  17255   Thu Nov 10 20:46:32 2022 ranaUpdateASCIMC WFS servo diagnosisTo check out the bandwidths and
cross-coupling in the WFS loops, I made a
script (attached) to step the offsets around,
 toggleWFSoffsets.pyimc-wfs-steps.pdf 
  17272   Wed Nov 16 12:53:36 2022 ranaUpdateASCIMC WFS ongoingIn the middle of aportioning gains and
signs in the IMC WFS screen, so beware. More
updates soon.
  
  17288   Fri Nov 18 23:21:54 2022 ranaUpdateASCIMC WFS ongoingOn Wednesday, I did some rework of the
MC WFS gains. I think it should still work
as before as long as the overall input gain
  
  17311   Thu Nov 24 15:37:45 2022 AnchalUpdateASCIMC WFS output matrix diagonalization effortI tried following the steps and the method
I was using converged to same output matrix
upto 2 decimal points but there is still
 WFS_Step_DCResponses_Offsets_Marked.png 
  13157   Tue Aug 1 19:23:06 2017 ranaUpdateALSX - arm alignmentRana, Naomi

We dither locked the X arm and
then aligned the green beam to it using the
  
  13177   Wed Aug 9 12:35:47 2017 gautamUpdateALSFiber ALSLast week, we were talking about reviving
the Fiber ALS box. Right now, it's not
in great shape. Some changes to be made:
 IMG_3942.JPG 
  13180   Wed Aug 9 19:21:18 2017 gautamUpdateALSALS recoverySummary:

Between frequent MC1 excursions,
I worked on ALS recovery today. Attachment
 ALS_oolSpec.pdf 
  13204   Mon Aug 14 16:24:09 2017 gautamUpdateALSFiber ALSToday, I borrowed the fiber microscope
from Johannes and took a look at the fibers
coupled to the PDs. The PD labelled "
 IMG_7471.JPGIMG_7472.JPGIMG_7473.JPGIMG_7474.JPG 
  13222   Wed Aug 16 20:24:23 2017 gautamUpdateALSFiber ALSToday, with Johannes' help, I cleaned
the fiber tips of the photodiodes. The effect
of the cleaning was dramatic - see Attachments
 IMG_7476.JPGIMG_7477.JPGIMG_7478.JPGIMG_7479.JPG 
  13229   Fri Aug 18 23:59:53 2017 gautamUpdateALSX Arm ALS lock[ericq, gautam]


I was just getting the
IFO aligned, and single arm lock going, when
  
  13230   Sat Aug 19 01:35:08 2017 ericqUpdateALSX Arm ALS lockMy motivation tonight was to get an up-to-date
spectrum of a calibrated measurement
of the out-of-loop displacement of an arm
 ALS_comparison.pdf 
  13237   Mon Aug 21 23:38:55 2017 gautamUpdateALSALS out-of-loop noiseI worked a little bit on the Y arm ALS
today. 


Started by locking the
 ALS_21082017.pdf 
  13238   Tue Aug 22 02:19:11 2017 gautamUpdateALSALS OLTFsAttachment #1 shows the
results of my measurements tonight (SR785
data in Attachment #2).
 ALS_OLTFs.pdfALS_OLTF_Aug2017.zip 
  13244   Tue Aug 22 23:27:14 2017 ranaUpdateALSALS OLTFsDidn't someone look at what the OLG
req. should be for these servos at some point?
I wonder if we can make a parallel digital
  
  13246   Wed Aug 23 17:22:36 2017 gautamUpdateALSFiber ALS - reinstalledI completed the revamp of the box, and
re-installed the box on the PSL table today.
I think it would be ideal to install this
  
  13254   Fri Aug 25 15:54:14 2017 gautamUpdateALSFiber ALS noise measurement[Kira, gautam]

Attachment #1 - Photo
of the revamped beat setup. The top panel
 IMG_7497.JPGFOL_schematic.pdf20170825_IR_ALS.pdf 
  13255   Fri Aug 25 17:11:07 2017 ranaUpdateALSFiber ALS noise measurementIs it better to mount the box in the PSL
under the existing shelf, or in a nearby
PSL rack?
  
  13257   Sun Aug 27 11:57:31 2017 ranaUpdateALSFiber ALS noise measurementIt seems like the main contribution to
the RMS comes from the high frequency bump.
When using the ALS loop to lock the arm to
  
  13266   Tue Aug 29 02:08:39 2017 gautamUpdateALSFiber ALS noise measurementI was having a chat with EricQ about this
today, just noting some points from our discussion
down here so that I remember to look into
  
  13288   Fri Sep 1 19:15:40 2017 gautamUpdateALSFiber ALS noise measurementSummary:

I
did some work today to see if I could use
 IR_ALS_noise.pdf 
  13325   Thu Sep 21 01:32:00 2017 gautamUpdateALSAUX X Innolight AM measurement running[rana,gautam]

We set up a measurement of the
AUX X laser AM today. Some notes:
 Innolight_AM.pdfInnolight_AM.tar.gzIMG_7599.JPG20170921_203741_TFAG4395A_21-09-2017_115547_FourSquare.pdf 
  13326   Thu Sep 21 01:55:16 2017 ranaUpdateALSX End table of ShameImage #1: No - we do not use magnetic mounts
for beam dumps. Use a real clamp. It has
to be rigid. "its not going anywhere"
 20170921_003143.jpg20170921_002430.jpg20170921_002243.jpg20170921_001906.jpg 
  13327   Thu Sep 21 15:23:04 2017 gautamOmnistructureALSLong cable from LSC->IOO[steve,gautam]

We laid out a 45m long BNC cable
from the LSC rack to the IOO rack via overhead
  
  13333   Tue Sep 26 19:10:13 2017 gautamUpdateALSFiber ALS setup neatened[steve, gautam]

The Fiber ALS box has been installed
on the existing shelf on the PSL table. We
 IMG_7605.JPG 
  13335   Wed Sep 27 00:20:19 2017 gautamUpdateALSMore AM sweepsAttachment #1: Result
of AM sweeps with EX laser crystal at nominal
operating temperature ~ 31.75 C.
 TFAG4395A_26-09-2017_202344_FourSquare.pdflowTemp.tgzTFAG4395A_26-09-2017_231630_FourSquare.pdfhighTemp.tgz 
  13337   Wed Sep 27 23:44:45 2017 gautamUpdateALSProposed PM measurement setupAttachment #1 is
a sketch of the proposed setup to measure
the PM response of the EX NPRO. Previously,
 IMG_7609.JPG 
  13346   Fri Sep 29 11:16:52 2017 SteveUpdateALSY End table correctedThe first Faraday isolater rejected beam
path from the NPRO is fixed.

 
 ETMYf1.jpg 
  13366   Fri Oct 6 17:08:09 2017 SteveUpdateALSX End table beam traps correctedThere are no more double sided tape on
this table.

 
 c1.jpgc2.jpgc3.jpgc4.jpg 
  13502   Thu Jan 4 12:46:27 2018 gautamUpdateALSFiber ALS assayAttachment
#1 is the updated
 FiberALS.pdfFiberALS.svg.zip 
  13519   Tue Jan 9 21:38:00 2018 gautamUpdateALSALS recovery
Aligned IFO to IR.

Ran
dither alignment to maximize arm transmission.
Centered
Oplev reflections onto their respective QPDs
 GreenLockStability.pngALS_OLTFs_20180109.pdfALS_OLTF_data_20180109.tar.bz2 
  13531   Thu Jan 11 14:22:40 2018 gautamUpdateALSFiber ALS assayI did a cursory check of the ALS signal
chain in preparation for commissioning the
IR ALS system. The main elements of this
  
  13534   Thu Jan 11 20:51:20 2018 gautamUpdateALSFiber ALS assayAfter labeling cables I would disconnect,
I pulled the box out of the LSC rack. Attachment
#1 is a picture of the insides of the box
 IMG_5112.JPG 
  13552   Tue Jan 16 21:50:53 2018 gautamUpdateALSFiber ALS assayWith Johannes' help, I re-installed
the box in the LSC electronics rack. In the
end, I couldn't find a good solution
  
  13557   Thu Jan 18 00:35:00 2018 gautamUpdateALSFiber ALS assaySummary:

I
am facing two problems:
 IR_ALS_20180118.pdfC2B4C1DD-6528-4067-9C13-6BD248629AD6.MOV 
  13559   Fri Jan 19 11:34:21 2018 gautamUpdateALSFiber ALS assayI swapped the inputs to the ZHL-3A at the
PSL table - so now the X beat RF signals
from the beat mouth are going through what
 IR_ALS_20180119.pdf 
  13562   Fri Jan 19 23:04:11 2018 gautamUpdateALSFiber ALS assay[rana, kevin, udit, gautam]

quick notes of some discussions
we had today:
  
  13571   Wed Jan 24 00:33:31 2018 gautamUpdateALSFiber ALS assayI did some work on the PSL table today.
Main
 IMG_6866.JPG 
  13573   Wed Jan 24 00:58:59 2018 gautamUpdateALSX Green PDH modulation depthOn Friday, while Udit and I were doing
some characterization of the EX+PSL IR beat
at the LSC rack, I noticed that there were
  
  13574   Wed Jan 24 10:45:14 2018 gautamUpdateALSFiber ALS assayI was looking into the physics of polarization
maintaining fibers, and then I was trying
to remember whether the fibers we use are
  
  13583   Thu Jan 25 13:18:41 2018 gautamUpdateALSFiber ALS assayI was looking at this a little more closely.
As I understand it, the purpose of the audio
differential IF amplifier is:
 preampProposed.pdf 
  13586   Thu Jan 25 23:59:14 2018 gautamUpdateALSFiber ALS assayI tried to couple the PSL pickoff into
the fiber today for several hours, but got
nowhere really, achieved a maximum coupling
  
  13587   Fri Jan 26 20:03:09 2018 gautamUpdateALSFiber ALS assayI think part of the problem was that the
rejected beam from the PBS was not really
very Gaussian - looking at the spot on the
  
  13591   Wed Jan 31 15:45:22 2018 gautamUpdateALSFiber ALS assayAttachment #1 shows the current situation
of the PSL table IR pickoff. It isn't
the greatest photo but it's hard to get
 IMG_6875.JPG 
  13593   Wed Jan 31 16:29:42 2018 gautamUpdateALSModulation depthsI used the Beat
Mouth to make a quick
 PMCmodDepth.pdfXPDH.pdf 
  13594   Wed Jan 31 16:33:53 2018 gautamUpdateALSALS electronics at LSC rack[steve,
gautam]

We installed some 
  
  13595   Wed Jan 31 22:32:11 2018 gautamUpdateALSALS signal chain + power budgetSummary:

 FiberALS_PowerBudget.pdfpreampProposed.pdf 
  13596   Thu Feb 1 01:24:56 2018 gautamUpdateALSD0902745 revamp underwayI effected the change to the Audio IF preamp
stage on channels 3 and 4 (Xarm and Yarm
respectively) using the resistors Steve ordered
 PSLinterlock.png 
  13597   Thu Feb 1 15:31:12 2018 gautamUpdateALSALS signal chain + power budgetSummary:

A
  
  13599   Fri Feb 2 00:26:34 2018 gautamUpdateALSD0902745 revamp underwayI saw some interesting behaviour of the
Audio IF amplifier stage on the demod board
today, by accident. I was testing the board
  
  13600   Fri Feb 2 13:16:55 2018 gautamUpdateALSALS signals whitening switchingWhile setting up for this measurement,
I noticed something odd with the whitening
switching for the ALS channels. For the usual
 ALS_whitening_switching.pdfALS_whitening_switching_works.pdf 