40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 322 of 344  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  1145   Tue Nov 18 19:44:53 2008 AlbertoUpdateGeneralX Arm Cavity "Negative" FSRs MeasuredPrevious measurements on the X arm cavity
revealed a shift of the frequencies of the
cavity resonances from where one would expect
 2008-11-17_Linear_Fit.pdf 
  1144   Tue Nov 18 19:37:23 2008 YoichiUpdateIOOMC1 OSEM signals sign flipped and c1susvme1 restart problemAround 2PM, MC1 started to swing crazily.

The damping feedback was not working and
  
  1143   Tue Nov 18 13:28:08 2008 CarynDAQIOOnew channel for MC drum modesAlberto has added a channel for the Mode Cleaner
drum modes.
C1:IOO-MC_DRUM1
  
  1142   Mon Nov 17 20:47:19 2008 CarynSummaryGeneralDrove MC at 28kHz to excite drum modesRana, Alberto and I observed drum mode frequencies
at 23.221kHz(MC1), 28.039kHz(MC2), 28.222kHz(MC3)
while driving the mode cleaner. We observed
  
  1141   Mon Nov 17 16:59:22 2008 JenneUpdatePEMSeismometer hooked up, reading channels on DataViewerAlberto, Jenne

The Guralp Seismometer is (finally) hooked
  
  1140   Mon Nov 17 15:07:06 2008 YoichiUpdatePSLReference cavity ring downI used MATLAB's system identification tool
box to estimate the response of the reference
cavity, i.e. cavity pole.
 Fit.png 
  1139   Mon Nov 17 11:01:15 2008 AlbertoHowToElectronicsCalibrating the Frequency Standard of the MarconiI locked the [COLOR=purple][I]SRS Rubidium
Frequency Standard FS275[/I][/COLOR] to the
the 1pps from the GPS. The specs from the
 2023ASeriesOperatingManual.pdfSRS_FS275_Rubidium_Frequency_Standard.pdf 
  1138   Fri Nov 14 22:40:51 2008 YoichiUpdatePSLReference cavity ring down[quote]
To make the DEI pulser make a fast pulse
on the EO shutter EOMs, we had to make sure:
  
  1137   Fri Nov 14 20:35:47 2008 ranaUpdatePSLReference cavity ring downTo make the DEI pulser make a fast pulse on
the EO shutter EOMs, we had to make sure:
  
  1136   Fri Nov 14 19:20:42 2008 YoichiUpdatePSLReference cavity ring downThanks to Bob making the high-voltage BNC
cables for the HV pulse generator, I was
able to operate the EOM in front of
 RingDown.png 
  1135   Fri Nov 14 17:41:50 2008 JenneOmnistructureElectronicsSweet New Soldering IronThe fancy new Weller Soldering Iron is now
hooked up on the electronics bench.  
 newSolderingIron.JPG 
  1134   Fri Nov 14 11:33:19 2008 steveUpdateVACSRS-RGA installedOld Dycor rga is removed and new SRS-RGA200
installed.
It is pumped down and ready for hooking up
  
  1133   Thu Nov 13 15:50:44 2008 AlbertoConfigurationGeneralGPS 10MHz clockThe schematic of the 1Y7 rack that Alan pointed
out (see attachment) don't represent anymore
the actual rack.
 rackstuff.pdf 
  1132   Thu Nov 13 11:33:25 2008 AlbertoHowToTreasureMaking (good) Matlab figuresJust a little summary of some useful ways
to change plot settings in Matlab that I
wanted to share and remember for the future:
  
  1131   Wed Nov 12 11:36:13 2008 JenneUpdatePEMGuralp Breakout Box is ~50% hooked upThe Guralp box is about halfway hooked up
now.  The seismometer is under the BSC, and
the long cable from the seismometer to the
  
  1130   Wed Nov 12 11:14:59 2008 CarynDAQPSLMC temp sensor hooked up incorrectlyMC Temperature sensor was not hooked up correctly.
It turns out that for the 4 pin LEMO connections
on the DAQ like J13, J14, etc. the channels
  
  1129   Mon Nov 10 19:39:40 2008 steveUpdatePEMthump noise from particle counterThe particle counter is back on the IOOC location
on a piece of  FOAM 
It needs this isolation, so when the pump
 partcfm.jpg 
  1127   Mon Nov 10 16:44:14 2008 steveUpdatePEMparticle counter at MC2The particle counter was moved to MC2 table
temporarily.
It is clamped to the table at the south west
  
  1126   Mon Nov 10 11:32:49 2008 robUpdateComputersc1iscex rebooted
it was running a few cycles late
  
  1125   Mon Nov 10 11:06:09 2008 robHowToIOOmode cleaner locked
I found the mode cleaner unlocked, with (at
least) MC1 badly mis-aligned.  After checking
  
  1124   Fri Nov 7 18:38:19 2008 AlbertoDAQPSLMC temperature sensor hooked upAlberto, Rana,
we found that the computer handling the signals
from ICS-110B was C1IOVME so we restarted
  
  1123   Fri Nov 7 16:05:55 2008 steveBureaucracySAFETYinsect killer sprayed at kitchen area !
Bob and I cleaned out the sink area and sprayed
Spectracide's BUG STOP insect killer solution
  
  1122   Fri Nov 7 15:58:10 2008 ranaUpdatePEMAC is back onI'll bet Steve a dollar that it is mechanical.
The attached PDF compares all of the accelerometers
from right now.
 mc-acc.pdfmc-acc-quad.pdf 
  1121   Fri Nov 7 10:52:57 2008 steveUpdatePEMAC is back onThe 20 minutes and 6 sec thumps are not related
to the 40m ac units
This period is precisely right on so it is
 acf.jpgacc_mc1.jpgtest.jpg 
  1120   Fri Nov 7 08:08:00 2008 steveUpdatePEMAC turned off in IFO roomAll [COLOR=red]tree[/COLOR] AC units in IFO
room 104 switched off at 7:45am
I'm looking for the periodic thump signal
  
  1119   Thu Nov 6 22:07:56 2008 ranaConfigurationComputersELOG compile on SolarisFrom the ELOG web pages:

Solaris:
  
  1117   Thu Nov 6 10:06:41 2008 steveUpdateLockingarms lock degradationI have been locking the arms in the mornings
lately.
The daily drift of LSC-TRX is ~ 15% and LSC-TRY
 arms.jpg 
  1116   Thu Nov 6 09:45:27 2008 steveUpdateMOPAhead temp hick-up vs power The control room AC temp was lowered from
74F to 70F around Oct 10
This hold the head temp rock solid 18.45C
 htpr.jpg 
  1115   Wed Nov 5 12:41:36 2008 AlbertoUpdateLSCAbsolute Length and g-factor measurements conclusions[SIZE=4][B][COLOR=green]Absolute Length and
g-Factor Measurement for the 40m Arm Cavities,
Summary of Results[/COLOR][/B][/SIZE]
 2008-11-04_file_02-05.pngHOM_resonances_Xarm.pngHOM_resonances_Yarm.png 
  1114   Tue Nov 4 17:58:42 2008 AlbertoDAQPSLMC temperature sensorI added a channel for the temperature sensor
on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder.
  
  1113   Tue Nov 4 01:03:01 2008 ranaSummaryPEMperiodic thump noise in MC1_ACC[B]There seems to be a periodic thump seen
by the MC1 Accelerometers as well as the
surrounding optics.[/B]
 Untitled.pngUntitled2.png 
  1112   Tue Nov 4 00:47:53 2008 ranaUpdateASSWiener Filter performance over 5 hoursSame as before, but now with a working Ranger
seismometer.
 f2.pngf.png 
  1111   Mon Nov 3 22:35:40 2008 ranaUpdateASSWiener Filter performance over 5 hours[FONT=Comic Sans MS]To speed up the Wiener
filter work I defined a 256 Hz version of
the original 16kHz IOO-MC_L signal. The
 DAQ.pdf 
  1110   Mon Nov 3 21:38:32 2008 YoichiConfigurationGeneralnew elog[quote]I tried to recompile the elog from
the source code but the way gcc is called
must be wrong because I get this error message:
  
  1109   Mon Nov 3 19:18:47 2008 AlbertoConfigurationGeneralnew elogPhil Ehrens kindly poured our elog's content
in a CD that now is here at the 40m.
I've been trying to install the 2.7.5 version
  
  1108   Mon Nov 3 19:12:27 2008 albertoUpdateGeneralTransverse mode spacing measurement for the X armI know a lot of expectations have been building
up on these days in the scientific community
at the 40m towards a conclusive elog entry
 2008-11-02_summarizingplot.png 
  1107   Mon Nov 3 09:59:47 2008 steveUpdatePSLPSL HEPAs turned onThe psl [COLOR=chocolate]enclosure[/COLOR]
HEPAs were tuned on.
  
  1106   Sun Nov 2 21:37:22 2008 ranaUpdatePEMRanger recoveryThe ranger signal has been bad since around
11 AM on Oct 25 (last Saturday). There are
no elog
  
  1105   Sun Nov 2 20:44:58 2008 ranaUpdateASSWiener Filter performance over 5 hoursI took one 2 hour stretch of data to calculate
a MISO Wiener filter to subtract the Ranger
seismometer
 f.pngf1.png 
  1104   Sun Nov 2 20:21:58 2008 ranaConfigurationloreHP 5550dtn (Grazia) set up on allegraI set up printing to grazia from allegra.
The CUPS interface was not as straightforward
as Tobin had made it seem in the Wiki. I
  
  1103   Fri Oct 31 08:52:19 2008 steveUpdateSUSETMY damping restoredETMY watchdogs were tripped yesterday morning
also. This is a problem that existed some
months ago.(?)
 etmy2d.jpg 
  1102   Thu Oct 30 20:39:47 2008 carynConfigurationPEMtemperature sensor We attached the temperature sensor box to
the MC1/MC3 chamber with a C-clamp. We connected
the temp sensor to a 2nd box with a short
  
  1101   Thu Oct 30 11:07:25 2008 YoichiUpdateComputersWireless bridges arrivedFive wireless bridges for the GPIB-Ethernet
converters arrived.
One of them had a broken AC adapter. We have
  
  1100   Wed Oct 29 12:54:28 2008 JenneUpdatePEMCalibrated Guralp Noise compared to average ground motionHere is a calibrated noise plot of the Guralp
seismometer box.  This is the same noise
measured on Friday, measured at TP3 (just
 GuralpVert1Noise_mPERs_Ranger.png 
  1099   Wed Oct 29 12:23:04 2008 YoichiConfigurationPSLMZ alignment touched and the alarm level changedSince the MZ reflection is alarming all the
time, I tried to improve the MZ alignment
by touching the folding mirror.
  
  1098   Tue Oct 28 12:01:01 2008 josephbConfigurationComputerslinux2[quote]I have removed linux2 and its cables
from the control room and put it into 1Y3
along with op340m.
  
  1097   Tue Oct 28 11:10:18 2008 AlbertoUpdateLSCHigher Order Mode resonances in the X arms[quote]Recently we had been having some trouble
locking the full IFO in the [COLOR=green][I][FONT=Verdana]spring[/FONT][/I][/COLOR]
configuration (SRC on [COLOR=blue]+166[/COLOR]).
 HOM_resonances_Xarm.png 
  1095   Mon Oct 27 14:48:27 2008 YoichiConfigurationPSLEO shutter installed to the reference cavityI'm now preparing for cavity ring down measurements
of the reference cavity.
An EOM for polarization rotation is installed
  
  1094   Mon Oct 27 11:23:10 2008 steveUpdatePhotosnew Olympus camera with IR visionThe IR blocker was removed from our new Olympus
camera 
SP 570UZ camera.
 IRisin.JPG 
  1093   Mon Oct 27 11:16:23 2008 AlbertoConfigurationIOOStochMon CalibrationI implemented the calibration for the four
channels of the StochMon in the ioo EPICS
database. Now the output of those channels,
  
ELOG V3.1.3-