40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 330 of 336  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  15837   Wed Feb 24 10:09:16 2021 yehonathanUpdateSUSOSEM testing for SOSsYes, my phone camera mirrored the image.
Sorry for the confusion.

I see you already uploaded the
  
  16062   Wed Apr 21 11:09:57 2021 yehonathanUpdatePSLLaser amplifierI went to the TCS lab to take a look at
the chillers lying around. I spotted two
chillers:
 20210420_171606.jpg20210420_171621.jpg20210420_171611.jpg20210420_171629.jpg20210420_171702.jpg 
  16253   Wed Jul 21 18:08:35 2021 yehonathanUpdateLoss MeasurementLoss measurement{Gautam, Yehonathan, Anchal, Paco}

We prepared for the loss measurement
using DC reflection method. We did the following
  
  16371   Fri Oct 1 14:25:27 2021 yehonathanSummarySUSPRM and BS Angular Actuation transfer function magnitude measurements{Paco, Yehonathan, Hang}

We measured the sensing PRMI sensing
matrix. Attachment 1 shows the results, the
 MICH_PRM_-0.34.pngMICH_PRM_-0.1.png 
  16779   Thu Apr 14 11:52:57 2022 yehonathanSummaryBHDPart IIa of BHR upgrade - POY11 debugging{JC, Paco, Yehonathan, Ian}

POY lens was moved to infront of
the POY steering mirror to make the POU beam
 Screenshot_2022-04-14_15-53-39.pngPXL_20220414_220616875.jpg 
  16799   Thu Apr 21 18:18:42 2022 yehonathanUpdateBHDPOX Alignment{Yehonathan, Paco}

BS, ITMX and ETMX were aligned
to get flashing in the X arm.
 POX11_alignment.png 
  14825   Fri Aug 2 17:07:33 2019 yehonathan, gautamUpdateLoss Measurement We run a loss measurement on the Y arm
with 50 repetitions.
  
  12825   Mon Feb 13 17:19:41 2017 yinziConfiguration configuring ethernet for raspberry piGautam and I were able to get the Raspberry
Pi up and running today, including being
able to ssh into it from the control room.
 Screen_Shot_2017-02-13_at_5.11.52_PM.png 
  14205   Fri Sep 21 09:59:09 2018 yukiConfigurationASCY end table upgrade plan[Yuki, Gautam]

Attachments #1 is the current setup
of AUX Y Green locking and it has
 Pic_CurrentSetup_AUXYgreen.jpegModeMatchingSolution_Current.pdfModeMatchingSolution_Current_Magnified.pdfModeMatchingSolution_Optimized.pdfModeMatchingSolution_Optimized_Magnified.pdf 
  14211   Sun Sep 23 17:38:48 2018 yukiUpdateASCAlignment of AUX Y end green beam was recovered[ Yuki, Koji, Gautam ]

An alignment of AUX Y end green
beam was bad. With Koji and Gautam's
  
  14212   Sun Sep 23 19:32:23 2018 yukiConfigurationASCY end table upgrade plan[ Yuki, Gautam ]

The setup I designed before has
abrupt gouy phase shift between two steering
 Pic_NewSetup0923_AUXYgreen.jpegModeMatchingSolution_Result.pdfModeMatchingSolution_Magnified_0923.jpgpic0923_1.jpgpic0923_2.jpg 
  14214   Mon Sep 24 11:09:05 2018 yukiConfigurationASCY end table upgrade plan[ Yuki, Steve ]

With Steve's help, we checked
a new lens can be set soon after dichroic
 pic0924_1.jpg 
  14216   Tue Sep 25 18:08:50 2018 yukiConfigurationASCY end table upgrade plan[ Yuki, Gautam ]

We want to remotely control steeing
PZT mirrors so its driver is needed.
  
  14218   Thu Sep 27 14:02:55 2018 yukiConfigurationASCPZT driver board verification[ Yuki, Gautam ]

I fixed the input terminal that
had been off, and made sure PZT driver
 PZTdriverSimulationDiagram.pdfPZTdriverSimulationResult.pdfPZTdriverPerformanceCheck_ResultOUT.pdfPZTdriverPerformanceCheck_ResultMON.pdfPZTdriver.asc 
  14219   Sun Sep 30 20:14:51 2018 yukiConfigurationASCQPD calibration[ Yuki, Gautam, Steve ]

Results:
I calibrated a QPD (D1600079, V1009)
 QPDcalibrationXaxis.pdfQPDcalibrationYaxis.pdf 
  14221   Mon Oct 1 13:33:55 2018 yukiConfigurationASCQPD calibration


Quote:


 Pic_QPDcalibration.jpg 
  14224   Tue Oct 2 18:50:53 2018 yukiConfigurationASCPZT mirror calibration[ Yuki, Gautam ]

I calibrated PZT mirrors. The ROUGH
result was attached. (Note that some errors and
 PZTM1calibrationCH2.pdfPZTM1calibrationCH1.pdfPZTM2calibrationCH2.pdfPZTM2calibrationCH1.pdf 
  14226   Wed Oct 3 14:24:40 2018 yukiConfigurationASCY end table upgrade planInterim Procedure Report:

Purpose

The current setup of AUX Y-arm
  
  14227   Wed Oct 3 18:15:34 2018 yukiConfigurationASCAI board improvement[ Yuki, Gautam ]

I improved Anti-Imaging board (D000186-Rev.D),
which will be put between DAC port and
 TF_AIboard.pdf 
  14228   Thu Oct 4 00:44:50 2018 yukiConfigurationASCAI board improvement[ Yuki, Gautam ]

I made a cable which connects DAC
port (40 pins) and AI board (25 pins). I
  
  14230   Thu Oct 4 22:15:30 2018 yukiConfigurationASCY-end table upgradeBefore changing setup at Y-end table, I
measured the status value of the former setup
as follows. These values will be compared
 AUXYGreenLock20180921.jpgPic_FormerSetup.jpegPic_CurrentSetup1004.jpg 
  14232   Fri Oct 5 17:32:38 2018 yukiConfigurationASCY-end table upgradeI measured it with the wrong setting of
a powermeter. The correct ones are here:


beam power going into doubling
  
  14234   Fri Oct 5 22:49:22 2018 yukiConfigurationASCY-end table upgradeI designed a new layout. It has good mode-matching
efficiency, reasonable sensitivity to component
positions, good Gouy phase separation. I'm
  
  14236   Sun Oct 7 22:30:42 2018 yukiConfigurationLSCYarm Green locking was recoveredI finished installation of optics in the
Y-end and recovered green locking. Current
ALS-TRY_OUTPUT is about 0.25, which is lower
 Pic_NewLayout1007.jpgYendGreenModeMatching.zip 
  14237   Mon Oct 8 00:46:35 2018 yukiConfigurationASCY-end table upgrade


Quote:


  
  14240   Tue Oct 9 23:03:43 2018 yukiConfigurationLSCYarm Green locking was recovered[ Yuki, Gautam, Steve ]

To align the green beam in Y-end
these hardware were installed:
 Pic_1Y4.jpgPic_PZTcable.jpg 
  14241   Wed Oct 10 12:38:27 2018 yukiConfigurationLSCAll hardware was installedI connected DAC - AIboard - PZTdriver -
PZT mirrors and made sure the PZT mirrors
were moving when changing the signal
  
  14243   Thu Oct 11 13:40:51 2018 yukiUpdateComputer Scripts / Programsloss measurements


Quote:


  
  14245   Fri Oct 12 12:29:34 2018 yukiUpdateComputer Scripts / Programsloss measurementsWith Gautam's help, Y-arm was locked.
Then I ran the script "armloss_dcrefl_asdcpd_scope.py"
which gets the signals from oscilloscope.
  
  14248   Fri Oct 12 20:20:29 2018 yukiUpdateComputer Scripts / Programsloss measurementsI ran the script for measuring arm-loss
and calculated rough Y-arm round trip loss
temporally. The result was 89.6ppm. (The
  
  14251   Sat Oct 13 20:11:10 2018 yukiUpdateComputer Scripts / Programsloss measurements


Quote:


  
  14254   Mon Oct 15 10:32:13 2018 yukiUpdateComputer Scripts / Programsloss measurementsI used these values for measuring armloss:


Transmissivitity of ITM
= 1.384e-2 * (1 +/- 1e-2) 
Transmissivitity
 XARM_20181015_1500.pdfYARM_20181015_1500.pdf 
  14255   Mon Oct 15 12:52:54 2018 yukiUpdateComputer Scripts / Programsadditional comments


Quote:


  
  14257   Mon Oct 15 20:11:56 2018 yukiConfigurationASCY end table upgrade planFinal Procedure Report for Green Locking
in YARM:

Purpose
  
  14258   Tue Oct 16 00:44:29 2018 yukiUpdateComputer Scripts / Programsloss measurementsThe scripts for measuring armloss are in
the directory "/opt/rtcds/caltech/c1/scripts/lossmap_scripts/armloss_scope".


armloss_derefl_asdcpd_scope.py:
  
  14260   Wed Oct 17 20:46:24 2018 yukiConfigurationASCY end table upgrade planTo do for Green Locking in YARM:

The auto-alignment servo should
be completed. This servo requires many parameters
  
  14280   Wed Nov 7 05:16:16 2018 yukiUpdateComputer Scripts / Programsarm loss measuremenentsPlease check your data file and compare
with those Johannes made last year.
I think the power in your data file may have
  
  3622   Wed Sep 29 16:56:36 2010 yutaUpdateVAC2 doors opened(Steve, Koji, Joe, Kiwamu, Yuta)
Background:
 The vent was started on Monday,
  
  3623   Wed Sep 29 18:28:32 2010 yutaUpdateComputersaldabella connects to the wireless networkBackground:
 We need laptops that connect
to the wireless network to use them in the
  
  3627   Thu Sep 30 14:09:33 2010 yutaUpdateComputersmariabella connects to the wireless networkBackground:
 We need laptops that connect
to the wireless network to use them in the
  
  3630   Thu Sep 30 18:51:50 2010 yutaUpdateComputerssetting up aldabella and mariabella(Kiwamu, Yuta)

Background:
  
  3645   Mon Oct 4 19:48:00 2010 yutaUpdateVACseveral mirrors installed to ITMX/BS chamber(Koji, Kiwamu, Yuta)
Lots of progress
 P1060901.JPGP1060904.JPG 
  3656   Tue Oct 5 21:22:46 2010 yutaUpdateVACgreen beam reached PSL tableY  IMG_3627.jpg 
  3667   Thu Oct 7 14:39:50 2010 yutaUpdatePSLmeasured PMC's laser power-output relation(Rana, Yuta)

Motivation:
 PMCreflect.png 
  3672   Thu Oct 7 16:34:06 2010 yutaUpdatePSLmeasured PMC's laser power-output relationResult2:
 Attached is the visibility vs
incident power(assuming output of the PD
 PMCvis.png 
  3674   Thu Oct 7 17:53:07 2010 yutaUpdateComputersFarfalla with Firefox, fixed(Kiwamu, Yuta)

Symptom:
  
  3675   Thu Oct 7 23:24:44 2010 yutaUpdateCDSchecking MC1 suspension dampingBackground:
 The new CDS is currently being
set up.
  
  3689   Mon Oct 11 16:09:10 2010 yutaSummarySUScurrent OSEM outputsBackground:
 The output range of the OSEM
is 0-2V.
  
  3690   Mon Oct 11 17:31:44 2010 yutaUpdateCDSActivation of DAQ channels for 8 optics(Joe, Yuta)

Background:
  
  3692   Mon Oct 11 22:04:28 2010 yutaUpdateCDSdamping for MCs are basically workingBackground:
 Even if we can't use the Dataviewer
to get the time series of each 4 DOF displacements,
 SUS-MC1.pngSUS-MC2.pngSUS-MC3.png 
ELOG V3.1.3-