:10 2022, Anchal, Update, SUS, Open loop transfer function measurements for local damping loops of Core optics ALL_CORE_SUS_OLTF_2022-08-20-merged.pdf
          Reply  Mon Aug 22 14:36:49 2022, rana, Update, SUS, Open loop transfer function measurements for local damping loops of Core optics 
Entry  Fri Aug 19 15:36:10 2022, Koji, Update, General, SR785 C21593 CHA+ BNC broken PXL_20220819_195619620.jpgPXL_20220819_195643478.jpg
Entry  Wed Aug 17 01:18:54 2022, Koji, Update, General, Notice: SURF SUS test setup blocking the lab way PXL_20220817_060428109.jpg
    Reply  Fri Aug 19 15:20:14 2022, Koji, Update, General, Notice: SURF SUS test setup blocking the lab way PXL_20220819_201318044.jpg
Entry  Fri Jul 1 08:50:48 2022, yuta, Summary, LSC, FPMI with REFL/AS55 trial 
    Reply  Thu Jul 14 00:10:08 2022, yuta, Summary, LSC, FPMI with REFL/AS55 trial continued AS55_I.pngAS55_Q.pngREFL55_I.pngREFL55_Q.png
       Reply  Fri Jul 15 19:13:22 2022, Paco, Summary, LSC, FPMI with REFL/AS55 demod phase adjust 
          Reply  Fri Jul 15 22:36:04 2022, rana, Summary, LSC, FPMI with REFL/AS55 demod phase adjust 
          Reply  Mon Jul 18 16:39:07 2022, Paco, Summary, LSC, FPMI locking procedure using REFL55 and AS55 DARM_07_18_2022_FMPI.pdfCARM_07_18_2022_FPMI.pdfMICH_07_18_2022_FPMI.pdffpmi_darm_nb_2022_07.pdf
             Reply  Mon Jul 18 21:41:42 2022, Anchal, Summary, LSC, FPMI locking procedure using REFL55 and AS55 
             Reply  Tue Aug 9 19:54:31 2022, yuta, Summary, LSC, FPMI locking tonight 
                Reply  Thu Aug 18 14:49:35 2022, Yehonathan, Summary, LSC, FPMI Sensitivity Sensitivity_Plot_1344133503.pdf
                   Reply  Thu Aug 18 18:10:49 2022, Koji, Summary, LSC, FPMI Sensitivity 
Entry  Thu Aug 18 16:35:29 2022, Cici, Update, General, UGF linked to optical gain! rpi_OLG_2022_08_17_18_03_52.pdfrpi_OLG_2022_08_17_18_00_50.pdf
Entry  Wed Aug 17 10:27:49 2022, Cici, Update, General, Locking X-arm AUX laser rpi_OLG_2022_08_16_17_00_41.pdfrpi_OLG_2022_08_16_17_01_21.pdf
Entry  Mon Aug 15 10:27:56 2022, Koji, Update, General, Recap of the additional measures for the outage prep PXL_20220812_234438097.jpgPXL_20220812_234655309.jpgPXL_20220812_234748559.jpgrn_image_picker_lib_temp_b5f3e38d-796c-4816-bc0e-b11ba3316cbe.jpgPXL_20220812_235429314.jpg
    Reply  Mon Aug 15 15:43:49 2022, Anchal, Update, General, Complete power shutdown and startup documentation 
       Reply  Mon Aug 15 18:06:07 2022, Anchal, Update, General, c1vac issues, 1 pressure gauge died 
          Reply  Mon Aug 15 20:09:18 2022, Koji, Update, General, c1vac issues, 1 pressure gauge died 
             Reply  Wed Aug 17 10:23:05 2022, Tega, Update, General, c1vac issues, pressure gauge replacement 
Entry  Fri Aug 12 13:40:36 2022, JC, Update, General, Preparing for Shutdown on Saturday, Aug 13 
Entry  Fri Aug 12 02:02:31 2022, Koji, Update, General, Power Outage Prep: nodus /home/export backup 
Entry  Thu Aug 11 17:15:33 2022, Cici, Update, General, Measuring AUX Laser UGF with Red Pitaya rpi_OLG_2022_08_11_16_51_53.pdfrpi_OLG_2022_08_11_16_51_53.txt
Entry  Wed May 20 20:10:34 2020, rana, John Z, Update, Computer Scripts / Programs, NDS2 server / conf updated - seems OK now 
    Reply  Thu May 21 15:31:26 2020, gautam, Update, Computer Scripts / Programs, NDS2 service restarted 
       Reply  Fri May 22 10:37:41 2020, rana, Update, Computer Scripts / Programs, NDS2 service restarted 
          Reply  Mon May 25 10:54:41 2020, rana, Update, Computer Scripts / Programs, NDS2 service restarted 
    Reply  Thu Aug 11 16:48:59 2022, rana, Update, Computer Scripts / Programs, NDS2 updates 
Entry  Wed Aug 10 20:30:54 2022, Tega, Summary, SUS, Characterisation of suspension damping 12x
Entry  Wed Aug 10 19:36:45 2022, Koji, Bureaucracy, General, Lab cleaning and discovery steel_plate.jpglogbook1.jpglogbook2.jpgpaper_plots.jpg
Entry  Wed Aug 10 15:33:59 2022, Cici, Update, General, Working Red Pitaya VNA rpi_vna_test.pdf
    Reply  Wed Aug 10 19:24:19 2022, rana, Update, General, Working Red Pitaya VNA 
Entry  Tue Jul 19 18:41:42 2022, yuta, Update, BHD, Contrast measurements for Michelson and ITM-LO ContrastMeasurements.pdf
    Reply  Wed Jul 20 18:07:52 2022, Paco, Update, BHD, BHD MICH test BHD_MICH_OSC.pdf
       Reply  Tue Jul 26 20:54:08 2022, Paco, Update, BHD, BHD MICH test - LO phase control 20220726_BICHD.pdf
          Reply  Wed Jul 27 18:30:50 2022, yuta, Update, BHD, LO beam power at BHD DCPDs is significantly lower than expected LOBeamAtBHD.JPGITMXSingleBounceAtBHD.jpg
             Reply  Thu Jul 28 14:34:40 2022, Yehonathan, Update, BHD, LO beam power at BHD DCPDs is significantly lower than expected 
                Reply  Thu Jul 28 16:51:55 2022, Tega, Update, BHD, Shaking test for LO beam AS beam to BHD DCPDs Screenshot_2022-07-28_16-58-34_LOandASShaking.pngScreenshot_2022-07-28_18-08-55_DCPDPOPSuspensionCoherence.png
                   Reply  Thu Jul 28 20:16:26 2022, Anchal, Update, BHD, Shaking test for LO beam AS beam to BHD DCPDs 
                   Reply  Fri Jul 29 18:24:53 2022, Tega, Update, BHD, LO beam power improved by factor of 6 after LO and AS beam alignment LO_and_oldAS_settings.pngBHD_fringe_settings.pngScreenshot_2022-07-29_19-37-39.pngFromTheLeft-AS-POP-LO.JPG
                      Reply  Wed Aug 3 16:00:51 2022, yuta, Update, BHD, BHD fringe aligned with reduced LO and AS beam clipping Screenshot_2022-08-03_15-46-36_BHDfringeAlmostUnclipped.png
                         Reply  Tue Aug 9 15:33:12 2022, yuta, Update, BHD, BHD fringe contrast improved from 43% to 74% HPC-DCPD_B_OUT_1344118517_ITMY-LO.pngHPC-DCPD_A_OUT_1344118517_ITMY-LO.pngHPC-DCPD_B_OUT_1344118318_ITMX-LO.pngHPC-DCPD_A_OUT_1344118318_ITMX-LO.png
                            Reply  Tue Aug 9 15:50:22 2022, Koji, Update, BHD, BHD fringe contrast improved from 43% to 74% 
Entry  Fri Jul 29 20:21:11 2022, Koji, Update, PSL, FSSSlow/MCAutolocker issue (docker) 
    Reply  Sat Jul 30 10:38:12 2022, Anchal, Update, PSL, FSSSlow/MCAutolocker issue (docker) 
       Reply  Sat Jul 30 12:48:18 2022, Koji, Update, PSL, FSSSlow/MCAutolocker issue (docker) 
          Reply  Thu Aug 4 11:28:22 2022, Anchal, Update, PSL, FSSSlow/MCAutolocker issue (docker) 
             Reply  Mon Aug 8 14:47:10 2022, rana, Update, PSL, FSSSlow/MCAutolocker issue (docker) 
Entry  Wed Jul 20 11:58:45 2022, Paco, Summary, General, Jenne laser kaput? 
    Reply  Wed Jul 20 14:12:07 2022, Paco, Summary, General, Jenne laser kaput! 
       Reply  Wed Jul 20 15:58:52 2022, Koji, Summary, General, Jenne laser kaput! 
          Reply  Mon Jul 25 09:05:50 2022, Paco, Summary, General, Testing 950nm laser found in trash pile PXL_20220722_234600124.jpgPXL_20220722_234551918.jpg
             Reply  Fri Aug 5 17:03:31 2022, Yehonathan, Summary, General, Testing 950nm laser found in trash pile 20220805_164434.jpgLaserActuation_TF_Measurement.drawio.pdf
Entry  Fri Jul 29 22:37:54 2022, Koji, Update, IOO, WFS investigation PXL_20220730_040900843.jpgPXL_20220730_041216848.jpg
    Reply  Tue Aug 2 01:10:26 2022, Koji, Update, IOO, WFS investigation 220801_IMC_WFS_DEMOD.pdf220801_IMC_WFS_DEMOD2.pdfWFS1.pngWFS2.png
       Reply  Thu Aug 4 21:58:18 2022, Koji, Update, IOO, WFS investigation Screenshot_2022-08-04_22-10-57.pngScreenshot_2022-08-04_22-11-16.pngScreenshot_2022-08-04_22-11-53.pngScreenshot_2022-08-04_22-12-39.png
          Reply  Thu Aug 4 22:14:20 2022, Koji, Update, IOO, WFS investigation IMC_SUS_channels_TF.pdfIMC_WFS_channels_TF.pdfIMC_WFS_segment_TF.pdfIMC_WFS_220804.xlsx
             Reply  Thu Aug 4 22:14:38 2022, Koji, Update, IOO, WFS investigation Screenshot_2022-08-04_22-17-19.pngScreenshot_2022-08-04_22-18-45.png
                Reply  Thu Aug 4 22:32:31 2022, Koji, Update, IOO, Upon leaving the lab (WFS investigation) 
                   Reply  Fri Aug 5 12:42:12 2022, Koji, Update, IOO, IMC WFS: Overnight observation  Screen_Shot_2022-08-05_at_12.04.01.png
Entry  Wed Aug 3 15:01:13 2022, Koji, Update, General, Borrowed Dsub cables  PXL_20220803_215819580.jpg
Entry  Wed May 25 16:56:44 2022, Paco, Configuration, BHD, IFO recovery - IMC alignment 
    Reply  Wed May 25 17:34:47 2022, yuta, Configuration, BHD, IFO recovery - IFO alignment Screenshot_2022-05-25_17-47-57.png
       Reply  Thu May 26 19:55:43 2022, yuta, Configuration, BHD, Oplevs centered, BHD DCPDs are now online elog_1Y2.JPGelog_BHD.JPGelog_box.JPGScreenshot_2022-05-26_17-37-27_IFOaligned_OplevCentered.pngScreenshot_2022-05-26_20-35-02.png
          Reply  Fri May 27 17:45:53 2022, yuta, Configuration, BHD, BHD camera installed, GRY aligned 
             Reply  Thu Jun 2 20:05:37 2022, yuta, Configuration, PSL, IMC input power recovered to 1W, some alignment works Before.JPGAfter.JPG
                Reply  Fri Jun 3 12:13:58 2022, Paco, Configuration, CDS, Fix RFM channels  SoGreen.png
                   Reply  Fri Jun 3 15:22:51 2022, yuta, Update, LSC, Both arms locked with POY/POX, IR beam centered on TMs with ASS IRBeamsOnTMs.JPGScreenshot_2022-06-03_15-03-51.png
                      Reply  Fri Jun 3 17:42:50 2022, yuta, Update, LSC, MICH locks with AS55_Q Screenshot_2022-06-03_17-41-55.png
                         Reply  Sun Jun 5 19:46:40 2022, Paco, Update, LSC, Fixed IMC Trans sum issue 
                         Reply  Mon Jun 6 13:35:11 2022, Paco, Update, LSC, First calibrated spectra of MICH at AS55 Q Screenshot_2022-06-06_17-30-16_MICHOLTF.pngCalibrated_MICH_ERR.pdf
                            Reply  Fri Jun 17 16:22:21 2022, yuta, Update, LSC, Actuator calibration of BS. ITMX, ITMY, updated MICH displacement spectra from c1cal 6x
                               Reply  Thu Jul 7 18:18:19 2022, yuta, Update, LSC, Actuator calibration of ETMX and ETMX Screenshot_2022-07-05_14-52-01_OLTF.pngScreenshot_2022-07-05_14-54-03_TF.pngScreenshot_2022-07-05_14-56-41_Ratio.png
                                  Reply  Thu Jul 7 18:22:12 2022, yuta, Update, LSC, Actuator calibration of MC2 using Yarm TF.pngMC2.png
                                     Reply  Fri Jul 8 16:18:35 2022, rana, Update, LSC, Actuator calibration of MC2 using Yarm 
                                     Reply  Mon Jul 18 17:07:12 2022, yuta, Update, LSC, x4.12 added to ETMX coil outputs to balance with ETMY 
          Reply  Thu Jun 16 18:23:15 2022, Paco, Configuration, BHD, Recovering LO beam in BHD DCPDs Screenshot_2022-06-16_18-29-14_BHDLObeamISBACK.png
          Reply  Tue Jun 21 14:17:50 2022, yuta, Configuration, BHD, BHD DCPDs re-routed to c1sus2 C1X07ADC1.JPGBHDDCPDs.JPG
             Reply  Tue Jul 19 16:00:34 2022, yuta, Configuration, BHD, Fast channels for BHD DCPDs now available in c1lsc but not in c1hpc Screenshot_2022-07-19_14-26-39_c1hpc.pngScreenshot_2022-07-19_14-24-49_c1lsc.pngScreenshot_2022-07-19_15-51-25_GreenGreen.png
                Reply  Thu Jul 21 21:50:47 2022, Tega, Configuration, BHD, c1sus2 IPC update 
                   Reply  Fri Jul 22 15:05:26 2022, Tega, Configuration, BHD, c1sus2 shared memory and ADC fix Screenshot_2022-07-22_15-04-33_DCPD.pngScreenshot_2022-07-22_15-12-19_models.pngScreenshot_2022-07-22_15-15-11_ERR.pngScreenshot_2022-07-22_15-32-19_GDS.png
                      Reply  Fri Jul 22 17:46:10 2022, yuta, Configuration, BHD, c1sus2 watchdog update and DCPD ERR channels Screenshot_2022-07-22_17-48-25.png
                         Reply  Mon Jul 25 17:58:10 2022, Tega, Configuration, BHD, c1sus2 IPC dolphin issue update Screen_Shot_2022-07-25_at_5.43.28_PM.pngScreen_Shot_2022-07-25_at_5.21.10_PM.pngScreen_Shot_2022-07-25_at_5.30.58_PM.pngScreen_Shot_2022-07-25_at_5.35.19_PM.png
                            Reply  Mon Aug 1 18:42:39 2022, Tega, Configuration, BHD, c1sus2 IPC dolphin issue update c1sus2_dolphin.pngfb1_dxamin_status.pngdolphin_num_mem_init2.png
                               Reply  Tue Aug 2 17:25:18 2022, Tega, Configuration, BHD, c1sus2 dolphin IPC issue solved c1lsc_IPC_status.pngFE_lsmod_dependencies_c1sus2_b4_after_iop_unpdate.png
                      Reply  Mon Jul 25 18:09:41 2022, Tega, Configuration, BHD, BHD Homodyne Phase control MEDM screen Screen_Shot_2022-07-25_at_6.12.08_PM.pngScreen_Shot_2022-07-25_at_6.18.09_PM.png
Entry  Mon Aug 1 17:19:39 2022, Cici, Summary, General, RPitaya Data on Jupyter Notebook 
Entry  Wed Jul 13 17:30:19 2022, Koji, Update, CDS, Too huge script_archive 
    Reply  Thu Jul 28 15:11:59 2022, Koji, Update, CDS, Too huge script_archive 
Entry  Thu Jul 28 13:09:28 2022, yehonathan, Update, BHD, Mode matching considerations 
Entry  Wed Jul 27 14:39:04 2022, Deeksha, Update, Electronics, New and improved PZT TF data from the DFD tf_data.pnglatest_data.zipdfd_-_new.drawio.png
Entry  Tue Jul 26 19:50:25 2022, Deeksha, Update, Computer Scripts / Programs, Vector fitting data.pngfit_attempt.png
    Reply  Tue Jul 26 21:16:41 2022, Koji, Update, Computer Scripts / Programs, Vector fitting 
Entry  Mon Jul 25 18:22:30 2022, Deeksha, Summary, Wiki, Measured the PZT TF Successfully  6x
Entry  Mon Jul 25 09:37:39 2022, Deeksha, Update, Electronics, Using the DFD to measure PZT TF ag4395.jpegdfd.jpeg
Entry  Mon Jul 18 04:42:54 2022, Anchal, Update, Calibration, Error propagation to astrophysical parameters from detector calibration uncertainty BNSparamsErrorwrtfdError-merged.pdfBBHparamsErrorwrtfdError-merged.pdfBNSparamsEPSwrtCalError.pdfBBHparamsEPSwrtCalError.pdf
    Reply  Mon Jul 18 15:17:51 2022, Hang, Update, Calibration, Error propagation to astrophysical parameters from detector calibration uncertainty 
       Reply  Tue Jul 19 07:34:46 2022, Anchal, Update, Calibration, Error propagation to astrophysical parameters from detector calibration uncertainty BNSparamsErrorwrtfdError.pdfBBHparamsErrorwrtfdError.pdfBNSparamsEPSwrtCalError.pdfBBHparamsEPSwrtCalError.pdf
          Reply  Sun Jul 24 08:56:01 2022, Hang, Update, Calibration, Error propagation to astrophysical parameters from detector calibration uncertainty 
Entry  Fri Jul 22 17:43:19 2022, Koji, Update, General, Obtained a functional CRT PXL_20220723_003631871.jpg
Entry  Tue Jul 19 17:18:34 2022, JC, Update, Electronics, New Coil Driver on Rack 1X3 22DC1767-6073-4D82-BEED-915318B57C03.jpeg
Entry  Mon Jul 11 11:56:40 2022, he Yehonathan, Update, BHD, MICH AS55 noise budget Control_Diagram.pdfMICH_AS55_Noise_Budget.pdf
    Reply  Tue Jul 12 09:14:50 2022, rana, Update, BHD, MICH AS55 noise budget 
       Reply  Wed Jul 13 10:54:39 2022, Yehonathan, Update, BHD, MICH AS55 noise budget BS_MICH_ACtuation_Calibration.pdfMICH_AS55_Model_Measurement_Comparison.pdfMICH_AS55_Noise_Budget.pdf
          Reply  Wed Jul 13 13:30:48 2022, Yehonathan, Update, BHD, add Laser RIN to MICH budget 
             Reply  Mon Jul 18 16:49:57 2022, Yehonathan, Update, BHD, add Laser RIN to MICH budget Laser_RIN.pdfMICH_AS55_Noise_Budget.pdf
                Reply  Mon Jul 18 18:33:38 2022, Koji, Update, BHD, add Laser RIN to MICH budget 
Entry  Sat Jul 16 02:44:10 2022, Koji, Update, IOO, IMC servo tuning ErrorPSD.pdfOLTF.pdfScreen_Shot_2022-07-16_at_03.59.05.png
Entry  Fri Jul 15 16:20:16 2022, Cici Hanna, Update, General, Finding UGF UGF_4042.pngUGF_5650.pngTFSR785_29-06-2022_114042.txtTFSR785_29-06-2022_115650.txt
Entry  Wed Jul 13 07:16:48 2022, JC, Update, Electronics, Checking Sorensen Power Supplies 658C5D39-11BD-4EE3-90E2-34CBBC1DBD3C.jpeg5328312A-7918-44CC-82B7-54B57840A336.jpeg
    Reply  Fri Jul 15 12:21:58 2022, JC, Update, Electronics, Checking Sorensen Power Supplies 50DF21D7-D61A-4674-B0DA-463378B00ADB.jpegFA4CF579-6C1E-48D5-B152-74F35B4EE90B.jpeg
Entry  Thu Jul 14 19:56:15 2022, rana, Update, IOO, mc wfs demod mcwfs-steps.pdf
Entry  Thu Jul 14 19:09:51 2022, rana, Update, General, EQ recovery ETMY-screen.png
Entry  Wed Jul 13 18:58:17 2022, Koji, Update, IOO, IMC suspecion 
Entry  Tue Jul 12 14:56:17 2022, Tomislav, Summary, Electronics, Electronics noise measurements 23x
    Reply  Wed Jul 13 13:26:44 2022, rana, Summary, Electronics, Electronics noise measurements 
Entry  Wed Jul 13 12:49:25 2022, Paco, Summary, SUS, SUS frozen 
Entry  Tue Jul 12 19:46:54 2022, Paco, Summary, ALS, How (not) to take NPRO PZT transfer function 
Entry  Tue Jul 12 18:35:31 2022, Cici Hanna, Summary, General, Finding Zeros/Poles With Vectfit 
Entry  Tue Jul 12 13:59:12 2022, rana, Summary, Computers, process monitoring: Monit 
Entry  Tue Jul 12 09:25:09 2022, rana, Update, IOO, IMC WFS 
Entry  Mon Jul 11 19:29:23 2022, Paco, Summary, General, Finalizing recovery -- timing issues, cds, MC1 
Entry  Mon Jul 11 15:26:12 2022, JC, HowTo, VAC, Startup after Power Outage 
    Reply  Mon Jul 11 17:41:52 2022, Koji, HowTo, VAC, Startup after Power Outage Screen_Shot_2022-07-11_at_18.13.00.png
Entry  Tue Apr 12 09:05:21 2022, Jordan, Update, VAC, New Pressure Gauge Install/Pump Spool Vent 6x
    Reply  Wed Apr 13 12:50:07 2022, Tega, Update, VAC, New Pressure Gauge Install/Pump Spool Vent VAC_FRG_UPGRADE.png
       Reply  Thu Apr 21 16:36:56 2022, Tega, Update, VAC, cleanup work for vacuum git repo 
          Reply  Tue May 24 10:37:09 2022, Tega, Update, VAC, added FRG channels to slow channel ini file 
             Reply  Mon Jul 11 17:25:43 2022, Tega, Update, VAC, fixed obsolete reference bug in serial_XGS600 service 
Entry  Mon Jul 11 11:16:45 2022, JC, Summary, Electronics, Startup after Shutdown 
Entry  Fri Jul 8 23:10:04 2022, Koji, Summary, General, July 9th, 2022 Power Outage Prep  
Entry  Fri Jul 8 14:03:33 2022, JC, HowTo, VAC, Vacuum Preparation for Power Shutdown  Screen_Shot_2022-07-12_at_7.02.14_AM.png
Entry  Wed Sep 29 17:10:09 2021, Anchal, Summary, CDS, c1teststand problems summary c1teststand_issues_summary.pdf
    Reply  Thu Sep 30 14:09:37 2021, Anchal, Summary, CDS, New way to ssh into c1teststand 
       Reply  Thu Mar 3 15:37:40 2022, Anchal, Summary, CDS, c1teststand restructured 
    Reply  Mon Oct 4 11:05:44 2021, Anchal, Summary, CDS, c1teststand problems summary 
       Reply  Mon Oct 4 18:00:16 2021, Koji, Summary, CDS, c1teststand problems summary 
          Reply  Tue Oct 5 17:58:52 2021, Anchal, Summary, CDS, c1teststand problems summary 
       Reply  Tue Oct 5 18:00:53 2021, Anchal, Summary, CDS, c1teststand time synchronization working now 
          Reply  Mon Oct 11 17:31:25 2021, Anchal, Summary, CDS, Fixed mounting of mx devices in fb. daqd_dc is running now. 
             Reply  Mon Oct 11 18:29:35 2021, Anchal, Summary, CDS, Moving forward? 
                Reply  Tue Oct 12 17:20:12 2021, Anchal, Summary, CDS, Connected c1sus2 to martian network 
                   Reply  Tue Oct 12 23:42:56 2021, Koji, Summary, CDS, Connected c1sus2 to martian network 
                      Reply  Wed Oct 13 11:25:14 2021, Anchal, Summary, CDS, Ran c1sus2 models in martian CDS. All good! CDS_screens_running.png
                         Reply  Tue Oct 19 18:20:33 2021, Ian MacMillan, Summary, CDS, c1sus2 DAC to ADC test data3_Plots.pdfdata2_Plots.pdf
                            Reply  Tue Oct 19 23:43:09 2021, Koji, Summary, CDS, c1sus2 DAC to ADC test P_20211019_224433.jpgP_20211019_224122.jpgP_20211019_224400.jpgP_20211019_224411.jpg
                               Reply  Wed Oct 20 11:48:27 2021, Anchal, Summary, CDS, Power supple configured correctly. 
                               Reply  Tue Oct 26 18:24:00 2021, Ian MacMillan, Summary, CDS, c1sus2 DAC to ADC test data2_Plots.pdfdata3_Plots.pdf
                         Reply  Wed Dec 22 17:40:22 2021, Anchal, Summary, CDS, c1su2 model updated with SUS damping blocks for 7 SOSs 
                            Reply  Wed Dec 29 20:09:40 2021, rana, Summary, CDS, c1su2 model updated with SUS damping blocks for 7 SOSs 
                            Reply  Fri Mar 4 11:04:34 2022, Anchal, Summary, CDS, c1susaux2 system setup and running 40mBHD_C1SUSAUX2_Acromag_Chassis.pdf
                               Reply  Mon Mar 7 19:38:47 2022, Anchal, Summary, CDS, c1susaux2 slow controls issues 
                               Reply  Mon Mar 14 12:20:05 2022, Anchal, Summary, CDS, c1susaux2 slow controls acromag chassis installed BHD_WatchDogs.png40mBHD_C1SUSAUX2_Acromag_Chassis.pdf
                                  Reply  Thu Mar 17 19:12:44 2022, Anchal, Summary, CDS, c1auxey1 slow controls acromag chassis installed, not powered 
                                     Reply  Fri Mar 18 18:39:13 2022, Yehonathan, Summary, CDS, c1auxey1 slow controls acromag chassis installed, powered 
                                        Reply  Fri Mar 18 19:10:51 2022, Anchal, Summary, CDS, c1auxey1 slow controls issues 
                                           Reply  Mon Mar 21 18:42:06 2022, Anchal, Summary, CDS, c1auxey1 slow controls issues 
                                  Reply  Mon Apr 4 17:03:47 2022, Anchal, Summary, CDS, c1susaux2 slow controls acromag chassis fixed and installed Screenshot_2022-04-04_17-03-26.png
                                     Reply  Wed Jul 6 22:40:03 2022, Tega, Summary, CDS, Use osem variance to turn off SUS damping instead of coil outputs 
                                        Reply  Thu Jul 7 21:25:48 2022, Tega, Summary, CDS, Use osem variance to turn off SUS damping instead of coil outputs 
                            Reply  Tue Mar 15 11:52:34 2022, Anchal, Summary, CDS, c1su2 model updated for sending Run/Acquire Binary Output to Binary Interface card c1su2.pdf
                               Reply  Tue Mar 15 14:10:41 2022, Anchal, Summary, CDS, c1su2 model remade, reinstalled, restarted after the update 
             Reply  Tue Oct 12 17:10:56 2021, Anchal, Summary, CDS, Some more information 
Entry  Wed Jul 6 19:58:16 2022, Paco, Summary, NoiseBudget, XARM noise budget xarm_nb_2022_07.pdf
Entry  Wed Jul 6 18:51:20 2022, Deeksha, Update, Electronics, Measuring the Transfer Function of the PZT pzt_transfer_fn.pngckt_diagram.jpegMokuPhaseMeterTFData_20220706_174753_TF_Data.txt
Entry  Wed Jul 6 15:28:18 2022, Tega, Update, SUS, Output matrix diagonalisation : F2P coil balancing 
Entry  Tue Jul 5 20:05:06 2022, Tomislav, Update, Electronics, Whitening electronics noise whitening_noises.png
Entry  Fri Jul 1 12:49:52 2022, Koji, Update, IOO, MC2 seemed misaligned / fixed C1-MULTI_FBDB3F_TIMESERIES-1340668818-86400.pngC1-LOCKED_MC_5E4267_TIMESERIES-1340668818-86400.png
Entry  Thu Jun 30 19:24:24 2022, rana, Summary, PEM, effect of nearby CES construction 
Entry  Thu Jun 30 18:06:22 2022, Paco, Update, ALS, Optimum ALS recovery - part I als_ool_06_2022.png
    Reply  Thu Jun 30 19:04:55 2022, rana, Summary, PSL, PSL HEPA: How what when why 
Entry  Thu Jun 30 17:19:55 2022, Deeksha, Summary, Electronics, Measured Transfer Functions of the Control Loop, Servo (OLTF); got Vectfit working  TFSR785_29-06-2022_114042.pdfTFSR785_29-06-2022_114650.pdfTF_OLG_vectfit.png
Entry  Tue Jun 28 18:19:09 2022, Tomislav, Update, Electronics, Electronics noise electronics_noise_spectra.pngerror_signal.png
    Reply  Wed Jun 29 18:53:38 2022, rana, Update, Electronics, Electronics noise 
Entry  Tue Jun 28 16:59:35 2022, Paco, Summary, ALS, ALS beat allan deviation (XARM) xbeat_1340469968.pdffrac_avar_xbeat.pdf
    Reply  Tue Jun 28 18:53:16 2022, rana, Summary, ALS, ALS beat allan deviation (XARM) 
       Reply  Wed Jun 29 14:28:06 2022, Paco, Summary, ALS, ALS beat allan deviation (XARM) frac_adev_xbeat.pdf
Entry  Tue Jun 28 23:10:34 2022, Yehonathan, Update, BHD, Measurement of AS55 demod board conversion factor 
Entry  Tue Jun 28 22:27:11 2022, Yehonathan, Update, BHD, Measurement of input and output electronics noise input_noise_spectrum.pdfoutput_noise_spectrum.pdf
Entry  Tue Jun 28 17:07:47 2022, Anchal, Update, Calibration, Added Beatnote channels in demodulation of c1cal 
Entry  Tue Jun 28 16:26:58 2022, Cici, Summary, General, Vector fitting open loop transfer function/Audio cancellation of optical table enclosure vectfit_firstattempt.pngTFSR785_28-06-2022_161937.pdfenclosure_open.MP4enclosure_closed.MP4
Entry  Tue Jun 21 21:17:16 2022, yuta, Update, BHD, RTS models for BHD added but PCIE error remaining Screenshot_2022-06-21_20-12-55_C1HPC.pngScreenshot_2022-06-21_20-14-56_C1SU2.pngScreenshot_2022-06-21_20-13-38_C1LSC.pngScreenshot_2022-06-21_20-34-44_RED.png
    Reply  Wed Jun 22 14:44:03 2022, Anchal, Update, BHD, Fixed DC error in c1su2, added new library model for suspensions 
       Reply  Tue Jun 28 14:24:23 2022, yuta, Update, BHD, BHD DC PD signals now also sent to c1lsc to circumvent IPC error C1LSC.JPGC1SUS2.JPGScreenshot_2022-06-28_16-03-16_BHDDCPDcopied.png
Entry  Tue Jun 28 09:03:58 2022, JC, Update, General, Organizing and Cleaning 
Entry  Mon Jun 27 18:54:27 2022, yuta, Update, LSC, Modulation depths measurement using Yarm cavity scan YarmModIndex.png
Entry  Mon Jun 27 13:39:40 2022, Deeksha, Update, Electronics, Setting up the MokuLab WhatsApp_Image_2022-06-24_at_5.21.28_PM.jpeg
Entry  Mon Jun 27 13:25:50 2022, Cici, Update, General, Characterizing the Transfer Loop TF_measurement_b.pngtransfer_function_mag_fit.pngtransfer_function_phase_fit.pngcontrol_flow.png
Entry  Fri Jun 24 12:13:16 2022, JC, Update, IOO, WFS issues WFS.png
    Reply  Sat Jun 25 14:29:48 2022, Anchal, Update, IOO, WFS issues 
       Reply  Sat Jun 25 20:23:59 2022, Koji, Update, IOO, WFS issues Screen_Shot_2022-06-25_at_20.23.21.pngScreen_Shot_2022-06-25_at_20.29.24.png
          Reply  Mon Jun 27 12:32:45 2022, yuta, Update, IOO, WFS issues fixed 
Entry  Sat Jun 25 22:18:41 2022, Tomislav, Update, ASC, Simulation and reality comparisons sens_output_comparison_23_6_new.pngcontr_out_comparison_23_6_new.pnglocal_damp_out_comp_23_6_new.png
Entry  Fri Jun 24 17:16:59 2022, Paco, Update, ALS, XAUX cable in control room 
Entry  Tue May 4 19:14:43 2021, Yehonathan, Update, General, OSEMs from KAGRA 
    Reply  Fri Jun 24 13:29:37 2022, Yehonathan, Update, General, OSEMs from KAGRA 
Entry  Thu Jun 23 15:05:01 2022, Water Monitor, Update, Upgrade, Water Bottle Refill 
Entry  Wed Jun 22 18:55:31 2022, yuta, Update, LSC, Daily alignment work; POY trouble solved Screenshot_2022-06-22_17-17-42_XYaligned.pngScreenshot_2022-06-22_18-58-26_Transmission.png
    Reply  Wed Jun 22 19:41:13 2022, Koji, Update, LSC, Daily alignment work; POY trouble solved 
Entry  Wed Jun 22 17:04:06 2022, Deeksha, Summary, Electronics, Characterising the AUX control loop after.jpegbefore.jpegfreq_response.png
Entry  Tue Jun 21 22:22:37 2022, Tomislav, Update, ASC, Plots sens_output_comparison_with_air_turbulence.png
Entry  Tue Jun 21 18:41:46 2022, Tomislav, Update, ASC, Simulation plot sens_output_comparison.png
Entry  Tue Jun 21 14:59:22 2022, Cici, Summary, General, AUX Transfer Function Loop Exploration 
Entry  Tue Jun 14 18:45:43 2022, Anchal, Update, SUS, LO2 lower magnets are stuck in coil, won't come off 
    Reply  Tue Jun 14 19:34:06 2022, yuta, Update, SUS, Resonant frequency identification from the free swing test 7x
       Reply  Thu Jun 16 18:30:07 2022, Anchal, Update, SUS, New diagonalized input matrices applied SUSInpMatDiag_MC1_MC2_MC3_BS_IMTX_ETMX_ETMY_AS1_AS4_SR2_PR2_PR3.pdf
          Reply  Tue Jun 21 08:36:50 2022, Anchal, Update, SUS, Diagonalized input matrices for LO1, freeSwing on ITMY and ITMX SUSInpMatDiag_LO1.pdf
    Reply  Wed Jun 15 15:07:07 2022, Koji, Update, SUS, LO2 SUS stuck fixed Screenshot_2022-06-15_15-00-22.pngScreenshot_2022-06-15_15-00-40.png
Entry  Mon Jun 20 19:46:04 2022, Tomislav, Update, ASC, Simulation plots pit_mot_cl_MCs.pngloc_damp_cl_MCs.pngcontr_output_cl_MCs.pngsens_output_cl_MCs.pngBS_motion_cl_MCs.png
Entry  Thu Apr 7 11:47:22 2022, Yehonathan, Update, BHD, Initial BHD modeling: AS - LO mode matching 
    Reply  Thu Apr 7 21:15:04 2022, Yehonathan, Update, BHD, Initial BHD modeling: AS - LO mode matching 
       Reply  Mon May 16 16:13:01 2022, Yehonathan, Update, BHD, Initial BHD modeling: Damped suspension model Damped_SUS.pngETMY_SUSPOS_GOL.pdfSUS_Response.png
          Reply  Thu Jun 16 17:40:15 2022, Yehonathan, Update, BHD, Comparison of MICH OLTF model with measurement MICH_Model_Measurement_Comparison.pdf
             Reply  Fri Jun 17 12:05:32 2022, Yehonathan, Update, BHD, Comparison of MICH OLTF model with measurement 
                Reply  Fri Jun 17 13:07:08 2022, Koji, Update, BHD, Comparison of MICH OLTF model with measurement 
Entry  Thu Jun 16 19:49:48 2022, Cici, Update, General, Using the SR785 
Entry  Wed Jun 15 15:03:41 2022, Koji, Update, PSL, PMC input beam aligned Screenshot_2022-06-15_15-03-16.pngPXL_20220615_212304650.jpg
    Reply  Thu Jun 16 15:29:03 2022, yuta, Update, PSL, PMC input beam aligned again, IMC  Screenshot_2022-06-16_15-27-30.png
Entry  Wed Jun 15 17:12:39 2022, Cici, Summary, General, Preparation for AUX Loop Characterization 
Entry  Tue May 24 11:04:53 2022, JC, Update, VAC, Beginning Pumpdown PUMPDOWN-2022-05-24_16-57-59.pngC1VAC_Screenshot_2022-05-24_16-59-27.png
    Reply  Wed May 25 16:38:27 2022, yuta, Update, SUS, Suspensions quick health check Screenshot_2022-05-25_16-46-13.pngOSEMcheck.JPG
       Reply  Tue Jun 7 17:26:21 2022, yuta, Update, SUS, ITMY ULCOIL mystery not solved ULCoilInductance.JPGULCoilResistance.JPGWrongSetting.JPG
          Reply  Tue Jun 7 19:13:12 2022, yuta, Update, SUS, Agreement on suspension damping loop polarity conventions NoteBeforeChanges.JPG
             Reply  Fri Jun 10 15:02:04 2022, yuta, Update, SUS, Servo gain sign flipped for MC1 WFS relief Screenshot_2022-06-10_15-04-46.png
          Reply  Tue Jun 7 19:40:45 2022, Anchal, Update, SUS, ITMY changed output matrix to disable use of UL coil ITMY_PIT_to_POS-PIT-YAW_Coupling.pdfITMY_YAW_to_POS-PIT-YAW_Coupling.pdf
          Reply  Wed Jun 8 18:16:20 2022, yuta, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test Screenshot_2022-06-08_18-10-44.pngSWAP.JPG
             Reply  Thu Jun 9 23:08:39 2022, rana, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test 
                Reply  Fri Jun 10 13:02:14 2022, yuta, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test 
                   Reply  Fri Jun 10 15:04:23 2022, rana, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test 
                      Reply  Fri Jun 10 21:10:01 2022, yuta, Update, SUS, ITMY ULCOIL mystery: Coil driver swap test 
                         Reply  Wed Jun 15 17:03:17 2022, yuta, Update, SUS, ITMY ULCOIL issue solved, loose connection in sat amp box Measured16Ohms.JPGSatAmpTerminator.JPGBAD.JPGSUCCESSFUL_KICK.png
       Reply  Wed Jun 15 15:45:37 2022, yuta, Update, SUS, LO1 LLCOIL now working, it was loose connection Measurement.JPGBAD.JPGScreenshot_2022-06-15_15-59-05.png
    Reply  Wed Jun 15 07:26:35 2022, JC, Update, VAC, Beginning Pumpdown 
Entry  Fri Jun 10 20:11:46 2022, yuta, Update, ASC, Yarm ASS re-tuning in progress Screenshot_2022-06-10_20-10-52.png
    Reply  Mon Jun 13 20:26:09 2022, yuta, Update, ASC, Yarm ASS re-tuning in progress -part 2- Screenshot_2022-06-13_20-47-12.pngScreenshot_2022-06-13_20-44-43.png
       Reply  Tue Jun 14 20:57:15 2022, Anchal, Update, ASC, Yarm ASS working now 
Entry  Tue Jun 14 08:41:36 2022, JC, Update, OPLEV Tables, BS Oplev Table Sketch BS_OPLEV_Table.PNG
Entry  Fri Jun 10 13:52:22 2022, JC, Update, OPLEV Tables, ITMX, ITMY, and Vertex Table Beam Paths DCE4F1D7-5AE0-491C-8AF6-F8B659C0787E_1_105_c.jpeg4B24C891-654D-4C51-A8D9-D316364FCF68_1_105_c.jpegF5B115E5-885F-463C-9645-BB2EB73B6144_1_201_a.jpeg
Entry  Wed Jun 8 16:57:46 2022, Koji, Update, IOO, Power Outage 220608: IMC restored 
Entry  Wed Jun 8 16:33:26 2022, Koji, Update, General, Power Outage 220608: HVAC restored 
Entry  Wed Jun 8 16:03:12 2022, Koji, Update, VAC, Power Outage 220608: Vacuum Recovery Screenshot_2022-06-08_16-43-13.png
Entry  Tue Jun 7 18:32:46 2022, Deeksha, Update, Electronics, Noise Budgeting ADC (of redpitaya) ch1_0.5V.pngch2_0.0V.png
Entry  Mon Jun 6 21:01:22 2022, yuta, Update, IMC, MC1 OSEM sensor sign flipped, MC1/2/3 free swinging overnight for inmat diagonalization Screenshot_2022-06-06_21-05-28.png
    Reply  Mon Jun 6 22:08:55 2022, Koji, Update, IMC, MC1 OSEM sensor sign flipped, MC1/2/3 free swinging overnight for inmat diagonalization 
Entry  Mon Jun 6 16:09:23 2022, rana, Configuration, DetChar, Summary Pages: seis BLRMS 
Entry  Mon Jun 6 09:37:16 2022, JC, Update, SUS, InMatCalc 
Entry  Wed Jun 1 12:56:44 2022, Paco, Summary, Electronics, STEMlab 125 handout 
Entry  Tue May 31 17:30:01 2022, Yehonathan, Update, BHD, Green shutters fixed 
    Reply  Wed Jun 1 11:56:28 2022, yuta, Update, ALS, Shutter driver for GRY replaced Screenshot_2022-06-01_12-01-53.png
Entry  Fri May 27 12:15:30 2022, JC, Update, Electronics, CRT TV / Monitor 6 
    Reply  Tue May 31 14:44:02 2022, JC, Update, Electronics, CRT TV / Monitor 6 
Entry  Fri May 27 17:46:48 2022, Paco, Summary, Computers, CDS upgrade visit, downfall and rise of c1lsc models 
Entry  Mon May 16 14:46:35 2022, Tommy, Update, Electronics, RFSoC MTS Work 
    Reply  Fri May 27 15:53:17 2022, Tommy, Update, Electronics, RFSoC MTS Work 
Entry  Thu May 26 15:55:10 2022, Tommy, Update, Electronics, RFSoC Power Spectrum Screen_Shot_2022-06-02_at_2.51.23_PM.png
Entry  Tue May 3 21:05:23 2022, yuta, Update, BHD, AS path alignment, removing a lot of green stuff 7x
    Reply  Wed May 4 13:09:42 2022, Anchal, Update, BHD, IMC table balanced again, IMC is locking, YARM is locking 
       Reply  Wed May 4 15:08:59 2022, Tega, Update, BHD, XARM alignment to get flashing IFO_XY_ARMS_Flashing.png
          Reply  Wed May 4 18:52:43 2022, Tega, Update, BHD, POP beam too high at POP SM4 on the ITMX chamber snnp_pr2_pr3_itmy_aligment.png
             Reply  Thu May 5 14:46:22 2022, Anchal, Update, BHD, POP beam height lowered, POP_SM4 raised 
                Reply  Thu May 5 17:05:31 2022, Tega, Update, BHD, IMC & X/Y-arm alignment IFO_aligment_Y_locking_on.png
                Reply  Mon May 9 18:43:03 2022, Anchal, Update, BHD, ITMX table layout corrected 
                   Reply  Mon May 9 18:49:05 2022, Tega, Update, BHD, Relocate green TRX and TRY PDs/cams/optics from PSL table to BS table IMG_20220509_184439943.jpgIMG_20220509_184154722.jpg
                      Reply  Tue May 10 15:46:38 2022, JC, Update, BHD, Relocate green TRX and TRY components from PSL table to BS table IMG_0741.jpegIMG_0753.jpeg
                         Reply  Tue May 10 18:25:43 2022, Paco, Update, BHD, Green Transmission path 
                   Reply  Tue May 10 16:31:14 2022, Tega, Update, BHD, ITMX optlev return beam steered to QPD 
       Reply  Fri May 6 13:48:34 2022, Anchal, Update, BHD, WFS loop instability fixed 
    Reply  Thu May 12 19:55:01 2022, Tega, Update, BHD, AS path alignment AS.JPGOMCchamber.JPG
       Reply  Thu May 12 20:11:18 2022, Anchal, Update, BHD, BHDBS Output beams steered out to ITMY table signal-2022-05-12-201844.jpeg
          Reply  Thu May 12 20:24:29 2022, yuta, Update, BHD, POX and POY investigation POY.JPG
       Reply  Mon May 16 13:22:59 2022, yuta, Update, BHD, REFL and AS paths aligned at AP table REFLPOP.JPGPOPAS.JPG
          Reply  Mon May 16 19:14:17 2022, Anchal, Update, BHD, Camera set on AS path and BHDBS output path 
             Reply  Tue May 17 18:43:38 2022, Anchal, Update, BHD, Placed SRM in ITMY Chamber 
                Reply  Wed May 18 08:30:29 2022, Paco, Update, BHD, SRM OpLev 
                   Reply  Thu May 19 08:51:40 2022, Paco, Update, BHD, SRM OpLev 
                Reply  Wed May 18 09:02:52 2022, Anchal, Update, BHD, WFS1 PD centered 
                Reply  Wed May 18 17:23:15 2022, Anchal, Update, BHD, Placed PRM in BS Chamber 
                   Reply  Thu May 19 18:56:08 2022, yuta, Update, BHD, Current OSEM sensor values with all the suspensions aligned OSEMS.txt
                   Reply  Thu May 19 19:05:59 2022, Anchal, Update, BHD, BS Chamber all work finished, BHD path setup 
                      Reply  Fri May 20 20:03:48 2022, Paco, Update, BHD, ITMY chamber work finished - LO and AS overlapped Screenshot_2022-05-20_20-38-25.pngOSEMs.txt
                         Reply  Mon May 23 13:16:59 2022, Paco, Update, BHD, End of vent - checks OSEMs20220523.txtScreenshot_2022-05-23_13-24-06_IFOaligned_GTRY_still_clipping_but_less.pngPR3position.JPG
                            Reply  Tue May 24 15:21:13 2022, Anchal, Update, BHD, Freeswing tests of new SOS started 
Entry  Fri May 20 12:42:23 2022, Tega, Update, VAC, Door installation on the end stations 
Entry  Sat May 14 08:36:03 2022, Chris, Update, DAQ, DAQ troubleshooting 
    Reply  Mon May 16 10:49:01 2022, Anchal, Update, DAQ, DAQ troubleshooting 
       Reply  Mon May 16 12:59:27 2022, Chris, Update, DAQ, DAQ troubleshooting timeseries.pngerr.png
Entry  Fri May 13 14:26:00 2022, JC, Update, Alignment, LO2 Beam 
    Reply  Fri May 13 18:42:13 2022, Paco, Update, Alignment, ITMX and ITMY sat amp failures 
Entry  Thu May 12 13:46:59 2022, Jc, Update, Alignment, POP Beam IMG_0777.jpeg
    Reply  Thu May 12 17:20:08 2022, Paco, Update, Alignment, POP Beam on CCD PXL_20220513_002047233.jpg
Entry  Wed May 11 15:49:42 2022, JC, Update, OPLEV Tables, Green Beam OPLEV Alignment IMG_0770.jpeg
Entry  Mon May 9 22:19:06 2022, Koji, Update, BHD, BHD Platform Progress status Screenshot_2022-05-09_220220.pngScreenshot_2022-05-09_222405.png
    Reply  Mon May 9 23:18:44 2022, Koji, Update, BHD, BHD Platform Progress status 6x
Entry  Mon Apr 18 16:09:07 2022, Yehonathan, Update, BHD, BHD Readout simulation BHD_Simulink_Sketch.drawio.pdf
    Reply  Tue May 3 21:07:17 2022, Yehonathan, Update, BHD, BHD Readout simulation 
       Reply  Thu May 5 17:50:48 2022, Yehonathan, Update, BHD, BHD Readout simulation BHD_controls_40m_MICH.pdf
Entry  Tue Feb 1 15:33:28 2022, Koji, Summary, BHD, Optomechanics configuration for the in-vacuum aux small optics Invac_opto_mechanics_v2.pdf
    Reply  Wed Feb 2 18:55:58 2022, Koji, Summary, BHD, Optomechanics configuration for the in-vacuum aux small optics Screen_Shot_2022-02-02_at_6.46.46_PM.png
       Reply  Wed Feb 2 21:16:23 2022, Koji, Summary, BHD, Optomechanics configuration for the in-vacuum aux small optics PXL_20220203_050156031.jpg
       Reply  Thu Apr 28 11:53:10 2022, Anchal, Summary, BHD, POP_SM4 and POP_SM5 Assembly 
          Reply  Tue May 3 14:02:09 2022, Anchal, Summary, BHD, Installed POP path in ITMX Chamber 
    Reply  Thu Apr 14 10:18:35 2022, Paco, Summary, BHD, 2 in oplev mirrors incompatible with LMR2V 
       Reply  Thu Apr 14 18:34:51 2022, Paco, Summary, BHD, ITMY Oplev reinstalled (Re: 2 in oplev mirrors incompatible with LMR2V) 
Entry  Fri Apr 29 08:34:40 2022, JC, Update, VAC, RGA Pump Down Screen_Shot_2022-04-29_at_8.46.53_AM.png
    Reply  Tue May 3 13:18:47 2022, JC, Update, VAC, RGA Pump Down 
Entry  Thu Apr 21 18:18:42 2022, yehonathan, Update, BHD, POX Alignment POX11_alignment.png
    Reply  Thu Apr 28 17:45:53 2022, Anchal, Update, BHD, POX Beam issues PXL_20220429_002703686.jpg
       Reply  Sat Apr 30 13:29:33 2022, Paco, Update, BHD, POX Beam issues --- fixed, ASL alignment on vertex chamber 
          Reply  Mon May 2 17:51:30 2022, Anchal, Update, BHD, POX Beam aligned on RFPD, YARM locked 
Entry  Wed Apr 27 10:05:55 2022, JC, Update, Coil Drivers, Coil Drivers Update 
    Reply  Mon May 2 13:30:52 2022, JC, Update, Coil Drivers, Coil Drivers Update 
Entry  Fri Apr 22 14:14:33 2022, Jordan, Update, VAC, TP3 Forepump tip seal replacement IMG_0572.jpegIMG_0573.jpeg
    Reply  Mon May 2 10:00:34 2022, Jordan, Update, VAC, TP3 Forepump tip seal replacement 
Entry  Wed Apr 27 16:28:57 2022, Anchal, Summary, BHD, BHD Upgrade - Retreiving arm cavity alignment 
    Reply  Thu Apr 28 09:12:18 2022, Anchal, Update, BHD, Restoring arm alignment 
       Reply  Thu Apr 28 18:07:04 2022, Anchal, Update, BHD, Restoring arm alignment at EOD 
Entry  Tue Apr 26 16:23:22 2022, Tommy, Update, Electronics, RFSoC2x2 MTS 
Entry  Mon Apr 25 18:00:03 2022, Ian MacMillan, Update, Upgrade, Cable supports update Chamber_Leg_Ribbon_Cable_Attachments.pdf
Entry  Thu Apr 21 10:35:23 2022, Koji, Update, CDS, DAQ seemed down 
    Reply  Mon Apr 25 17:24:06 2022, Anchal, Update, CDS, DAQ still down 
Entry  Tue Apr 19 18:10:10 2022, Paco, Update, BHD, Part V of BHR upgrade - POX11 path, LO path, and ITMX Oplev DJI_0167.JPGDJI_0169.JPGDJI_0168.JPG
    Reply  Wed Apr 20 08:20:22 2022, Paco, Update, BHD, Part V of BHR upgrade - PR2 weirdness 
       Reply  Wed Apr 20 18:50:03 2022, Koji, Update, BHD, Part V of BHR upgrade - PR2 weirdness Screenshot_2022-04-20_18-46-11.png
    Reply  Thu Apr 21 16:49:01 2022, Paco, Update, BHD, Part V of BHR upgrade - BS Oplev + LO1 offset 
       Reply  Thu Apr 21 18:42:47 2022, Tega, Update, BHD, Part V of BHR upgrade - Align LO and AS beams to BHD BS 
          Reply  Thu Apr 21 20:33:31 2022, Koji, Update, BHD, AS1 UR OSEM problem localized in the chamber Screenshot_from_2022-04-21_20-13-13.png
             Reply  Fri Apr 22 12:03:09 2022, Tega, Update, BHD, AS1 UR OSEM problem localized in the chamber 
                Reply  Fri Apr 22 12:15:08 2022, Anchal, Update, BHD, Cable post installation 
                   Reply  Mon Apr 25 16:57:57 2022, Anchal, Update, BHD, Cable post installation 
Entry  Mon Apr 25 14:19:51 2022, JC, Update, General, Nitrogen Tank 
    Reply  Mon Apr 25 14:49:02 2022, Koji, Update, General, Nitrogen Tank 
Entry  Sun Apr 24 13:17:08 2022, Tommy, Update, Electronics, New RFSoC2x2 Overlay 
Entry  Mon Apr 18 14:52:47 2022, Ian MacMillan, Summary, SEI, Seismic Study of Buildings and Caltech Campus 7x
    Reply  Thu Apr 21 17:32:35 2022, Ian MacMillan, Summary, SEI, Seismic Study of Buildings and Caltech Campus IMG_1820.jpgScreen_Shot_2022-04-21_at_5.52.51_PM.png
Entry  Wed Apr 20 16:11:08 2022, Koji, Update, SUS, Outpur resistors updated for LO1 coil drivers / for SR2, LO2, AS1, and AS4 in progress 6x
    Reply  Thu Apr 21 15:22:44 2022, Koji, Update, SUS, Outpur resistors updates for SR2, LO2, AS1, and AS4 done 
Entry  Thu Apr 21 11:31:35 2022, JC, Update, VAC, Gauges P3/P4 IMG_0560.jpegIMG_0561.jpeg
Entry  Tue Mar 1 16:01:14 2022, Paco, Update, Electronics, RFSoC 2x2 board -- setup for remote work & BALUN saga balun_adc1.pngPXL_20220302_001734121.jpg
    Reply  Thu Apr 7 20:33:42 2022, Tommy, Update, Electronics, RFSoC 2x2 board -- setup for remote work 
    Reply  Fri Apr 8 16:03:58 2022, rana, Update, Electronics, RFSoC 2x2 board -- setup for remote work & BALUN saga 
       Reply  Wed Apr 20 14:56:06 2022, Tommy, Update, Electronics, RFSoC 2x2 board -- setup for remote work & BALUN saga 
Entry  Mon Apr 18 15:17:31 2022, Jancarlo, Update, General, Tool box and Work Station Organization 
    Reply  Mon Apr 18 23:22:39 2022, Koji, Update, General, Tool box and Work Station Organization PXL_20220419_062101907.jpg
Entry  Mon Oct 25 13:23:45 2021, Anchal, Summary, BHD, Before photos of BSC 
    Reply  Mon Oct 25 17:37:42 2021, Anchal, Summary, BHD, Part I of BHR upgrade - Removed optics from BSC rn_image_picker_lib_temp_44cb790a-c3b4-42aa-8907-2f9787a02acd.jpgrn_image_picker_lib_temp_0fd8f4fd-64ae-4ccd-8422-cfe929d4eeee.jpg
       Reply  Tue Oct 26 16:56:22 2021, Paco, Summary, BHD, Part I of BHR upgrade - Locked PMC and IMC 
          Reply  Wed Oct 27 16:27:16 2021, Anchal, Summary, BHD, Part II of BHR upgrade - Prep OMCNorthBefore.jpegOMCNorthAfter.jpeg
             Reply  Wed Oct 27 16:31:35 2021, Anchal, Summary, BHD, Part III of BHR upgrade - Removal of PR2 Small Suspension 
                Reply  Thu Oct 28 16:32:32 2021, Paco, Summary, BHD, Part IV of BHR upgrade - Removal of BSC eastern optics 
                   Reply  Fri Nov 5 12:21:16 2021, Anchal, Summary, BHD, Part VI of BHR upgrade - Removal of ITMYC optics XendFlowBenchLeftEnd.jpgXendFlowBenchMiddle.jpgXendFlowBenchRightEnd.jpg
                      Reply  Wed Dec 15 16:11:38 2021, Anchal, Summary, BHD, Part VIII of BHR upgrade - Placed LO1 signal-2021-12-15-161437.jpeg
                         Reply  Wed Dec 15 17:44:18 2021, Koji, Summary, BHD, Part VIII of BHR upgrade - Placed LO1 
                            Reply  Thu Jan 6 21:04:41 2022, Anchal, Summary, BHD, Part VIII of BHR upgrade - LO1 OSEMs inserted 
                               Reply  Mon Jan 10 14:52:51 2022, Anchal, Summary, BHD, LO1 OSEMs roughly calibrated and noise measured LO1_vs_ETMX_OSEM_Spectrum_LF_x30_Gain.pdfLO1_vs_ETMX_OSEM_Spectrum_HF_x30_Gain.pdf
                                  Reply  Mon Jan 10 18:36:41 2022, Anchal, Summary, BHD, LO1 free swinging test set to trigger 
                                     Reply  Tue Jan 11 12:19:12 2022, Anchal, Summary, BHD, LO1 Input Matrix Diagonalization performed. LO1_SUS_InpMat_Diagnolization.pdfLO1_FreeSwingData_PeakFitting.pdf
                               Reply  Mon Jan 24 18:53:09 2022, Anchal, Summary, BHD, Part VIII of BHR upgrade - LO2 placed and OSEMs tuned 
                                  Reply  Tue Jan 25 10:55:02 2022, Anchal, Summary, BHD, Part VIII of BHR upgrade - LO2 input matrix diagonalization performed. 
                                     Reply  Tue Jan 25 16:42:03 2022, Anchal, Summary, BHD, Reduced filter gains in all damped new SOS 
                         Reply  Thu Jan 6 11:54:20 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - Placed AS1 and AS4 
                            Reply  Fri Jan 7 16:17:42 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - Placed AS1 and AS4 filters 
                               Reply  Sat Jan 8 16:01:42 2022, Paco, Summary, BHD, Part IX of BHR upgrade - Placed LO2 filters 
                                  Reply  Tue Jan 18 14:26:09 2022, Paco, Summary, BHD, Part IX of BHR upgrade - Placed remaining filters SR2, PR3, PR2 
                               Reply  Tue Jan 11 18:18:29 2022, Anchal, Summary, BHD, Attempted OSEM installation on AS1 
                                  Reply  Tue Jan 11 18:40:25 2022, Anchal, Summary, BHD, AS1 Sat Amp has a PCB issue signal-2022-01-11-184917.jpeg
                                     Reply  Thu Jan 13 09:48:41 2022, Anchal, Summary, BHD, AS1 Sat Amp fixed signal-2022-01-13-094823_001.jpegsignal-2022-01-13-094823_002.jpeg
                                  Reply  Thu Jan 13 12:24:08 2022, Anchal, Summary, BHD, AS1 SD and LR magnets broke 
                                     Reply  Mon Jan 24 21:18:40 2022, Paco, Summary, BHD, Part IX of BHR upgrade - AS1 placed and OSEM tuned 
                                        Reply  Tue Jan 25 11:02:54 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - AS1 free swing test failed AS1_freeSwingTestFailed.pdf
                                           Reply  Thu Jan 27 08:27:34 2022, Paco, Summary, BHD, Part IX of BHR upgrade - AS1 inspection and correction 
                                              Reply  Wed Feb 2 16:32:02 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - AS1 free swing test still not good AS1_FreeSwingData_PeakFitting_20220125.pdfAS1_SUS_InpMat_Diagnolization_20220202.pdf
                                                 Reply  Tue Mar 15 18:42:37 2022, Anchal, Summary, BHD, Part IX of BHR upgrade - AS1 resuspended and OSEMs tuned 
                                                    Reply  Tue Mar 15 18:45:12 2022, Anchal, Summary, BHD, Part X of BHR upgrade - BHDBS Path setup 
                            Reply  Thu Jan 13 12:29:27 2022, Anchal, Summary, BHD, AS4 LR magnet broke 
                               Reply  Fri Jan 14 18:12:47 2022, Anchal, Summary, BHD, AS4 placed in ITMY Chamber, OSEMs connected 
                                  Reply  Tue Jan 18 18:19:22 2022, Koji, Summary, BHD, AS4 placed in ITMY Chamber, OSEMs connected Screen_Shot_2022-01-18_at_17.48.16.pngcable_swap.png
                                     Reply  Wed Jan 19 12:56:52 2022, Paco, Summary, BHD, AS4 OSEMs installation 
                                        Reply  Thu Jan 20 16:42:55 2022, Paco, Update, BHD, AS4 OSEMs installation - part 2 
                                           Reply  Thu Jan 20 18:16:29 2022, Anchal, Update, BHD, AS4 set to trigger free swing test 
                                              Reply  Fri Jan 21 16:40:10 2022, Anchal, Update, BHD, AS4 Input Matrix Diagonalization performed.  AS4_SUS_InpMat_Diagnolization_20220121.pdfAS4_FreeSwingData_PeakFitting_20220121.pdf
                                                 Reply  Mon Jan 24 17:12:27 2022, rana, Update, BHD, AS4 Input Matrix Diagonalization performed.  
                                                    Reply  Mon Jan 24 20:48:48 2022, Anchal, Update, BHD, AS4 Input Matrix Diagonalization performed.  
                   Reply  Tue Jan 18 15:19:49 2022, Paco, Summary, BHD, Part IV of BHR upgrade - Replaced old SR3 with SOS SR2. OSEM tuning attemtped. PXL_20220119_012954365.jpgPXL_20220119_013003522.jpg
                      Reply  Tue Jan 18 18:16:28 2022, Anchal, Summary, BHD, Part IV of BHR upgrade - SR2 Sat Amp Box inspection 
                         Reply  Wed Jan 19 12:50:10 2022, Anchal, Summary, BHD, Part IV of BHR upgrade - SR2 OSEM tuning progress. 
                            Reply  Thu Jan 20 17:03:36 2022, Anchal, Summary, BHD, Part IV of BHR upgrade - SR2 OSEM tuned. DJI_0144.JPG
                               Reply  Thu Jan 20 18:41:55 2022, Anchal, Summary, BHD, SR2 set to trigger free swing test 
                                  Reply  Fri Jan 21 11:24:42 2022, Anchal, Summary, BHD, SR2 Input Matrix Diagonalization performed.  SR2_SUS_InpMat_Diagnolization_20220121.pdfSR2_FreeSwingData_PeakFitting_20220121.pdf
                Reply  Thu Oct 28 17:01:54 2021, Anchal, Summary, BHD, Part III of BHR upgrade - Adding temp fixed flat mirror for PR2 
                Reply  Thu Jan 27 17:57:35 2022, Anchal, Summary, BHD, Part III of BHR upgrade - Replaced small suspended PR3 with new SOS PR3 and OSEM tuning 
                   Reply  Thu Jan 27 18:03:36 2022, Paco, Summary, BHD, Part III of BHR upgrade - Install PR2, balance, and attempt OSEM tuning 
                      Reply  Thu Jan 27 20:46:38 2022, Koji, Summary, BHD, Part III of BHR upgrade - Install PR2, balance, and attempt OSEM tuning Screen_Shot_2022-01-27_at_20.33.56.pngScreen_Shot_2022-01-27_at_21.30.16.png
                         Reply  Fri Jan 28 10:37:59 2022, Paco, Summary, BHD, Part III of BHR upgrade - PR2 OSEM finalized, reinsall LO1 OSEMs 
                            Reply  Fri Jan 28 11:30:52 2022, Koji, Summary, BHD, Part III of BHR upgrade - PR2 OSEM finalized, reinsall LO1 OSEMs 
                               Reply  Fri Jan 28 16:35:18 2022, Anchal, Summary, BHD, AS1, PR2 and PR3 set to trigger free swing test 
                            Reply  Wed Feb 2 16:22:00 2022, Anchal, Summary, BHD, Part III of BHR upgrade - PR2 inpute matrix diagonalized PR2_FreeSwingData_PeakFitting_20220125.pdfPR2_SUS_InpMat_Diagnolization_20220202.pdf
                   Reply  Wed Feb 2 16:27:57 2022, Anchal, Summary, BHD, Part III of BHR upgrade - PR3 inpute matrix diagonalized PR3_FreeSwingData_PeakFitting_20220125.pdfPR3_SUS_InpMat_Diagnolization_20220202.pdf
             Reply  Wed Oct 27 16:38:02 2021, Anchal, Summary, BHD, Part II of BHR upgrade - Relocation of TT2 and MMT1/2 alignment 
                Reply  Wed Oct 27 18:11:37 2021, Koji, Summary, BHD, Part II of BHR upgrade - Relocation of TT2 and MMT1/2 alignment 
                Reply  Wed Oct 27 18:16:45 2021, Koji, Summary, BHD, Part II of BHR upgrade - Relocation of TT2 and MMT1/2 alignment 
             Reply  Thu Mar 17 17:23:22 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment 
                Reply  Mon Mar 21 18:24:07 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment on Yarm 
                   Reply  Thu Mar 24 19:20:28 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment on Yarm 
                      Reply  Fri Mar 25 18:20:28 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment on Yarm 
                         Reply  Sat Mar 26 13:04:38 2022, Paco, Summary, BHD, Part IIa of BHR upgrade - Green laser alignment on Yarm 
                            Reply  Thu Mar 31 18:58:16 2022, Ian MacMillan, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Xarm 
                               Reply  Tue Apr 5 18:15:06 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Xarm 
                                  Reply  Wed Apr 6 01:20:48 2022, Koji, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Xarm PXL_20220406_060846581.jpgPXL_20220406_014205726.jpgPXL_20220406_060324812.jpgPXL_20220406_015259326.jpg
                                     Reply  Wed Apr 6 22:51:47 2022, Koji, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Xarm PXL_20220406_213356237.MP.jpgPXL_20220406_212936502.MP.jpg
                                  Reply  Wed Apr 6 12:03:51 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Yarm 
                                     Reply  Thu Apr 7 17:59:51 2022, Anchal, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Yarm 
                                        Reply  Fri Apr 8 17:21:31 2022, Ian MacMillan, Summary, BHD, Part IIa of BHR upgrade - IR laser alignment on Yarm 
                                           Reply  Mon Apr 11 21:13:21 2022, Paco, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging 
                                              Reply  Mon Apr 11 21:44:14 2022, Koji, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging D990543A1.PDFPXL_20220412_023941730.jpgPXL_20220412_023950567.jpg
                                                 Reply  Thu Apr 14 11:52:57 2022, yehonathan, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging Screenshot_2022-04-14_15-53-39.pngPXL_20220414_220616875.jpg
                                                    Reply  Thu Apr 14 18:39:13 2022, Paco, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging 
                                                       Reply  Mon Apr 18 17:53:45 2022, Paco, Summary, BHD, Part IIa of BHR upgrade - POY11 debugging 
Entry  Fri Apr 15 11:59:16 2022, Yehonathan, Update, IOO, IMC completely misaligned 
Entry  Thu Apr 14 09:04:30 2022, Jordan, Update, VAC, RGA Volume RGA Scans 40mRGA_Overlay.pdfRGAVolume_4_12_22.PNG
Entry  Wed Apr 13 15:57:25 2022, Ian MacMillan, Update, Cameras, Camera Battery Test 
    Reply  Wed Apr 13 18:55:54 2022, Koji, Update, Cameras, Camera Battery Test 
Entry  Wed Apr 13 16:23:54 2022, Ian MacMillan, Update, General, Smell in 40m 
Entry  Mon Apr 11 11:00:30 2022, Jancarlo, Update, VAC, C1VAC Reboot and Nitrogen tanks 
Entry  Thu Apr 7 20:41:15 2022, Tommy, Update, Electronics, RFSoC 2x2 Board -- Gain Plotter Screen_Shot_2022-04-07_at_8.40.23_PM.pngUnknown-3.pngUnknown-4.png
Entry  Thu Apr 7 20:37:06 2022, Tommy, Update, Electronics, RFSoC 2x2 Board -- Simple Tone Generator 
Entry  Wed Mar 9 11:52:18 2022, Yehonathan, Update, BHD, Simplified BHD readout sketch on ITMY table ITMY_Table_Sketch.drawio.pdf
    Reply  Wed Mar 9 12:57:52 2022, Koji, Update, BHD, Simplified BHD readout sketch on ITMY table 
    Reply  Fri Apr 1 14:26:50 2022, Tega, Update, Optical Levers, Simplified sketch on MC table MC_Table.drawio.pdf
       Reply  Fri Apr 1 17:02:02 2022, Koji, Update, Optical Levers, Simplified sketch on MC table 
          Reply  Fri Apr 1 22:22:29 2022, Koji, Update, Optical Levers, Simplified sketch on MC table 
             Reply  Mon Apr 4 15:49:06 2022, Tega, Update, Optical Levers, Simplified sketch on BS table BS_Table.drawio.pdf
Entry  Wed Oct 20 11:16:21 2021, Anchal, Summary, PEM, Particle counter setup near BS Chamber PXL_20211020_183728734.jpg
    Reply  Thu Oct 21 11:41:31 2021, Anchal, Summary, PEM, Particle counter setup near BS Chamber ParticleCountData20211021.pdf
       Reply  Thu Oct 21 15:22:35 2021, rana, Summary, PEM, Particle counter setup near BS Chamber 
    Reply  Thu Oct 21 15:24:35 2021, rana, Summary, PEM, Particle counter setup near BS Chamber 
       Reply  Fri Oct 22 17:35:08 2021, Ian MacMillan, Summary, PEM, Particle counter setup near BS Chamber 
          Reply  Fri Apr 1 14:26:19 2022, Ian MacMillan, Summary, PEM, Particle counter setup near BS Chamber IMG_1407.jpg
             Reply  Sat Apr 2 15:46:13 2022, rana, Summary, PEM, Particle counter setup near BS Chamber 
Entry  Tue Mar 29 17:35:54 2022, Paco, Update, SUS, Damping fix on BS, AS4, PR2, and PR3 
Entry  Tue Mar 29 15:07:11 2022, Tega, Summary, VAC, Opening of MC and ETM chambers 
Entry  Tue Feb 22 18:47:51 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement ALL_TF_Graph.pdf20220222_SUSElectronicsReplacement.7z
    Reply  Fri Feb 25 14:00:08 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement IMG_0853.jpgIMG_0852.jpg
       Reply  Fri Feb 25 14:48:53 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement Before.jpgAfter.jpg
          Reply  Sat Feb 26 23:48:14 2022, Koji, Update, SUS, ETMY SUS Electronics Replacement PXL_20220226_023111179_2.jpg
             Reply  Mon Feb 28 15:51:07 2022, Ian MacMillan, Update, SUS, ETMY 1Y4 Electronics Replacement IMG_0865.jpgIMG_0867.jpgIMG_0868.jpgIMG_0866.jpg
                Reply  Thu Mar 3 04:11:36 2022, Koji, Update, SUS, ETMY 1Y4 Electronics Replacement PXL_20220303_082726693.jpgPXL_20220303_082752494.jpgPXL_20220303_082744464.jpg
                   Reply  Thu Mar 3 04:24:23 2022, Koji, Update, SUS, ETMY 1Y4 Electronics Replacement PXL_20220303_094421604.jpgPXL_20220303_094435127.jpg
                      Reply  Thu Mar 3 17:21:11 2022, Ian MacMillan, Update, SUS, ETMY 1Y4 Electronics Replacement 
                         Reply  Sat Mar 5 02:03:46 2022, Koji, Update, SUS, ETMY 1Y4 Electronics Replacement 6x
                            Reply  Mon Mar 21 14:22:52 2022, Anchal, Update, SUS, ETMY Alignmnet offsets needed to be changed 
       Reply  Tue Mar 1 19:26:24 2022, Koji, Update, SUS, ETMY SUS Electronics Replacement PXL_20220302_025723651.jpgPXL_20220302_030102033.MP.jpg
    Reply  Mon Mar 7 16:44:15 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement 6x
       Reply  Fri Mar 11 16:43:03 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement 
          Reply  Fri Mar 25 11:39:14 2022, Anchal, Update, SUS, ETMY SUS Electronics Replacement - Questions 
             Reply  Mon Mar 28 16:25:34 2022, Ian MacMillan, Update, SUS, ETMY SUS Electronics Replacement - Questions 
    Reply  Thu Mar 17 11:40:41 2022, Paco, Update, SUS, ETMY green PZT HV supply 
Entry  Thu Mar 17 16:50:53 2022, Paco, Update, BHD, XARM AUX alignment 
    Reply  Fri Mar 18 17:15:19 2022, Paco, Update, BHD, XARM AUX alignment cont. Screen_Shot_2022-03-18_at_4.09.38_PM.png
       Reply  Mon Mar 21 18:00:05 2022, Ian MacMillan, Update, BHD, XARM AUX alignment cont. PXL_20220322_015247138.jpg
Entry  Tue Mar 15 13:49:44 2022, Ian MacMillan, Bureaucracy, Treasure, New Screwdriver Bits 
Entry  Tue Mar 15 10:45:31 2022, Paco, Update, General, Assembled small in-vac optics 
Entry  Thu Mar 10 10:05:49 2022, Paco, Update, SUS, AS1 free swing test SUS_Input_Matrix_Diagonalization.pdf
Entry  Thu Mar 10 09:39:59 2022, Jordan, Update, VAC, Leak Testing of New Manual Gate Valve - Attempt #2 3-09-2022.PNG3-10-2022.PNG
Entry  Wed Mar 9 10:23:28 2022, Jordan, Update, VAC, Leak Testing of New Manual Gate Valve - Attempt #1 
Entry  Tue Feb 2 17:09:17 2021, yehonathan, Update, BHD, SOS assembly 20210202_165501.jpg20210202_162452.jpg
    Reply  Tue Feb 2 18:24:54 2021, Koji, Update, BHD, SOS assembly 
       Reply  Thu Feb 4 15:14:55 2021, Yehonathan, Update, BHD, SOS assembly 20210204_144007.jpg
          Reply  Tue Feb 16 13:13:39 2021, Yehonathan, Update, BHD, SOS assembly 
             Reply  Tue Feb 16 15:29:01 2021, Koji, Update, BHD, SOS assembly 
                Reply  Tue Feb 16 22:59:36 2021, Yehonathan, Update, BHD, SOS assembly 
                   Reply  Fri Feb 19 12:21:04 2021, Yehonathan, Update, BHD, SOS assembly 
                      Reply  Fri Mar 26 10:25:37 2021, Yehonathan, Update, BHD, SOS assembly 
                         Reply  Tue Apr 6 15:42:57 2021, Yehonathan, Update, BHD, SOS assembly 20210406_150724.png
                            Reply  Fri Apr 9 20:54:54 2021, Yehonathan, Update, BHD, SOS assembly 20210409_202717.jpg20210409_202755.jpg
                               Reply  Mon Apr 12 17:30:11 2021, Yehonathan, Update, BHD, SOS assembly 20210412_170913.jpg
                                  Reply  Mon May 3 16:49:04 2021, Yehonathan, Update, BHD, SOS assembly 20210503_161422.png20210503_161456.jpg
                                     Reply  Tue Jun 1 16:17:06 2021, Yehonathan, Update, BHD, SOS assembly 
                                        Reply  Wed Jun 2 01:03:19 2021, Koji, Update, BHD, SOS assembly 
                                           Reply  Fri Jun 18 19:02:00 2021, Yehonathan, Update, BHD, SOS assembly 20210618_115017.jpgUntitled_2.png20210618_160041_HDR.jpg
                                              Reply  Fri Jun 18 23:53:08 2021, Koji, Update, BHD, SOS assembly 
                                                 Reply  Tue Jun 22 17:05:26 2021, Yehonathan, Update, BHD, SOS assembly 
                                                    Reply  Tue Jul 27 17:14:18 2021, Yehonathan, Update, BHD, SOS assembly 20210727_154506.png
                                                       Reply  Tue Jul 27 20:12:53 2021, Koji, Update, BHD, SOS assembly 
                                              Reply  Mon Jun 28 12:35:19 2021, Yehonathan, Update, BHD, SOS assembly toomuchglue1.pngtoomuchglue2.pngdirtydumbell.pngcleandumbell.pngassembly_on_metalbracket.png
                                                 Reply  Tue Jun 29 20:45:52 2021, Yehonathan, Update, BHD, SOS assembly 20210629_135736.jpg20210629_135746.jpg
                                                    Reply  Thu Jul 1 16:45:25 2021, Yehonathan, Update, BHD, SOS assembly 
                                                       Reply  Wed Jul 28 12:00:35 2021, Yehonathan, Update, BHD, SOS assembly 
                                                          Reply  Thu Sep 23 18:18:07 2021, Yehonathan, Update, BHD, SOS assembly dumbell_before.pngdumbell_after.png
                                                             Reply  Tue Oct 26 10:17:14 2021, Yehonathan, Update, BHD, SOS assembly 
                                                                Reply  Thu Oct 28 23:13:19 2021, Yehonathan, Update, BHD, SOS assembly OpLev_Setup.jpgsuspended_optic.png20211029_113011.jpg20211029_113052.jpg
                                                                   Reply  Tue Nov 2 15:02:03 2021, Yehonathan, Update, BHD, SOS assembly FreeSwingingSpectra.pdf
                                                                      Reply  Tue Nov 2 22:50:30 2021, Koji, Update, BHD, SOS assembly 
                                                                         Reply  Mon Nov 8 17:22:27 2021, Yehonathan, Update, BHD, SOS assembly Magnets_Positions.pngAdapters_Order.png
                                                                            Reply  Tue Nov 9 11:11:37 2021, Yehonathan, Update, BHD, SOS assembly 20211109_110408.jpg
                                                                               Reply  Fri Nov 12 23:47:29 2021, Yehonathan, Update, BHD, SOS assembly 
                                                                                  Reply  Tue Nov 16 17:42:46 2021, Yehonathan, Update, BHD, SOS assembly 20211115_170320_HDR.jpg20211116_163846.jpgmagnet_height_check(1).pngside_blcok_touching_1.pngside_blcok_touching_2.png
                                                                                     Reply  Tue Nov 16 18:28:53 2021, Koji, Update, BHD, SOS assembly D2100546_Wire_Block.pdfD2100546_Wire_Block.png
                                                                                        Reply  Wed Nov 24 14:15:15 2021, Yehonathan, Update, BHD, SOS assembly 
                                                                                           Reply  Wed Dec 1 12:57:08 2021, Yehonathan, Update, BHD, SOS assembly 7x
                                                                                              Reply  Mon Dec 6 18:23:04 2021, Yehonathan, Update, BHD, SOS assembly signal-2021-12-06-165751_001.jpeg
                                                                                                 Reply  Thu Dec 9 21:57:35 2021, Yehonathan, Update, BHD, SOS assembly balancingsos2.pngFreeSwingingSpectra.pdf
                                                                                                    Reply  Tue Dec 14 14:02:33 2021, Yehonathan, Update, BHD, SOS assembly magnetcentring.pngFreeSwingingSpectra.pdf
                                                                                                       Reply  Wed Dec 15 22:09:53 2021, Yehonathan, Update, BHD, SOS assembly 
                                                                                                          Reply  Thu Dec 16 18:16:36 2021, Yehonathan, Update, BHD, SOS assembly chippedmirror.pngIMG_6311.JPGIMG_6310.JPGIMG_6309.JPG
                                                                                                             Reply  Fri Dec 17 17:50:17 2021, Yehonathan, Update, BHD, SOS assembly AS1rollbalance.pngAS1Magnet_height.pngghostbeam.pnglambdaopticarrow.jpg
                                                                                                                Reply  Fri Dec 17 19:16:45 2021, Koji, Update, BHD, SOS assembly 
                                                                                                                   Reply  Fri Dec 17 22:16:07 2021, Yehonathan, Update, BHD, SOS assembly 
                                                                                                                      Reply  Sat Dec 18 00:56:14 2021, Koji, Update, BHD, SOS assembly 
                                                                                                                         Reply  Mon Dec 20 13:52:01 2021, Koji, Update, BHD, SOS assembly 
                                                                                                                            Reply  Mon Dec 20 17:26:13 2021, Yehonathan, Update, BHD, SOS assembly 7x
                                                                                                                               Reply  Tue Dec 21 18:04:46 2021, Yehonathan, Update, BHD, SOS assembly 
                                                                                                                                  Reply  Tue Jan 4 18:27:23 2022, Paco, Update, BHD, SOS assembly -- PR3 PR3_roll_balance.pngPR3_magnet_height.pngFreeSwingingSpectra.pdfPXL_20220104_231742123.jpgPXL_20220104_232809203.jpg
                                                                                                                                     Reply  Wed Jan 5 19:18:06 2022, Yehonathan, Update, BHD, SOS assembly -- AS4 AS4_roll_balance.pngAS_4_magnet_height.pngFreeSwingingSpectra.pdf
                                                                                                                                        Reply  Thu Jan 6 17:00:20 2022, Yehonathan, Update, BHD, SOS assembly -- LO2 LO2_roll_balance.pngLO2_magnet_height.pngFreeSwingingSpectra.pdf
                                                                                                                                           Reply  Thu Jan 6 17:16:51 2022, Yehonathan, Update, BHD, Using Peek screws/nuts 
                                                                                                                                           Reply  Fri Jan 7 17:59:45 2022, Yehonathan, Update, BHD, SOS assembly -- SR2 SR2_roll_balance.pngSR2_magnet_height.pngFreeSwingingSpectra.pdf
                                                                                                                                              Reply  Fri Jan 7 18:24:25 2022, Koji, Update, BHD, SOS assembly -- SR2 
                                                                                                                                                 Reply  Mon Jan 10 14:00:44 2022, not Koji, Update, BHD, SOS assembly -- SR2 
                                                                                                                                                    Reply  Tue Jan 11 09:53:14 2022, not Koji, Update, BHD, SOS assembly -- Peek screws and nuts 
                                                                                                                                                       Reply  Thu Jan 13 16:08:00 2022, Yehonathan, Update, BHD, gluing magnets after AS1/4 misfortune 
                                                                                                                                                          Reply  Fri Jan 14 17:33:10 2022, Yehonathan, Update, BHD, AS4 resurrection AS4_roll_balance2.pngAS4_magnet_height2.pngFreeSwingingSpectra.pdf
                                                                                                                                                             Reply  Wed Jan 19 18:15:34 2022, Yehonathan, Update, BHD, AS1 resurrection AS1_roll_balance2.pngAS1_magnet_heigh2.pngFreeSwingingSpectra.pdfIMG_6324.JPG
                                                                                                                                                                Reply  Thu Jan 20 12:10:51 2022, Yehonathan, Update, BHD, AS1 resurrection FreeSwingingSpectra.pdfFreeSwingingSpectra_div_20mV.pdfFreeSwingingSpectra_div_50mV.pdf
                                                                                                                                                                   Reply  Mon Jan 24 17:58:21 2022, Yehonathan, Update, BHD, PR2 Suspension 
                                                                                                                                                                      Reply  Tue Jan 25 18:37:12 2022, TYehonathan, Update, BHD, PR2 Suspension PR2_magnet_height.pngPR2_roll_balance.pngFreeSwingingSpectra_div_50mV.pdf
                                                                                                                                                                         Reply  Thu Feb 24 18:05:58 2022, Yehonathan, Update, BHD, Re-susspension of AS1 signal-2022-02-24-173933_003.jpegsignal-2022-02-24-173933_002.jpeg
                                                                                                                                                                            Reply  Wed Mar 2 14:02:43 2022, Yehonathan, Update, BHD, Re-susspension of AS1 
                                                                                                                                                                               Reply  Thu Mar 3 17:09:46 2022, Paco, Update, BHD, Re-susspension of AS1 
                                                                                                                                                                                  Reply  Mon Mar 7 16:56:08 2022, Yehonathan, Update, BHD, Re-susspension of AS1 signal-2022-03-07-171520_001.pngsignal-2022-03-07-172659_001.jpegsignal-2022-03-07-172659_003.jpeg
                                                                                                                                                                                     Reply  Mon Mar 7 18:53:16 2022, Koji, Update, BHD, Re-susspension of AS1 
                                                                                                                                                                                     Reply  Tue Mar 8 12:24:13 2022, Yehonathan, Update, BHD, Re-susspension of AS1 AS1_Roll_Balance.pngAS1_Height_Balance.pngFreeSwingingSpectra_new.pdf
                                                                                                                                                                                        Reply  Tue Mar 8 19:29:36 2022, Paco, Update, BHD, Re-balance of AS1 
                                                                                                                                                                                           Reply  Wed Mar 9 09:35:26 2022, Paco, Update, BHD, Re-balance of AS1 
Entry  Sat Feb 26 01:01:40 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels 
    Reply  Sat Feb 26 15:45:14 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels Vac-gauges-flow-diagram.png
       Reply  Mon Feb 28 19:15:10 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels 
       Reply  Tue Mar 1 20:38:49 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels Working_Serial_Port_List_1.pngWorking_Serial_Port_List_2.pngWorking_Config_Ports#1-5.pngWorking_Config_Ports#7-8.png
          Reply  Wed Mar 2 11:50:39 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels XGS600_IOLAN_settings_1.pngXGS600_IOLAN_settings_2.pngXGS600_USBserial_settings.pngXGS600_comm_test.pyXGS600_comm_test_result.txt
             Reply  Wed Mar 2 12:40:08 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels 6x
                Reply  Sun Mar 6 18:14:45 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels iolan_xgs_comm_investigation.pdf
                   Reply  Mon Mar 7 13:53:40 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels iolan_xgs_comm_live.pdf
                      Reply  Mon Mar 7 14:52:34 2022, Koji, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels 
                         Reply  Tue Mar 8 12:08:47 2022, Tega, Update, VAC, Ongoing work to get the FRG gauges readouts to EPICs channels XGS600_calibration.pdf
Entry  Mon Mar 7 10:06:32 2022, Yehonathan, Update, IOO, IMC unlocked again, completely misaligned Screenshot_2022-03-07_10-15-19.png
    Reply  Mon Mar 7 14:55:33 2022, Koji, Update, IOO, IMC unlocked again, completely misaligned 
Entry  Sat Mar 5 01:58:49 2022, Koji, Summary, CDS, paola rescue PXL_20220305_035255834.jpgPXL_20220305_034649120.MP.jpg
Entry  Fri Mar 4 18:12:44 2022, Koji, Update, VAC, RGA pumping down Screenshot_2022-03-04_19-38-11.png
Entry  Mon Feb 7 09:00:26 2022, Paco, Update, General, Scheduled power outage recovery 
    Reply  Mon Feb 7 15:32:48 2022, Yehonathan, Update, General, Y End laser controller 
    Reply  Mon Feb 7 16:53:02 2022, Koji, Update, General, Scheduled power outage recovery PXL_20220208_001646282.jpgPXL_20220208_001657871.jpg
       Reply  Wed Feb 9 11:56:24 2022, Anchal, Update, General, Bringing back CDS Screenshot_2022-02-09_12-11-33.png
          Reply  Wed Feb 9 13:55:05 2022, Koji, Update, General, Bringing back CDS 
       Reply  Wed Feb 9 16:43:35 2022, Paco, Update, General, Scheduled power outage recovery - Locking mode cleaner(s) 
          Reply  Thu Feb 10 15:41:00 2022, Anchal, Update, General, Scheduled power outage recovery - Locking mode cleaner(s) 
             Reply  Thu Feb 10 17:57:48 2022, Anchal, Update, General, Scheduled power outage recovery - Locking mode cleaner(s) PXL_20220211_021509819.jpg
                Reply  Thu Feb 10 19:03:23 2022, Koji, Update, General, Scheduled power outage recovery - Locking mode cleaner(s) 
                   Reply  Thu Feb 10 19:46:37 2022, Koji, Update, General, Scheduled power outage recovery - Locking mode cleaner(s) 
                      Reply  Thu Feb 10 21:10:43 2022, Koji, Update, General, Video Mux setting reset Screenshot_2022-02-10_21-11-21.pngScreenshot_2022-02-10_21-11-54.png
             Reply  Fri Feb 11 16:09:11 2022, Anchal, Update, General, Scheduled power outage recovery - Input power increased 
                Reply  Mon Feb 14 18:31:50 2022, Paco, Update, General, Scheduled power outage recovery - IMC recovery progress 
                   Reply  Tue Feb 15 19:32:50 2022, Koji, Update, General, Scheduled power outage recovery - IMC recovery progress PXL_20220216_001731377.jpgScreen_Shot_2022-02-15_at_16.18.16.pngPXL_20220216_001727465.jpgScreen_Shot_2022-02-15_at_16.22.16.pngPXL_20220216_002229572.jpg
                      Reply  Tue Feb 15 19:40:02 2022, Koji, Update, General, IMC locking 
                         Reply  Wed Feb 16 15:19:41 2022, Anchal, Update, General, Reconfigured MC reflection path for low power 
                            Reply  Wed Feb 23 15:08:57 2022, Anchal, Update, General, Removed extra beamsplitter in MC WFS path 
                               Reply  Thu Feb 24 14:32:57 2022, Anchal, Update, General, MC RFPD DCMON channel got stuck to 0 
                                  Reply  Thu Feb 24 19:26:32 2022, Anchal, Update, General, IMC Locking 
                                     Reply  Sun Feb 27 00:37:00 2022, Koji, Update, General, IMC Locking Recovery PXL_20220226_093809056.jpgPXL_20220226_093854857.jpgPXL_20220226_100859871.jpgScreenshot_2022-02-26_01-56-31.pngScreenshot_2022-02-26_01-56-47.png
                                        Reply  Sun Feb 27 01:12:46 2022, Koji, Update, General, IMC manual alignment procedure PXL_20220226_100859871.jpg
    Reply  Fri Feb 11 11:17:00 2022, Anchal, Update, General, Scheduled power outage recovery 
       Reply  Mon Feb 14 21:03:25 2022, Koji, Update, General, Scheduled power outage recovery PXL_20220215_025325118.jpg
Entry  Mon Feb 14 18:43:49 2022, Paco, Summary, General, SOS materials clean room cleared 
Entry  Thu Feb 10 21:51:02 2022, Koji, Update, CDS, [Solved] Huge random numbers flowing into ETMX/ETMY ASC PIT/YAW Screenshot_2022-02-10_21-46-02.pngScreen_Shot_2022-02-10_at_21.54.21.pngScreen_Shot_2022-02-10_at_22.14.23.png
    Reply  Fri Feb 11 10:56:38 2022, Anchal, Update, CDS, [Solved] Huge random numbers flowing into ETMX/ETMY ASC PIT/YAW 
       Reply  Fri Feb 11 12:22:19 2022, rana, Update, CDS, [Solved] Huge random numbers flowing into ETMX/ETMY ASC PIT/YAW 
          Reply  Fri Feb 11 17:07:19 2022, Anchal, Update, CDS, [Solved] Huge random numbers flowing into ETMX/ETMY ASC PIT/YAW 
Entry  Thu Feb 10 21:16:27 2022, Koji, Summary, CDS, chiara resolv.conf wierdo 
Entry  Thu Feb 10 14:39:31 2022, Koji, Summary, Computers, Network security issue resolved PXL_20220210_220816955.jpgPXL_20220210_220827167.jpg
Entry  Tue Nov 9 13:40:02 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics 
    Reply  Tue Nov 9 16:55:52 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics IMG_8107.JPG
       Reply  Tue Nov 9 18:05:03 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics 
          Reply  Mon Nov 15 15:12:28 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics 
             Reply  Tue Nov 16 17:29:49 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics x_x_TF1.pdf
                Reply  Thu Nov 18 20:00:43 2021, Ian MacMillan, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics Final_Plant_Testing.zip
                   Reply  Mon Nov 22 16:38:26 2021, Tega, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics 
                      Reply  Mon Jan 24 17:10:25 2022, Tega, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics Screen_Shot_2022-01-24_at_5.33.15_PM.png
                         Reply  Thu Jan 27 16:40:57 2022, Tega, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics simplant_control_1.pngsimplant_control_0.png
                            Reply  Thu Feb 3 17:15:23 2022, Tega, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics Screen_Shot_2022-02-03_at_8.23.07_PM.png
                               Reply  Wed Feb 9 14:34:27 2022, Ian, Summary, Computer Scripts / Programs, SUS Plant Plan for New Optics SummaryMdemScreen.png
Entry  Mon Feb 7 16:14:37 2022, Tega, Update, Computers, realtime system reboot problem 
Entry  Fri Feb 4 10:21:39 2022, Anchal, Summary, General, Complete lab shutdown Vac_Status_Screenshot_2022-02-04_10-19-24.png
Entry  Fri Feb 4 10:04:47 2022, Chub, Update, General, dish soap and clean scrub sponges! 40m_supplies.jpg
Entry  Thu Feb 3 14:47:12 2022, Chub, Update, Electronics, new UPS in place 
Entry  Thu Feb 3 10:25:59 2022, Jordan, Update, VAC, TP1 and Manual Gate Valve Install 20220203_101455.jpg20220203_094831.jpg20220203_094823.jpg
Entry  Thu Jan 20 17:34:07 2022, Koji, Update, BHD, V6-704/705 Mirror now @Downs PXL_20220120_225248265_2.jpgPXL_20220120_225309361_2.jpg
    Reply  Fri Jan 21 14:51:00 2022, Koji, Update, BHD, V6-704/705 Mirror now @Downs M1.PNGM1_30mm.PNGM2.PNGM2_30mm.PNG
       Reply  Tue Feb 1 20:16:09 2022, Tega, Update, BHD, PR2 candidate mirror analysis PR2_M2_data.pngPR2_M2_recon_FoV_10mm.pngPR2_M2_residual_FoV_10mm.png
Entry  Mon Jan 31 10:39:19 2022, Jordan, Update, VAC, TP1 and Manual Gate Valve Removal 20220131_100637.jpg20220131_102807.jpg20220131_102818.jpg20220131_100647.jpg
Entry  Mon Jan 24 12:33:41 2022, rana, Configuration, Wiki, AIC Wiki: txz files allowed 
Entry  Thu Jan 6 22:18:47 2022, Koji, Update, CDS, SUS screen debugging Screen_Shot_2022-01-06_at_18.03.24.png
    Reply  Tue Jan 11 10:46:07 2022, Tega, Update, CDS, SUS screen debugging 
       Reply  Fri Jan 21 12:46:31 2022, Tega, Update, CDS, SUS screen debugging Custom_ADC_DAC_monitors.png
Entry  Tue Jan 11 10:58:58 2022, Tega, Update, SUS, Temporary watchdog 
    Reply  Tue Jan 11 13:43:14 2022, Koji, Update, SUS, Temporary watchdog 
    Reply  Wed Jan 19 21:39:22 2022, Tega, Update, SUS, Temporary watchdog 
       Reply  Thu Jan 20 00:26:50 2022, Koji, Update, SUS, Temporary watchdog 
       Reply  Thu Jan 20 17:21:21 2022, Tega, Update, SUS, Temporary watchdog 
Entry  Tue Jan 4 18:26:59 2022, Anchal, Update, BHD, Tested 2" PR2 candidates transmission 
    Reply  Wed Jan 5 17:46:04 2022, Anchal, Update, BHD, Tested 2" PR2 candidates transmission 
       Reply  Mon Jan 10 18:20:45 2022, Anchal, Update, BHD, Tested 2" PR2 candidates transmission 
          Reply  Tue Jan 11 15:21:16 2022, Anchal, Update, BHD, PR2 transmission calculation LO_power_vs_PR2_transmission.pdfPRC_Gain_vs_PR2_transmission.pdfPRS_Trans_Calc.ipynb.zip
             Reply  Thu Jan 13 17:10:55 2022, Anchal, Update, BHD, PR2 transmission calculation LO_power_vs_PR2_transmission.pdfPRC_Gain_vs_PR2_transmission.pdfPR2_Trans_Calc.ipynb.zip
                Reply  Fri Jan 14 03:07:04 2022, Koji, Update, BHD, PR2 transmission calculation 
                   Reply  Fri Jan 14 11:00:29 2022, Anchal, Update, BHD, PR2 transmission calculation 
                      Reply  Fri Jan 14 13:46:25 2022, Anchal, Update, BHD, PR2 transmission calculation updated LO_power_vs_PR2_transmission.pdfPRC_Gain_vs_PR2_transmission.pdfPR2_Trans_Calc.ipynb.zip
                         Reply  Wed Jan 19 16:22:48 2022, Anchal, Update, BHD, PR2 transmission calculation updated PR2transmissionSelectionAnalysis.pdfPR2_Trans_Calc.ipynb.zip
                            Reply  Thu Jan 20 01:48:02 2022, Koji, Update, BHD, PR2 transmission calculation updated 
Entry  Wed Jan 19 14:41:23 2022, Koji, Update, BHD, Suspension Status 
Entry  Fri Jan 14 14:04:51 2022, Paco, Update, Electronics, RFSoC 2x2 board arrived PXL_20220114_211249499.jpg
Entry  Thu Dec 16 15:04:12 2021, Chub, Update, Electronics, ITMX feedthroughs and in-vac cables installed ITMX_feedthrough_install_12-16-21.jpg
    Reply  Thu Dec 16 15:54:08 2021, Koji, Update, Electronics, ITMX feedthroughs and in-vac cables installed PXL_20211216_235056582.jpg
    Reply  Mon Jan 10 15:45:55 2022, Paco, Update, Electronics, ITMY feedthroughs and in-vac cables installed - part I 
       Reply  Tue Jan 11 10:23:18 2022, Paco, Update, Electronics, ITMY feedthroughs and in-vac cables installed - part II 
          Reply  Tue Jan 11 14:21:53 2022, Paco, Update, Electronics, BS feedthroughs and in-vac cables installed 
             Reply  Fri Jan 14 12:01:21 2022, Anchal, Update, Electronics, BS & ITMY feedthroughs labeled and connected to Sat Amps 
Entry  Tue Dec 14 19:29:42 2021, Paco, Update, BHD, 1Y0 rack work for LO1 
    Reply  Mon Jan 3 12:05:08 2022, Paco, Update, BHD, 1Y0 rack work for LO2 AS1 AS4 
       Reply  Mon Jan 3 16:46:41 2022, Paco, Update, BHD, 1Y1 rack work for SR2, PR2, PR3 
          Reply  Fri Jan 7 17:54:13 2022, Anchal, Update, BHD, PR2 Sat Amp has a bad channel Screen_Shot_2022-01-07_at_6.05.39_PM.png
             Reply  Fri Jan 7 18:28:13 2022, Koji, Update, BHD, PR2 Sat Amp has a bad channel 
                Reply  Mon Jan 10 13:35:52 2022, Anchal, Update, BHD, PR2 Sat Amp has a bad channel 
                   Reply  Mon Jan 10 15:59:46 2022, Koji, Update, BHD, PR2 Sat Amp has a bad channel 6x
                      Reply  Mon Jan 10 17:04:47 2022, Anchal, Update, BHD, AS1 Sat Amp CH2 had offset 
Entry  Thu Jan 6 15:10:38 2022, Koji, Update, SUS, ITMX Chamber work PXL_20220107_044739280.MP.jpgPXL_20220107_044958224.jpgPXL_20220107_044805503.NIGHT.jpgScreen_Shot_2022-01-06_at_20.54.04.png
Entry  Thu Jan 6 14:08:14 2022, Koji, Update, CDS, More BHD SUS screens added to sitemap Screenshot_2022-01-06_14-06-15.png
Entry  Wed Jan 15 08:55:14 2020, gautam, Update, CDS, Yearly DAQD fix DCerrors_fixed.png
    Reply  Thu Jan 6 12:52:49 2022, Anchal, Update, CDS, Yearly DAQD fix 2022! 
       Reply  Thu Jan 6 13:54:28 2022, Koji, Update, CDS, Yearly DAQD fix 2022! Screenshot_2022-01-06_13-57-40.png
Entry  Sun Jan 2 20:46:46 2022, Koji, Update, SUS, End SUS Electronics building PXL_20220103_081133119.jpg
Entry  Wed Dec 22 14:57:05 2021, Koji, Update, General, chiara local backup 
    Reply  Thu Dec 23 16:38:21 2021, Koji, Update, General, Is megatron down? (Re: chiara local backup) 
       Reply  Fri Dec 24 16:49:41 2021, Koji, Update, General, Is megatron down? (Re: chiara local backup) PXL_20211224_235652821.jpg
Entry  Fri Dec 17 12:32:35 2021, Koji, Update, SUS, Remaining task for 2021 
    Reply  Fri Dec 17 19:19:42 2021, Koji, Update, SUS, Remaining task for 2021 PXL_20211218_030145356.MP.jpg
       Reply  Sun Dec 19 07:52:51 2021, Anchal, Update, SUS, Remaining task for 2021 
    Reply  Wed Dec 22 18:16:23 2021, Koji, Update, SUS, Remaining task for 2021 ITMX_2016_07_21.jpgScreen_Shot_2021-12-22_at_18.03.42.png
Entry  Tue Dec 21 16:52:39 2021, Anchal, Summary, Electronics, In-air Sat Amp to Vacuum Flange cables laid for 7 new SOS 
Entry  Tue Dec 21 16:35:39 2021, Koji, Update, VAC, ITMX NW feedthru (LO1-1) connector pin bent PXL_20211222_002019620.jpgPXL_20211222_003014068.jpg
Entry  Fri Dec 10 15:59:23 2021, Paco, Update, BHD, Finished Coil driver (even serial number) units tests dc_fail.jpg
    Reply  Thu Dec 16 12:21:16 2021, Anchal, Update, BHD, Coil driver test failed for S2100619-v1 D1100687_S2100619-v1_TF_CH2_Not_Matching.pdf
       Reply  Thu Dec 16 17:41:12 2021, Koji, Update, BHD, Coil driver test failed for S2100619-v1 6x
    Reply  Thu Dec 16 15:32:59 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests 
       Reply  Thu Dec 16 17:57:17 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests 
       Reply  Mon Dec 20 14:10:56 2021, Anchal, Update, BHD, All coil drivers ready to be used, modified and tested 
Entry  Wed Dec 15 15:06:08 2021, Jordan, Update, VAC, Vacuum Feedthru Install 
Entry  Wed Dec 15 13:57:59 2021, Paco, Update, Computers, upgraded ubuntu on zita 
Entry  Mon Dec 13 15:05:47 2021, Tega, Update, PEM, git repo for temp sensor and sus medm 
    Reply  Tue Dec 14 11:33:29 2021, Tega, Update, PEM, git repo for temp sensor and sus medm 
Entry  Fri Dec 10 21:35:15 2021, Koji, Summary, SUS, Vertex SUS DAC adapter ready PXL_20211211_053155009.jpgPXL_20211211_053209216.jpgPXL_20211211_050625141-1.jpg
Entry  Mon Dec 6 14:26:52 2021, Koji, Update, VAC, Pumping down the RGA section 
    Reply  Tue Dec 7 13:12:50 2021, Koji, Update, VAC, Pumping down the RGA section 
       Reply  Wed Dec 8 10:14:43 2021, Jordan, Update, VAC, Pumping down the RGA section 40m_RGAVolume_12_8_21.PNG40m_RGAVolume_Torr_12_8_21.PNG
          Reply  Fri Dec 10 19:22:01 2021, Koji, Update, VAC, Pumping down the RGA section 
Entry  Thu Dec 9 00:32:56 2021, Tega, Update, CDS, New SUS medm screen update Screen_Shot_2021-12-09_at_12.29.30_AM.pngScreen_Shot_2021-12-09_at_12.42.35_AM.png
    Reply  Thu Dec 9 18:22:36 2021, Tega, Update, CDS, New SUS medm screen update Screen_Shot_2021-12-09_at_6.21.09_PM.png
       Reply  Fri Dec 10 18:55:58 2021, Tega, Update, CDS, New SUS medm screen update BLRMS_ITMY_screenshot.png
Entry  Mon Aug 23 11:51:26 2021, Koji, Update, General, Campus Wide Power Glitch Reported: Monday, 8/23/21 at 9:30am  
    Reply  Mon Aug 23 19:00:05 2021, Koji, Update, General, Campus Wide Power Glitch Reported: Monday, 8/23/21 at 9:30am  
       Reply  Mon Aug 23 22:51:44 2021, Anchal, Update, General, Time synchronization efforts 
          Reply  Tue Aug 24 09:22:48 2021, Anchal, Update, General, Time synchronization working now 
             Reply  Tue Aug 24 18:11:27 2021, Paco, Update, General, Time synchronization not really working 
                Reply  Tue Aug 24 22:37:40 2021, Anchal, Update, General, Time synchronization not really working 
    Reply  Wed Nov 17 17:37:53 2021, Anchal, Update, General, Placed Nodus and fb1 on UPS power 
       Reply  Thu Nov 18 15:16:10 2021, Anchal, Update, General, Moved Chiara to 1X7 above nodus powered with same UPS 
          Reply  Mon Nov 22 17:42:19 2021, Anchal, Update, General, Connected Megatron to battery backed ports of another UPS 
             Reply  Tue Nov 30 17:11:06 2021, Paco, Update, General, Moved white rack to 1X3.5 IMG_8749.JPGIMG_8750.JPG
Entry  Wed Nov 24 17:13:31 2021, Yehonathan, Metaphysics, General, Toilet tank broken 
    Reply  Tue Nov 30 11:03:44 2021, Yehonathan, Metaphysics, General, Toilet tank broken 
Entry  Mon Nov 29 15:24:53 2021, Hang, HowTo, General, Fisher matrix vs length of each FFT segment setup.pdfFisher_vs_Tperseg.pdffisher_vs_mcmc_offset_removed.pngfisher_vs_mcmc.png
Entry  Wed Nov 24 14:34:15 2021, Yehonathan, Update, BHD, Saving on SUSAUX slow channels 
Entry  Tue Nov 23 18:02:05 2021, Anchal, Update, IMC, MC autolocker shifted to python3 script running in docker 
Entry  Thu Nov 18 14:29:01 2021, Koji, Summary, BHD, BHD invac optics / opto-mechanics 
Entry  Wed Nov 17 07:32:48 2021, Chub, Update, General, wire clamp plate mod 
    Reply  Wed Nov 17 11:53:27 2021, Koji, Update, General, wire clamp plate mod 
Entry  Tue Nov 16 11:37:26 2021, Hang, HowTo, SUS, Fitting suspension model--large systematic errors L2L_L3P_fit.pdfL2L_L3P_residual.pdf
Entry  Thu Nov 11 00:11:39 2021, Koji, Summary, SUS, 2" to 3" sleeve issue 6x
Entry  Fri Oct 29 14:39:37 2021, Anchal, Summary, BHD, 1Y1 cleared. IY3 ready for C1SUS2 I/O and FE. RemovedStuff.jpeg1Y1.jpeg1Y3.jpeg
    Reply  Tue Nov 2 16:42:00 2021, Paco, Summary, BHD, 1Y1 rack work 
       Reply  Tue Nov 2 18:54:41 2021, Anchal, Paco, Update, BHD, Optical fibres laid for BHD upgrade 
       Reply  Thu Nov 4 15:03:43 2021, Koji, Summary, BHD, 1Y1 rack work 
          Reply  Mon Nov 8 10:13:52 2021, Paco, Summary, BHD, 1Y1 rack work; Sorensens removed 
             Reply  Mon Nov 8 13:13:00 2021, Koji, Summary, BHD, 1Y1 rack work; Sorensens removed 40m_BHD.png
                Reply  Mon Nov 8 15:29:05 2021, Paco, Summary, BHD, 1Y1 rack work; New power for cameras 
                   Reply  Mon Nov 8 18:42:38 2021, Koji, Summary, BHD, Rack Layout / Power Strips rack_plan.pdf
                      Reply  Tue Nov 9 19:02:47 2021, Anchal, Summary, BHD, 1Y0 Populated and 1Y1,1Y0 powered 
Entry  Thu Nov 4 18:29:51 2021, Tega, Update, SUS, Setting up suspension test model 
    Reply  Fri Nov 5 12:49:32 2021, rana, Update, SUS, Setting up suspension test model 
       Reply  Mon Nov 8 17:52:22 2021, Ian MacMillan, Update, SUS, Setting up suspension test model x1sus_cp.png
Entry  Fri Nov 5 20:35:10 2021, Koji, Update, BHD, Feedthru / Optical Mounts P_20211105_200817.jpg
Entry  Wed Nov 3 16:55:23 2021, Ian MacMillan, Summary, SUS, SUS Plant Plan for New Optics 
Entry  Mon Nov 1 14:51:34 2021, Koji, Update, General, Checking the vent plan 
Entry  Sun Oct 31 14:21:31 2021, rana, HowTo, Treasure, IFOCad 
Entry  Wed Oct 27 19:34:52 2021, Koji, Summary, Electronics, New electronics racks P_20211027_180737.jpgP_20211027_180443.jpgP_20211027_180408.jpgP_20211027_180139.jpg
Entry  Tue Oct 26 14:53:24 2021, Koji, Update, Electronics, Rack P_20211026_143814.jpg
Entry  Tue Oct 26 13:27:07 2021, Tega, Summary, Electronics, Sat Amp modification Summary SapAmpModStack.jpgSatAmpInstalled.jpg
Entry  Thu Oct 21 11:38:43 2021, Jordan, Update, SUS, Standoffs for Side Magnet on 3" Adapter Ring SOS Assembly Magnet_Standoffs.jpg
Entry  Mon Oct 18 10:02:17 2021, Koji, Update, VAC, Vent Started / Completed Screen_Shot_2021-10-18_at_14.52.34.pngScreenshot_2021-10-18_15-08-59.png
    Reply  Tue Oct 19 10:59:09 2021, Koji, Update, VAC, Vent Started / Completed 
       Reply  Tue Oct 19 11:30:39 2021, Koji, Update, VAC, How to vent TP1 Screen_Shot_2021-10-18_at_14.52.34.png
          Reply  Wed Oct 20 15:58:27 2021, Koji, Update, VAC, How to vent TP1 
Entry  Mon Oct 18 16:48:32 2021, Tega, Update, Electronics, Sat Amp modifications IMG_20211018_162918574.jpg
Entry  Fri Oct 15 16:46:27 2021, Anchal, Summary, Optical Levers, Vent Prep Screen_Shot_2021-10-15_at_4.34.45_PM.pngScreen_Shot_2021-10-15_at_4.45.31_PM.pngScreen_Shot_2021-10-15_at_4.34.45_PM.pngScreen_Shot_2021-10-15_at_4.34.45_PM.png
    Reply  Fri Oct 15 17:17:51 2021, Koji, Summary, General, Vent Prep 7x
       Reply  Fri Oct 15 20:53:49 2021, Koji, Summary, General, Vent Prep 
Entry  Thu Oct 14 16:38:26 2021, Ian MacMillan, Update, General, Kicking optics in freeSwing measurment 
    Reply  Fri Oct 15 12:14:27 2021, Ian MacMillan, Update, General, Kicking optics in freeSwing measurment 20211015_Kicktest_plot.pdf
Entry  Thu Oct 14 20:16:22 2021, Yehonathan, Update, General, PRMI free swinging 
Entry  Thu Oct 14 18:30:23 2021, Koji, Summary, VAC, Flange/Cable Stand Configuration 40m_flange_layout_20211014.pdf
Entry  Mon Sep 20 12:20:31 2021, Paco, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements PRM_PIT_ACT_TF.pdfPRM_YAW_ACT_TF.pdfBS_PIT_ACT_TF.pdfBS_YAW_ACT_TF.pdf
    Reply  Mon Sep 20 14:22:00 2021, rana, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements 
       Reply  Thu Sep 23 15:29:11 2021, Paco, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements BS_PRM_ANG_ACT_TF.pdf
          Reply  Fri Oct 1 14:25:27 2021, yehonathan, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements MICH_PRM_-0.34.pngMICH_PRM_-0.1.png
          Reply  Mon Oct 4 16:00:57 2021, Yehonathan, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements BS_PRM_ANG_ACT_TF_20211004.pdfBS_out_mat_20211004.txtPRM_out_mat_20211004.txt
             Reply  Mon Oct 4 16:10:09 2021, rana, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements 
             Reply  Tue Oct 5 20:04:22 2021, Paco, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements 
                Reply  Wed Oct 6 15:39:29 2021, Anchal, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements 
             Reply  Tue Oct 12 11:32:54 2021, Yehonathan, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements modified_output_matrices_radar_plots.pngnormal_output_matrices_radar_plots.png
                Reply  Tue Oct 12 16:39:52 2021, rana, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements 
                   Reply  Thu Oct 14 13:40:49 2021, Yehonathan, Summary, SUS, PRM and BS Angular Actuation transfer function magnitude measurements BSPRM_Actuation_Radar_plots.pngITM_Actuation_Radar_plots.png
Entry  Thu Oct 14 09:28:46 2021, Yehonathan, Update, PSL, PMC unlocked 
    Reply  Thu Oct 14 11:25:49 2021, Yehonathan, Update, PSL, PMC unlocked BS_OSEM_Sensor_PSD.pdfBS_OSEM_Sensor_PSD_AfterReconnectingCables.pdf
Entry  Wed Oct 13 15:36:38 2021, Hang, Update, Calibration, XARM OLTF Screenshot_2021-10-13_15-32-16.png
Entry  Fri Oct 8 17:33:13 2021, Hang, Update, SUS, More PRM L2P measurements Screenshot_2021-10-08_17-30-52.png
    Reply  Mon Oct 11 11:13:04 2021, rana, Update, SUS, More PRM L2P measurements 
    Reply  Mon Oct 11 13:59:47 2021, Hang, Update, SUS, More PRM L2P measurements prm_l2p_tf_meas_white.pdfprm_l2p_tf_meas_opt.pdfprm_l2p_fisher_vs_data_white_vs_opt.pdfprm_l2p_Pxx_evol_v2.pdf
Entry  Mon Sep 20 20:43:38 2021, Tega, Update, Electronics, Sat Amp modifications IMG_20210920_203456226.jpg
    Reply  Wed Sep 22 17:22:59 2021, Tega, Update, Electronics, Sat Amp modifications 
       Reply  Mon Oct 4 18:35:12 2021, Paco, Update, Electronics, Satellite amp box adapters pcb_no_flush.jpg1U_assembly.jpgfourunits.jpg
          Reply  Mon Oct 4 20:46:08 2021, Koji, Update, Electronics, Satellite amp box adapters 
             Reply  Thu Oct 7 02:04:19 2021, Koji, Update, Electronics, Satellite amp adapter chassis P_20211006_205044.jpg
Entry  Mon Oct 4 21:58:17 2021, Tega, Update, Electronics, Sat Amp modifications 
    Reply  Tue Oct 5 17:01:20 2021, Koji, Update, Electronics, Sat Amp modifications 
    Reply  Wed Oct 6 16:31:02 2021, Tega, Update, Electronics, Sat Amp modifications 
Entry  Wed Oct 6 15:04:36 2021, Hang, Update, SUS, PRM L2P TF measurement & Fisher matrix analysis prm_l2p_tf_meas.pdfprm_l2p_fisher_vs_data.pdfprm_l2p_Pxx_evol.pdfprm_l2p_fisher_evol.pdf
Entry  Mon Oct 4 15:50:31 2021, Hang, Update, Calibration, Fisher matrix estimation on XARM parameters tf_meas.pdffisher_est_vs_data.pdfPxx_evol.pdffisher_evol.pdf
Entry  Fri Oct 1 12:12:54 2021, Stephen, Update, BHD, ITMY (3002) CAD layout pushed to Box 3002_20211001_ITMY_BHD_for_Koji_presentation_images.easm40m_upgrade_layout_20200611-ITMY_Beam_Dim.pdf
Entry  Tue Sep 7 18:00:54 2021, Tega, Summary, Calibration, System Identification via line injection raw_timeseries.pdfdemod_signals.pdfcal_noise_asd.pdf
    Reply  Tue Sep 21 11:09:34 2021, Anchal, Summary, CDS, XARM YARM UGF Servo and Oscillators added 
       Reply  Wed Sep 22 12:40:04 2021, Anchal, Summary, CDS, XARM YARM UGF Servo and Oscillators shifted to OAF 
    Reply  Tue Sep 21 11:13:01 2021, Paco, Summary, Calibration, XARM calibration noise XARM_signal_asd.pdfXARM_demod_timeseries.pdfXARM_demod_asds.pdfXARM_cal_0921_timeseries.pdf
       Reply  Wed Sep 22 11:43:04 2021, rana, Summary, Calibration, XARM calibration noise 
          Reply  Tue Sep 28 16:31:52 2021, Paco, Summary, Calibration, XARM OLTF (calibration) at 55.511 Hz OLTF_Calibration_Scheme.jpgXARM_POX_Lock_Model_TF.pdfXARM_OLTF_Total_Model.pdfXARM_OLTF_55p511_Hz_timeseries.pdfGmag_55p511_Hz_ASD.pdf
             Reply  Thu Sep 30 18:04:31 2021, Paco, Summary, Calibration, XARM OLTF (calibration) with three lines XARM_OLTF_Model_and_Meas.pdfGmag_ASD_nb_withTRX.pdf
Entry  Mon Sep 13 09:15:15 2021, Paco, Update, LSC, MC unlocked? VAC_2021-09-13_09-32-45.png
    Reply  Mon Sep 13 15:14:36 2021, Anchal, Update, LSC, Xend Green laser injection mirrors M1 and M2 not responsive 
       Reply  Thu Sep 30 14:13:18 2021, Anchal, Update, LSC, HV supply to Xend Green laser injection mirrors M1 and M2 PZT restored 
Entry  Wed Sep 29 09:36:26 2021, Jordan, Update, SUS, 2" Adapter Ring Parts for SOS Arrived 9/28/21 20210929_092418.jpg
Entry  Thu Sep 23 14:17:44 2021, Tega, Update, Electronics, Sat Amp modifications debugging update 
Entry  Mon Sep 20 15:23:08 2021, Yehonathan, Update, Computers, Wifi internet fixed 
    Reply  Mon Sep 20 21:56:07 2021, Koji, Update, Computers, Wifi internet fixed 
Entry  Mon Sep 20 14:11:40 2021, Koji, Update, BHD, End DAC Adapter Unit D2100647 D2100647_End_DAC_Adapter.pdf
Entry  Fri Sep 17 20:22:55 2021, Koji, Update, SUS, EQ M4.3 Long beach 
Entry  Thu Sep 16 01:16:48 2021, Koji, Update, General, Frozen 2 P_20210916_003406_1.jpg
    Reply  Thu Sep 16 10:07:25 2021, Anchal, Update, General, Melting 2 PXL_20210916_170602832.jpg
       Reply  Thu Sep 16 20:18:13 2021, Anchal, Update, General, Reset PXL_20210917_031633702.jpg
          Reply  Fri Sep 17 00:56:49 2021, Koji, Update, General, Awesome 
Entry  Thu Sep 16 14:08:14 2021, Ian MacMillan, Frogs, , Tour 
Entry  Thu Sep 16 12:06:17 2021, Tega, Update, Computer Scripts / Programs, Temperature sensors added to the summary pages TempPlot_2021-09-16_12.04.19PM.png
Entry  Thu Sep 16 00:00:20 2021, Koji, Update, General, RIO Planex 1064 Lasers in the south cabinet P_20210915_232426.jpg
Entry  Wed Sep 1 21:55:14 2021, Koji, Summary, General, Towards the end upgrade 
    Reply  Wed Sep 15 23:53:54 2021, Koji, Summary, General, Towards the end upgrade P_20210915_231308.jpgP_20210915_225039.jpgP_20210915_224341.jpg
Entry  Wed Sep 15 23:38:32 2021, Koji, Update, ALS, ALS ASX PZT HV was off -> restored P_20210915_151333.jpg
Entry  Fri Mar 19 19:15:13 2021, Jon, Update, CDS, c1auxey assembly 
    Reply  Thu Mar 25 12:11:53 2021, Yehonathan, Update, CDS, c1auxey assembly 20210325_115500_HDR.jpg20210325_123033.jpg
       Reply  Thu Mar 25 14:16:33 2021, gautam, Update, CDS, c1auxey assembly 
       Reply  Tue Mar 30 17:27:04 2021, Yehonathan, Update, CDS, c1auxey assembly 
          Reply  Wed Aug 25 11:48:48 2021, Yehonathan, Update, CDS, c1auxey assembly 
             Reply  Mon Sep 13 14:32:25 2021, Yehonathan, Update, CDS, c1auxey assembly ETMX_OSEMS_Noise.png
                Reply  Wed Sep 15 11:27:50 2021, Yehonathan, Update, CDS, c1auxey assembly c1auxex_Grounding_OSEM_comparison1.pdfc1auxex_Grounding_OSEM_comparison2.pdf
       Reply  Thu Apr 15 17:24:08 2021, Jon, Update, CDS, Updated c1auxey wiring plan C1AUXEY_Chassis_Feedthroughs_-_By_Connector.pdf
          Reply  Mon Apr 19 21:54:55 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan 
             Reply  Wed Apr 28 18:56:57 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan 
                Reply  Thu Apr 29 16:35:51 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan 
                   Reply  Thu Apr 29 19:55:45 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan 
                      Reply  Fri Apr 30 19:18:51 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan 
                         Reply  Mon May 3 20:36:46 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan 
                            Reply  Sun May 23 18:28:54 2021, Jon, Update, CDS, Opto-isolator for c1auxey 
                               Reply  Fri May 28 10:54:59 2021, Jon, Update, CDS, Opto-isolator for c1auxey optoisolator.jpeg
                                  Reply  Thu Jun 3 17:15:17 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey Optical_Isolator_NPN_Input.pngOptical_Isolator_NPN_Output.png
                                     Reply  Thu Jun 3 22:08:00 2021, Koji, Update, CDS, Opto-isolator for c1auxey 
                                        Reply  Fri Jun 4 14:49:23 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey Optical_isolator_Wiring.pdf
                                           Reply  Fri Jun 4 17:46:25 2021, unYehonathan, Update, CDS, Opto-isolator for c1auxey 20210604_173420.jpg
                                              Reply  Sun Jun 6 16:33:47 2021, Jon, Update, CDS, BI channels on c1auxey 
                                                 Reply  Mon Jun 7 13:14:20 2021, Yehonathan, Update, CDS, BI channels on c1auxey 
                                                    Reply  Tue Jun 8 11:54:39 2021, Yehonathan, Update, CDS, BI channels on c1auxey 
                                           Reply  Sun Jun 6 03:02:14 2021, Koji, Update, CDS, Opto-isolator for c1auxey 
                                              Reply  Sun Jun 6 12:15:16 2021, Jon, Update, CDS, Opto-isolator for c1auxey 
                                              Reply  Sun Jun 6 15:59:51 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey Optical_isolator_Wiring.pdf
                                                 Reply  Mon Jun 14 15:31:30 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey Optical_isolator_Wiring.pdf
                                                    Reply  Tue Jun 15 21:48:55 2021, Koji, Update, CDS, Opto-isolator for c1auxey Acromag_RTS_BI_config.jpg
                                                       Reply  Wed Jun 16 17:24:29 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey Optical_isolator_Wiring.pdf
                                                          Reply  Wed Jun 16 20:32:39 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey 
                                                             Reply  Fri Jul 9 18:35:32 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey 
                                                                Reply  Mon Jul 12 18:06:25 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey 
                                                                   Reply  Wed Jul 28 12:47:52 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey SUS-ETMY_SparePDMon0_NoRef.pngSUS-ETMY_SparePDMon0_Ref_WithGND.pngDifferentialOutputTest.png
                                                                      Reply  Wed Aug 11 12:06:40 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey SUS-ETMY_SparePDMon0_2.png
Entry  Tue Sep 14 17:19:38 2021, Paco, Summary, PEM, Excess seismic noise in 0.1 - 0.3 Hz band SEIS_2021-09-14_17-33-12.png
    Reply  Tue Sep 14 19:12:03 2021, Koji, Summary, PEM, Excess seismic noise in 0.1 - 0.3 Hz band C1-ALL_393F21_SPECTRUM-1315699218-86400.pngC1-ALL_393F21_SPECTRUM-1315267218-86400.png
Entry  Tue Sep 14 15:57:05 2021, jamie, Frogs, CDS, fb1 /var full after reboot, caused all sorts of problems 
    Reply  Tue Sep 14 16:44:54 2021, jamie, Frogs, CDS, fb1 /var full after reboot, caused all sorts of problems 
       Reply  Tue Sep 14 17:22:21 2021, Anchal, Update, CDS, Added temp sensor channels to DAQ list 
Entry  Tue Sep 14 16:12:03 2021, Jordan, Update, SUS, SOS Tower Hardware 20210914_160111.jpg
    Reply  Tue Sep 14 17:14:46 2021, Koji, Update, SUS, SOS Tower Hardware 
Entry  Mon Sep 13 18:19:25 2021, Tega, Update, Computer Scripts / Programs, Moved modbus service from chiara to c1susaux 
Entry  Mon Sep 13 17:05:04 2021, Tega, Summary, PEM, Infrasensing temperature sensor modbus configuration 
Entry  Wed Aug 4 18:19:26 2021, paco, Update, General, Added infrasensing temperature unit to martian network 
    Reply  Thu Aug 5 14:59:31 2021, Anchal, Update, General, Added temperature sensors at Yend and Vertex too 
       Reply  Tue Aug 10 17:24:26 2021, paco, Update, General, Five day trend six_day_minute_trend.png
       Reply  Mon Sep 13 04:12:01 2021, Tega, Update, General, Added temperature sensors at Yend and Vertex too Screen_Shot_2021-09-13_at_4.16.22_AM.png
Entry  Fri Jun 11 20:19:50 2021, Koji, Summary, BHD, BHD OMC invacuum wiring 40mBHD_OMC_wiring.pdf
    Reply  Thu Sep 9 09:54:41 2021, Stephen, Summary, BHD, BHD OMC invacuum wiring - cable lengths bhd_cable_length_check_cable_bracket_to_components.pngbhd_cable_length_check_flange_to_cable_bracket.pngbhd_cable_length_check_cable_bracket_to_omc_bracket.png
Entry  Wed Sep 8 19:06:14 2021, Koji, Update, General, Backup situation 
Entry  Wed Sep 8 18:00:01 2021, Koji, Update, VAC, cronjobs & N2 pressure alert 
Entry  Thu Sep 2 17:53:15 2021, Paco, Summary, Computers, chiara down, vac interlock tripped 
    Reply  Thu Sep 2 21:21:14 2021, Koji, Summary, Computers, Vacuum recovery 2 Screenshot_2021-09-02_21-20-24.pngScreenshot_2021-09-02_21-20-48.png
    Reply  Thu Sep 2 21:49:03 2021, Paco, Summary, Computers, chiara down, vac interlock tripped 2021-09-02_21-51-15.png
       Reply  Fri Sep 3 02:03:15 2021, Tega, Summary, Computers, Strip down large error files 
Entry  Thu Sep 2 19:28:02 2021, Koji, Update, , This week's FB1 GPS Timing Issue Solved 
    Reply  Thu Sep 2 19:47:38 2021, Koji, Update, CDS, This week's FB1 GPS Timing Issue Solved 
       Reply  Thu Sep 2 20:44:18 2021, Koji, Update, CDS, Chiara DHCP restarted 
          Reply  Thu Sep 2 20:47:19 2021, Koji, Update, CDS, Chiara DHCP restarted 
Entry  Wed Sep 1 14:16:21 2021, Jordan, Update, VAC, Empty N2 Tanks 
Entry  Mon Aug 30 17:49:43 2021, Paco, Summary, LSC, XARM POX OLTF XARM_POX_OLTF.pdfXARM_POX_Coh.pdf
    Reply  Tue Aug 31 14:55:24 2021, rana, Summary, LSC, XARM POX OLTF 
Entry  Thu Aug 26 10:30:14 2021, Jamie, Configuration, CDS, front end time synchronization fixed? 
Entry  Tue Aug 24 18:44:03 2021, Koji, Update, CDS, FB is writing the frames with a year old date Screen_Shot_2021-08-24_at_18.46.24.png
    Reply  Wed Aug 25 17:31:30 2021, Paco, Update, CDS, FB is writing the frames with a year old date TRX_noise_2021-08-25_17-40-55.pngTRX_TRY_power_spectra.pdf
       Reply  Thu Aug 26 10:10:44 2021, Paco, Update, CDS, FB is writing the frames with a year old date Screenshot_from_2021-08-26_10-09-50.pngTRXTRY_Spectra.pdf
    Reply  Wed Aug 25 18:20:21 2021, Jamie, Update, CDS, GPS time on fb1 fixed, dadq writing correct frames again 
Entry  Wed Aug 25 08:53:33 2021, Jordan, Update, SUS, 2" Adapter Ring for SOS Arrived 8/24/21 20210824_152259.jpg20210824_152259.jpg20210824_152308.jpg
Entry  Wed Feb 24 22:13:47 2021, Jon, Update, CDS, Planning document for front-end testing 
    Reply  Fri Mar 5 17:48:25 2021, Jon, Update, CDS, Front-end testing image_67203585.JPGimage_67216641.JPGimage_17185537.JPG
       Reply  Tue Mar 9 16:52:47 2021, Jon, Update, CDS, Front-end testing image_72192707.JPG
          Reply  Tue Mar 16 16:27:22 2021, Jon, Update, CDS, Front-end testing 
             Reply  Tue Mar 16 19:04:20 2021, gautam, Update, CDS, Front-end testing 
             Reply  Fri Mar 19 18:14:56 2021, Jon, Update, CDS, Front-end testing image_72192707_(1).JPGimage_50412545.JPG
                Reply  Wed Mar 24 19:02:21 2021, Jon, Update, CDS, Front-end testing 
                   Reply  Mon Mar 29 17:55:50 2021, Jon, Update, CDS, Front-end testing 
                      Reply  Tue Mar 30 18:21:34 2021, Jon, Update, CDS, Front-end testing 
                      Reply  Tue Apr 6 07:19:11 2021, Jon, Update, CDS, New SimPlant cymac 
                         Reply  Tue Apr 6 11:13:01 2021, Jon, Update, CDS, FE testing 
                            Reply  Sat Apr 10 08:51:32 2021, Jon, Update, CDS, I/O Chassis Assembly 
                               Reply  Thu Apr 29 10:51:35 2021, Jon, Update, CDS, I/O Chassis Assembly 
                                  Reply  Tue May 4 07:38:36 2021, Jon, Update, CDS, I/O Chassis Assembly Screen_Shot_2021-05-03_at_4.16.06_PM.png
                                     Reply  Tue May 11 16:29:55 2021, Jon, Update, CDS, I/O Chassis Assembly Screen_Shot_2021-05-11_at_3.03.42_PM.png
                                        Reply  Tue May 11 17:43:09 2021, Koji, Update, CDS, I/O Chassis Assembly 
                                           Reply  Fri May 28 11:16:21 2021, Jon, Update, CDS, Front-End Assembly and Testing c1bhd.pnggds_tp.pngteststand.jpegbench_supply.jpeg
                                              Reply  Sun Jun 6 08:42:05 2021, Jon, Update, CDS, Front-End Assembly and Testing c1bhd.png16bit_dacs.pngmyricom.png
                                                 Reply  Tue Jun 22 16:53:01 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing 
                                                    Reply  Thu Jun 24 17:32:52 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing C1-SU2_Channel_Responses.pdfC1-BHD_Channel_Responses.pdfCDS_Channel_Test.zip
                                                       Reply  Fri Jun 25 14:06:10 2021, Jon, Update, CDS, Front-End Assembly and Testing test_stand.JPG
                         Reply  Sat Apr 10 11:56:14 2021, Jon, Update, CDS, 40m LSC simPlant model x1lsp_main.png
                            Reply  Tue Apr 13 16:24:38 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model 
                               Reply  Mon Apr 19 13:15:20 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model 
                                  Reply  Wed Apr 21 10:03:01 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model Overview.png
                                     Reply  Wed Apr 21 11:01:37 2021, Rana, Update, CDS, 40m LSC simPlant model 
                                     Reply  Fri Apr 23 15:52:19 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model Plant_framework.pdfSimple_Plant.pdfControls.pdf
                                        Reply  Sun Apr 25 21:21:02 2021, rana, Update, CDS, SUS simPlant model 
                                           Reply  Tue Apr 27 15:15:17 2021, Ian MacMillan, Update, CDS, SUS simPlant model x1sus_single_plant.pdfx1sup.pdf
                                              Reply  Thu Apr 29 13:41:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model Non-IPC_Plant.pdf
                                                 Reply  Fri Apr 30 12:52:14 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                    Reply  Mon May 3 13:35:12 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                       Reply  Tue May 4 14:55:38 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                          Reply  Wed May 5 15:11:54 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                             Reply  Thu May 6 16:13:24 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                                Reply  Fri May 7 11:19:29 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                                   Reply  Wed May 12 13:06:15 2021, Ian MacMillan, Update, CDS, SUS simPlant model SimplePlant_SingleContr.pdfx1sup_isolated.pdfX1SUP_ISOLATED_GDS_TP.pngX1SUP_ISOLATED_C1_SUS_SINGLE_PLANT_Plant_POS_Mod.png
                                                                      Reply  Fri May 21 09:44:52 2021, Ian MacMillan, Update, CDS, SUS simPlant model Transfer_Function_of_Damped_Harmonic_Oscillator.pdf
                                                                         Reply  Fri May 21 14:36:20 2021, Ian MacMillan, Update, CDS, SUS simPlant model Plant_Mod_TF.pdf
                                                                            Reply  Thu Jun 3 13:06:47 2021, Ian MacMillan, Update, CDS, SUS simPlant model SingleSusPlantTF.pdfSUS_PLANT_TF.zip
                                                                               Reply  Mon Jun 7 17:49:19 2021, Ian MacMillan, Update, CDS, SUS simPlant model SingleSusPlantTF.pdfTF_Graph_Code.zip
                                                                                  Reply  Wed Jun 9 13:50:48 2021, Ian MacMillan, Update, CDS, SUS simPlant model SingleSusPlantTF.pdf
                                                                                     Reply  Tue Jun 15 11:46:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model x1sup_isolated-6-15-v1.pdfC1_SUS_SINGLE_PLANT-6-15-v1.pdf
                                                                                     Reply  Wed Jun 30 14:09:26 2021, Ian MacMillan, Update, CDS, SUS simPlant model SingleSusPlantTF.pdfPlant_TF_Test.zip
                                                                                        Reply  Mon Aug 23 15:25:59 2021, Ian MacMillan, Update, CDS, SUS simPlant model SimPlantStateSpace.zip
Entry  Mon Aug 23 10:17:21 2021, Paco, Summary, Computers, system reboot glitch 
Entry  Mon Aug 16 23:30:34 2021, Paco, Update, CDS, AS WFS commissioning; restarting models 
    Reply  Thu Aug 19 03:23:00 2021, Anchal, Update, CDS, Time synchornization not running 
       Reply  Thu Aug 19 14:14:49 2021, Koji, Update, CDS, Time synchornization not running 
          Reply  Fri Aug 20 00:28:55 2021, Anchal, Update, CDS, Time synchornization not running 
             Reply  Fri Aug 20 06:24:18 2021, Anchal, Update, CDS, Time synchornization not running 
Entry  Wed Aug 18 20:30:12 2021, Anchal, Update, ASS, Fixed runASS scripts 
Entry  Fri May 21 00:05:45 2021, Koji, Update, SUS, New electronics: Sat Amp / Coil Drivers F3CDEF8D-4B1E-42CF-8EFC-EA1278C128EB_1_105_c.jpeg
    Reply  Thu Jun 17 22:25:38 2021, Koji, Update, SUS, New electronics: Sat Amp / Coil Drivers P_20210604_231028.jpeg
       Reply  Wed Jul 21 14:50:23 2021, Koji, Update, SUS, New electronics P_20210629_183950.jpegP_20210719_135938.jpeg
          Reply  Tue Aug 17 04:30:35 2021, Koji, Update, SUS, New electronics P_20210816_234136.jpgP_20210816_235106.jpgP_20210816_234220.jpg
Entry  Thu Aug 12 11:04:27 2021, Paco, Update, General, PSL shutter was closed this morning 
    Reply  Thu Aug 12 14:59:25 2021, Koji, Update, General, PSL shutter was closed this morning Screen_Shot_2021-08-12_at_14.58.59.png
       Reply  Thu Aug 12 20:52:04 2021, Koji, Update, General, PSL shutter was closed this morning Screen_Shot_2021-08-12_at_20.51.19.pngScreen_Shot_2021-08-12_at_20.51.34.png
Entry  Wed Aug 11 11:35:36 2021, Paco, Update, LSC, PRMI MICH orthogonality plan 
Entry  Fri Aug 6 13:13:28 2021, Anchal, Update, BHD, c1teststand subnetwork now accessible remotely 
    Reply  Mon Aug 9 10:38:48 2021, Anchal, Update, BHD, c1teststand subnetwork now accessible remotely 
Entry  Fri Aug 6 17:10:19 2021, Paco, Update, IMC, MC rollercoaster MC2_trans_sum_2021-08-06_17-18-54.png
Entry  Tue Aug 3 20:20:08 2021, Anchal, Update, Optical Levers, Recentered ETMX, ITMX and ETMY oplevs at good state 
Entry  Mon Aug 2 16:18:23 2021, Paco, Update, ASC, AS WFS MICH commissioning 
Entry  Thu Jul 29 14:51:39 2021, Paco, Update, Optical Levers, Recenter OpLevs 
Entry  Wed Jul 28 20:20:09 2021, Yehonathan, Update, General, The temperature sensors and function generator have arrived in the lab 20210728_201313.jpg20210728_201607.jpg
Entry  Wed Mar 24 00:51:19 2021, gautam, Update, LSC, Schnupp asymmetry Lsch.pdf
    Reply  Wed Jul 28 17:10:24 2021, Anchal, Update, LSC, Schnupp asymmetry Lsch.pdf
Entry  Tue Jul 27 23:04:37 2021, Anchal, Update, LSC, 40 meter party Screenshot_2021-07-27_22-19-58.png
Entry  Wed Jul 21 18:08:35 2021, yehonathan, Update, Loss Measurement, Loss measurement 
    Reply  Thu Jul 22 16:06:10 2021, Paco, Update, Loss Measurement, Loss measurement 
       Reply  Sun Jul 25 20:41:47 2021, rana, Update, Loss Measurement, Loss measurement 
          Reply  Mon Jul 26 17:34:23 2021, Paco, Update, Loss Measurement, Loss measurement LossMeasurement_RawData.pdfYARM_loss_stats.pdfXARM_loss_stats.pdf
Entry  Sat Jul 17 00:52:33 2021, Koji, Update, General, Canon camera / small silver tripod / macro zoom lens / LED ring light borrowed -> QIL P_20210716_213850.jpg
    Reply  Sun Jul 25 18:21:10 2021, Koji, Update, General, Canon camera / small silver tripod / macro zoom lens / LED ring light returned / Electronics borrowed 
Entry  Mon Jul 19 22:16:08 2021, paco, Update, LSC, PRFPMI locking 
Entry  Fri Jul 16 16:26:50 2021, gautam, Update, Computers, Docker installed on nodus 
Entry  Wed Jul 14 20:42:04 2021, gautam, Update, LSC, Locking 
    Reply  Thu Jul 15 14:25:48 2021, Paco, Update, LSC, CM board high_BW_TFs.pdf
Entry  Wed Jun 16 19:34:18 2021, Koji, Update, General, HVAC HVAC_Power.jpegSouth_Arm.jpegSouth_End_Tenperature.jpegVertex.jpegEast_Arm.jpeg
    Reply  Wed Jul 14 16:19:44 2021, gautam, Update, General, Brrr rmTemp.pdf
       Reply  Wed Jul 14 19:21:44 2021, Koji, Update, General, Brrr 
Entry  Tue May 25 17:42:11 2021, Anchal, Paco, Summary, ALS, ALS Single Arm Noise Budget ALS_IR_b.svgALS_Single_Arm_IR.pdf
    Reply  Thu May 27 11:03:15 2021, Anchal, Paco, Summary, ALS, ALS Single Arm Noise Budget ALS_Single_X_Arm_IR.pdfALS_OOL_with_Ref.pdf
       Reply  Fri May 28 17:32:48 2021, Anchal, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat SingleArmActCalwithIRALSBeat.pdfstateSpaceModel.zip
          Reply  Tue Jun 1 16:55:32 2021, Anchal, Paco, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat SingleArmActCalwithIRALSBeat-1306624785.pdf
             Reply  Tue Jun 8 11:40:53 2021, Anchal, Paco, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat ITMX_Cal_Noise_Spectrum_1307143423.pdf
                Reply  Wed Jun 9 18:29:13 2021, Anchal, Paco, Summary, ALS, Check for saturation in ITMX SOS Driver 
                Reply  Fri Jul 9 15:39:08 2021, Anchal, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat [Correction] ITMX_calibration_With_ALS_Beat.pdf
Entry  Thu Jul 8 11:20:38 2021, Anchal, Paco, Gautam, Summary, LSC, PRFPMI locking attempts 
Entry  Tue Jul 6 10:47:07 2021, Paco, Anchal, Update, IOO, Restored MC 
    Reply  Tue Jul 6 16:35:04 2021, Anchal, Paco, Gautam, Update, IOO, Restored MC 
Entry  Fri Jul 2 12:42:56 2021, Anchal, Paco, Gautam, Summary, LSC, snap file changed for MICH 
Entry  Wed Jun 30 15:31:35 2021, Anchal, Summary, Optical Levers, Centered optical levers on ITMY, BS, PRM and ETMY 
    Reply  Thu Jul 1 16:55:21 2021, Anchal, Summary, Optical Levers, Fixed Centeringoptical levers PRM 
Entry  Thu Jul 1 11:37:50 2021, Paco, Update, General, restarted c0rga 
Entry  Wed Jun 30 18:44:11 2021, Anchal, Summary, LSC, Tried fixing ETMY QPD 
    Reply  Thu Jul 1 10:34:51 2021, Paco, Anchal, Summary, LSC, ETMY QPD fixed 
Entry  Tue Jun 29 17:42:06 2021, Anchal, Paco, Gautam, Summary, LSC, MICH locking tutorial with Gautam 
Entry  Sun Sep 6 14:17:18 2020, Jon, Update, Equipment loan, Zurich Instruments analyzer 
    Reply  Fri Jun 25 19:14:45 2021, Jon, Update, Equipment loan, Zurich Instruments analyzer ZI.JPG
Entry  Mon Dec 7 11:25:31 2020, gautam, Update, SUS, MC1 suspension glitchy again 
    Reply  Wed Dec 9 16:22:57 2020, gautam, Update, SUS, Yet another round of Sat. Box. switcharoo WFS2.pngWFS_lineNoise.pngWFSchar.pdf
       Reply  Sun Jan 3 16:26:06 2021, Koji, Update, SUS, IMC WFS check (Yet another round of Sat. Box. switcharoo) Screen_Shot_2021-01-03_at_17.14.57.png
    Reply  Thu May 13 11:55:04 2021, Anchal, Paco, Update, SUS, MC1 suspension misbehaving Screenshot_from_2021-05-13_09-50-24.pngMC1_Glitches_Invest2.pdf
       Reply  Thu May 13 19:38:54 2021, Anchal, Update, SUS, MC1 Satellite Amplifier Debugged MC1_UL_Channel_Fixed.png
          Reply  Mon May 24 19:14:15 2021, Anchal, Paco, Summary, SUS, MC1 Free Swing Test set to trigger 
             Reply  Tue May 25 10:22:16 2021, Anchal, Paco, Summary, SUS, MC1 new input matrix calculated and uploaded SUS_Input_Matrix_Diagonalization.pdf
          Reply  Thu Jun 17 11:45:42 2021, Anchal, Paco, Update, SUS, MC1 Gave trouble again SummaryScreenShot.pngMC1_LL_SENSOR_DEAD.png
             Reply  Thu Jun 17 16:37:23 2021, Anchal, Paco, Update, SUS, c1susaux computer rebooted 
                Reply  Tue Jun 22 11:56:16 2021, Anchal, Paco, Update, SUS, ADC/Slow channels issues CDS_FE_Status.png
                   Reply  Tue Jun 22 16:52:28 2021, Paco, Update, SUS, ADC/Slow channels issues shake_and_damp.png
                      Reply  Wed Jun 23 09:05:02 2021, Anchal, Update, SUS, MC lock acquired back again 
                         Reply  Thu Jun 24 16:40:37 2021, Koji, Update, SUS, MC lock acquired back again P_20210624_163641_1.jpg
Entry  Thu Jun 17 11:19:37 2021, Ian MacMillan, Update, CDS, CDS Upgrade 
    Reply  Mon Jun 21 17:15:49 2021, Ian MacMillan, Update, CDS, CDS Upgrade DAC2ADC_Test.py
Entry  Fri Jun 18 14:53:37 2021, Anchal, Summary, PEM, Temperature sensor network proposal 40mTempSensors.pdf
Entry  Wed Jun 9 11:46:01 2021, Anchal, Paco, Summary, AUX, Xend Green Laser PDH OLTF measurement image-6f2923a3-01ce-4d04-bc53-d8db0238e195.jpgimage-72223f4b-3b74-4574-a7ad-de6628a2c5e9.jpgX_Green_ARM_PDH_OLTF.pdf
    Reply  Thu Jun 10 14:01:36 2021, Anchal, Summary, AUX, Xend Green Laser PDH OLTF measurement loop algebra AUX_PDH_LOOP.pdf
       Reply  Mon Jun 14 18:57:49 2021, Anchal, Update, AUX, Xend is unbearably hot. Green laser is loosing lock in 10's of seconds XAUX_PDH_Err_In_ASD.pdfXAUX_PZT_Out_Mon_ASD.pdf
       Reply  Tue Jun 15 15:26:43 2021, Anchal, Paco, Summary, AUX, Xend Green Laser PDH OLTF measurement loop algebra, excitation at control point AuxPDHloop.pdf
          Reply  Fri Jun 18 10:07:23 2021, Anchal, Paco, Summary, AUX, Xend Green Laser PDH OLTF with coherence XEND_PDH_OLTF_with_Coherence.pdfBeta_Amp.pdf
Entry  Thu Jun 17 22:19:12 2021, Koji, Update, Electronics, 25 HAM-A coil driver units delivered P_20210617_195811.jpg
Entry  Mon Jun 7 15:37:01 2021, Anchal, Paco, Yehonathan, Summary, Cameras, Mon 7 in Control Room Died 
    Reply  Wed Jun 16 13:20:19 2021, Anchal, Paco, Summary, Cameras, Mon 7 in Control Room Replaced IMG_20210616_083810.jpg
Entry  Wed Jun 2 17:50:50 2021, Paco, Update, Equipment loan, Borrow red cart IMG_20210602_172858.jpg
    Reply  Thu Jun 3 17:49:46 2021, Paco, Update, Equipment loan, Borrow red cart 
Entry  Wed Mar 10 11:46:22 2021, Paco, Anchal, Summary, IMC, IMC free swinging prep 
    Reply  Wed Mar 10 15:00:16 2021, gautam, Summary, IMC, IMC free swinging prep 
       Reply  Wed Mar 10 15:29:58 2021, Anchal, Summary, IMC, IMC free swinging prep 
          Reply  Thu Jun 3 17:35:31 2021, Anchal, Summary, IMC, Fixed medm button C1IOO_Mech_Shutters.png
    Reply  Wed Mar 10 15:35:25 2021, Paco, Anchal, Summary, IMC, IMC free swinging experiment set to trigger at 5:00 am freeSwingMC.py.zip
Entry  Mon Mar 8 12:01:02 2021, Paco, Anchal, Summary, training, Investigate how-to XARM locking 
    Reply  Mon Mar 8 12:40:35 2021, gautam, Summary, training, Investigate how-to XARM locking 
    Reply  Mon Mar 8 19:22:56 2021, rana, Summary, SUS, IMC suspension characterization 
       Reply  Thu Mar 11 08:13:24 2021, Paco, Anchal, Update, SUS, IMC First Free Swing Test failed due to typo, restarting now 
          Reply  Tue Mar 16 19:13:09 2021, Paco, Anchal, Update, SUS, First success in Input Matric Diagonalization IMC_InputMatrixDiagonalization.pdfInMatCalcScripts.zip
             Reply  Wed Mar 17 11:57:54 2021, Paco, Anchal, Update, SUS, Tested New Input Matrix for MC1 20210317_MC1_InMATtest.pdfMC1_Input_Matrix_Test.tar.gz
                Reply  Wed Mar 17 16:30:46 2021, Anchal, Update, SUS, Normalized Input Matrices plotted better than SURF students IMC_InputMatrixDiagonalization.pdfNewAndOldMatrices.zip
                   Reply  Thu Mar 18 09:18:49 2021, Paco, Anchal, Update, SUS, Testing of new input matrices with new data MC_Optics_Kicked_Time_Series_1.pdfTEST_Input_Matrix_Diagonalization.pdf
                      Reply  Thu Mar 18 12:46:53 2021, rana, Update, SUS, Testing of new input matrices with new data 
                         Reply  Fri Mar 19 10:49:44 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance 
                            Reply  Mon Mar 22 11:57:21 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance 210322_MC1_ASCY.pdfNewandOldMatrices.tar.gz
                               Reply  Mon Mar 22 15:10:00 2021, rana, Update, SUS, Trying coil actuation balance 
                                  Reply  Mon Mar 22 19:07:50 2021, Paco, Anchal, Update, SUS, Trying coil actuation balance 8x
                                     Reply  Tue Mar 23 09:16:42 2021, Paco, Anchal, Update, Computers, Power cycled C1PSL; restored C1PSL MCWFS1and2PITYAW.pdfMCWFS1and2PITYAW_Zoomed.pdf
                                        Reply  Wed Mar 24 09:23:49 2021, Paco, Update, SUS, MC3 new Input Matrix 
                                           Reply  Thu Mar 25 11:46:31 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates CoilActuationBalancing.ipynb.tar.gzMC2_CoilBalancePITnorm_excSamePIT.pdfMC2_CoilBalanceYAWnorm_excSameYAW.pdf20210325_IMC_CoilBalance.tar.gz
                                              Reply  Thu Mar 25 15:31:24 2021, gautam, Update, IOO, WFS servos 
                                              Reply  Fri Mar 26 11:54:37 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates 
                                                 Reply  Mon Mar 29 10:44:51 2021, Paco, Anchal, Update, SUS, MC2 Coil Balancing updates MC2OutMatCrossCouple_Old-to-It3.pdf20210329_MC2_CrossCoupleTest.tar.gz
                                                    Reply  Mon Mar 29 17:11:54 2021, gautam, Update, SUS, MC2 Coil Balancing updates 
                                                       Reply  Mon Mar 29 17:34:52 2021, rana, Update, SUS, MC2 Coil Balancing updates 
                                                          Reply  Wed Mar 31 22:58:32 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test 
                                                             Reply  Thu Apr 1 13:56:49 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test Results SDistanceFromIdentity.pdfSmatIterations.pdfTestingExcitationAlongYAW.pdf
                                                                Reply  Thu Apr 1 18:01:06 2021, Anchal, Paco, Update, SUS, MC2 Coil Balancing Test Results Success?? SDistanceFromIdentity.pdfSmatIterations.pdfMC2CoilCrossCoupling_opt.png
                                                                   Reply  Thu Apr 1 18:48:45 2021, gautam, Update, SUS, MC2 Coil Balancing Test Results Success?? 
                                                                      Reply  Thu Apr 1 21:13:54 2021, Anchal, Update, SUS, Matrix results, new measurement set to trigger 
                                                                         Reply  Fri Apr 2 14:51:20 2021, Anchal, Update, SUS, Bug found, need to redo the balancing 
                                                                            Reply  Tue Apr 6 18:46:36 2021, Anchal, Paco, Update, SUS, Updates on recent efforts FirstMeasurementPlots.pdf
                                                                               Reply  Wed Apr 7 17:38:51 2021, Anchal, Update, SUS, Trying to uncouple only PIT and YAW first SDistanceFromIdentity.pdfSmatIterations.pdfTimeSeriesPlots.pdfCSDPlots.pdfSmatrixPlots.pdf
                                                                                  Reply  Thu Apr 8 17:04:43 2021, Anchal, Paco, Update, SUS, First Successful Coil Balancing SDistanceFromIdentity.pdfSmatIterations.pdfSmatrixPlots.pdf
                                                                                     Reply  Fri Apr 9 13:13:00 2021, Anchal, Paco, Update, SUS, Faster coil balancing SmatIterations.pdfMC2AllOutmat.txt
                                                                                        Reply  Fri Apr 9 17:41:12 2021, rana, Update, SUS, Faster coil balancing 
                                                                                           Reply  Mon Apr 12 10:07:35 2021, Anchal, Update, SUS, What's F2A?? 
                                                                                              Reply  Tue Apr 13 09:51:22 2021, rana, Update, SUS, What's F2A?? 
                                                                                                 Reply  Wed Apr 14 17:53:38 2021, Anchal, Update, SUS, Plan for calculating filter banks for output matrix aka F2A aka F2P MC2propF2A_UL.pdf
                                                                                                    Reply  Thu Apr 15 11:41:43 2021, Anchal, Update, SUS, Proposed filters for output matrix aka F2A aka F2P MC2propPOSfb.pdf
                                                                                                       Reply  Fri Apr 16 11:36:36 2021, Anchal, Paco, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix 20210416_MC2DCcoilBalancingNoFilters.pdfuncFilters.pdf20210416_MC2DCcoilBalancingWithFilters.pdfuncFilters_v2.pdf20210416_MC2DCcoilBalancingWithFilters_v2.pdf
                                                                                                          Reply  Fri Apr 16 15:47:58 2021, rana, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix 
                                                                                                             Reply  Mon Apr 19 12:18:19 2021, Anchal, Paco, Update, SUS, Tested proposed filters for POS colum in MC2 output matrix CrossCoupleTestForEgToCtFilters.pdfuncFilters.pdfuncFilters_v2.pdf
                                                                                                                Reply  Tue Apr 20 10:52:49 2021, Anchal, Paco, Update, SUS, AC gain coil output balancing for IMC POS2PYuncoupled.pdfPIT2PYuncoupled.pdfMC1YAWexc.pdfMC1PITexc.pdf
                                                                                                                   Reply  Tue Apr 20 18:19:30 2021, Anchal, Update, SUS, MC2 coil balanced at DC MC2_DC_Coil_Balanced_St.pngIMC_F2A_Params_MC2.pdfUploadedPOS_F2A_Filters.pdf
                                                                                                                      Reply  Wed Apr 21 11:38:27 2021, Anchal, Paco, Update, SUS, MC2 Damping Gains Optimized MC2_DampGainStepTestWithNewGains.pngMC2_DampGainStepTestWithOldGains.png
                                                                                                                         Reply  Wed Apr 21 15:50:01 2021, Anchal, Paco, Update, SUS, MC2 Suspension Optimization summary 
                                                                                                                            Reply  Wed Apr 21 18:49:29 2021, rana, Update, SUS, MC2 Suspension Optimization summary 
                                                                                                                               Reply  Thu Apr 22 08:50:21 2021, Anchal, Update, SUS, MC2 Suspension Optimization summary 
                                                                                                                            Reply  Mon Apr 26 18:55:39 2021, Anchal, Paco, Update, SUS, MC2 F2A Filters Tested f2a.pdfIMC_F2A_Params_MC2.pdfMC2_F2A_FilterChar_POS2Ang.pdf
                                                                                                                               Reply  Tue Apr 27 10:05:28 2021, Anchal, Paco, Update, SUS, MC1 and MC3 F2A Filters Tested IMC_F2A_Params_MC1.pdfMC1_POStoAng_CrossCoupling.pdfIMC_F2A_Params_MC3.pdfMC3_POStoAng_CrossCoupling.pdf
                                                                                                                                  Reply  Wed Apr 28 10:56:10 2021, Anchal, Paco, Update, SUS, IMC Filters diagnosed 7x
                                                                                                                                     Reply  Wed Apr 28 17:09:11 2021, Anchal, Update, SUS, Tuned Suspension Parameters uploaded for long term behavior monitoring 
                                                                                                                                     Reply  Thu Apr 29 10:52:56 2021, Anchal, Update, SUS, IMC Trans QPD and WFS loops step response test PIT_OFFSET_ON_MC2.pngYAW_STEP_ON_MC2_complete.png
                                                                                                                                        Reply  Thu Apr 29 18:53:33 2021, Anchal, Update, SUS, IMC Suspension Damping Gains Test MC1_SUSDampGainTest.pdfMC2_SUSDampGainTest.pdfMC3_SUSDampGainTest.pdf
                                                                                                                                           Reply  Mon May 3 16:24:14 2021, Anchal, Update, SUS, IMC Suspension Damping Gains Test Repeated with IMC unlocked MC1_SusDampGainTest.pdfMC2_SusDampGainTest.pdfMC3_SusDampGainTest.pdf
                                                                                                                                              Reply  Wed May 5 09:04:47 2021, Anchal, Update, SUS, New IMC Suspension Damping Gains uploaded for long term testing 
                                                                                                                                                 Reply  Wed May 12 11:45:13 2021, Anchal, Paco, Summary, SUS, New IMC Settings are miserable MC_F_Comparison.pdfMC_TRANS_QPD_Comparison.pdfIMC_REFL_DC_Comparison.pdf
                                                                                                                                                    Reply  Wed Jun 2 09:43:30 2021, Anchal, Paco, Summary, SUS, IMC Settings characterization seismicX.pdfseismicXtoMC_F_TFest.pdfseismicXtoMC_TRANS_PIT_TFest.pdfseismicXtoMC_TRANS_YAW_TFest.pdf
                                                                                                                                                       Reply  Wed Jun 2 16:20:59 2021, Anchal, Paco, Summary, SUS, IMC Suspension gains reverted to old values 
                                                                                                                                                 Reply  Sat May 15 14:54:24 2021, gautam, Update, SUS, IMC settings reverted MC2coilOut.png
                                                                                                                                                    Reply  Thu May 20 10:35:57 2021, Anchal, Update, SUS, IMC settings reverted 
                                                                                                                         Reply  Thu Apr 22 12:17:23 2021, Anchal, Paco, Update, SUS, MC1 and MC3 Suspension Optimization Summary 
                                                                                                                            Reply  Thu Apr 22 14:22:39 2021, gautam, Update, SUS, Settings restored MCdamping.png
                                                                                                                               Reply  Thu Apr 22 15:36:54 2021, Anchal, Update, SUS, Settings restored 
                                                                                                                                  Reply  Thu Apr 22 17:04:17 2021, gautam, Update, SUS, Settings restored 
                                                                                        Reply  Sat Apr 10 10:07:47 2021, rana, Update, SUS, Faster coil balancing 
                                                                         Reply  Fri Apr 2 15:22:54 2021, gautam, Update, SUS, Matrix results, new measurement set to trigger 
                                           Reply  Sun Mar 28 14:16:25 2021, Anchal, Summary, SUS, MC3 new Input Matrix not providing stable loop MC3_Input_Matrix_Diagonalization.pdf
                                              Reply  Mon Mar 29 17:07:17 2021, gautam, Summary, SUS, MC3 new Input Matrix not providing stable loop 
                      Reply  Thu Mar 18 13:12:39 2021, gautam, Update, Computer Scripts / Programs, Omnigraffle vs draw.io 
Entry  Thu May 27 14:11:15 2021, Jordan, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring CoM_to_Clamp.PNGCoM_to_Clamp_2.PNG
    Reply  Tue Jun 1 14:26:23 2021, Jordan, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring CoM_to_Clamp_Updated.PNG
       Reply  Wed Jun 2 01:08:57 2021, Koji, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring 
Entry  Wed May 26 11:45:57 2021, Anchal, Paco, Configuration, IMC, MC2 analog camera 
Entry  Wed May 26 02:00:44 2021, gautam, Update, Electronics, Coil driver noise coilDriverTopologies.pdfshotVthermal.pdf
Entry  Tue May 25 17:08:17 2021, Chub, Update, Electronics, chassis rework complete! 40M_chassis_reworked_5-25-21.jpg
Entry  Mon May 24 20:55:00 2021, Koji, Summary, BHD, How to align two OMCs on the BHD platform? 
Entry  Mon May 24 10:19:54 2021, Paco, Update, General, Zita IOO strip Screenshot_from_2021-05-24_18-09-37.png24and25_05_2021_PEM_BS_10_30.png
Entry  Mon May 24 08:38:26 2021, Chub, Update, Electronics, 18-bit AI, 16-bit AI and 16-bit AA 
Entry  Fri May 21 12:12:11 2021, Paco, Update, NoiseBudget, AUX PDH loop identification 
Entry  Fri May 21 00:15:33 2021, Koji, Update, Electronics, DC Power Strip delivered / stored 9x
Entry  Thu Aug 20 00:21:51 2020, gautam, Update, Electronics, First look at HV coil driver IMG_8724.JPGtimeDomain.pdfHVampNoise.pdf
    Reply  Sun Aug 23 23:36:58 2020, gautam, Update, Electronics, First look at HV coil driver IMG_5379.JPGstabilityCriterion.pdf
       Reply  Wed Aug 26 16:12:25 2020, gautam, Update, Electronics, Test mass coil current requirements coilCurrents.png
       Reply  Tue Sep 1 15:39:04 2020, gautam, Update, Electronics, HV coil driver oscillations fixed testSetup.pdfHVampNoise_driven.pdf
          Reply  Thu Oct 22 11:14:47 2020, gautam, Update, Electronics, HV coil driver packaged into 2U chassis HVampNoise_driven_chassis.pdfHVampNoise_dispUnits.pdfD1900163_measurementSetup.zip
             Reply  Thu Oct 22 13:04:42 2020, rana, Update, Electronics, HV coil driver packaged into 2U chassis 
                Reply  Thu Oct 22 22:01:53 2020, gautam, Update, Electronics, HV coil driver packaged into 2U chassis DACnoiseFilterGain.pdfDACnoiseFilterNoises.pdf
                   Reply  Fri Oct 23 09:03:43 2020, anchal, Update, Electronics, HV coil driver packaged into 2U chassis 
             Reply  Thu Nov 12 14:55:35 2020, gautam, Update, Electronics, More systematic noise characterization powerSupplyNoise.pdfcoherence.pdf
                Reply  Thu Nov 12 15:40:42 2020, Koji, Update, Electronics, More systematic noise characterization 
                   Reply  Mon Nov 16 00:02:34 2020, rana, Update, Electronics, More systematic noise characterization 
                      Reply  Wed Jan 20 10:13:06 2021, gautam, Update, Electronics, HV Power supply bypassing bypassCaps.pdfIMG_9079.jpgIMG_9078.jpgHVampNoise_driven_chassis.pdfprintCoilCurrents.pdf
                         Reply  Mon Feb 1 12:30:21 2021, gautam, Update, Electronics, More careful characterization HVPS.pdfHV_testckt.pdftotalNoise.pdf
                         Reply  Wed Feb 10 21:14:03 2021, gautam, Update, Electronics, Production version of the HV coil driver tested inputDiffRecTF.pdfLVnoises.pdftotalNoise.pdftimeDomainTests.pdf
                            Reply  Fri Feb 26 16:31:02 2021, gautam, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies totalNoise_KEPCO.pdf
                               Reply  Fri Feb 26 20:20:43 2021, Koji, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies 
                                  Reply  Sat Feb 27 17:25:42 2021, gautam, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies 
                                     Reply  Thu May 20 16:56:21 2021, Koji, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies P_20210520_154523_copy.jpg
Entry  Wed May 12 14:23:20 2021, Jordan, Update, SUS, Mass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units Moments_of_Inertia_SI.PNG
    Reply  Wed May 12 16:53:59 2021, Koji, Update, SUS, Mass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units 
       Reply  Wed May 12 17:06:52 2021, Jordan, Update, SUS, Mass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units Moments_of_Inertia_SI.PNG
          Reply  Wed May 19 18:29:41 2021, Koji, Update, SUS, Mass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units SOS_resonant_freq.pdfSOS_resonant_freq.nb.zip
Entry  Wed Apr 21 19:28:03 2021, Anchal, Update, PSL, PSL/IFO recovery 
    Reply  Wed Apr 21 19:43:20 2021, Koji, Update, PSL, New HEPA speed control P_20210421_193637.jpgP_20210421_193627.jpg
       Reply  Thu Apr 22 14:41:55 2021, Chub, Update, PSL, New HEPA speed control 40M_PSL_HEPA.jpg
          Reply  Fri Apr 23 18:00:02 2021, gautam, Update, PSL, HEPA speed lowered HEPAdiag.pdf
             Reply  Fri Apr 23 19:26:58 2021, Koji, Update, PSL, HEPA speed lowered 
             Reply  Fri May 14 17:45:05 2021, rana, Update, PSL, HEPA speed raised 
                Reply  Tue May 18 00:52:38 2021, rana, Update, PSL, HEPA speed raised Untitled.png
                   Reply  Tue May 18 20:26:11 2021, rana, Update, PSL, HEPA speed raised 
    Reply  Thu Apr 22 15:15:26 2021, gautam, Update, PSL, PMC transmission 
       Reply  Thu Apr 22 15:34:54 2021, Anchal, Update, PSL, PMC transmission 
Entry  Sat May 15 12:39:54 2021, gautam, Update, PSL, NPRO tripped/switched off NPRO.png
Entry  Fri May 14 03:29:50 2021, Koji, Update, Electronics, HV Driver noise test with the new HV power supply from Matsusada HV_Driver_PSD.pdf
Entry  Thu Apr 29 11:51:27 2021, Anchal, Summary, LSC, Start of measuring IMC WFS noise contribution in ar cavity length noise 
    Reply  Thu Apr 29 15:11:33 2021, gautam, Update, CDS, RFM  RFM_errs.pngScreenshot_2021-04-29_15-12-56.png
       Reply  Thu Apr 29 17:43:16 2021, Koji, Update, CDS, RFM  
       Reply  Thu Apr 29 17:43:48 2021, Anchal, Update, CDS, F2A Filters double check F2AFiltersON.png
          Reply  Fri Apr 30 00:20:30 2021, gautam, Update, CDS, F2A Filters double check 
    Reply  Thu Apr 29 17:51:19 2021, Anchal, Summary, LSC, Start of measuring IMC WFS noise contribution in arm cavity length noise WFS1_PIT_exc_80-100Hz_Arms_ASD.pdf
       Reply  Fri Apr 30 00:18:40 2021, gautam, Summary, LSC, Start of measuring IMC WFS noise contribution in arm cavity length noise 
       Reply  Mon May 3 09:14:01 2021, Anchal, Paco, Update, LSC, IMC WFS noise contribution in arm cavity length noise WFS1_PIT_Noise_Inj_Test_IMC_unlocked.pdfWFS1_PIT_Noise_Inj_Test_ARM_locked.pdf
          Reply  Mon May 3 17:28:58 2021, Anchal, Paco, Rana, Update, LSC, IMC WFS noise contribution in arm cavity length noise excitationoftheMCanglessothatwecanseesomethingdotpng.pngexcitationoftheMCanglessothatwecanseesomethingdotpngbutthistimeitsMC2.png
             Reply  Tue May 4 11:43:09 2021, Anchal, Paco, Update, LSC, IMC WFS noise contribution in arm cavity length noise ArmCavNoiseContributions.pdfIOO-MC1_PIT_NoiseInjTest2.pdfIOO-MC1_PIT_NoiseInjTest_AWGGUI_Config.png
                Reply  Fri May 7 11:54:02 2021, Anchal, Paco, Update, LSC, IMC WFS noise contribution in arm cavity length noise ITMX-XARM_TF.pdfITMY-YARM_TF.pdfArmCavNoiseContributions.pdf
                   Reply  Mon May 10 18:19:12 2021, Anchal, Paco, Update, LSC, IMC WFS noise contribution in arm cavity length noise, Corrections ArmCavNoiseContributions.pdf
                      Reply  Wed May 12 10:53:20 2021, Anchal, Paco, Update, LSC, PSL-IMC PDH Loop and XARM PDH Loop diagram IMC_SingleArm.pdf
Entry  Mon May 10 10:57:54 2021, Anchal, Paco, Summary, Calibration, Using ALS beatnote for calibration, test BeatY_ITMY_CalibrationAt57Hz.pdfBeatY_ITMY_CalibrationAt43Hz.pdfBeatY_ITMY_CalibrationAt77Hz.pdf
Entry  Thu May 6 16:13:39 2021, Anchal, Summary, IMC, Angular actuation calibration for IMC mirrors IMC_Ang_Act_Cal_Kakeru_Tests.pdf
Entry  Wed May 5 13:05:07 2021, Chub, Update, General, chassis delivery from De Leone de_leone_del_5-5-21.jpg
Entry  Mon May 3 18:59:58 2021, Anchal, Summary, General, Weird gas leakagr kind of noise in 40m control room 40mNoiseFinal.mp3
    Reply  Mon May 3 23:28:56 2021, Koji, Summary, General, Weird gas leakagr kind of noise in 40m control room 
Entry  Mon Apr 19 09:17:51 2021, Jordan, Update, VAC, Empty N2 Tanks N2_Pressure.PNG
    Reply  Wed Apr 21 12:56:00 2021, Jordan, Update, VAC, Empty N2 Tanks Screenshot_2021-04-21_12-53-26.png
       Reply  Wed Apr 28 11:31:40 2021, Jon, Update, VAC, Empty N2 Tanks 
Entry  Mon Apr 26 18:52:52 2021, Anchal, Paco, HowTo, Computer Scripts / Programs, awg free slot 
Entry  Tue Apr 13 20:45:16 2021, Yehonathan, Update, PSL, Laser amplifier 20210413_204721.jpg20210413_203300.jpg20210413_204940.jpg20210413_205549.jpg
    Reply  Wed Apr 14 19:48:18 2021, gautam, Update, PSL, Laser amplifier 
       Reply  Thu Apr 15 09:46:24 2021, Yehonathan, Update, PSL, Laser amplifier 
          Reply  Fri Apr 16 18:21:36 2021, Yehonathan, Update, PSL, Laser amplifier 20210416_143642.jpg20210416_145408.jpg20210416_145448.jpg20210416_181324.jpg
             Reply  Sun Apr 18 21:29:55 2021, rana, Update, PSL, Laser amplifier 
                Reply  Wed Apr 21 11:09:57 2021, yehonathan, Update, PSL, Laser amplifier 20210420_171606.jpg20210420_171621.jpg20210420_171611.jpg20210420_171629.jpg20210420_171702.jpg
                   Reply  Thu Apr 22 17:28:34 2021, Yehonathan, Update, PSL, Laser amplifier 20210422_124940.jpgDrillRoomSchematics.pdf20210422_125240_1.png
Entry  Thu Apr 22 14:49:08 2021, gautam, Update, Computer Scripts / Programs, rossa added to RTS authorized keys 
Entry  Thu Apr 22 01:42:38 2021, Koji, Summary, Electronics, HV Supply Comparison HV_Supply_PSD_H.pdfHV_Supply_PSD_K.pdfHV_Supply_PSD_M.pdfHV_Supply_PSD.pdf
Entry  Wed Apr 21 05:48:47 2021, Chub, Update, General, PSL HEPA Maintenance 
    Reply  Wed Apr 21 13:10:12 2021, Koji, Update, General, PSL HEPA Maintenance 
Entry  Wed Apr 21 10:59:07 2021, rana, Summary, Cameras, note on new GigE cam @ 1064 
Entry  Wed Apr 21 00:08:15 2021, Koji, Update, PSL, PSL Table (sort of) covered / HEPA "chimney" 20210420235324_IMG_0560.jpeg20210420235304_IMG_0559.jpeg20210420235243_IMG_0558.jpeg20210420235344_IMG_0562.jpeg
    Reply  Wed Apr 21 01:14:03 2021, Koji, Update, PSL, PSL Table (sort of) covered / HEPA "chimney" P_20210421_005056.jpgP_20210421_005114.jpgP_20210421_005302.jpg
Entry  Fri Apr 16 00:21:52 2021, Koji, Update, General, Glue Freezer completely frozen P_20210416_000906.jpgP_20210416_000850.jpg
    Reply  Fri Apr 16 10:58:16 2021, Yehonathan, Update, General, Glue Freezer completely frozen 20210416_105048.jpg
       Reply  Fri Apr 16 19:07:31 2021, Yehonathan, Update, General, Glue Freezer completely frozen 
          Reply  Mon Apr 19 10:52:27 2021, Yehonathan, Update, General, Glue Freezer completely frozen 
             Reply  Mon Apr 19 19:40:54 2021, Yehonathan, Update, General, Glue Freezer completely frozen 
Entry  Fri Apr 16 11:31:00 2021, rana, Update, elog, elog stuck ~10 AM today 
Entry  Thu Apr 15 18:33:39 2021, Koji, Update, CDS, More 16bit ADC adapter boards P_20210415_183139_1.jpg
Entry  Wed Apr 7 22:48:48 2021, gautam, Update, IOO, Waveplate commissioning remotePowCtrl.pdf
    Reply  Tue Apr 13 17:47:07 2021, gautam, Update, IOO, Waveplate commissioning - software prepared remoteHWP.png
       Reply  Thu Apr 15 15:54:46 2021, gautam, Update, IOO, Waveplate commissioning - hardware installed 
Entry  Wed Apr 14 23:55:34 2021, gautam, Update, Electronics, HV Coil driver assembly 
Entry  Wed Apr 14 14:52:42 2021, gautam, Update, General, IFO State IFOSTATE.png
    Reply  Wed Apr 14 16:46:24 2021, Anchal, Update, General, IFO State 
Entry  Wed Apr 14 12:27:10 2021, gautam, Update, General, Lab left open again 
    Reply  Wed Apr 14 13:12:13 2021, Anchal, Update, General, Sorry, it was me 
       Reply  Wed Apr 14 15:30:29 2021, rana, Update, General, Sorry, it was me 
Entry  Wed Mar 17 09:05:01 2021, Paco, Anchal, Configuration, Computers, 40m Control Room Changes 
    Reply  Wed Apr 14 13:16:20 2021, Anchal, Configuration, Computers, 40m Control Room Changes 
Entry  Tue Apr 13 19:24:45 2021, gautam, Update, PSL, High power operations intensityDist.pdfclippingLoss.pdf
Entry  Mon Apr 12 08:32:54 2021, Anchal, Paco, Summary, PSL, PMC unlocked at 2pm on Sunday; ~ Restored 
    Reply  Mon Apr 12 18:34:26 2021, Yehonathan, Summary, PSL, PMC unlocked at 2pm on Sunday; ~ Restored 
Entry  Thu Apr 8 20:58:17 2021, Koji, Update, CDS, ADC adapter boards assembly P_20210408_205411_2_1.jpg
Entry  Wed Apr 7 13:07:03 2021, Jordan, Update, SUS, CoM on 3"->2" Adapter Ring for SOS CoM_with_Chamfer.pngMoments_of_Inertia.PNG
Entry  Wed Apr 7 02:50:49 2021, Koji, Update, SUS, Flange Inspections 
Entry  Thu Oct 15 20:00:23 2020, Koji, Summary, General, HEPA AC cord replacement P_20201015_200732.jpgP_20201015_200752.jpgP_20201015_202615.jpgP_20201015_204234.jpg
    Reply  Thu Apr 1 23:55:33 2021, Koji, Summary, General, HEPA AC cord replacement 
       Reply  Fri Apr 2 15:17:23 2021, gautam, Summary, General, HEPA AC cord replacement 
          Reply  Tue Apr 6 21:17:04 2021, Koji, Summary, General, PSL HEPA investigation 20210406211741_IMG_0554.jpeg20210406211840_IMG_0555.jpeg20210406211850_IMG_0556.jpeg
Entry  Mon Apr 5 22:26:01 2021, gautam, Update, LSC, PRMI 1f locking (no ETMs) recovered PRMI_Apr5sensMat_consolidated.pdf
Entry  Mon Apr 5 08:25:59 2021, Anchal, Paco, Update, General, Restore MC from early quakes 
Entry  Sat Apr 3 00:42:40 2021, gautam, Update, LSC, PRFPMI locking with half input power PRFPMIlock_1301464998_1301465238.pdfCARMplant.pdf
Entry  Fri Apr 2 01:26:41 2021, gautam, Update, Electronics, REFL55 chain checkout again, seems fine 
Entry  Wed Mar 31 00:40:32 2021, Koji, Update, Electronics, Electronics Packaging for assembly work P_20210330_233508.jpgP_20210330_233618.jpg
    Reply  Thu Apr 1 18:16:28 2021, Koji, Update, Electronics, Electronics Packaging for assembly work 
Entry  Thu Apr 1 00:50:06 2021, gautam, Update, SUS, PRMdiag 
Entry  Thu Feb 18 20:24:48 2021, Koji, Summary, Electronics, A bunch of electronics received IMG_0416.jpeg
    Reply  Sat Feb 20 10:01:48 2021, gautam, Summary, Electronics, A bunch of electronics received 
       Reply  Sat Feb 20 16:46:17 2021, Koji, Summary, Electronics, A bunch of electronics received 
    Reply  Fri Mar 5 00:53:09 2021, Koji, Summary, Electronics, A bunch of electronics received 
       Reply  Fri Mar 5 15:03:28 2021, gautam, Summary, Electronics, A bunch of electronics received 
          Reply  Fri Mar 5 15:32:53 2021, Koji, Summary, Electronics, A bunch of electronics received 
    Reply  Wed Mar 31 03:56:37 2021, Koji, Summary, Electronics, A bunch of electronics received P_20210331_013257.jpgP_20210331_014020.jpg
Entry  Wed Mar 24 15:24:13 2021, gautam, Update, LSC, Notes on tests 
    Reply  Wed Mar 24 22:54:49 2021, gautam, Update, LSC, New day, new problems PRMI3f_noArmssensMat.pdfREFL55_whtGainStepping.pngREFL55_whtGainStepping2.png
       Reply  Mon Mar 29 19:32:46 2021, gautam, Update, LSC, REFL55 whitening checkout REFL55wht.png
Entry  Thu Mar 25 18:05:04 2021, gautam, Update, Electronics, Stuffed HV coil drivers received from Screaming Circuits 
Entry  Thu Mar 25 17:39:28 2021, gautam, Update, Computer Scripts / Programs, Spot position measurement scripts "modernized" MCdecenter202103251735_mcmirror0.pdfMCdecenter202103251735_mcdecenter0.pdf
Entry  Fri Mar 12 03:08:23 2021, Koji, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM P_20210311_224651.jpgP_20210311_225359.jpg
    Reply  Fri Mar 12 12:32:54 2021, gautam, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM BS_actuator.pdfPRMact.pdf
       Reply  Fri Mar 12 13:01:43 2021, rana, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM 
          Reply  Fri Mar 12 13:48:53 2021, gautam, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM 
    Reply  Thu Mar 25 16:02:15 2021, gautam, Summary, SUS, Repeated measurement of coil Rs & Ls for PRM/BS 
Entry  Tue Mar 16 14:37:36 2021, Yehonathan, Update, BHD, SOS SmCo magnets Inspection 20210316_142906.jpg20210316_165626.jpg20210316_165838.jpg
    Reply  Wed Mar 17 14:40:39 2021, Yehonathan, Update, BHD, SOS SmCo magnets Inspection 
    Reply  Thu Mar 25 14:58:16 2021, Yehonathan, Update, BHD, SOS SmCo magnets Inspection 
Entry  Mon Mar 22 16:29:17 2021, gautam, Update, ASC, Some prep for AS WFS commissioning AS_WFS_head.pngWFSquads.pdf
Entry  Sun Mar 21 19:31:29 2021, rana, Summary, Electronics, RTL-SDR for monitoring RF noise / interference Screen_Shot_2021-03-21_at_7.43.24_PM.png
Entry  Thu Mar 18 21:37:59 2021, rana, Update, LSC, PRMI investigations: what IS the matrix?? PXL_20210319_045925024.jpg
    Reply  Fri Mar 19 11:18:25 2021, gautam, Update, LSC, PRMI investigations: what IS the matrix?? 
       Reply  Fri Mar 19 22:24:54 2021, gautam, Update, LSC, PRMI investigations: what IS the matrix?? IMG_9140.jpgIMG_9141.jpgREFL55.png
Entry  Fri Mar 19 15:31:56 2021, Aidan, Update, Computers, Activated MATLAB license on donatella 
Entry  Fri Mar 19 15:26:19 2021, Aidan, Update, Computers, Activated MATLAB license on megatron 
Entry  Thu Mar 18 18:06:36 2021, gautam, Update, Electronics, Modified Sat Amp and Coil Driver 
Entry  Wed Mar 17 15:02:06 2021, gautam, Update, safety, Door to outside from control room was unlocked 
    Reply  Thu Mar 18 12:35:29 2021, rana, Update, safety, Door to outside from control room was unlocked 
Entry  Tue Mar 16 16:02:33 2021, Koji, Update, LSC, REFL11 demod retrofitting IMG_0545.jpegIMG_0547.jpegD040179-A.pdfIMG_0548.jpegIMG_0550.jpeg
    Reply  Thu Mar 18 07:02:27 2021, Koji, Update, LSC, REFL11 demod retrofitting TFs.pdfPSD.pdf
Entry  Thu Mar 18 01:12:31 2021, gautam, Update, LSC, PRFPMi DARM_OLTF_20210317.pdfCARMTF_20210317.pdfPRFPMI_Mar_17sensMat.pdf
Entry  Wed Mar 17 15:04:20 2021, gautam, Update, Electronics, Ribbon cable for chassis IMG_9139.jpg
Entry  Wed Mar 17 10:52:48 2021, Jordan, Update, SUS, 3" Ring Adpater for SOS  Side_View.pngFront_View.pngRing_with_Modifed_Bracket.pngBack_of_ring.pngFront_of_Ring.png
Entry  Wed Mar 17 00:05:26 2021, gautam, Update, LSC, Delay line BIO remote control 
Entry  Mon Mar 15 08:55:45 2021, Paco, Anchal, Summary, training,  IMC_InputMatrixDiagonalization.pdfinputMatrixCalculationMC.tarfreeSwingMC.py.tarSUSfreeswing_1299514263.txt.tar
    Reply  Mon Mar 15 20:40:01 2021, rana, Configuration, Computers, installed QTgrace on donatella for dataviewer cutiegrace.png
Entry  Mon Mar 15 20:22:01 2021, gautam, Update, ASC, c1rfm model restarted RFM.pngCDSoverview.pngRFMchans.pngASCloops.png
Entry  Fri Mar 12 21:15:19 2021, gautam, Update, LSC, coronaversary PRFPMi PRFPMI.pngCARM_OLTF.pdf
Entry  Fri Mar 12 19:44:31 2021, gautam, Update, LSC, Delay line 
Entry  Fri Mar 12 18:10:01 2021, Anchal, Summary, Computer Scripts / Programs, Installed cds-workstation on allegra 
Entry  Fri Mar 12 11:44:53 2021, Paco, Anchal, Update, training, IMC SUS diagonalization in progress 
Entry  Thu Mar 11 14:27:56 2021, gautam, Update, CDS, timesync issue? timesync.pngc1lscMods.png
    Reply  Thu Mar 11 18:46:06 2021, gautam, Update, CDS, cds reboot CDSoverview.png
       Reply  Fri Mar 12 03:28:51 2021, Koji, Update, CDS, cds reboot 
          Reply  Fri Mar 12 11:02:38 2021, gautam, Update, CDS, cds reboot timeDrift.png
Entry  Fri Mar 12 03:23:37 2021, Koji, Update, BHD, DO card (DO-32L-PE) brought from WB P_20210311_232742.jpgP_20210311_232752.jpg
Entry  Fri Mar 12 03:22:45 2021, Koji, Update, General, Gaussmeter in the electronics drawer P_20210311_231104.jpg
Entry  Thu Mar 11 20:18:00 2021, gautam, Update, LSC, High bandwidth POY OLGevolution.pdfinLoopSpec.pdf
Entry  Thu Mar 11 14:03:02 2021, gautam, Update, LSC, AO path IMG_9127.HEIC
Entry  Thu Mar 11 02:10:06 2021, Koji, Summary, BHD, BHD Platform vertical dimentions BHD_Platform_Vertical_Dimentions.pdf
Entry  Wed Mar 10 00:32:03 2021, gautam, Update, LSC, PRFPMi PRMI3f_ALSsensMat.pdf
    Reply  Thu Mar 11 01:45:42 2021, gautam, Update, LSC, PRFPMi 
Entry  Wed Mar 10 19:58:27 2021, gautam, Update, LSC, SR785 hooked up to CM board 
Entry  Wed Mar 10 11:55:22 2021, gautam, Update, SUS, PRM suspension suspect PRM_sensorSpectra.pdfPRM_pkFitNaive.pdfPRM_diagComp.pdf
    Reply  Wed Mar 10 17:35:47 2021, gautam, Update, SUS, Spooky action at a distance PRMtrip.pngPRMtrip_zoom.png
Entry  Thu Feb 18 15:15:12 2021, yehonathan, Update, SUS, OSEM testing for SOSs OSEM_Pin_Plate.png
    Reply  Mon Feb 22 14:06:49 2021, Yehonathan, Update, SUS, OSEM testing for SOSs 
       Reply  Wed Feb 24 10:23:03 2021, Yehonathan, Update, SUS, OSEM testing for SOSs OSEM_078_LED_Spot.JPGOSEM_280_LED_Spot.JPGOSEM_117_LED_Spot.JPG
          Reply  Wed Mar 3 11:51:07 2021, Yehonathan, Update, SUS, OSEM testing for SOSs 
             Reply  Tue Mar 9 14:30:22 2021, Yehonathan, Update, SUS, OSEM testing for SOSs 
                Reply  Tue Mar 9 15:19:03 2021, Koji, Update, SUS, OSEM testing for SOSs 
                   Reply  Tue Mar 9 18:49:28 2021, Yehonathan, Update, SUS, OSEM testing for SOSs 
    Reply  Tue Feb 23 20:55:19 2021, Koji, Update, SUS, OSEM testing for SOSs SOS_OSEM.pdf
       Reply  Wed Feb 24 10:09:16 2021, yehonathan, Update, SUS, OSEM testing for SOSs 
Entry  Tue Mar 9 10:57:06 2021, Paco, Anchal, Summary, IMC, XARM lock and POX spectra 20210309_POX11_Spec_XARMLocked.pdf20210309_XARM_Locked.tar.gz
    Reply  Tue Mar 9 14:37:26 2021, gautam, Summary, SUS, PRM suspension PRMtrip.png
       Reply  Tue Mar 9 15:22:56 2021, Koji, Summary, SUS, PRM suspension 
Entry  Tue Mar 9 12:41:29 2021, Koji, Summary, Electronics, Investigation on the invacuum Dsub cables SOS_OSEM_cabling.pdf
Entry  Sun Mar 7 15:26:10 2021, gautam, Update, LSC, Housekeeping + more PRMI PRMI_SBres.pngMICH_act_calib.pdf
    Reply  Mon Mar 8 22:01:26 2021, gautam, Update, LSC, More PRMI PRMI1f_noArmssensMat.pdfPRMI3f_noArmssensMat.pdf
Entry  Mon Mar 8 20:11:51 2021, rana, Frogs, Computer Scripts / Programs, activate_matlab out of control on Megatron 
Entry  Mon Mar 8 17:09:29 2021, gautam, Update, SUS, PRM coil actuators heavily imbalanced PRMact.pdf
Entry  Mon Mar 8 12:54:54 2021, gautam, Update, Equipment loan, 40m-->Cryo 
Entry  Sat Mar 6 12:34:18 2021, gautam, Update, LSC, Sensing matrix settings messed with sensMat.png
    Reply  Sun Mar 7 19:56:27 2021, Anchal, Update, LSC, Sensing matrix settings messed with 
Entry  Tue Mar 2 19:52:46 2021, gautam, Update, LSC, REFL55 demod board rework 
    Reply  Wed Mar 3 22:13:05 2021, gautam, Update, LSC, REFL55 demod board rework 
       Reply  Thu Mar 4 23:16:08 2021, Koji, Update, LSC, REFL55 demod board rework D990511-00_REFL55.pdfP_20210304_215602.jpgP_20210304_222400.jpgP_20210304_222412.jpg20210304234400_IMG_0526.jpg
          Reply  Fri Mar 5 13:53:57 2021, gautam, Update, LSC, REFL55 demod board rework 
             Reply  Fri Mar 5 15:31:23 2021, Koji, Update, LSC, REFL55 demod board rework 
                Reply  Fri Mar 5 16:24:24 2021, gautam, Update, LSC, REFL55 demod board re-installed in 1Y2 REFL55.pdfdemodNoise.pdf
                   Reply  Fri Mar 5 22:25:13 2021, gautam, Update, LSC, PRMI 1f SB locking recovered PRMI1f_noArmssensMat.pdf
Entry  Thu Mar 4 23:57:35 2021, Koji, Summary, Electronics, Inspection of the new custom dsub cables 6x
Entry  Thu Mar 4 10:54:12 2021, Paco, Anchal, Summary, LSC, POY11 measurement, tried to lock Green Yend laser 20210304_POY11_Spectrum_YARMLocked.pdf20210304_POY11_Spectrum_YARMLocked.tar.gz
    Reply  Thu Mar 4 11:59:25 2021, Paco, Anchal, Summary, LSC, Watchdog tripped, Optics damped back 
       Reply  Thu Mar 4 15:48:26 2021, Koji, Summary, PEM, Watchdog tripped, Optics damped back 
Entry  Wed Mar 3 23:23:58 2021, gautam, Update, ALS, Arm cavity scan armScan.pdf
Entry  Wed Mar 3 12:00:58 2021, Paco, Anchal, HowTo, IMC, MC_F ASD 20210303_MC_F_Spectrum.pdf20210303_MC_F_Spectrum.tar.gz
Entry  Thu Nov 14 23:56:18 2019, rana, Update, LSC, off the bad Violin filters out.pdf
    Reply  Fri Nov 15 11:58:12 2019, gautam, Update, LSC, off the bad Violin filters violinFix.pdfnewViolinConfig.png
    Reply  Mon Mar 1 16:27:17 2021, gautam, Update, LSC, PRM violin filter excessive? violins.pdfPRviolin.pdf
       Reply  Tue Mar 2 13:39:31 2021, rana, Update, LSC, PRM violin filter excessive? 
Entry  Mon Mar 1 11:40:15 2021, Anchal, Paco, Summary, IMC, getting familiar with IMC controls 
    Reply  Mon Mar 1 12:36:38 2021, gautam, Summary, IMC, getting familiar with IMC controls 
Entry  Sun Feb 28 16:59:39 2021, rana, gautam, Update, LSC, more PRMI checks here: what it is ain't exactly clear RAMestimate.png
    Reply  Sun Feb 28 22:53:22 2021, gautam, Update, LSC, more PRMI checks here: what it is ain't exactly clear PRMI_SBres_REFL55.pngPRMI1f_noArmssensMat.pdfPRMI1f_noArmssensMat.pdfPRMI_locked.pngactTFs.pdf
Entry  Sat Feb 20 16:20:33 2021, gautam, Update, General, Housekeeping + PRMI char IPPOSdeat.pdfTTdrift.pdfPOXnPOY.pdfPRMI.pdf
    Reply  Sun Feb 21 20:51:21 2021, rana, Update, General, Housekeeping + PRMI char 
       Reply  Tue Feb 23 00:10:05 2021, gautam, Update, General, Demod char part 1 noPreamp.pdfwithPreamp.pdf
          Reply  Wed Feb 24 11:53:24 2021, gautam, Update, General, Demod char part 2 noises_noPreamp.pdfnoises_withPreamp.pdf
             Reply  Wed Feb 24 12:11:08 2021, gautam, Update, General, Demod char part 3 noPreamp.pdfwithPreamp.pdfnoPreamp_whitened.pdfwithPreamp_whitened.pdf
                Reply  Thu Feb 25 16:50:53 2021, gautam, Update, General, PRMI sensing matrix PRMI1f_noArmssensMat.pdf
                   Reply  Thu Feb 25 20:37:49 2021, gautam, Update, General, Setting modulation frequency and checking IMC offset modFreq.pdfIMC_offset.pdf
Entry  Wed Nov 4 17:14:49 2020, gautam, Update, CDS, c1bhd setup 
    Reply  Fri Nov 6 14:27:16 2020, gautam, Update, CDS, c1bhd setup - diskless boot Screenshot_2020-11-06_14-26-54.png
       Reply  Thu Feb 25 14:30:05 2021, gautam, Update, CDS, new c1bhd setup - diskless boot 
Entry  Wed Feb 24 12:29:18 2021, gautam, Update, General, Input pointing recovered 
Entry  Tue Feb 23 23:12:37 2021, Koji, Summary, SUS, SUS invacuum wiring SOS_OSEM_cabling.pdf
Entry  Mon Feb 22 14:53:47 2021, gautam, Update, CDS, dtt-ezca-tools installed on rossa 
Entry  Fri Feb 19 13:38:26 2021, gautam, Update, LSC, PRFPMI 
    Reply  Fri Feb 19 18:22:42 2021, rana, Update, LSC, PRFPMI sensiing matrix woes 
Entry  Fri Feb 19 15:17:51 2021, Jordan, Update, SUS, CoM Range on 3"->2" Adapter Ring for SOS Neutral_Point.pngDumbell_Max_Negative_Travel.pngDumbell_Max_Positive_Travel.png
    Reply  Fri Feb 19 16:06:01 2021, Koji, Update, SUS, CoM Range on 3"->2" Adapter Ring for SOS 
       Reply  Fri Feb 19 16:14:16 2021, gautam, Update, SUS, CoM Range on 3"->2" Adapter Ring for SOS 
          Reply  Fri Feb 19 16:55:26 2021, Koji, Update, SUS, CoM Range on 3"->2" Adapter Ring for SOS 
Entry  Tue Feb 16 14:56:44 2021, gautam, Update, SUS, aLIGO Sat Amp installed, powered MC1_deadUL.pngIMG_9100.jpg
    Reply  Wed Feb 17 16:11:53 2021, gautam, Update, SUS, aLIGO Sat Amp installed, powered 
       Reply  Thu Feb 18 15:33:21 2021, gautam, Update, SUS, aLIGO Sat Amp installed, powered and commissioned 
          Reply  Thu Feb 18 18:05:04 2021, gautam, Update, SUS, aLIGO Sat Amp characterization OSEMnoise.pdfLEDdriveNoise.pdf
             Reply  Thu Feb 18 20:20:25 2021, Koji, Update, SUS, aLIGO Sat Amp characterization 
Entry  Thu Feb 18 03:20:09 2021, Koji, Summary, Electronics, Current Rack Map rack_plan.pdf
Entry  Fri Feb 12 15:03:48 2021, Jordan, Update, SUS, CoM on 3"->2" Adapter Ring for SOS Screenshot_(1).pngScreenshot_(3).pngCoM.PNG
    Reply  Wed Feb 17 13:59:43 2021, Koji, Update, SUS, CoM on 3"->2" Adapter Ring for SOS 
Entry  Wed Feb 17 13:59:35 2021, gautam, Update, DetChar, Summary pages 
Entry  Thu Feb 11 18:21:39 2021, gautam, Update, SUS, MC suspension glitches 
Entry  Wed Jan 20 18:07:09 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements before modifications 7x
    Reply  Mon Jan 25 18:18:04 2021, Anchal, Summary, BHD, Satellite Amplifier Transfer Functions and noise D1002818_S2100029_TFandNoiseSpectrum.pdfD1002818_Testing.zip
       Reply  Wed Feb 3 16:27:19 2021, Anchal, Summary, BHD, Satellite Amplifier Transfer Functions and noise After modifications D1002818_S2100029_TFAfterChanges.pdfD1002818_S2100029_OutputNoiseSpecAfterChanges.pdfD1002818_S2100029_InputRefferedNoiseSpecAfterChanges.pdfD1002812_S2100029_After_Modifications_Feb3.jpgAfterChanges.zip
          Reply  Wed Feb 10 11:45:59 2021, Anchal, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications 6x
             Reply  Wed Feb 10 15:07:50 2021, Anchal, Summary, BHD, Satellite Amplifier Output Offset measurements 
                Reply  Wed Feb 10 15:25:45 2021, gautam, Summary, BHD, Satellite Amplifier Output Offset measurements 
                   Reply  Wed Feb 10 17:18:03 2021, Koji, Summary, BHD, Satellite Amplifier Output Offset measurements 
             Reply  Thu Feb 11 11:10:05 2021, Anchal, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications AfterChangesSpectrum_AC.zipD1002818_S2100029_OutputNoiseSpecAfterChanges.pdfD1002818_S2100029_InputRefCurrentNoiseSpecAfterChanges.pdfD1002818_S2100029_InputRefDispNoiseSpecAfterChanges.pdf
                Reply  Thu Feb 11 16:58:52 2021, rana, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications 
    Reply  Thu Jan 28 12:53:14 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements before modifications D1100117_S2100027_Current_Noise_Spectrum.pdfD1100117_S2100027_Voltage_Noise_Spectrum.pdfD1100117_S2100028_Current_Noise_Spectrum.pdfD1100117_S2100028_Voltage_Noise_Spectrum.pdfSpectrumMeasurement.zip
       Reply  Thu Jan 28 18:04:55 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications D1100117_S2100027_TF.pdfAfterChanges.zip
          Reply  Thu Jan 28 21:44:45 2021, gautam, Summary, BHD, HAM-A Coil Driver measurements After modifications 
             Reply  Fri Jan 29 15:39:30 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications TF and Noise S2100027 D1100687_S2100027_After_Modifications_Jan28.jpgD1100117_S2100027_TF.pdfD1100117_S2100027_Voltage_Noise_Spectrum.pdfD1100117_S2100027_Current_Noise_Spectrum.pdfAfterChanges.zip
                Reply  Tue Feb 2 11:57:46 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications TF and Noise S2100028 D1100687_S2100028_After_Modifications_Feb01_2021.jpgD1100117_S2100028_TF.pdfD1100117_S2100028_Voltage_Noise_Spectrum.pdfD1100117_S2100028_Current_Noise_Spectrum.pdfAfterChanges.zip
Entry  Wed Feb 10 14:14:58 2021, gautam, Update, Electronics, Custom cables received satWiring.pdf
Entry  Tue Feb 2 23:29:35 2021, Koji, Update, CDS, CDS crash and CDS/IFO recovery 
    Reply  Wed Feb 3 15:24:52 2021, gautam, Update, CDS, CDS crash and CDS/IFO recovery 
       Reply  Wed Feb 3 18:53:31 2021, Koji, Update, CDS, CDS crash and CDS/IFO recovery 
          Reply  Wed Feb 3 21:28:02 2021, gautam, Update, CDS, CDS crash and CDS/IFO recovery 
Entry  Tue Jan 12 08:21:47 2021, anchal, HowTo, CDS, Acromag wiring investigation SingleEndedNonFloatingWiring.pdfSingleEndedFloatingWiring.pdfDifferentialSignalWiring.pdf
    Reply  Tue Jan 12 11:42:38 2021, gautam, HowTo, CDS, Acromag wiring investigation 
       Reply  Wed Jan 13 16:09:29 2021, Anchal, HowTo, CDS, Acromag wiring investigation SimpleTestsStriptoolImages.pdf
          Reply  Tue Jan 26 12:59:51 2021, Anchal, HowTo, CDS, Acromag wiring investigation TestingDifferentialSignalWithFloatingRTNwrtIN-.pdf
             Reply  Tue Jan 26 15:37:25 2021, Anchal, HowTo, CDS, Acromag wiring investigation GeneralLabWiring.pdfGeneralLabWiring2.pdfGeneralLabWiring3.pdf
                Reply  Fri Jan 29 17:57:17 2021, Anchal, HowTo, CDS, Acromag wiring investigation GeneralLabWiringDiffWith2Wires.pdfGeneralLabWiringDiffWith3Wires.pdfDiffReadResistorbtwnINandRTN.pdf
Entry  Thu Jan 28 22:34:21 2021, gautam, Update, SUS, De-whitening DACnoiseModels.pdfactuationRange.pdfdeWhiteTFs.pdfdispNoiseModels.pdf
Entry  Tue Jan 26 10:58:30 2021, gautam, Update, SUS, MC2 tickler stuck on 
Entry  Wed Jan 20 19:12:16 2021, gautam, Update, CDS, SLwebview fixed 
Entry  Fri Dec 18 22:59:12 2020, Jon, Configuration, CDS, Updated CDS upgrade plan CDS_2020_Dec.pdfCDS_2020_Dec.graffle
    Reply  Mon Dec 21 09:28:50 2020, Jamie, Configuration, CDS, Updated CDS upgrade plan 
    Reply  Wed Dec 23 23:06:45 2020, gautam, Configuration, CDS, Updated CDS upgrade plan 
       Reply  Tue Jan 19 14:05:25 2021, Jon, Configuration, CDS, Updated CDS upgrade plan 40m_CDS_Network_-_Planned.pdf40m_CDS_Network_-_Current.pdf
          Reply  Tue Jan 19 15:43:24 2021, gautam, Configuration, CDS, Updated CDS upgrade plan 
Entry  Thu Jan 14 11:46:20 2021, gautam, Update, CDS, Expansion chassis from LHO 
    Reply  Thu Jan 14 12:19:43 2021, Jon, Update, CDS, Expansion chassis from LHO 
    Reply  Fri Jan 15 15:06:42 2021, Jon, Update, CDS, Expansion chassis from LHO 
       Reply  Fri Jan 15 16:54:57 2021, gautam, Update, CDS, Expansion chassis from LHO Screenshot_2021-01-15_17-00-06.png
          Reply  Tue Jan 19 13:19:24 2021, Jon, Update, CDS, Expansion chassis from LHO 
Entry  Wed Nov 18 22:49:06 2020, gautam, Update, ASC, Some thoughts about AS WFS electronics 
    Reply  Sun Nov 22 21:09:37 2020, gautam, Update, ASC, Planned mods for WFS head aLIGO_wfs_v5_40m.pdfTFs.pdfnoise.pdf
       Reply  Wed Nov 25 18:18:41 2020, gautam, Update, ASC, Planned mods for WFS head anodeVsOutput.pngsensitivity.png
          Reply  Sat Nov 28 21:44:53 2020, rana, Update, ASC, Planned mods for WFS head 
          Reply  Thu Dec 10 22:46:57 2020, gautam, Update, ASC, WFS head assembled aLIGO_wfs_v5_40m.pdfTF_meas.pdf
             Reply  Thu Dec 17 15:23:56 2020, gautam, Update, ASC, WFS head characterization oNoise.pdfZ_Hi.pdfZ_Low.pdfIMG_9030.jpgiNoise.pdf
    Reply  Wed Nov 25 18:30:23 2020, gautam, Update, ASC, Some thoughts about AS WFS electronics 
       Reply  Wed Dec 2 23:07:19 2020, gautam, Update, ASC, Electrical LO signal for AS WFS RF_Frequency_Source.pdf
          Reply  Thu Dec 3 11:02:35 2020, rana, Update, Electronics, Electrical LO signal for AS WFS 
          Reply  Thu Dec 3 13:55:52 2020, Koji, Update, ASC, Electrical LO signal for AS WFS 
             Reply  Thu Dec 3 20:38:46 2020, gautam, Update, ASC, Electrical LO signal for AS WFS RF_Frequency_Source.pdfdemodPath.pdfEOMpath.pdf
                Reply  Thu Dec 3 21:14:38 2020, Koji, Update, ASC, Electrical LO signal for AS WFS 
                   Reply  Thu Dec 3 21:44:49 2020, gautam, Update, ASC, Electrical LO signal for AS WFS 
                      Reply  Fri Dec 4 03:02:40 2020, Koji, Update, ASC, Electrical LO signal for AS WFS 
                         Reply  Fri Dec 4 22:41:56 2020, gautam, Update, ASC, Freq Gen Box revamp 
                            Reply  Sat Dec 5 20:44:35 2020, gautam, Update, ASC, Freq Gen Box re-installed 6x
                               Reply  Mon Dec 7 12:38:51 2020, gautam, Update, IOO, IMC loop char OLTFcomparison.pdfdemodMons.pdfOLTFcomparison.pdf
                               Reply  Mon Dec 7 22:54:30 2020, gautam, Update, LSC, Modulation depth measurement modDepth.pdf
                                  Reply  Sat Jan 16 18:59:44 2021, gautam, Update, LSC, Modulation depth measurement PLL.pdfmodDepth.pdfmodProfile.pdfEOMpath_postMod.pdf
Entry  Fri Jan 15 17:04:45 2021, gautam, Update, LSC, Messed up LSC sensing PRFPMI_Jan12sensMat.pdfPRMI3f_ALS_Jan11_largeOffsetsensMat.pdf
Entry  Thu Jan 14 12:32:28 2021, gautam, Update, CDS, Rogue master may be doing something good? Screenshot_2021-01-14_12-35-52.png
Entry  Thu Aug 6 00:34:38 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
    Reply  Fri Aug 7 11:23:47 2020, rana, Update, BHD, Monte Carlo Simulations 
       Reply  Mon Aug 10 07:13:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
          Reply  Tue Aug 25 05:51:29 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
             Reply  Mon Sep 14 07:50:01 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 10x
                Reply  Fri Oct 16 09:16:37 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
                   Reply  Thu Oct 22 11:48:08 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
                      Reply  Thu Dec 10 14:48:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations MCMCLance_NoiseBudget_Example.pdfIFO_Check.pdf
                         Reply  Fri Dec 11 09:28:52 2020, rana, Update, BHD, Monte Carlo loop coupling Simulations 
                            Reply  Mon Dec 14 11:09:28 2020, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations MCMC_LANCE_OLTFs.pdfMCMC_LANCE_OLCoupling2DARM.pdf
                               Reply  Mon Jan 11 16:11:51 2021, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations MC_LANCE_OLTFs.pdf
                                  Reply  Mon Jan 11 19:10:10 2021, rana, Update, BHD, Monte Carlo loop coupling Simulations 
Entry  Wed Jan 6 22:47:41 2021, gautam, Update, ALS, Noisy ALS ALSX_excess.pngbudget.pdf
    Reply  Thu Jan 7 19:16:11 2021, gautam, Update, ALS, Noisy ALS ALS_ERR_MON.pdfAUXnoise.pdf
       Reply  Thu Jan 7 20:07:27 2021, Koji, Update, ALS, Noisy ALS 
          Reply  Thu Jan 7 21:16:22 2021, gautam, Update, ALS, Noisy ALS 
             Reply  Thu Jan 7 23:25:19 2021, Koji, Update, ALS, Noisy ALS 
          Reply  Fri Jan 8 20:01:11 2021, gautam, Update, ALS, Noisy ALS ALSX_IR_green.pdf
Entry  Wed Jan 6 19:00:04 2021, gautam, Update, LSC, Phase loss in POX/POY loops POXloop.pdfloopFit.pdf
Entry  Wed Jan 6 16:18:38 2021, gautam, Update, Optical Levers, BS Oplev glitchy missingData.pngOLRIN.pdfBS_OL_P.pdfBS_OL_suppression.pdf
Entry  Wed Jan 6 15:28:04 2021, gautam, Update, VAC, Vac rack UPS batteries replaced 
Entry  Wed Dec 23 10:13:08 2020, gautam, Update, CDS, Near term upgrades IMG_0020.pdf
Entry  Mon Dec 21 18:18:03 2020, gautam, Update, CDS, Many model changes CDSoverview.png
    Reply  Tue Dec 22 22:11:37 2020, gautam, Update, CDS, AA filt repaired and reinstalled 
Entry  Sat Dec 19 20:24:25 2020, gautam, Update, Electronics, WFS hardware install 
Entry  Thu Dec 10 17:12:43 2020, Jon, Update, , New SMA cables on order 
    Reply  Sat Dec 19 00:25:20 2020, Jon, Update, , New SMA cables on order 
       Reply  Sat Dec 19 02:42:56 2020, Koji, Update, , New SMA cables on order 
Entry  Fri Dec 18 10:52:17 2020, gautam, Update, CDS, RFM errors  RFMdiag.png
Entry  Tue Dec 15 12:38:41 2020, gautam, Update, Electronics, DC power strip 
Entry  Thu Dec 10 22:45:42 2020, gautam, Update, SUS, More spare OSEMs 
Entry  Thu Dec 10 16:24:13 2020, gautam, Update, Equipment loan, Noliac PZT --> Paco 
Entry  Wed Dec 9 20:14:49 2020, gautam, Update, VAC, UPS failure rackBeforenAfter.pdfIMG_0008.jpgIMG_0009.jpgvacStatus.png
    Reply  Thu Dec 10 13:05:52 2020, Jon, Update, VAC, UPS failure TP2_time_history.pngslow_controls_monitors.png
       Reply  Thu Dec 10 14:29:26 2020, gautam, Update, VAC, UPS failure vacDiag1.png
Entry  Thu Dec 10 11:07:24 2020, Chub, Update, VAC, UPS fault 
    Reply  Thu Dec 10 11:17:50 2020, Chub, Update, VAC, UPS fault 
Entry  Wed Dec 9 15:37:48 2020, gautam, Update, CDS, RFM switch IP addr reset Screenshot_2020-12-09_15-39-20.pngScreenshot_2020-12-09_15-46-46.png
Entry  Wed Dec 9 12:02:04 2020, gautam, Update, LSC, POX locking still unsatisfactory armRIN.pdfPOX_OLTF.pdf
Entry  Wed Dec 9 11:54:11 2020, gautam, Update, Optical Levers, ITMX HeNe replaced OLtrend_old_ndscope.pngITMX_OL_P.pdfITMX_OL_Y.pdf
Entry  Tue Dec 8 15:07:13 2020, gautam, Update, Computer Scripts / Programs, ndscope updated test.pdf
Entry  Mon Dec 7 14:32:02 2020, gautam, Update, LSC, New demod phases for POX/POY locking POX_POY_OLTF.pdfPOX_POY_spectra.pdf
Entry  Fri Dec 4 19:23:40 2020, Koji, Update, Electronics, AA/AI board testing ongoing 
Entry  Tue Nov 10 12:41:23 2020, gautam, Update, IOO, 1W > IMC CD93A725-FB5C-4F67-BB2E-D122205114B0.jpeg
    Reply  Tue Nov 10 14:30:06 2020, gautam, Update, IOO, WFS2 broken  WFS2broken.pngWFS2broken_RF.png
       Reply  Fri Dec 4 15:58:22 2020, Koji, Update, IOO, WFS2 broken  
Entry  Wed Sep 16 12:03:07 2020, Jon, Update, VAC, Replacing pressure gauges vac_gauges.png
    Reply  Wed Dec 2 12:27:49 2020, Jon, Update, VAC, Replacing pressure gauges 
       Reply  Thu Dec 3 14:53:58 2020, Jon, Update, VAC, Replacing pressure gauges 
Entry  Thu Dec 3 10:46:39 2020, gautam, Update, Electronics, DC power strip requirements 
Entry  Thu Dec 3 10:33:00 2020, gautam, Update, VAC, TrippLite UPS delivered DFDD4F39-3F8A-439D-888D-7C0CE2E030CF.jpeg
Entry  Wed Dec 2 18:35:31 2020, gautam, Update, DetChar, Summary page revival 
Entry  Wed Dec 2 17:54:03 2020, gautam, Update, CDS, FE reboot 
Entry  Wed Dec 2 12:35:31 2020, Paco, Summary, Computer Scripts / Programs, TC200 python driver  
    Reply  Wed Dec 2 15:27:06 2020, gautam, Summary, Computer Scripts / Programs, TC200 python driver  
Entry  Tue Nov 24 16:51:29 2020, gautam, Update, PonderSqueeze, Ponderomotive squeezing in aLIGO QN_heatmap_RSE.pdfQN_heatmap_SR.pdfnoiseBudget.pdf
Entry  Mon Nov 23 23:27:43 2020, Koji, Summary, ASC, Q3000 characterization 
Entry  Wed Nov 18 17:51:50 2020, gautam, Update, VAC, Agilent pressure gauge controller delivered 
    Reply  Mon Nov 23 16:33:10 2020, gautam, Update, VAC, More vacuum deliveries  
Entry  Mon Nov 23 12:25:14 2020, gautam, Update, BHD, BHD MMT Optics delivered IMG_8965.HEIC
    Reply  Mon Nov 23 14:52:10 2020, Koji, Update, BHD, BHD MMT Optics delivered 
Entry  Tue Nov 17 13:24:40 2020, Chub, Update, General, big UPS on the way 
Entry  Thu Nov 12 14:31:27 2020, gautam, Update, Electronics, SR560s in need of repair/battery replacement IMG_8947.jpg
    Reply  Tue Nov 17 00:26:32 2020, rana, Update, Electronics, SR560s in need of repair/battery replacement 
Entry  Mon Nov 16 16:00:19 2020, gautam, Update, Equipment loan, LB1005-->Cryo lab 
Entry  Wed Nov 4 00:10:43 2020, gautam, Update, General, Vent activities today IMG_0184.jpgIMG_0185.jpgIMG_0187.jpgIMG_0207.jpegIMG_0210.jpg
    Reply  Thu Nov 5 22:27:34 2020, gautam, Update, General, Vent activities today 
       Reply  Fri Nov 6 11:36:37 2020, gautam, Update, General, ETMY suspension eigenmodes ETMY_pkFitNaive.pdfETMY.tar.bz2
          Reply  Tue Nov 10 15:13:41 2020, rana, Update, General, ETMY suspension eigenmodes 
             Reply  Thu Nov 12 14:26:35 2020, gautam, Update, General, ETMY suspension eigenmodes ETMY.tar.bz2
       Reply  Sun Nov 8 20:22:35 2020, gautam, Update, General, Vent activities today IFOalignment.png
          Reply  Sun Nov 8 23:24:29 2020, Koji, Update, General, Vent activities today 
          Reply  Mon Nov 9 17:40:17 2020, gautam, Update, General, Pumpdown IMG_8937.jpgpumpdown.png
             Reply  Tue Nov 10 11:31:13 2020, Koji, Update, General, Pumpdown Screen_Shot_2020-11-10_at_11.30.21.png
Entry  Tue Nov 10 17:46:06 2020, gautam, Update, General, IFO recovery RFMerrs.pngIFOrecovery.pngALS_ool.pdfPRMIcarr.png
Entry  Tue Nov 10 11:59:37 2020, gautam, Update, VAC, Stuck RV2 damagedThread.001.jpegIFOstatus.pngP1a_leakTest.png
Entry  Fri Nov 6 14:08:44 2020, gautam, Update, PSL, PMC re-locked 
Entry  Tue Nov 3 09:06:50 2020, gautam, Update, General, Lab alarm tripped 
Entry  Wed Oct 28 20:42:53 2020, Koji, Update, General, Vent Prep 10x
    Reply  Thu Oct 29 12:43:35 2020, gautam, Update, General, Vent Prep preVentAlignment.pngPRMIcarr_PRMalignment.pngALS_ool.pdflowPowerMC.png
       Reply  Thu Oct 29 19:30:56 2020, gautam, Update, General, Vent complete ventValveStatus.pngvent_Oct2020.jpgventValveStatus_overnight.pnglowPowerIMC_afterVent.png
          Reply  Mon Nov 2 12:44:25 2020, gautam, Update, General, ETMY and OMC chamber heavy doors off CB84FD62-C48B-414F-8825-50C9DE0B47CF.jpeg
             Reply  Mon Nov 2 16:46:06 2020, gautam, Update, General, Plan for OMC chamber IMG_2318.JPGIMG_2332.JPG
                Reply  Mon Nov 2 17:13:19 2020, Koji, Update, General, Plan for OMC chamber 
                   Reply  Mon Nov 2 17:32:05 2020, gautam, Update, General, Plan for OMC chamber IMG_2317.JPG
Entry  Thu Oct 29 09:50:12 2020, anchal, Summary, Calibration, Preliminary calibration measurement taken PreliminaryCalibrationData.pdf
Entry  Tue Oct 27 23:47:53 2020, gautam, Update, General, ISS checkout 
    Reply  Wed Oct 28 14:01:03 2020, not gautam, Update, General, ISS checkout 
       Reply  Wed Oct 28 14:07:47 2020, gautam, Update, General, ISS checkout 
Entry  Sat Oct 3 16:51:27 2020, gautam, Update, CDS, RFM errors RFMstat.pngRFMerrs.png
    Reply  Wed Oct 28 09:35:00 2020, Koji, Update, CDS, RFM errors Screen_Shot_2020-10-28_at_10.06.00.png
Entry  Fri Oct 23 16:41:06 2020, Koji, Update, IOO, Excess laser freq noise investigation plot.pdf
    Reply  Mon Oct 26 13:35:58 2020, Koji, Update, IOO, Excess laser freq noise investigation 6x
       Reply  Mon Oct 26 17:26:26 2020, gautam, Update, IOO, Excess laser freq noise investigation 
Entry  Fri Oct 23 19:01:57 2020, Koji, Summary, PEM, PSL Particle Counter kit removed from the table P_20201022_173529.jpgP_20201022_173419.jpg
Entry  Tue Oct 20 20:12:18 2020, Koji, Summary, General, DJI OSMO Pocket Camera Kit 20201020200929_IMG_0173.JPG
Entry  Mon Oct 19 15:40:02 2020, Koji, Update, PEM, Alaska EQ M7.5 
Entry  Mon Oct 19 15:38:42 2020, Koji, Update, Electronics, Loan: A file binder "40m wiring diagram"  
Entry  Thu Oct 15 13:48:58 2020, anchal, Summary, General, Lab Entry Notification 
    Reply  Fri Oct 16 19:44:41 2020, anchal, Summary, General, Lab Entry Notification 
Entry  Tue Oct 13 11:13:54 2020, gautam, Update, BHD, Investigation into RF44 sensing phaseNoisePSD.pdfloopTF.pdf
    Reply  Thu Oct 15 10:42:39 2020, gautam, Update, BHD, More investigation into RF44 sensing analogZetaLock.pngrelPhaseNoise.pdfsigMagPhase.pdf
Entry  Wed Oct 14 18:16:27 2020, gautam, Update, General, PSL HEPA-->50% 
Entry  Sat Sep 19 23:59:22 2020, anchal, Summary, ALS, ALS noise budget update ALS_nb_ExtraPoles.pdfALS_controls.yamlALS_nb_Kiwamus_Values.pdfALS_controls_Kiwamus_Values.yamlALS_simulink_model.svg
    Reply  Sun Sep 20 23:12:13 2020, rana, Summary, ALS, ALS noise budget update 
       Reply  Tue Sep 22 00:14:43 2020, anchal, Summary, ALS, ALS noise budget update ALS_NoiseBudgetUpdate.pdfALS_controls.yaml
          Reply  Tue Sep 22 12:14:42 2020, rana, Summary, ALS, ALS noise budget update 
             Reply  Wed Sep 23 11:13:49 2020, anchal, Summary, ALS, ALS noise budget update ALS_NoiseBudgetUpdate.pdfALS_controls.yaml
                Reply  Wed Oct 7 16:56:23 2020, anchal, Summary, ALS, ALS noise budget update - Updated AUX PDH Loop values Extract_X_AUX_PDH_Model.zipALS_NoiseBudgetUpdate.pdf
                   Reply  Thu Oct 8 11:59:52 2020, rana, Summary, ALS, ALS noise budget update - Updated AUX PDH Loop values 
                      Reply  Fri Oct 9 18:32:14 2020, anchal, Summary, ALS, ALS noise budget update - Updated AUX PDH Loop values 
                         Reply  Wed Oct 14 17:03:55 2020, anchal, Summary, ALS, ALS noise budget update - Added whitening filter for ADC ALS_NoiseBudgetUpdate.pdf
Entry  Wed Oct 14 13:28:04 2020, Koji, Update, COC, ITM/ETM spares in Downs IMG_3073.jpeg
Entry  Tue Oct 13 21:22:29 2020, gautam, Update, General, Space cleared in 1Y1 for new FEs 
Entry  Thu Oct 8 08:37:15 2020, gautam, Update, Computer Scripts / Programs, Finesse GUI 
    Reply  Thu Oct 8 18:40:42 2020, Koji, Update, Computer Scripts / Programs, Finesse GUI 
Entry  Thu Oct 8 15:08:25 2020, gautam, Update, General, Some boxes moved from 40m entry hallway 
Entry  Wed Oct 7 13:06:27 2020, Koji, Update, General, Presence in the lab 
Entry  Tue Oct 6 14:35:16 2020, Jordan, Update, VAC, Spare forepumps 
Entry  Tue Oct 6 07:37:20 2020, yehonathan, Update, Wiki, New TIS measurements of 40m Optics ITMU_sn01-02_tis_1.pdf
Entry  Mon Oct 5 14:01:41 2020, gautam, Update, Electronics, aLIGO demod boards stuffed and delivered IMG_8888.JPG
Entry  Mon Oct 5 00:37:19 2020, gautam, Update, BHD, Single bounce interferometer locked simpleHomodyne.pngsingleBounceIFO.pdfproposedController.pdffreeRunningSuppressed.pdf
    Reply  Mon Oct 5 00:53:16 2020, Koji, Update, BHD, Single bounce interferometer locked 
Entry  Sun Oct 4 15:32:21 2020, gautam, Update, SUS, Suspension health check combined.pdfallPlots.zip
Entry  Fri Oct 2 12:52:22 2020, gautam, Update, General, Spectroscopic grade Isopropanol delivered 
Entry  Fri Oct 2 10:29:49 2020, gautam, Update, Optical Levers, ETMY, BS and ITMX HeNes degrading OLsum.png
Entry  Thu Oct 1 17:44:48 2020, gautam, Update, General, Some inventory notes 
Entry  Tue Sep 22 23:16:54 2020, Koji, Update, General, HEPA Inspection 11x
    Reply  Tue Sep 22 23:17:51 2020, Koji, Update, General, HEPA Inspection 6x
       Reply  Wed Sep 30 17:12:24 2020, gautam, Update, General, HEPA blower startup capacitor replacement 
          Reply  Wed Sep 30 19:45:56 2020, rana, Update, General, HEPA blower startup capacitor replacement 
Entry  Tue Sep 29 17:07:25 2020, gautam, Update, General, Lab visit for inventory location 
Entry  Wed Sep 23 15:06:54 2020, Jordan, Update, VAC, TP2 Forepump Re-install Screenshot_from_2020-09-23_15-15-43.pngMainVolPumpDown.png
Entry  Wed Sep 23 08:57:18 2020, gautam, Update, VAC, TP2 running HOT Screen_Shot_2020-09-23_at_8.55.39_AM.png
    Reply  Wed Sep 23 10:06:52 2020, Koji, Update, VAC, TP2 running HOT Screen_Shot_2020-09-23_at_10.00.43.png
Entry  Fri Sep 18 10:47:48 2020, gautam, Update, BHD, Sensing scheme for homodyne phase fieldQuads.pdfPMAMratio.pdf
    Reply  Tue Sep 22 22:38:11 2020, gautam, Update, BHD, Sensing scheme for homodyne phase - some analytic calcs simpleMich.pdf.zip
Entry  Tue Sep 22 16:29:30 2020, Koji, Update, General, Control Room AC setting for continuous running P_20200922_161125.jpg
Entry  Mon Sep 21 16:40:52 2020, gautam, Update, PSL, HEPAs are no longer running 
Entry  Mon Sep 21 15:57:08 2020, Jordan, Update, VAC, TP3 Forepump Replacement and Vac reset Screenshot_from_2020-09-21_15-56-04.png20200921_145043.jpg20200921_145040.jpg
Entry  Sat Sep 19 01:49:52 2020, Koji, Update, General, M4.5 EQ in LA 
    Reply  Sat Sep 19 11:27:04 2020, rana, Update, General, M4.5 EQ in LA Sep18-EQ.pdf
       Reply  Sat Sep 19 18:08:34 2020, rana, Update, General, M4.5 EQ in LA 
    Reply  Sat Sep 19 19:14:59 2020, Koji, Update, General, ITMX released / ETMY UR magnet knocked off IMG_6218.jpeg
       Reply  Sun Sep 20 11:41:54 2020, gautam, Update, General, IMC re-locked 
       Reply  Mon Sep 21 12:40:58 2020, gautam, Update, General, Workable IFO recovery IFOrecovery.pngIMG_5345.JPG
Entry  Sat Sep 19 18:07:35 2020, Koji, Update, VAC, TP3 RP failure vac.pngScreen_Shot_2020-09-19_at_17.52.40.png
    Reply  Sat Sep 19 19:37:16 2020, not Koji, Update, VAC, TP3 RP failure 
Entry  Sat Sep 19 18:46:48 2020, Koji, Update, General, Hand soap 
Entry  Wed Sep 16 17:44:27 2020, gautam, Update, CDS, All vertex FE models restarted CDS.png
Entry  Tue Sep 15 17:19:09 2020, gautam, Update, IOO, MC F spectrum  MCF_MCL.pdf
    Reply  Tue Sep 15 19:17:30 2020, rana, Update, IOO, MC F spectrum  
       Reply  Wed Sep 16 09:43:41 2020, gautam, Update, IOO, MC F spectrum  MCF_MCL.pdf
Entry  Mon Sep 7 23:49:14 2020, gautam, Update, BHD, A first look at RF44 scheme 
    Reply  Tue Sep 8 01:31:43 2020, Koji, Update, BHD, A first look at RF44 scheme 
    Reply  Wed Sep 9 00:05:18 2020, gautam, Update, BHD, More notes on the RF44 scheme IMG_3397.JPGphaseNoisePSD.pdfmagnitudeHist.pdfLOpowerDrift.png
       Reply  Tue Sep 15 22:11:52 2020, gautam, Update, BHD, More notes on the RF44 scheme RF44.pdf
Entry  Fri Jun 26 16:53:38 2020, gautam, Update, Electronics, RFPD characterization WFS1.pdfWFS2.pdfbuildupMons.pdf
    Reply  Mon Jun 29 15:56:02 2020, gautam, Update, Electronics, RFPD characterization 
    Reply  Sun Jul 5 18:25:42 2020, rana, Update, Electronics, WFS characterization WFS_attenOff.pdf
       Reply  Sun Jul 12 22:40:35 2020, gautam, Update, Electronics, WFS characterization - old SURF report 
       Reply  Sat Aug 29 20:07:48 2020, rana, Update, Electronics, WFS characterization 
          Reply  Sat Aug 29 22:10:09 2020, gautam, Update, Electronics, WFS characterization 
          Reply  Tue Sep 15 17:04:43 2020, gautam, Update, Electronics, DC adaptors delivered 
Entry  Wed Aug 12 18:08:54 2020, gautam, Update, Electronics, Number of the beast IMG_8710.JPG
    Reply  Wed Aug 12 20:15:42 2020, Koji, Update, Electronics, Number of the beast 
    Reply  Tue Sep 15 12:20:36 2020, gautam, Update, Electronics, SR785 repaired dividerTF.pdf
Entry  Tue Sep 15 10:57:30 2020, gautam, Update, PSL, PMC re-locked, RGA re-enabled RGAscan.pdf
Entry  Thu Sep 10 15:56:08 2020, Koji, Update, General, HEPA & Particle Level Status 
Entry  Thu Sep 10 15:43:22 2020, Jon, Update, BHD, Input noise spectra for A+ BHD modeling 
Entry  Wed Sep 9 20:52:45 2020, rana, Summary, IOO, wandering line in IMC 
Entry  Tue Aug 6 14:55:23 2019, gautam, Update, CDS, Making Matlab R2015b the default ML2015b.png
    Reply  Mon Sep 30 17:04:30 2019, gautam, Update, CDS, Some path changes 
       Reply  Tue Sep 8 11:49:04 2020, gautam, Update, CDS, Some path changes 
Entry  Sun Sep 6 13:15:44 2020, Jon, Update, DAQ, UPS for framebuilder 
Entry  Sat Sep 5 14:28:03 2020, Koji, Update, General, LO beam: Fiber coupling work 20200905212254_IMG_9938.JPG
Entry  Fri Sep 4 15:26:55 2020, Jon, Update, VAC, Vac system UPS installation 
    Reply  Fri Sep 4 21:12:51 2020, Jon, Update, VAC, Vac system UPS installation 
       Reply  Sat Sep 5 12:01:10 2020, Jon, Update, VAC, Vac system UPS installation vac_medm.pngvac_medm.png
Entry  Fri Aug 28 23:33:38 2020, gautam, Update, BHD, Some more hardware changes 
    Reply  Sat Aug 29 22:46:29 2020, gautam, Update, BHD, New homodyne-phase control electronics zetaDrive.pdftrekTFs.pdf
       Reply  Wed Sep 2 00:49:47 2020, gautam, Update, BHD, Some notes about homodyne phase heterodyneMICH.pdfunwrappedPhase.pdfunwrappedPhase_zoom.pdfphaseNoisePSD.pdf
          Reply  Thu Sep 3 15:55:04 2020, gautam, Update, BHD, Phase drift between LO and IFO after fiber replacement LOphaseDrift.pdfphaseDrift_tempCorr.png
Entry  Thu Sep 3 00:00:57 2020, gautam, Update, BHD, New patch cable installed 
Entry  Tue Sep 1 01:49:49 2020, Koji, Update, Electronics, Teledyne AP1053 etc were transported 20200831203756_IMG_9931.jpg20200831203826_IMG_9932.jpg20200831205126_IMG_9934.jpg
Entry  Sun Aug 30 11:29:33 2020, rana, Update, General, power blink? 
Entry  Sat Aug 29 18:52:42 2020, rana, Update, IOO, IMC gain change 
Entry  Fri Aug 28 11:41:23 2020, gautam, Bureaucracy, safety, Crane inspection 2020 
Entry  Wed Aug 26 22:49:47 2020, gautam, Update, Electronics, Checkout of Trek Model 603 IMG_8951.JPG
Entry  Wed Aug 26 15:48:31 2020, gautam, Update, VAC, Control screen left open on vacuum workstation 
Entry  Mon Aug 10 16:52:04 2020, gautam, Update, BHD, Workable setup prepared 
    Reply  Tue Aug 11 23:20:29 2020, gautam, Update, BHD, Some first tests with air BHD setup PRMI_RFlock.pdfPRMI_RFlock_fullscale.pdf
       Reply  Fri Aug 21 15:27:00 2020, gautam, Update, BHD, Better BHD mode-matching IMG_7548.JPGBHD_MM.pngPRMI_DCPDs.pdf
          Reply  Wed Aug 26 00:52:55 2020, gautam, Update, BHD, BHD activities 
Entry  Mon Aug 24 08:13:56 2020, Jon, Update, VAC, UPS installation 
    Reply  Mon Aug 24 11:25:07 2020, Jon, Update, VAC, UPS installation 
Entry  Mon Aug 17 23:36:10 2020, gautam, Update, ALS, Whitening and ALS noise ALSimprovement.pdf
    Reply  Tue Aug 18 13:55:23 2020, rana, Update, ALS, Whitening and ALS noise 
Entry  Mon Aug 17 23:41:50 2020, gautam, Update, BHD, Whitening and air BHD dark noise BHD_whitening.pdf
Entry  Mon Aug 17 21:24:43 2020, gautam, Update, General, Fire extinguisher inspection 
Entry  Mon Aug 17 15:18:26 2020, gautam, Update, Equipment loan, Beam Profiler + peripherals --> 40m IMG_8719.JPG
Entry  Fri Aug 14 10:10:56 2020, Jon, Configuration, VAC, Vacuum repairs today 
    Reply  Sat Aug 15 02:02:13 2020, Jon, Configuration, VAC, Vacuum repairs today 
       Reply  Sat Aug 15 15:12:22 2020, Jon, Configuration, VAC, Overhaul of small turbo pump interlocks small_tp_signal_routing.pngsmall_tp_interlock_signal.pngsmall_tp_signal_routing.pngmedm_screen.png
Entry  Wed Aug 12 17:36:42 2020, gautam, Update, CDS, Timing distribution slot availability IMG_8706.JPG
    Reply  Wed Aug 12 20:14:06 2020, Koji, Update, CDS, Timing distribution slot availability 
       Reply  Thu Aug 13 11:30:19 2020, gautam, Update, CDS, Timing distribution slot availability 
          Reply  Thu Aug 13 13:35:13 2020, Koji, Update, CDS, Timing distribution slot availability 
             Reply  Fri Aug 14 10:03:37 2020, Jon, Update, CDS, Timing distribution slot availability 
Entry  Fri Aug 14 00:01:55 2020, gautam, Update, CDS, BHD / OMC model channels now added to autoburt 
Entry  Thu Aug 13 18:10:22 2020, gautam, Update, General, Power outage 
Entry  Wed Aug 12 17:42:58 2020, gautam, Update, Electronics, Photodiode inventory IMG_8709.JPGIMG_8708.JPG
    Reply  Wed Aug 12 20:16:52 2020, Koji, Update, Electronics, Photodiode inventory 
Entry  Sat Aug 8 07:36:52 2020, Sanika Khadkikar, Configuration, Calibration-Repair, BS Seismometer - Multi-channel calibration BS_X-EY_X.pngBS_Y-EY_Y.pngBS_Z-EY_Z.pngtimeseries.png
Entry  Thu Aug 6 22:57:20 2020, gautam, Update, safety, New live HV Supplies 
Entry  Thu Jul 30 16:16:43 2020, gautam, Update, SUS, Suspension recovery 
Entry  Thu Jul 9 17:12:52 2020, gautam, Update, BHD, In-air BHD OMCchamber.pdfAP_Table_20180328.pdf
    Reply  Tue Jul 14 15:29:25 2020, gautam, Update, BHD, In-air BHD - DCPD amplifier noise DCPDamp.pdf
    Reply  Wed Jul 15 19:11:40 2020, gautam, Update, BHD, In-air BHD - alignment into OMC 
       Reply  Thu Jul 16 01:12:22 2020, gautam, Update, BHD, In-air BHD - preparing the LO path IMG_8626.JPGIMG_8627.JPGIMG_8628.JPGIMG_8629.JPG
          Reply  Sun Jul 19 15:40:15 2020, gautam, Update, BHD, In-air BHD - CDS and wiring summary wiringDiagram.pdf
             Reply  Wed Jul 29 11:57:59 2020, rana, Update, BHD, In-air BHD - CDS and wiring summary 
          Reply  Mon Jul 20 17:55:15 2020, gautam, Update, BHD, In-air BHD - preparing the LO path 
             Reply  Tue Jul 21 00:30:24 2020, gautam, Update, BHD, In-air BHD - LO RIN LO_RIN.pdf
Entry  Tue Jul 28 12:22:40 2020, Jon, Update, VAC, Vac interlock test today 1:30 pm 
    Reply  Tue Jul 28 14:11:14 2020, Jon, Update, VAC, Vac interlock test today 1:30 pm 
Entry  Tue Jul 28 13:55:11 2020, Hang, Update, BHD, Exploring bilinear SRCL->DARM coupling SRCL_bilin_DHARD.pdfARM_RIN.pdfSRCL_bilin_SRCL.pdf
Entry  Thu Jul 23 15:58:24 2020, Jon, Summary, VAC, Vacuum controls refurbishment plan 
    Reply  Mon Jul 27 15:48:36 2020, Jon, Summary, VAC, Vacuum parts ordered 
Entry  Fri Jul 24 15:40:59 2020, Jordan, Update, VAC, Installation of two new UPS units UPS.jpg
Entry  Tue Jul 21 16:41:46 2020, gautam, Update, BHD, PMC assembly space  IMG_8635.JPG
Entry  Mon Jul 20 19:21:16 2020, anchal, Summary, ALS, Few proposals for Voyager ALS VoyagerALSSchemes.pdf
Entry  Tue Jul 14 16:52:47 2020, gautam, Update, Electronics, Coil drivers for the test masses coilDriverSchem.pdf
    Reply  Wed Jul 15 21:08:43 2020, gautam, Update, Electronics, ETM coil outputs DQed CDS.pngcoilOutDQed.png
    Reply  Mon Jul 20 17:23:46 2020, gautam, Update, Electronics, Coil drivers for the test masses ALSlock_timeDomain.pdfALSlock.pdfRFlock.pdf
Entry  Fri Jul 17 09:03:58 2020, Jordan, Update, General, Presence at 40m 
Entry  Fri Jul 17 00:18:13 2020, gautam, Update, General, Locking updat 
Entry  Thu Jul 16 14:41:22 2020, gautam, Update, General, Fire extinguisher inspection 
Entry  Wed Jul 15 19:23:44 2020, gautam, Update, General, Emergency light on in control room 
    Reply  Wed Jul 15 19:51:51 2020, Koji, Update, General, Emergency light on in control room 
       Reply  Wed Jul 15 20:58:40 2020, gautam, Update, General, Emergency light on in control room 
Entry  Wed Jul 15 17:46:05 2020, anchal, Summary, ALS, Noise budget for ALS  ALS_nb.pdf
Entry  Tue Jul 14 00:06:09 2020, gautam, Update, LSC, Locking with POX for CARM 
    Reply  Tue Jul 14 01:55:03 2020, Koji, Update, LSC, Locking with POX for CARM 
    Reply  Tue Jul 14 17:28:29 2020, gautam, Update, LSC, Locking with POX for CARM PRFPMI_2020712sensMat.pdfLSCerrSigs.pdf
Entry  Tue Jul 14 09:04:53 2020, Jordan, Update, General, Presence at 40m 
Entry  Fri Sep 6 16:38:24 2019, aaron, Update, ALARM, Alarm noise from smart-ups machine under workstation? 
    Reply  Fri Sep 6 18:08:29 2019, rana, Update, Computers, Alarm noise from smart-ups machine under workstation? 
       Reply  Thu Sep 12 09:49:07 2019, gautam, Update, Computers, control rm wkstns shutdown IMG_7943.JPG
          Reply  Mon Sep 30 11:42:36 2019, aaron, Update, Computers, control rm wkstns shutdown 
             Reply  Wed Oct 2 20:45:18 2019, rana, Update, Computers, rossa revival 
                Reply  Thu Oct 3 21:50:22 2019, rana, Update, Computers, rossa revival 
                Reply  Mon Oct 28 18:55:06 2019, rana, Update, Computers, rossa revival 
                   Reply  Wed Jan 22 16:38:01 2020, rana, Update, Computers, rossa revival 
                      Reply  Wed Jul 1 18:16:09 2020, gautam, Update, Computers, rossa re-re-revival MCacc.pdf
                         Reply  Sun Jul 5 16:14:41 2020, rana, Update, Computers, rossa re-re-revival 
                         Reply  Sun Jul 5 18:39:57 2020, rana, Update, Computers, rossa: printer 
                            Reply  Mon Jul 6 00:37:28 2020, gautam, Update, Computers, rossa: lib symlink 
                               Reply  Mon Jul 6 12:43:02 2020, rana, Update, Computers, rossa: lib symlink 
                                  Reply  Mon Jul 6 12:51:41 2020, gautam, Update, Computers, rossa: resolvconf installed 
                                     Reply  Wed Jul 8 22:50:33 2020, gautam, Update, Computers, rossa: more symlinks 
                                  Reply  Thu Jul 9 16:16:20 2020, gautam, Update, Computers, rossa: graphics driver issues? 
                                     Reply  Sat Jul 11 00:10:22 2020, gautam, Update, Computers, rossa: more developmental work 
                                        Reply  Mon Jul 13 11:33:18 2020, rana, Update, Computers, rossa: more developmental work 
                                           Reply  Mon Jul 13 12:37:05 2020, gautam, Update, Computers, rossa: more developmental work 
Entry  Fri Jul 10 01:25:28 2020, gautam, Update, LSC, Locking notes 
    Reply  Fri Jul 10 15:26:28 2020, gautam, Update, LSC, MC2 coils need DC balancing? MC2_balancing.pngASDC.png
       Reply  Sat Jul 11 18:24:30 2020, Koji, Update, LSC, MC2 coils need DC balancing? 
       Reply  Sun Jul 12 02:42:01 2020, gautam, Update, LSC, Locking (on rossa) ASCsteps.png
       Reply  Mon Jul 13 11:36:08 2020, rana, Update, LSC, MC2 coils need DC balancing? 
Entry  Fri Jul 10 10:37:30 2020, Jordan, Update, General, Presence at 40m 
Entry  Wed Jul 1 18:03:04 2020, Jon, Configuration, VAC, UPS replacements 
    Reply  Thu Jul 9 18:00:35 2020, Jon, Configuration, VAC, UPS replacements 
Entry  Thu Jul 9 16:02:33 2020, Jon, HowTo, CDS, Procedure for setting up BHD front-ends 
Entry  Thu Jul 9 09:22:44 2020, Jordan, Update, General, Presence at 40m 
Entry  Wed Jul 8 08:51:35 2020, Jordan, Update, General, Presence at 40m 
Entry  Tue May 26 02:15:36 2020, gautam, Update, LSC, Lock acquisition portal entry 
    Reply  Tue May 26 02:31:00 2020, gautam, Update, LSC, Lock acquisition sequence PRFPMIlock_1274418200_1274418550.pdf
       Reply  Wed May 27 20:14:51 2020, Koji, Update, LSC, Lock acquisition sequence 
    Reply  Tue May 26 02:37:19 2020, gautam, Update, LSC, DARM loop measurement and fitting DARM_TF.pdfDARM_TF_breakdown.pdf
    Reply  Tue May 26 03:01:35 2020, gautam, Update, LSC, CARM loop  CARM_OLTF.pdf
       Reply  Wed Jun 3 01:46:14 2020, gautam, Update, LSC, CARM loop  CM_loop_topology.pdfCARM_TFs.pdfCARM_OLTF.pdfCARM_xover.pdfCARM_OLG_evolution.pdf
    Reply  Tue May 26 03:06:59 2020, gautam, Update, LSC, PRFPMI sensing matrix PRFPMI_20200524sensMat.pdfPRFPMI_20200524sensMatHistograms.pdf
    Reply  Tue May 26 03:26:58 2020, gautam, Update, LSC, Preliminary noise budget PRFPMI_NB.pdf
    Reply  Tue May 26 14:32:44 2020, gautam, Update, LSC, Arm transmission RIN armRIN.pdf
       Reply  Wed May 27 19:36:33 2020, Koji, Update, LSC, Arm transmission RIN 
          Reply  Thu May 28 18:36:45 2020, gautam, Update, LSC, Arm transmission RIN PRFPMIcorner_ASC_PIT_1274419354_1274419654.pdfPRFPMIcorner_ASC_YAW_1274419354_1274419654.pdfPRFPMIcorner_ASC_coherence_1274419354_1274419654.pdf
             Reply  Fri May 29 00:34:57 2020, rana, Update, LSC, Arm transmission RIN 
             Reply  Wed Jun 3 02:14:32 2020, gautam, Update, ASC, PRC ASC improves arm transmission RIN PRC_ASCsignals.pdfarmRIN_PRC_ASC.pdfPRFPMIcorner_ASC_PIT_1275190251_1275190551.pdfPRFPMIcorner_ASC_YAW_1275190251_1275190551.pdfPRFPMIcorner_ASC_coherence_1275190251_1275190551.pdf
                Reply  Fri Jun 19 16:30:09 2020, gautam, Update, ASC, Some thoughts about ASC sensingResponse.pdfsensingResponse_torque.pdf
                   Reply  Tue Jul 7 14:06:10 2020, gautam, Update, ASC, Some more thoughts about ASC ITM_OL_DCcoupling.png
    Reply  Tue May 26 16:00:06 2020, gautam, Update, LSC, Power buildup diagnostics PRFPMIcorner_DC_1274419354_1274419654.pdfPRFPMIcorner_SB_1274419354_1274419654.pdf
       Reply  Wed May 27 17:41:57 2020, Koji, Update, LSC, Power buildup diagnostics 
          Reply  Wed Jun 3 02:08:00 2020, gautam, Update, LSC, Power buildup diagnostics PRFPMIcorner_DC_1275190251_1275190551.pdfPRFPMIcorner_SB_1275190251_1275190551.pdf
    Reply  Wed Jun 3 01:34:53 2020, gautam, Update, LSC, Lock acquisition update portal 
       Reply  Wed Jun 3 03:29:26 2020, Koji, Update, LSC, Lock acquisition update portal 
          Reply  Wed Jun 3 11:40:56 2020, gautam, Update, LSC, Lock acquisition update portal 
             Reply  Wed Jun 3 18:49:47 2020, gautam, Update, LSC, PRG and CARM signal sign armCavReflectivities.pdfIFOreflectivities.pdfPDHerrSigs.pdfPRGvsLoss_finesse.pdf
Entry  Fri Jun 19 17:06:50 2020, gautam, Update, LSC, What should the short-term commissioning goals be? CARM_superBoost.pdf
    Reply  Wed Jun 24 17:20:16 2020, gautam, Update, LSC, What should the short-term commissioning goals be? 
       Reply  Tue Jun 30 10:59:16 2020, gautam, Update, LSC, Three sensing matrices PRMI_1f_20200625sensMat.pdfPRFPMI_20200629sensMat.pdfPRFPMI_20200629sensMat_wOffset.pdf
          Reply  Mon Jul 6 17:41:19 2020, gautam, Update, LSC, An LSC puzzler LSCsignals.jpg
Entry  Mon Jul 6 15:10:40 2020, Jon, Summary, BHD, 40m --> A+ BHD design analysis 
Entry  Mon Jul 6 08:48:15 2020, Jordan, Update, General, Presence at 40m 
Entry  Thu Jul 2 16:51:23 2020, Jordan, Update, General, Bathroom Science AirScrubber40m.jpg
Entry  Wed Jul 1 12:50:40 2020, gautam, Update, PEM, MC1 accelerometers plugged in IMG_8617.JPGIMG_8616.JPG
Entry  Wed Jul 1 08:51:52 2020, Jordan, Update, General, Presence at 40m 
Entry  Tue Jun 30 22:00:04 2020, gautam, Update, Electronics, Glitchy POX resurfaces glitchyPOX.jpg
Entry  Tue Jun 30 08:50:12 2020, Jordan, Update, General, Presence at 40m 
Entry  Thu Jun 4 20:54:40 2020, gautam, Update, SUS, MC1 Slow Bias issues 
    Reply  Thu Jun 4 21:32:00 2020, Koji, Update, SUS, MC1 Slow Bias issues 
       Reply  Thu Jun 25 15:11:00 2020, gautam, Update, SUS, MC1 coil driver resistance quartered MCF.pdf
          Reply  Sun Jun 28 15:30:52 2020, gautam, Update, SUS, MC1 sat-box de-lidded 20200628T144138.jpg
             Reply  Sun Jun 28 16:29:58 2020, rana, Update, SUS, MC1 sat-box de-lidded 
                Reply  Sun Jun 28 17:36:35 2020, gautam, Update, SUS, MC1 sat-box de-lidded 
                   Reply  Mon Jun 29 11:55:46 2020, gautam, Update, SUS, MC1 sat-box de-lidded SatBoxSwap.jpg
                      Reply  Mon Jun 29 20:30:53 2020, Koji, Update, SUS, MC1 sat-box de-lidded 
Entry  Mon Jun 29 11:41:04 2020, Jordan, Update, General, Presence at 40m 
Entry  Fri Jun 26 11:00:52 2020, Jordan, Update, General, Presence at 40m 
Entry  Thu Jun 25 11:09:01 2020, Jordan, Update, General, Presence at 40m 
Entry  Wed Jun 24 22:47:21 2020, Yehonathan, Update, Wiki, Updated phase maps webpage 
Entry  Wed Jun 24 22:33:44 2020, gautam, Update, SUS, EQ tripped all suspensions 
Entry  Wed Jun 24 10:14:56 2020, Jordan, Update, General, Presence at 40m 
Entry  Mon Jun 22 10:43:25 2020, Jon, Configuration, VAC, Vac maintenance at 11 am 
    Reply  Mon Jun 22 20:06:06 2020, Jon, Configuration, VAC, Vac maintenance complete Pumpdown-6-22-20.png
       Reply  Tue Jun 23 17:54:56 2020, rana, Configuration, VAC, Vac maintenance complete 
Entry  Mon Jun 22 17:51:50 2020, gautam, Update, CDS, c1iscaux was down 
Entry  Mon Jun 22 13:16:38 2020, Jordan, Update, General, Presence at 40m 
Entry  Fri Jun 19 19:21:25 2020, gautam, Update, General, PSL shutter re-opened 
Entry  Fri Jun 19 14:03:50 2020, Jordan, Update, VAC, Forepump Tip Seal Replacement 
Entry  Fri Jun 19 11:02:10 2020, Chub, Update, General, custom feedthrough flanges are here! 
Entry  Thu Jun 11 11:48:43 2020, gautam, Update, VAC, Vac failure vacFailure.png
    Reply  Thu Jun 11 16:14:03 2020, gautam, Update, VAC, Vac failure - probable cause is serial comm glitch TP2_tempGlitch.pngPSL_shutterClosed.pngTP2tempGlitches.pdf
       Reply  Thu Jun 11 17:35:34 2020, gautam, Update, VAC, Pumpspool UPS needs battery replacement 
          Reply  Fri Jun 12 01:23:32 2020, Koji, Update, VAC, Pumpspool UPS needs battery replacement 
             Reply  Fri Jun 12 17:32:40 2020, Koji, Update, VAC, Pumpspool UPS needs battery replacement Screen_Shot_2020-06-12_at_17.22.23.png
                Reply  Fri Jun 12 19:02:52 2020, gautam, Update, VAC, Pumpspool UPS needs battery replacement 
                   Reply  Fri Jun 12 19:23:56 2020, Koji, Update, VAC, Pumpspool UPS needs battery replacement 
                      Reply  Fri Jun 12 19:33:31 2020, gautam, Update, VAC, Pumpspool UPS needs battery replacement 
                         Reply  Tue Jun 16 13:35:03 2020, Jon, Update, VAC, Temporary vac fix / IFO usable again Pumpdown.png
                            Reply  Wed Jun 17 16:27:51 2020, gautam, Update, VAC, Questions/comments on vacuum 
                               Reply  Thu Jun 18 11:00:24 2020, Jon, Update, VAC, Questions/comments on vacuum 
                                  Reply  Thu Jun 18 12:00:36 2020, gautam, Update, VAC, Questions/comments on vacuum 
                                     Reply  Thu Jun 18 14:13:03 2020, Jon, Update, VAC, Questions/comments on vacuum 
                                        Reply  Thu Jun 18 15:46:34 2020, gautam, Update, VAC, Questions/comments on vacuum 
                                           Reply  Fri Jun 19 07:40:49 2020, Jon, Update, VAC, Questions/comments on vacuum 
                                              Reply  Fri Jun 19 09:57:35 2020, gautam, Update, VAC, Questions/comments on vacuum 
Entry  Fri Jun 19 08:47:10 2020, Jordan, Update, General, Presence at 40m 
Entry  Thu Jun 18 22:33:57 2020, Jon, Omnistructure, VAC, Vac hardware purchase list 
Entry  Thu Jun 18 15:25:08 2020, Jordan, Update, VAC, TP2 and TP3 Forepump removal 
    Reply  Thu Jun 18 16:56:34 2020, Jordan, Update, VAC, TP2 and TP3 Forepump removal 
Entry  Thu Jun 18 09:46:03 2020, Jordan, Update, General, Presence at 40m 
Entry  Tue Jun 16 16:05:26 2020, Jordan, Update, General, N2 Replacement 
Entry  Wed May 20 19:34:58 2020, Koji, Update, General, ITM spares and New PR3 mirrors transported to Downs for phasemap measurement container.jpg
    Reply  Thu Jun 4 00:21:28 2020, Koji, Summary, COC, ITM spares and New PR3 mirrors transported to Downs for phasemap measurement 
    Reply  Tue Jun 16 13:05:36 2020, Koji, Update, COC, ITM spares and New PR3 mirrors transported to Downs for phasemap measurement 40m_Optics.jpg
Entry  Tue Jun 16 08:58:11 2020, Jordan, Update, General, Presence at 40m 
Entry  Fri Jun 12 11:40:14 2020, Jordan, Update, General, Presence at 40m 
Entry  Thu Jun 11 11:14:12 2020, Jordan, Update, General, Presence at 40m 
Entry  Sat Jun 6 14:07:30 2020, Jon, Update, BHD, Stock-Part Mode-Matching Telescope Option ASpathStock.pdfLOpathStock.pdf
    Reply  Mon Jun 8 11:50:02 2020, Hang, Update, BHD, Astigmatism and scattering plots 6x
       Reply  Mon Jun 8 12:49:07 2020, Koji, Update, BHD, Astigmatism and scattering plots 
          Reply  Mon Jun 8 17:40:22 2020, Jon, Update, BHD, Astigmatism and scattering plots LOpathStock2.pdf
             Reply  Mon Jun 8 21:45:47 2020, Jon, Update, BHD, Astigmatism and scattering plots 
                Reply  Thu Jun 11 09:37:38 2020, Jon, Update, BHD, Conclusions on Mode-Matching Telescopes 
Entry  Wed Jun 10 14:00:33 2020, Jordan, Update, General, Presence at 40m 
Entry  Tue Jun 9 15:02:56 2020, eHang, Update, BHD, Astigmatism and scattering plots LO_MM_t_scat_stock.pdfLO_MM_s_scat_stock.pdfLO_MM_adj_stock.pdf
Entry  Tue Jun 2 14:05:24 2020, Hang, Update, BHD, MM telescope actuation range requirments TM_OL_spec_1274418500_512.pdfCORNER_OL_spec_1274418500_512.pdf
    Reply  Tue Jun 9 14:55:43 2020, Jon, Update, BHD, MM telescope actuation range requirments 
Entry  Tue Jun 9 09:35:02 2020, Jordan, Update, General, Presence at 40m 
Entry  Mon Jun 8 18:14:55 2020, gautam, Update, CDS, Vertex FEs crashed FEcrash_CDSoverview.png
Entry  Fri Jun 5 08:44:50 2020, Jordan, Update, General, Presence at 40m 
Entry  Thu Jun 4 08:45:41 2020, Jordan, Update, General, Presence at 40m 
Entry  Wed Jun 3 19:19:11 2020, gautam, Update, SUS, All watchdogs tripped 
Entry  Wed Jun 3 11:20:19 2020, gautam, Update, DetChar, Summary pages 
Entry  Tue May 26 01:58:57 2020, gautam, Update, Electronics, Some electronics thoughts IMCsensingNoise.pdfIMCsensingNoise.pdf
    Reply  Wed Jun 3 01:40:13 2020, gautam, Update, Electronics, More electronics woes glitchySeis2.pngglitchySeis3.png
Entry  Tue May 26 19:19:30 2020, Hang, Update, BHD, BHD MM-- effects of astigmatism MM.pdf
Entry  Tue May 26 10:04:54 2020, Jordan, Update, General, N2 Replacement 
Entry  Fri May 22 10:14:47 2020, Jordan, Update, General, Nitrogen Replacement 
Entry  Fri May 22 01:43:18 2020, gautam, Update, Electronics, RF electronics trouble RFPDglitches.png
Entry  Wed May 20 18:45:22 2020, Hang, Update, BHD, BHD mode-matching study--corner plot & adjustment requirement AS_MM_scat2.pdfAS_MM_adj2.pdf
Entry  Sat May 9 17:01:08 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation ITMX_Loss_Map.pdfETMX_Loss_Map.pdfITMX_Phase_Map_(nm).pdfETMX_Phase_Map_(nm).pdf
    Reply  Wed May 13 15:13:11 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation ITMX_Loss_Map.pdfETMX_Loss_Map.pdf
       Reply  Thu May 14 12:21:56 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation ITMX_Loss_Map_Perturbation_Theory.pdfETMX_Loss_Map_Perturbation_Theory(1).pdf
          Reply  Thu May 14 19:00:43 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation 
             Reply  Tue May 19 15:39:04 2020, Yehonathan, Update, Loss Measurement, 40m Phase maps loss estimation Mode_power_fraction1.pdf
Entry  Mon May 18 18:00:16 2020, Hang, Update, BHD, BHD mode-matching study MM.pdf
    Reply  Tue May 19 15:24:06 2020, rana, Update, BHD, BHD mode-matching study 
Entry  Fri May 15 19:10:42 2020, gautam, Update, SUS, All watchdogs tripped, now restored 
Entry  Fri May 15 09:18:04 2020, Jon, Update, BHD, BHD telescope designs accounting for ASC LOpath.pdfASpath.pdf
Entry  Tue May 12 17:51:25 2020, rana, Summary, Computer Scripts / Programs, updated LESS syntax highlight on nodus 
    Reply  Thu May 14 00:47:55 2020, gautam, Summary, Computer Scripts / Programs, pcdev1 added to authorized keys on nodus 
Entry  Thu May 14 00:21:03 2020, gautam, Update, LSC, CM board boosts boosts.pdfboosts_noise.pdf
Entry  Tue May 12 18:16:17 2020, gautam, Update, LSC, Relative importance of losses in the arm and PRC armLossVSPRCloss.pdf
    Reply  Tue May 12 20:16:31 2020, Koji, Update, LSC, Relative importance of losses in the arm and PRC 
       Reply  Tue May 12 22:47:49 2020, gautam, Update, LSC, Relative importance of losses in the arm and PRC 
Entry  Mon May 11 00:12:34 2020, gautam, Update, LSC, RF only PRFPMI PRFPMIlock.pdfIMG_8549.JPGIMG_8548.JPGDARM_OLTF.pdf
Entry  Fri May 8 14:27:25 2020, Hang, Update, BHD, New SRC gouy phase mode_spec_finesse.pdfmode_spec_ideal.pdf
Entry  Tue May 5 23:44:14 2020, gautam, Update, ASC, IMC WFS WFSmatrixComparison.pdfWFSheadNoise.pdf
    Reply  Thu May 7 09:43:21 2020, rana, Update, ASC, IMC WFS 
       Reply  Thu May 7 10:58:06 2020, gautam, Update, ASC, IMC WFS 
Entry  Wed May 6 00:31:09 2020, gautam, Update, ALS, Optomechanics during CARM offset reduction CARMplant.pdfCARMplant_force2disp.pdf
Entry  Fri May 1 01:49:55 2020, gautam, Update, ALS, ASY commissioning 
    Reply  Fri May 1 22:44:17 2020, gautam, Update, ALS, ASY M2 PZT damaged 
       Reply  Sat May 2 02:35:18 2020, Koji, Update, ALS, ASY M2 PZT damaged 
Entry  Thu Apr 30 07:29:01 2020, Chub, Update, VAC, N2 delivered. 
Entry  Fri Apr 24 00:26:59 2020, rana, Summary, PEM, L.A. EQ from Tuesday night April22-EQ.pdf
Entry  Wed Apr 22 17:29:14 2020, gautam, Update, PSL, FSS debugging attempts FSSspec.pdf
    Reply  Thu Apr 23 10:42:02 2020, rana, Update, PSL, FSS debugging attempts 
Entry  Sat Apr 18 13:32:31 2020, rana, Update, Cameras, GigE w better NIR sensitivvity 
    Reply  Thu Apr 23 09:52:02 2020, Jon, Update, Cameras, GigE w better NIR sensitivvity 
Entry  Wed Apr 22 13:52:05 2020, gautam, Update, DetChar, Summary page revival 
Entry  Mon Apr 20 17:49:58 2020, gautam, Update, General, Some housekeeping fDomainWF_Apr06.pdffDomainWF_Apr20.pdf
Entry  Tue Mar 10 19:59:09 2020, Yehonathan, Update, Loss Measurement, Arm transfer function measurement YArmFrequencyResponse.pdf
    Reply  Thu Mar 12 10:43:50 2020, rana, Update, Loss Measurement, Arm transfer function measurement 
       Reply  Mon Mar 16 15:23:03 2020, Yehonathan, Update, Loss Measurement, Arm transfer function measurement Cross_calibration_setup.jpgPDA520overPDA255_Response.pdfYArmFrequencyResponse.pdf
          Reply  Sat Apr 18 14:57:44 2020, Yehonathan, Update, Loss Measurement, Arm transfer function measurement 
Entry  Fri Jan 24 13:56:21 2020, Jon, Update, BHD, BHD optics specifications 
    Reply  Thu Apr 16 21:13:20 2020, Jon, Update, BHD, BHD optics specifications LO_Beam_Calc-v1.pdfAS_Beam_Calc-v1.pdf
Entry  Wed Apr 15 15:15:17 2020, Chub, Update, VAC, nitrogen cylinders delivered 
Entry  Tue Apr 14 23:50:06 2020, Koji, Update, General, 40m power glitch recovery 
Entry  Mon Apr 13 16:51:49 2020, rana, Summary, DAQ, NODUS: rsyncd daemon / service set up 
Entry  Mon Apr 13 15:28:07 2020, Koji, Update, General, Power Event and recovery 
Entry  Tue Apr 7 15:30:40 2020, Jon, Summary, NoiseBudget, 40m noise budget migrated to pygwinc 
Entry  Fri Apr 3 13:40:07 2020, Jon, Update, BHD, BHD front-end complication 
    Reply  Tue Apr 7 10:56:39 2020, Jon, Update, BHD, BHD front-end complication 
Entry  Thu Apr 2 15:53:01 2020, gautam, Update, ASC, PRMI 1f locked for collecting feedforward data 
    Reply  Fri Apr 3 17:15:53 2020, gautam, Update, ASC, POP angular FF filters trained and tested FIRvIIR.pdfPRM_act_calib.pdfIIR_fit_to_FIR_PIT.pdfIIR_fit_to_FIR_YAW.pdfPOP_DC_comparison.pdf
       Reply  Mon Apr 6 12:26:07 2020, rana, Update, ASC, POP angular FF filters trained and tested 
          Reply  Mon Apr 6 16:46:40 2020, gautam, Update, ASC, POP angular FF filters trained and tested PRCL_comparison.pdf
Entry  Thu Mar 26 22:31:34 2020, Yehonathan, Update, CDS, C1AUXEY wiring + channel list 
    Reply  Thu Apr 2 16:31:33 2020, Jon, Update, CDS, C1AUXEY wiring + channel list 
       Reply  Thu Apr 2 22:19:18 2020, Koji, Update, CDS, C1AUXEY wiring + channel list 
          Reply  Fri Apr 3 12:09:53 2020, Jon, Update, CDS, C1AUXEY wiring + channel list 
Entry  Tue Mar 24 19:41:57 2020, gautam, Update, Wiener, Seismic feedforward for MCL IMCseisFF.pdffilterComp.pdfoldFilter_v_proposed.pdfMCL_ff_performance.pdf
    Reply  Wed Apr 1 00:51:41 2020, gautam, Update, Wiener, Slightly improved MCL FF MC2_act_calib.pdfIIR_fit_to_FIR.pdfFIRvIIR.pdf
Entry  Tue Mar 31 09:39:41 2020, gautam, Update, CDS, Foton for shaped noise injections 
    Reply  Tue Mar 31 23:35:50 2020, rana, Update, CDS, Foton for shaped noise injections 
       Reply  Tue Mar 31 23:54:57 2020, gautam, Update, CDS, Foton for shaped noise injections 
Entry  Mon Mar 30 19:02:49 2020, rana, Update, General, donated cleanroom supplies to Hospitals 
Entry  Thu Mar 26 17:41:18 2020, Jon, Omnistructure, BHD, BHD docs compilation 
Entry  Thu Jan 10 19:59:08 2019, Jon, Update, VAC, Vac System Running Normally on Turbo Pumps Screen_Shot_2019-01-10_at_7.58.24_PM.pngCCs.pngTPs.png
    Reply  Fri Jan 25 16:14:51 2019, gautam, Update, VAC, Vacuum interlock code, N2 warning 
       Reply  Wed Mar 25 15:15:55 2020, gautam, Update, VAC, Vacuum interlock code, N2 warning update 
Entry  Thu Mar 12 01:33:21 2020, gautam, Update, LSC, Resuming locking activities ExcessFreqNoise_LSC.pdf
    Reply  Fri Mar 13 00:32:38 2020, gautam, Update, LSC, Some progress RFonly_CARM.pngCARMTF.pdf
       Reply  Tue Mar 17 01:22:03 2020, gautam, Update, LSC, Locking updates 
          Reply  Thu Mar 19 03:33:28 2020, gautam, Update, LSC, More locking updates PRFPMI_lock.pngCARMTF.pdfDARM_AvB.pdflockLoss.png
Entry  Wed Mar 18 21:43:26 2020, gautam, Update, VAC, Main vol pressure jump VacPresJump.png
    Reply  Wed Mar 18 22:10:41 2020, Koji, Update, VAC, Main vol pressure jump 
Entry  Fri Mar 13 20:00:50 2020, Jon, Update, Computers, Loopback monitoring for slow machines Screen_Shot_2020-03-13_at_7.59.55_PM.png
Entry  Fri Mar 13 14:28:39 2020, gautam, Update, PSL, Added tees to PMC Trans and REFL 
Entry  Fri Mar 13 12:48:47 2020, Larry Wallace, Update, elog, Cert Renewal 
Entry  Thu Mar 12 16:13:16 2020, gautam, Update, PSL, Temperature sensors connected to Acromag P_20200317_153736_vHDR_On_2.jpg
Entry  Thu Mar 12 11:10:49 2020, Yehonathan, Update, General, PMC got unlcoked 
    Reply  Thu Mar 12 12:44:34 2020, gautam, Update, General, PMC got unlcoked 
Entry  Wed Mar 11 21:03:57 2020, Koji, Update, BHD, SOS packages from Syracuse P_20200311_203449_vHDR_On.jpg
Entry  Mon Mar 2 16:29:40 2020, gautam, Update, Electronics, c1psl VME crate removed, Acro-crate installed c1psl.pdf
    Reply  Tue Mar 3 17:20:14 2020, gautam, Update, Electronics, More cabling removed 
       Reply  Wed Mar 4 16:18:31 2020, gautam, Update, Electronics, More cabling removed 1X2EuroBefore.JPGIOO.png
          Reply  Wed Mar 4 21:02:49 2020, Koji, Update, Electronics, More cabling removed 
    Reply  Tue Mar 3 17:59:33 2020, Yehonathan, Update, Electronics, PSL Shutter and PMC TRANSPD working 
       Reply  Thu Mar 5 15:03:48 2020, Yehonathan, Update, Electronics, PSL Shutter and PMC TRANSPD working 
          Reply  Thu Mar 5 19:45:23 2020, Jon, Summary, PSL, C1PSL in-situ test results c1psl_feedthrough_wiring_-_By_Connector_(3).pdf
             Reply  Wed Mar 11 18:12:53 2020, gautam, Summary, PSL, WFS Demod board modifications D980233-B_Mar2020Mods.pdf
Entry  Tue Feb 25 19:58:06 2020, Hang, Update, IOO, MC2 coil balancing 
    Reply  Wed Mar 11 16:46:25 2020, Hang, Update, IOO, MC2 coil balancing 
Entry  Tue Mar 10 14:30:16 2020, yehonathan, Update, SUS,  Screenshot_from_2020-03-10_19-02-31.png
    Reply  Tue Mar 10 19:58:16 2020, yehonathan, Update, SUS,  
Entry  Sat Mar 7 15:18:30 2020, gautam, Update, SUS, EQ tripped some suspensions EQ_6Mar.png
Entry  Fri Mar 6 01:19:19 2020, gautam, Update, IOO, Excess laser frequency noise MCF.pdfExcessFreqNoise.pdfALSnoise.pdf
    Reply  Fri Mar 6 16:33:11 2020, gautam, Update, IOO, Excess laser frequency noise 
Entry  Wed Mar 4 20:42:53 2020, gautam, Update, Electronics, C1PSL acromag crate is sitting on the floor 
    Reply  Thu Mar 5 11:27:48 2020, gautam, Update, Electronics, C1PSL acromag crate is no longer sitting on the floor 
       Reply  Thu Mar 5 19:51:14 2020, gautam, Update, Electronics, IMC Servo board being tested 
          Reply  Fri Mar 6 01:12:10 2020, gautam, Update, Electronics, IMC Servo IN2 path looks just fine AO_inputTFs_5Mar.pdfsliderCal_5Mar.pdf
Entry  Wed Mar 4 22:38:31 2020, Jon, Update, PSL, c1psl communications problem resolved 
Entry  Wed Mar 4 16:54:43 2020, gautam, Update, CDS, c1auxex temporarily disconnected 
Entry  Wed Mar 4 12:25:11 2020, gautam, Update, CDS, BIO1 on c1psl is dead 
Entry  Wed Mar 4 11:16:37 2020, gautam, Update, PSL, PMC realignment PMCrealignment.png
Entry  Wed Mar 4 11:10:47 2020, Yehonathan, Update, Computers, Allegra revival 
Entry  Tue Mar 3 19:11:48 2020, gautam, Update, LSC, Some locking prep 
Entry  Wed Feb 26 21:43:48 2020, Jon, Summary, BHD, Projected IFO noise budget, post-BHD upgrade 40m_phase_quad.pdf40m_aligo_comp.pdf40m_ampl_quad.pdfnoise_budget.tar
    Reply  Wed Feb 26 22:09:52 2020, gautam, Summary, BHD, Projected IFO noise budget, post-BHD upgrade 
       Reply  Mon Mar 2 23:49:03 2020, Jon, Summary, BHD, Projected IFO noise budget, post-BHD upgrade 40m_phase_quad.pdf40m_ampl_quad.pdf40m_aligo_comp.pdf
          Reply  Tue Mar 3 18:11:05 2020, Jon, Summary, BHD, Projected IFO noise budget, post-BHD upgrade 40m_phase_quad.pdf40m_ampl_quad.pdf40m_aligo_comp.pdf
Entry  Mon Mar 2 19:32:41 2020, gautam, Update, CDS, c1rfm errors RFMerrors.png
Entry  Mon Mar 2 16:35:12 2020, gautam, Update, CDS, c1psl test status 
Entry  Mon Mar 2 16:14:47 2020, gautam, Update, CDS, some target directory cleanup 
Entry  Thu Feb 27 17:50:36 2020, gautam, Update, PSL, c1psl setup setup 20200227_173535.jpg20200227_173454_HDR.jpg20200227_172659.jpg
    Reply  Fri Feb 28 08:05:22 2020, gautam, Update, PSL, c1psl setup setup 
       Reply  Fri Feb 28 10:04:41 2020, gautam, Update, PSL, c1psl setup setup 
          Reply  Fri Feb 28 19:37:18 2020, gautam, Update, PSL, New c1psl installed 
Entry  Thu Feb 27 22:45:40 2020, gautam, Update, ALS, ALS noise high ALSnoise.pdf
Entry  Thu Feb 27 17:59:02 2020, gautam, Update, LSC, Some AO thoughts 
Entry  Thu Feb 27 15:50:37 2020, gautam, Update, Electronics, FSS box power cable removed 
Entry  Wed Feb 26 22:05:06 2020, gautam, Update, IOO, IMC checks 
    Reply  Wed Feb 26 23:50:51 2020, gautam, Update, IOO, IMC checks sliderCal.pdfAO_inputTFs.pdf
Entry  Wed Feb 26 17:17:17 2020, Yehonathan, Update, , Arms DC loss measurements 6x
Entry  Tue Feb 25 16:17:57 2020, Gautam, Hang, Update, CDS,  
Entry  Mon Feb 24 08:36:32 2020, Chub, Update, General, HVAC repair 
Entry  Thu Feb 13 21:30:55 2020, shruti, Update, ALS, ALS OOL noise with arms locked 20200213_ALS.pdf
    Reply  Fri Feb 14 14:02:13 2020, shruti, Update, ALS, ALS OOL noise with arms locked 819472_10.pdf225642_10.pdf693500_10.pdf
       Reply  Fri Feb 14 14:52:41 2020, gautam, Update, ALS, ALS OOL noise with arms locked 
          Reply  Tue Feb 18 18:14:59 2020, shruti, Update, ALS, ALS OOL noise with arms locked ALSNoise.pdf
             Reply  Wed Feb 19 22:20:22 2020, rana, Update, ALS, ALS OOL noise with arms locked 
             Reply  Fri Feb 21 10:59:08 2020, shruti, Update, ALS, PDH error signals? IMG_0082.jpgIMG_0083.jpgIMG_0084.jpgIMG_0085.jpg
                Reply  Fri Feb 21 13:02:53 2020, Koji, Update, ALS, PDH error signals? 
                   Reply  Fri Feb 21 20:44:18 2020, shruti, Update, ALS, ALS OOL noise and PDH ALSNoise.pdfIMG_0086.jpg
                      Reply  Sun Feb 23 18:15:22 2020, rana, Update, ALS, ALS OOL noise and PDH 
Entry  Fri Dec 27 16:26:11 2019, Yehonathan, Update, PSL, PMC Linewidth measurement PMCTransmissionSpectra.pdf
    Reply  Wed Jan 1 14:14:00 2020, Yehonathan, Update, PSL, PMC Linewidth measurement 150MHzSideBandCreation.pdfLinewidthMeasurment.pdf
       Reply  Wed Jan 15 15:04:31 2020, gautam, Update, PSL, PMC Linewidth measurement 
          Reply  Fri Jan 17 22:11:19 2020, Yehonathan, Update, PSL, Ringdown measurements 20200117_192455.jpg20200117_192448.jpg
             Reply  Sat Jan 25 11:54:42 2020, Yehonathan, Update, PSL, Ringdown measurements Input_beam_path.jpgReflected_Beam_Path.jpgTransmitted_Beam_Path.jpgPMCRingdownNormalizedRawdata.pdfTransPDFits.pdf
                Reply  Mon Jan 27 21:35:06 2020, Yehonathan, Update, PSL, Ringdown measurements IMC_REFL_Beam_Path.jpg
                   Reply  Mon Jan 27 21:48:49 2020, gautam, Update, PSL, Ringdown measurements elevatedSeis.pdf
                      Reply  Tue Jan 28 16:01:17 2020, gautam, Update, IOO, IMC WFS servos stable again QPD_recenter.png
                         Reply  Tue Jan 28 20:51:37 2020, Yehonathan, Update, IOO, IMC WFS servos stable again 
                            Reply  Wed Jan 29 12:40:24 2020, Yehonathan, Update, IOO, IMC Ringdowns preliminary data analysis IMCRingdownNormalizedRawdata.pdfIMCTransPDFits.pdf
                               Reply  Mon Feb 3 13:54:10 2020, Yehonathan, Update, IOO, IMC Ringdowns extended data analysis IMCTransReflAnalysis_anotated.pdf
                                  Reply  Wed Feb 5 21:13:17 2020, Yehonathan, Update, IOO, IMC Ringdowns extended data analysis 
                                     Reply  Sat Feb 15 12:56:24 2020, Yehonathan, Update, IOO, IMC Transfer function measurement IMCFrequencyResponse.pdfIMCRingdownNormalizedRawdata.pdfIMCREFLPDFits.pdf
Entry  Thu Feb 13 01:47:39 2020, gautam, Update, ALS, Fast ALS - delay line prep delaySlider.pngdelayLineLosses.pdfdelayLineCal.pdf
    Reply  Fri Feb 14 00:53:50 2020, gautam, Update, ALS, Fast ALS - more setup CMSlow_ALSnoise.pdfOLTFmeas.pdf
Entry  Wed Feb 12 12:13:37 2020, gautam, Update, LSC, AO path attempts CARM_OLTF.pdfPRFPMI_errSigs.pdf
    Reply  Thu Feb 13 02:07:26 2020, gautam, Update, LSC, AO path transfer function measurement AOpathTF.pdfIMCinLoop.pdf
Entry  Tue Feb 11 19:11:35 2020, shruti, Update, Computer Scripts / Programs, MATLAB on donatella 
Entry  Tue Feb 11 16:39:00 2020, shruti, Update, ALS, AM/PM AM.pdfPM.pdfRatio_all.pdfRatios_FM_PM.pdfRatio_all_new.pdf
Entry  Mon Feb 10 15:55:46 2020, Jordan, Update, PSL, PMCTRANSPD ADC1.jpg
Entry  Mon Feb 10 15:54:47 2020, Jordan, Update, PSL, Completed Acromag Wiring 
Entry  Mon Feb 10 15:04:42 2020, Jordan, Update, General, HDMI Routing for new tv  
Entry  Mon Feb 10 10:07:20 2020, gautam, Update, PSL, PMC re-locked PMCunlock.png
Entry  Mon Feb 10 09:40:54 2020, Larry Wallace, Summary, General, SolidWorks Computer Upgrade and Printer repair 
Entry  Fri Feb 7 15:00:16 2020, gautam, Update, LSC, More high BW POY experiments AO_TFs.pdf
    Reply  Fri Feb 7 19:39:10 2020, Koji, Update, LSC, More high BW POY experiments 
Entry  Fri Jan 31 16:57:09 2020, gautam, Update, General, Metal PMC parts 
    Reply  Fri Feb 7 12:58:25 2020, Yehonathan, Update, General, Metal PMC parts 18x
Entry  Fri Feb 7 09:45:03 2020, shruti, Update, General, AM at X end 
Entry  Thu Feb 6 16:14:44 2020, rana, Update, General, office area temperature 
    Reply  Fri Feb 7 02:41:28 2020, Koji, Update, General, office area temperature 
Entry  Tue Feb 4 02:13:02 2020, gautam, Update, LSC, Locking updates modifiedOutMat.pngOLTFs.pdf
    Reply  Wed Feb 5 16:35:12 2020, gautam, Update, LSC, Diagnosis plan ALSnoise.pdf
       Reply  Thu Feb 6 01:16:58 2020, gautam, Update, LSC, Diagnosis results IMCspec_ALS.pdfIMCspec_ALS_smallSpan.pdf
    Reply  Thu Feb 6 01:25:50 2020, gautam, Update, LSC, Locking updates semiStableArms.pngarmAngStability.png
       Reply  Fri Feb 7 02:24:24 2020, gautam, Update, LSC, Some short notes 
Entry  Thu Feb 6 21:54:13 2020, Jon, Update, PSL, c1psl bench testing complete 
Entry  Tue Feb 4 18:13:01 2020, Yehonathan, Update, PSL, Bench testing of PSL ai channels c1psl_wire_testing_-_By_Connector.pdf
    Reply  Wed Feb 5 08:57:11 2020, Yehonathan, Update, PSL, Bench testing of PSL ai channels 
       Reply  Wed Feb 5 21:04:10 2020, Yehonathan, Update, PSL, Bench testing of PSL ai channels 
Entry  Mon Feb 3 15:22:39 2020, Jon, Update, PSL, c1psl progress/Acromag ADC grounding 
Entry  Fri Jan 31 16:04:30 2020, gautam, Update, IOO, Input pointing drift IPdrift.pdfIPdrift_PRMI.pdf
Entry  Wed Jan 29 12:29:33 2020, shruti, Update, General, delay line frequency discriminator for PM 20200128.pngIMG_BB01C068495A-1.jpeg
    Reply  Thu Jan 30 15:24:10 2020, ?, Update, General, delay line frequency discriminator for PM 
       Reply  Thu Jan 30 22:02:42 2020, shruti, Update, General, delay line frequency discriminator for PM Figure_2.png
Entry  Thu Jan 30 17:31:28 2020, Jon, Update, PSL, Errant FSS_INOFFSET change 
    Reply  Thu Jan 30 17:41:10 2020, gautam, Update, PSL, Errant FSS_INOFFSET change 
Entry  Thu Jan 30 12:52:10 2020, Jon, Update, BHD, Metal OMCs procured 
Entry  Wed Jan 29 03:05:47 2020, rana, gautam, Update, SUS, MC misalignments / sat box games IMG_8366.JPG
Entry  Wed Jan 29 00:29:43 2020, gautam, Update, LSC, locking 2020 PRFPMI_2020Jan.png
Entry  Wed Jan 29 00:27:13 2020, gautam, Update, Computer Scripts / Programs, mcup / mcdown modified 
Entry  Tue Dec 3 22:41:17 2019, shruti, Update, General, PLL for PM measurement  PM_measurement.jpeg
    Reply  Wed Dec 4 20:32:43 2019, gautam, Update, General, PLL for PM measurement  
    Reply  Mon Dec 9 21:22:46 2019, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT 
       Reply  Tue Dec 17 20:08:09 2019, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT 20191217.png
          Reply  Thu Jan 16 19:32:23 2020, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT 
             Reply  Thu Jan 23 20:08:49 2020, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT Image-1.jpg
                Reply  Tue Jan 28 19:40:15 2020, shruti, Update, General, PLL / PM measurement of Xend NPRO PZT PMTF.pdfBeatSpectrum.pdf
Entry  Tue Jan 28 19:12:30 2020, Jon, Configuration, PSL, Spare channels added to c1psl chassis c1psl_feedthrough_wiring_v2.pdf
Entry  Sun Dec 8 20:48:29 2019, rana, Configuration, Computers, Megatron: starts up grade 
    Reply  Wed Dec 11 22:01:24 2019, rana, Configuration, Computers, Megatron: starts up grade 
       Reply  Wed Jan 22 19:17:20 2020, gautam, Configuration, Computers, Megatron: starts up grade 
          Reply  Thu Jan 23 15:32:42 2020, gautam, Configuration, Computers, Megatron: starts up grade 
             Reply  Mon Jan 27 18:16:30 2020, gautam, Configuration, Computers, Sluggish megatron? 
                Reply  Tue Jan 28 15:39:04 2020, gautam, Configuration, Computers, Sluggish megatron? 
                   Reply  Tue Jan 28 17:36:45 2020, gautam, Configuration, Computers, Local EPICS7.0 installed on megatron 
Entry  Mon Jan 20 20:20:36 2020, gautam, Update, PSL, PMC servo checkout PMCsweep.pdfOLTFmeas.pdf
    Reply  Wed Jan 22 11:22:39 2020, gautam, Update, PSL, PMC modulation depth measurement modDepth.pdf
       Reply  Wed Jan 22 20:12:36 2020, gautam, Update, PSL, PMC demodulator electrical characterization demodChar.pdfmixerChar.pdf
          Reply  Thu Jan 23 14:37:05 2020, gautam, Update, PSL, PMC VGA chip damaged? VGAchar.pdf
             Reply  Thu Jan 23 16:37:14 2020, rana, Update, PSL, PMC VGA chip damaged? 
             Reply  Thu Jan 23 22:10:01 2020, gautam, Update, PSL, PMC servo pulled out 
                Reply  Fri Jan 24 15:42:08 2020, gautam, Update, PSL, PMC servo restored 
                   Reply  Sun Jan 26 13:47:00 2020, gautam, Update, PSL, PMC servo characterization elecTFs.pdfVGAchar_postFix.pdfVGAlinearity_postFix.pdfnewOLTFs.pdf
                      Reply  Tue Jan 28 14:33:24 2020, gautam, Update, PSL, Inferred free-running frequency noise inLoopNoise_IMClocked.pdffreqNoiseComparison.pdf
          Reply  Thu Jan 23 18:52:31 2020, gautam, Update, PSL, PMC RFPD characterization PDresp.pdf
Entry  Tue Jan 28 08:26:53 2020, rana, Frogs, PEM, shaking 
Entry  Mon Jan 27 14:01:01 2020, Jordan, Configuration, General, Repurposed Sorenson Power Supply  
Entry  Sun Jan 26 14:40:55 2020, gautam, Update, ALS, ALS OOL noise ALSnoise_20200126.pdf
Entry  Sun Jan 26 13:30:19 2020, gautam, Update, SUS, All watchdogs tripped, now restored EQ_Jan25.pdf
Entry  Fri Jan 17 18:02:21 2020, gautam, Update, ALS, Gain blocks packaged and characterized photos.pdfgain.pdfnoise.pdfmeasSchem.pdfzhl1010Data.zip
    Reply  Fri Jan 24 17:14:01 2020, gautam, Update, ALS, Gain blocks installed 
Entry  Thu Jan 23 23:07:04 2020, Jon, Configuration, PSL, c1psl breakout board wiring c1psl_feedthrough_wiring.pdf
Entry  Wed Jan 22 16:19:47 2020, Jon, Update, VAC, TP3 controller errors 
Entry  Mon Dec 9 19:19:04 2019, Yehonathan, Update, PSL, AOM first order beam alignment 20191209_193112.jpg20191209_193203_HDR.jpgimageedit_2_7551928142.gifimageedit_3_5863650538.gif
    Reply  Tue Dec 10 01:24:17 2019, Yehonathan, Update, PSL, AOM first order beam alignment 
       Reply  Tue Dec 10 13:26:46 2019, Yehonathan, Update, PSL, AOM first order beam alignment 
    Reply  Fri Jan 17 21:56:22 2020, Yehonathan, Update, PSL, AOM first order beam alignment 20200117_174841.jpg
       Reply  Wed Jan 22 11:00:21 2020, gautam, Update, PSL, PMC REFL ghost beam 
Entry  Mon Jan 20 15:11:20 2020, gautam, Update, PSL, PMCT photodiode grounding issue PMCT_anomaly.pdf
Entry  Mon Jan 20 12:16:50 2020, gautam, Update, PSL, PMC input reverted to AOM zeroth order beam IMG_8362.JPG
Entry  Wed Jan 15 16:54:51 2020, gautam, Update, General, PDA10CF removed from AS table 
Entry  Mon Jan 6 15:36:55 2020, Jon, Update, PSL, Assembly underway for c1psl upgrade 
    Reply  Mon Jan 6 16:07:12 2020, gautam, Update, PSL, Assembly underway for c1psl upgrade 
       Reply  Mon Jan 6 19:05:09 2020, not gautam, Update, PSL, Assembly underway for c1psl upgrade 
    Reply  Fri Jan 10 19:48:46 2020, yehonathan, Update, PSL, Assembly underway for c1psl upgrade 20200110_194429.jpg20200110_194516_HDR.jpg
       Reply  Mon Jan 13 16:05:18 2020, yehonathan, Update, PSL, Assembly underway for c1psl upgrade 
          Reply  Tue Jan 14 17:16:43 2020, yehonathan, Update, PSL, Assembly underway for c1psl upgrade 
             Reply  Wed Jan 15 10:12:46 2020, gautam, Update, PSL, Assembly underway for c1psl upgrade 
                Reply  Wed Jan 15 16:08:40 2020, not gautam, Update, PSL, Assembly underway for c1psl upgrade 
Entry  Wed Jan 15 14:10:28 2020, Jon, Configuration, PSL, New EPICS database for C1PSL + C1IOO 
Entry  Mon Jan 13 23:30:53 2020, Yehonathan, Summary, PSL, Changes made since Gautam left 
    Reply  Tue Jan 14 20:17:09 2020, gautam, Summary, General, IFO recovery DCerrors.png
       Reply  Wed Jan 15 10:04:19 2020, gautam, Summary, General, POX / POY locking restored singleArms.png
Entry  Mon Jan 13 15:47:37 2020, shruti, Configuration, Computer Scripts / Programs, c1psl burt restore 
Entry  Fri Jan 10 14:21:19 2020, Yehonathan, Update, PSL, c1psl reboot 
Entry  Tue Jan 7 18:51:51 2020, Jon, Update, PSL, New c1psl server assembled 
Entry  Mon Nov 4 19:02:25 2019, Yehonathan, Update, PSL, Mapping the PSL electronics PSL_Wirings_-_Sheet1_(1).pdf
    Reply  Tue Dec 17 00:23:28 2019, Yehonathan, Update, PSL, Mapping the PSL electronics PSL_Wirings_-_Sheet1_(2).pdf
       Reply  Tue Dec 17 18:05:06 2019, Yehonathan, Update, PSL, Mapping the PSL electronics PSL_Wirings_-_Sheet1_(3).pdf
          Reply  Fri Dec 20 18:33:21 2019, Yehonathan, Update, PSL, Mapping the PSL electronics PSL_Wirings_-_Channel_List.pdf
             Reply  Mon Dec 23 19:30:20 2019, Yehonathan, Update, PSL, Mapping the PSL electronics 
                Reply  Wed Jan 1 04:53:11 2020, gautam, Update, PSL, Mapping the PSL electronics 
                   Reply  Wed Jan 1 16:04:37 2020, Yehonathan, Update, PSL, Mapping the PSL electronics 
Entry  Wed Dec 11 15:01:57 2019, Jon, Summary, PSL, PMC cavity ringdown measurement IMG_0101.jpg
    Reply  Thu Dec 12 19:20:43 2019, Yehonathan, Update, PSL, PMC cavity ringdown measurement IMG_0105.jpegTEK00001.PNG20191212_151642.jpg
       Reply  Fri Dec 13 12:28:43 2019, Yehonathan, Update, PSL, PMC cavity ringdown measurement Ringdown_InitialProcess.pdf
          Reply  Tue Dec 17 20:45:30 2019, rana, Update, PSL, PMC cavity ringdown measurement 
          Reply  Fri Dec 27 15:01:02 2019, Yehonathan, Update, PSL, PMC cavity ringdown measurement PDAOMResponse.pdfPMCTransmission.pdfRingdownsAndRefs.pdfTwoExponentialFitAOM0.3V.pdf
             Reply  Tue Dec 31 03:03:02 2019, gautam, Update, PSL, PMC cavity ringdown measurement 
       Reply  Mon Dec 16 18:19:42 2019, shruti, Update, PSL, PMC cavity ringdown measurement : beat-note disruption IMG_0040.jpg
Entry  Tue Dec 10 15:17:17 2019, Yehonathan, Update, PSL, PMC is locked 
    Reply  Tue Dec 10 18:27:22 2019, Yehonathan, Update, PSL, PMC is locked 
       Reply  Wed Dec 11 15:29:17 2019, Yehonathan, Update, PSL, PMC is locked 
Entry  Fri Dec 6 17:49:46 2019, rana, Summary, PEM, Jump test of seismometers: EX needs recentering Seismometers.pdfsrc.tgz
    Reply  Sun Dec 8 20:15:41 2019, rana, Summary, PEM, Jump test of seismometers: EX needs recentering seis_all_191208.pdf
       Reply  Mon Dec 9 13:08:24 2019, Yehonathan, Summary, PEM, Jump test of seismometers: EX needs recentering seis_191208.pdf
Entry  Sun Dec 8 20:27:11 2019, rana, Update, Computers, Viviana upgrade to Ubuntu 16 
Entry  Fri Dec 6 15:22:01 2019, gautam, Frogs, LSC, DAFI system revived 
Entry  Tue Oct 8 18:35:09 2019, gautam, Update, LSC, Locking prep 
    Reply  Wed Oct 9 18:15:26 2019, gautam, Update, LSC, PRMI 3f locking PRMI_1f.png
       Reply  Wed Oct 9 22:02:58 2019, gautam, Update, LSC, REFL55 whitening issue 
          Reply  Thu Oct 10 01:12:56 2019, gautam, Update, LSC, Locking studies PRFPMIstudies.png
             Reply  Wed Oct 16 11:42:17 2019, gautam, Update, LSC, Poor separation of PRCL/MICH in 3f signals sensMat.pdf
                Reply  Thu Oct 17 11:19:28 2019, gautam, Update, LSC, Locking activity last night MICH2PRCLnulling.pdfconsolidatedSensingMatrices.pdf.zip
                   Reply  Tue Oct 22 00:52:27 2019, gautam, Update, LSC, Locking updates PRMI3f_ALS_Oct21sensMat.pdf
                      Reply  Tue Oct 29 01:24:45 2019, gautam, Update, LSC, More locking updates POP22_feature.pngPRMI3f_ALS_Oct21sensMat.pdf
                         Reply  Tue Oct 29 15:13:19 2019, gautam, Update, LSC, More locking updates PRMI_lockloss.png
                            Reply  Wed Oct 30 01:27:00 2019, gautam, Update, LSC, More locking updates POP_ASS.png
                               Reply  Wed Oct 30 11:53:41 2019, gautam, Update, LSC, MICH loop shape tuning MICH_ELP.pdfMICH_ELP_TFs.pdf
                               Reply  Wed Oct 30 17:08:40 2019, gautam, Update, LSC, POP22 investigation POP22anomaly.pdf
                                  Reply  Mon Nov 4 15:29:47 2019, gautam, Update, LSC, POP signal path POPchain.pdf
                                     Reply  Mon Nov 4 16:06:58 2019, gautam, Update, LSC, POP optical path IMG_8027.JPGlensRealignment.jpgPOPrealigned.pngPOPdither.pngPRMfixed.png
                                        Reply  Tue Nov 5 11:52:27 2019, gautam, Update, LSC, Locking notes PRMI3f_ALS_Nov4sensMat.pdf
                                           Reply  Wed Nov 6 02:08:48 2019, gautam, Update, LSC, Locking updates 
                                              Reply  Wed Nov 6 17:05:45 2019, gautam, Update, LSC, CARM calibration CARMscan.pdfCARMcalib.pdfscan.hdf5.zip
                                              Reply  Wed Nov 6 17:45:34 2019, gautam, Update, LSC, ~ 
                                                 Reply  Mon Nov 18 21:04:38 2019, gautam, Update, LSC, Locking - some ideas 
                                                    Reply  Wed Nov 20 01:07:18 2019, gautam, Update, LSC, Locking - progress PRFPMI.png
                                                       Reply  Wed Nov 20 12:14:17 2019, gautam, Update, LSC, Locking - progress TRX_TRY_comparison.pdf
                                                          Reply  Wed Nov 20 17:20:24 2019, Yehonathan, Update, LSC, QPD Investigation 
                                                             Reply  Wed Nov 20 17:52:00 2019, gautam, Update, LSC, QPD MEDM screen update newLookQPD.pngTRX_TRY_comparison.pdfIMG_8186.JPG
                                                                Reply  Wed Nov 20 21:29:28 2019, gautam, Update, LSC, PRG ~13 PRG13.pdf
                                                                   Reply  Fri Nov 22 00:54:14 2019, gautam, Update, LSC, locking notes ALSnoiseIncrease.pdf
                                                                      Reply  Mon Nov 25 19:11:22 2019, gautam, Update, LSC, ALS noise re-look ALSnoise.pdf
                                                                         Reply  Wed Nov 27 23:24:01 2019, gautam, Update, LSC, No shaking but no inspiration either 
                                                                            Reply  Sun Dec 1 13:38:48 2019, rana, Update, LSC, No shaking but no inspiration either 
                                                                               Reply  Tue Dec 3 00:03:57 2019, gautam, Update, LSC, Green ALS also shows elevated noise with high arm buildup ALSnoiseIncrease_greenBeat.pdf
                                                                                  Reply  Wed Dec 4 19:54:27 2019, gautam, Update, LSC, A look to the past DRFPMI_2016March.pdf
                                                                                     Reply  Thu Dec 5 01:54:39 2019, gautam, Update, LSC, Partial CM board path engaged AOengaged.pdf
                                                                                        Reply  Fri Dec 6 00:02:48 2019, gautam, Update, LSC, What is the correct way to set the 3f offsets? 
                                     Reply  Fri Nov 15 12:08:04 2019, gautam, Update, LSC, POPDC whitening board 
                         Reply  Tue Oct 29 17:40:48 2019, gautam, Update, LSC, More locking updates broadSweep.pdfzoomSweep.pdf
Entry  Thu Dec 5 18:15:01 2019, gautam, Update, Optical Levers, ITM, PRM and BS Oplevs re-centered 
Entry  Thu Dec 5 15:09:50 2019, gautam, Update, CDS, c1oaf crashed c1lsc SCYerrors.pngCDSnormal.png
Entry  Thu Dec 5 14:54:15 2019, gautam, Update, General, Symlink to SRmeasure and AGmeasure 
Entry  Thu Dec 5 08:44:44 2019, Gavin, Update, Loss Measurement, Q Measurements of Test Masses 20191205_132158.jpg
Entry  Fri Jun 8 14:40:55 2018, c1lsc, Update, CDS, i am dead 31.png
    Reply  Fri Jun 8 20:15:08 2018, gautam, Update, CDS, Reboot script 31.png
       Reply  Mon Jun 11 18:49:06 2018, gautam, Update, CDS, c1lsc dead again 36.png
       Reply  Wed Dec 4 09:11:42 2019, Yehonathan, Update, CDS, Reboot script medmScreen11.ps
          Reply  Wed Dec 4 12:13:10 2019, gautam, Update, CDS, Reboot script 
Entry  Wed Dec 4 08:54:07 2019, Yehonathan, Update, IMC, Mirror analog shaking 
Entry  Mon Dec 2 00:27:20 2019, gautam, Update, ALS, Green ALS resurrection ALSnoiseComparison.pdfALS_TR_RIN.pdfGreemAM.pdf
    Reply  Mon Dec 2 18:20:29 2019, gautam, Update, ALS, EY uPDH post mixer LPF EY_uPDH_LPF.pdfEY_uPDH_OLTF.pdf
       Reply  Mon Dec 2 20:18:18 2019, rana, Update, ALS, EY uPDH post mixer LPF 
          Reply  Tue Dec 3 18:15:42 2019, gautam, Update, ALS, EY uPDH post mixer LPF 
             Reply  Tue Dec 3 21:28:24 2019, gautam, Update, ALS, EY uPDH post mixer LPF uPDH.pdf
       Reply  Tue Dec 3 00:10:15 2019, Koji, Update, ALS, EY uPDH post mixer LPF 
          Reply  Tue Dec 3 00:51:25 2019, gautam, Update, ALS, EY uPDH post mixer LPF 
Entry  Tue Dec 3 20:32:37 2019, rana, Omnistructure, DAQ, NDS2 situation getData.pychanlist.txt
Entry  Wed Nov 27 18:51:22 2019, Gavin Wallace, Update, IMC, Q Measurement of Test Masses 
    Reply  Tue Dec 3 14:52:13 2019, rana, Update, IMC, Q Measurement of Test Masses 
Entry  Mon Dec 2 23:01:47 2019, gautam, Update, CDS, Frequent DTT crashes on pianosa DTTerrorLog.tgz
Entry  Wed Nov 27 17:51:52 2019, gautam, Update, Wiener, MCL FF status MCL_FF.pdfPRC_FF.pdf
Entry  Tue Nov 26 17:07:41 2019, gautam, Update, LSC, POX / POY calibration POX_POY_sensorNoise.pdfALSnoise_20191125.pdf
    Reply  Tue Nov 26 18:16:08 2019, rana, Update, LSC, POX / POY calibration 
       Reply  Wed Nov 27 12:16:52 2019, gautam, Update, LSC, ITMX and ITMY OSEMs with low and high circulating power ITMXshadowSensors.pdfITMYshadowSensors.pdf
          Reply  Wed Nov 27 13:14:02 2019, rana, Update, LSC, ITMX and ITMY OSEMs with low and high circulating power 
             Reply  Wed Nov 27 16:10:29 2019, gautam, Update, LSC, AOM reconnected 
Entry  Tue Nov 26 13:33:33 2019, Yehonathan, Update, Cameras, MC2 Camera rotated by 90 degrees MC2AnalogCameraAfter.jpgMC2AnalogCameraBefore.jpg
Entry  Mon Nov 25 22:10:26 2019, shruti, Update, NoiseBudget, Diagnostics  LSC.pdfITMY.pdfITMX_L.pdf
Entry  Thu Nov 21 12:46:22 2019, gautam, Update, LSC, CM board study YARM_CMslow.pdf
    Reply  Thu Nov 21 13:14:33 2019, Koji, Update, LSC, CM board study 
       Reply  Thu Nov 21 19:08:58 2019, gautam, Update, LSC, High BW lock of Y arm length to PSL frequency highBW_POY.pdfCM_UGF.pdfIN2_ACcoupling.pdf
Entry  Tue Oct 8 08:08:18 2019, gautam, Update, PEM, PEM BLRMS anomaly PEManomaly.png
    Reply  Wed Oct 23 11:49:21 2019, gautam, Update, PEM, PEM BLRMS anomaly seisAll_20191021.pdfspecGrams.zip
       Reply  Thu Oct 24 18:37:15 2019, gautam, Update, PEM, T240 checkout 
          Reply  Tue Nov 5 12:37:50 2019, gautam, Update, PEM, T240 interface unit pulled out T240_recenter.pdfffPotential.pdf
             Reply  Wed Nov 13 19:34:45 2019, gautam, Update, PEM, Follow-up on seismometer discussion seisAll_20191111.pdfffPotential.pdf
                Reply  Wed Nov 13 20:15:56 2019, rana, Update, PEM, Follow-up on seismometer discussion 
                   Reply  Wed Nov 13 23:40:15 2019, gautam, Update, PEM, Follow-up on seismometer discussion seisAll_20191111_1Hz.pdf
                      Reply  Thu Nov 14 12:11:04 2019, rana, Update, PEM, Follow-up on seismometer discussion 
                      Reply  Fri Nov 15 00:18:41 2019, rana, Update, PEM, Follow-up on seismometer discussion MCshake.pdf
                         Reply  Fri Nov 15 12:16:48 2019, gautam, Update, PEM, Follow-up on seismometer discussion BS_ZspecGram.pdf.zip
                            Reply  Mon Nov 18 14:32:53 2019, gautam, Update, PEM, Follow-up on seismometer discussion 
                               Reply  Tue Nov 19 21:53:57 2019, gautam, Update, PEM, Follow-up on seismometer discussion seisxSpec.pdf
Entry  Tue Nov 19 15:08:48 2019, gautam, Update, CDS, Vertex models rebooted armSat.png
Entry  Fri Nov 15 18:59:08 2019, rana, Update, Computers, ZITA: started upgrade from Ubuntu 14 LTS to 18 LTS 
    Reply  Mon Nov 18 16:32:15 2019, gautam, Update, Computers, ZITA: started upgrade from Ubuntu 14 LTS to 18 LTS 
Entry  Mon Nov 4 11:41:28 2019, shruti, Update, Computer Scripts / Programs, Epics installed on donatella 
    Reply  Thu Nov 7 17:55:37 2019, shruti, Update, Computer Scripts / Programs, Python packages on donatella 
Entry  Fri Oct 18 20:21:33 2019, shruti, Update, ALS, AM measurement attempt at X end 
    Reply  Thu Nov 7 17:46:10 2019, shruti, Update, ALS, AM measurement at X end AMTF20191107.png
Entry  Mon Sep 12 23:54:10 2011, kiwamu, Update, IOO, EOM resonant box installed EOM.pngbefore.pngafter.png
    Reply  Wed Nov 6 20:34:28 2019, Koji, Update, IOO, Power combiner loss (EOM resonant box installed) power_combiner.pdf
Entry  Wed Nov 6 19:26:57 2019, gautam, Update, PSL, Some PSL cable admin PSLcableAdmin.jpg
Entry  Sat Nov 2 16:36:55 2019, Yehonathan, Update, PSL, Up to date sketch of the 1x1 and 1x2 Eurocrates 1x1_1X2_Eurocrates_with_links.pdf
    Reply  Sat Nov 2 17:08:34 2019, Yehonathan, Update, PSL, Up to date sketch of the 1x1 and 1x2 Eurocrates 
       Reply  Mon Nov 4 13:26:04 2019, Yehonathan, Update, PSL, Up to date sketch of the 1x1 and 1x2 Eurocrates 
Entry  Thu Oct 31 10:44:40 2019, gautam, Update, PSL, PMC re-locked 
Entry  Wed Oct 30 19:20:27 2019, gautam, Update, SUS, PRM suspension issues PRMUL.pdfPRMnormal.pdfPRM-Sensors_noise.pdfPRMsuspensionWonky.png
    Reply  Wed Oct 30 23:12:27 2019, Koji, Update, SUS, PRM suspension issues 
Entry  Mon Oct 21 12:25:46 2019, gautam, Update, ALS, DFD electronics checkout ALSnoiseAnomaly.pdfDFDcalib.pdfspectra.pdfPTgains.pdf
    Reply  Tue Oct 22 15:32:15 2019, gautam, Update, ALS, EX uPDH electronics checkout uPDH_X_OLTFs.pdf
       Reply  Wed Oct 23 10:23:26 2019, rana, Update, ALS, EX uPDH electronics checkout 
          Reply  Wed Oct 23 11:11:01 2019, gautam, Update, ALS, EX uPDH electronics checkout 
    Reply  Fri Oct 25 01:04:49 2019, gautam, Update, ALS, ALS electronics chain was saturating 
       Reply  Mon Oct 28 23:20:11 2019, gautam, Update, ALS, ALS power budget 
Entry  Thu Oct 24 11:58:16 2019, gautam, Update, ASC, PRC angular feedforward ffPotential.pdf
Entry  Wed Oct 23 18:40:58 2019, gautam, Update, CDS, another round of vertex FE reboots 
Entry  Thu Oct 17 16:49:53 2019, gautam, Update, ASC, PRMI ASC - first pass PRMI_ASC.pdf
    Reply  Tue Oct 22 17:35:30 2019, gautam, Update, ASC, PRMI ASC - first pass originalPOP_QPD.pngPOP_QPD_modified.png
       Reply  Wed Oct 23 11:14:21 2019, gautam, Update, ASC, PRMI ASC with QPD signals normalized. PRMI_ASC_normalization.pdfPRMI_ASC_Oct22.pdf
Entry  Fri Oct 18 17:35:07 2019, gautam, Update, SUS, ETMX sat box disconnected 
    Reply  Mon Oct 21 16:02:21 2019, gautam, Update, SUS, ETMX over the weekend filteredData.pdf
Entry  Fri Oct 18 18:13:55 2019, Koji, Update, safety, Laser interlock looks OK 
    Reply  Mon Oct 21 11:44:19 2019, gautam, Update, safety, Interlock reconnected to Innolight controller 
Entry  Thu Oct 17 12:34:51 2019, gautam, Update, General, Daytime wishlist DriftingTTs.pngFSSweirdness.png
Entry  Mon Oct 14 17:24:28 2019, gautam, Update, General, Workstation computers taken off UPS (temporarily) 
    Reply  Tue Oct 15 17:22:26 2019, gautam, Update, General, Workstation computers back on UPS  
Entry  Thu Oct 10 23:36:02 2019, Koji, Update, General, Wednesday cleaning work P_20191009_165624.jpgP_20191009_164740.jpgP_20191010_233631.jpg
    Reply  Tue Oct 15 17:19:38 2019, Koji, Update, General, Wednesday cleaning work P_20191015_161711.jpeg
Entry  Fri Sep 20 12:55:02 2019, gautam, Update, CDS, c1iscaux testing 
    Reply  Mon Sep 23 10:49:34 2019, rana, Update, CDS, c1iscaux testing 
    Reply  Wed Sep 25 20:10:13 2019, Koji, Update, CDS, c1iscaux testing testDetectMons_190925.pngtestIPPOS_190925.png
       Reply  Thu Sep 26 20:09:40 2019, Koji, Update, CDS, c1iscaux testing Wht1.pdfWht2.pdfWht3.pdfWht4.pdflock.png
          Reply  Fri Sep 27 15:59:53 2019, gautam, Update, CDS, c1iscaux testing 
          Reply  Wed Oct 2 01:11:40 2019, Koji, Update, CDS, c1iscaux testing 8x
             Reply  Fri Oct 4 01:57:09 2019, Koji, Update, CDS, c1iscaux testing P_20191003_172956_vHDR_On.jpgTF.pdfPSD.pdf191003_AA_Filter.zip
                Reply  Sat Oct 5 00:03:21 2019, Koji, Update, CDS, c1iscaux testing REFL1_GAIN1.pdfREFL1_GAIN2.pdfREFL2_GAIN1.pdfREFL2_GAIN2.pdf
                   Reply  Tue Oct 8 03:32:42 2019, Koji, Update, CDS, CM servo board testing 7x
                      Reply  Tue Oct 8 17:59:29 2019, Koji, Update, CDS, CM servo board testing (portal) 6x
                         Reply  Tue Oct 8 18:42:39 2019, Koji, Update, CDS, CM servo board testing boosts.pdf
                            Reply  Mon Oct 14 16:06:28 2019, Koji, Update, CDS, CM servo board testing pole_zero_filter.pdf
                               Reply  Mon Oct 14 16:19:30 2019, Koji, Update, CDS, CM servo board testing testb2.pdf
                                  Reply  Mon Oct 14 16:25:03 2019, Koji, Update, CDS, CM servo board testing servo_out.pdf
                                     Reply  Mon Oct 14 16:34:42 2019, Koji, Update, CDS, CM servo board testing in12_output_offset.pdfin12_input_offset.pdfin12_input_offset2.pdf
                                        Reply  Mon Oct 14 17:32:28 2019, Koji, Update, CDS, Portal Elog entry for the recent CM servo board tests CM_Servo_Diagram.png
                         Reply  Tue Oct 8 20:23:03 2019, gautam, Update, CDS, c1iscaux testing 
    Reply  Mon Sep 30 11:20:43 2019, gautam, Update, CDS, c1iscaux testing - CM board code updated CMsoftTest.png
       Reply  Mon Sep 30 15:51:59 2019, gautam, Update, CDS, c1iscaux - some admin 
Entry  Thu Oct 10 22:11:53 2019, gautam, Update, LSC, Trans QPD checkout EY_table_20191010.jpegdarkNoise.pdf
Entry  Mon Oct 7 14:51:20 2019, aaron, Update, Electronics, WFS head RF measurements WFShead_response.pdf
    Reply  Mon Oct 7 19:50:33 2019, gautam, Update, IOO, IMC locking not working after this work IMCflaky.pngIMG_8015.JPG
       Reply  Tue Oct 8 10:29:19 2019, gautam, Update, IOO, MC Transmission scan MC2_transmission_scatter.pdftransmissionMaps.pdfcorrelStructure.pdf
       Reply  Tue Oct 8 16:54:56 2019, rana, Update, IOO, IMC locking not working after this work 
    Reply  Tue Oct 8 16:00:06 2019, aaron, Update, Electronics, WFS head RF measurements WFS_ACresponse.pdfWFS_DCresponse.pdf
       Reply  Wed Oct 9 12:15:05 2019, rana, Update, Electronics, WFS head RF measurements 
Entry  Tue Sep 10 15:41:37 2019, aaron, Update, IOO, WFS measurements Screenshot_from_2019-09-10_18-51-28.pngmctrend_190910.png
    Reply  Wed Sep 11 10:26:56 2019, aaron, Update, IOO, WFS measurements 
       Reply  Wed Sep 11 14:37:43 2019, aaron, Update, IOO, WFS measurements 20190911_WFS.jpg20190911_WFS_2.jpg
          Reply  Thu Sep 12 12:42:31 2019, aaron, Update, IOO, WFS measurements WFS2_TFs.pdfD755499D-9FDF-4E2B-BFC1-016B459DD35D.jpeg
             Reply  Fri Sep 13 10:36:03 2019, aaron, Update, IOO, WFS measurements TF-.pngWFS2_TFs.pdf
                Reply  Mon Sep 16 12:38:59 2019, aaron, Update, IOO, WFS measurements 
                Reply  Thu Oct 3 11:38:35 2019, aaron, Update, IOO, WFS measurements 
          Reply  Mon Sep 30 13:20:55 2019, aaron, Update, IOO, shot noise measurement 
       Reply  Fri Sep 13 10:53:40 2019, aaron, Update, IOO, WFS loop measurements 
          Reply  Mon Sep 16 05:08:04 2019, rana, Update, IOO, WFS loop measurements LSCsensingMatrix.ipynbASCsensingMatrix.ipynb
             Reply  Mon Sep 16 11:55:58 2019, rika, Update, IOO, WFS loop measurements 
                Reply  Tue Sep 17 09:41:48 2019, gautam, Update, IOO, WFS loop measurements 
                Reply  Tue Sep 17 10:47:44 2019, rika, Update, IOO, WFS loop measurements MC2.pdf
                   Reply  Wed Sep 18 14:45:52 2019, rika, Update, IOO, WFS loop measurements Screenshot_from_2019-09-18_18-15-34.png
             Reply  Tue Sep 17 10:34:48 2019, aaron, Update, IOO, WFS loop measurements 
                Reply  Tue Oct 8 20:39:42 2019, aaron, Update, IOO, WFS loop measurements 
                   Reply  Wed Oct 9 09:37:28 2019, aaron, Update, IOO, WFS loop measurements 
Entry  Fri Oct 4 22:22:03 2019, gautam, Update, CDS, Final incarnation of latch.py LatchLogic.pdf
    Reply  Tue Oct 8 03:19:14 2019, Koji, Update, CDS, Final incarnation of latch.py 
Entry  Fri Oct 4 00:32:24 2019, gautam, Update, ALS, More locking updates ALS_singleArm.pngALS_OOL_20191003.pdf
    Reply  Sat Oct 5 21:26:34 2019, gautam, Update, ALS, Y-end green alignment tweaked ALSY_alignment.pngALSY_OOL.pdf
       Reply  Sun Oct 6 15:23:27 2019, gautam, Update, ALS, Arm control using error signals achieved ALSY_20191006.pdftransitionIRALS.pngarms_ALS.pdf
Entry  Thu Oct 3 12:08:47 2019, gautam, Update, General, Make the Jenne-laser setup fiber-coupled PDFR_tabletop.pdfIMG_8014.JPG
    Reply  Thu Oct 3 14:32:37 2019, rana, Update, General, Mak