  964   Thu Sep 18 13:05:05 2008 YoichiUpdateComputersEPICS BACK[quote]
The Y-arm doesn't, because one of the digital
filters for the Y-arm lock fails to be loaded
  
  963   Thu Sep 18 12:16:01 2008 YoichiUpdateComputersEPICS BACK[quote]
Somehow the EPICS system got hosed tonight.
 We're pretty much dead in the water till
  
  962   Thu Sep 18 09:30:12 2008 steveUpdateGenerallow noise metal film resistors are inLow noise metal film resistor and capacitor
kits from www.garrettelec.com are in.
 mfr&cap.pngstorcab.png 
  961   Thu Sep 18 01:14:23 2008 robSummaryComputersEPICS BAD
Somehow the EPICS system got hosed tonight.
 We're pretty much dead in the water till
  
  960   Wed Sep 17 19:13:47 2008 AlbertoUpdateGeneralABSL: statusI installed the setup for measuring TEM01/10
on the X end table. 
I'm leaving. I shut the laser, flipped down
  
  959   Wed Sep 17 17:58:35 2008 YoichiConfigurationPSLRC sweep going onThe cavity sweep is done. The IFO is free
now.
  
  958   Wed Sep 17 17:31:24 2008 YoichiUpdatePSLFSS calibrationI calibrated the reference cavity error signal
with the following procedure.
 PZTresp.pngCalibration.pngFreqNoiseSpectrum.png 
  957   Wed Sep 17 15:22:31 2008 YoichiConfigurationPSLRC sweep going on[quote]I'm doing a cavity sweep of the RC.
Please leave the IFO untouched until the
meeting is over.[/quote]
  
  956   Wed Sep 17 13:58:36 2008 AlbertoUpdateGeneralABSL: results from the X armToday I repeated the measurement of the FSR
on the X arm cavity. The noise in the transmitted
power that made the measures fluctuate was
 Sept17_XarmFSRmeasurement_report.ps 
  954   Wed Sep 17 13:43:54 2008 YoichiConfigurationPSLRC sweep going onI'm doing a cavity sweep of the RC. Please
leave the IFO untouched until the meeting
is over.
  
  953   Wed Sep 17 12:58:12 2008 robUpdateLockingbad
Locking was pretty unsuccessful last night.
 All the subparts were locked (ARMs, PRM,
  
  952   Wed Sep 17 12:55:28 2008 robConfigurationIOOMC lengthI measured the mode cleaner length last night:

[code]
  
  951   Tue Sep 16 16:47:01 2008 peteConfigurationPSLPrototype FSS reference installedAfter verifying output, I installed the new
prototype 21.5 MHz FSS reference (Wenzel
crystal oscillator and ZHL-2 amp).  Yoichi
  
  950   Tue Sep 16 13:04:22 2008 YoichiConfigurationPEMC1:PSL-FSS_RMTEMP alarm level changedAt the request of Steve, I modified the HIGH
value of C1:PSL-FSS_RMTEMP from 21.27 to
23.0.
  
  949   Tue Sep 16 10:57:45 2008 YoichiConfigurationPEMParticle counter gainSummary:
Since we reduced the integration time of
the particle counter by a factor of 10, we
  
  948   Mon Sep 15 14:00:52 2008 josephbConfigurationComputers1Y9 Hub and C1ascThe 1Y9 switch is now using a labeled Cat6
cable in cable trays to connect to the main
switch in the offices.  In addition, the
  
  947   Sun Sep 14 19:29:07 2008 AlbertoUpdateGeneralABSL: measured X arm[quote]Today I measured the X arm FSR.
Hi moved the fast PD (Thor Labs PDA255) from
the Y end table to the X end table. I had
  
  946   Sun Sep 14 18:30:32 2008 AlbertoUpdateGeneralABSL: measured X armToday I measured the X arm FSR.
Hi moved the fast PD (Thor Labs PDA255) from
the Y end table to the X end table. I had
  
  945   Sat Sep 13 23:13:01 2008 AlbertoUpdateGeneralabs cavity length experimentThe Y arm was locked all time today but, suddenly,
this afternoon it lost lock and since then
I've been unable to restore it. I tried unsuccessfully
  
  944   Fri Sep 12 11:09:20 2008 AlbertoUpdateGeneralabs cavity length experimentI'm leaving the lab for a couple of hours.
I shut the NPRO. The interferometer is available
to anyone.
  
  943   Thu Sep 11 23:28:35 2008 albertoUpdateGeneralabs cavity length experimentThe MC lost lock for some reason not related
to either the FSS or the PMC I'm done with
my measurement for tonight. I've shut the
  
  942   Thu Sep 11 14:27:53 2008 steveBureaucracySAFETYsafety trainingPeter Kalmus received 40m specific safety
training last week.
  
  941   Thu Sep 11 11:29:14 2008 josephbConfigurationComputersFinal netgear switch in place in 1Y2I've placed the final (of 4) Netgear prosafe
24 port switch at the very top of 1Y2.  At
that location, there are no holes left to
  
  940   Wed Sep 10 19:53:53 2008 AlbertoUpdateGeneralabs length experimentUpdate of the last days work on the experiment
to measure the absolute length of the cavities.
  
  939   Wed Sep 10 13:28:25 2008 YoichiSummaryElectronicsIOO rack lost -24V (recovered)Alberto, Yoichi

This morning, the MC suddenly started to
  
  938   Wed Sep 10 08:57:03 2008 steveUpdateGeneraletmy illuminator turned offThe ETMY illuminator was left on yesterday.
I just turned it off.
  
  937   Mon Sep 8 15:38:57 2008 YoichiConfigurationPSLPOY RF amp is back to its original taskI temporarily fixed the busted ZHL-32A RF
amplifier's power connector by simply soldering
a cable to the internal circuit and pulling
  
  936   Mon Sep 8 13:47:35 2008 steveUpdatePEMthermostate setting changed[quote][quote]Some one changed the thermostat
(old control room ) setting behind 1Y6 from
73 to 79F
  
  935   Mon Sep 8 10:57:49 2008 steveUpdateIOOthe psl and mc are back to normalThe alarm handler is silent this morning.
This is almost unbelievably pleasant after
two mount of harassment.
 fss.pngpmcbrick.pngbrick.jpg 
  934   Fri Sep 5 15:09:50 2008 ranaUpdatePEMthermostate setting changed[quote]Some one changed the thermostat (old
control room ) setting behind 1Y6 from 73
to 79F
  
  933   Fri Sep 5 10:36:34 2008 steveUpdatePEMthermostate setting changedSome one changed the thermostat (old control
room ) setting behind 1Y6 from 73 to 79F
It should be in the elog.
  
  932   Fri Sep 5 09:56:14 2008 josephb, EricConfigurationComputersFunny channels, reboots, and ethernet connections1) Apparently the I00-ICS type channels had
gotten into a funny state last night, where
they were showing just noise, exactly when
  
  931   Fri Sep 5 08:34:03 2008 steveUpdatePSLMZ lockedThe MC is happy.
The MZ can be locked if you move the slider
by hand.
 mzhv.jpg 
  930   Thu Sep 4 18:02:34 2008 rana, josephbConfigurationPEMAccelerometer gains increased by 10[COLOR=chocolate][SIZE=3]We increased the
Accelerometer gains by 10 by modifying the
C1ADCU_PEM.ini file.[/SIZE][/COLOR]
 acc.png 
  929   Thu Sep 4 17:44:27 2008 YoichiUpdatePSLFSS error signal spectrumAttached is a spectrum of the FSS error signal.
There are a lot of sharp peaks above 100kHz
(the UGF of the servo is about 200kHz).
 FSS-Error-Spe.png 
  928   Thu Sep 4 17:17:03 2008 YoichiUpdateIOOMC open loop TFI measured open loop transfer functions of
the MC servo.
The UGF was about 30kHz. Since there was
 MC-OPLTF.png 
  927   Thu Sep 4 17:12:57 2008 YoichiUpdatePSLFSS open loop TFI changed the gain settings of the FSS servo.
Now the Common Gain is 5dB (the last night
it was 2dB) and the Fast Gain is 12dB (formerly
 FSS-OPLTFs.png 
  926   Thu Sep 4 17:03:25 2008 YoichiUpdatePSLRF oscillator noise comparisonI measured current spectra of the RF signal
going to the FSS EOM.
The attachment compares the spectra between
 RFSpectra.png 
  925   Thu Sep 4 16:24:56 2008 ranaConfigurationComputersAttempt to increase gain for C1:PSL-ISS_INMONPD_F via 110B[quote]We were attempting to increase the
gain on the channel C1:PSL-ISS_INMONPD_F
in preparation to do a scan of the PMC at
  
  924   Thu Sep 4 14:43:58 2008 JenneUpdatePSLPMC Open Loop GainI have measured the PMC's open loop gain.
 [SIZE=3][COLOR=green]UGF is 629.7Hz, with
a phase margin of 53 degrees.
 OpenLoopTF04Sept2008.png 
  923   Thu Sep 4 13:48:50 2008 YoichiUpdatePSLFSS modulation depthI scanned the reference cavity with the NPRO
temperature (see the attached plot).
The power ratio between the carrier and the
 RCScan.png 
  922   Thu Sep 4 11:33:25 2008 josephb, Eric, JenneConfigurationComputersAttempt to increase gain for C1:PSL-ISS_INMONPD_F via 110BWe were attempting to increase the gain on
the channel C1:PSL-ISS_INMONPD_F in preparation
to do a scan of the PMC at very low input
  
  921   Thu Sep 4 10:13:48 2008 JenneUpdateIOOWe unlocked the MC temporarily[Joe, Eric, Jenne]

While trying to diagnose some DAQ/PD problems
  
  920   Thu Sep 4 07:46:10 2008 YoichiUpdateIOOMC is now happyThe MC has been locked for more than 12 hours
continuously now !
Changes I made yesterday were:
 MC-lock.png 
  919   Thu Sep 4 07:29:52 2008 YoichiUpdatePSLc1iovme power cycled[quote]Entry 663 has a plot of this using
the PSL/FSS/SLOWscan script. It shows that
the SB's were ~8x smaller than the carrier.
  
  918   Thu Sep 4 00:38:14 2008 ranaUpdatePSLc1iovme power cycledEntry 663 has a plot of this using the PSL/FSS/SLOWscan
script. It shows that the SB's were ~8x smaller
than the carrier.
  
  917   Wed Sep 3 19:09:56 2008 YoichiDAQComputersc1iovme power cycledWhen I tried to measure the sideband power
of the FSS using the scan of the reference
cavity, I noticed that the RC trans. PD signal
  
  916   Wed Sep 3 18:45:01 2008 AlbertoConfiguration PD3 gainAlberto, Yoichi,

We found that the PD3 servo was unstable
  
  915   Wed Sep 3 18:43:19 2008 YoichiConfigurationElectronicsTwo more active probesI found two active probes, an HP41800A and
a Tektronix P6201.
Thanks John for telling me you saw them before.
 Tektronix-P6201-active-probe.pdf 
  914   Wed Sep 3 12:26:49 2008 EricSummaryCamerasWeekly SummaryFinished up simulating the end mirror error
in order to test the whether the fitting
code still provides reasonable answers despite
 SimulatedErrorComparison.png 
ELOG V3.1.3-