ID Date Author Typeup Category Subject Text Attachments
  2091   Wed Oct 14 15:48:26 2009 MottHowToGeneralPhase Noise measurementI have gotten the hang of the procedure
for measuring phase noise on the AOMs. 
Koji suggested I right up a short
  
  2115   Mon Oct 19 11:00:52 2009 steveHowToSAFETY40m safety trainingKiwamu, Alex and Zach are practicing mandatory
IR-safety scan at the 40m-PSL
40m specific safety indoctrination
 safety_10_2009.JPG 
  2164   Fri Oct 30 09:24:45 2009 steveHowToMOPAhow to squeeze more out of little


   
        
            
 44to34.jpg 
  2242   Wed Nov 11 18:43:57 2009 rana, kojiHowToPhotosIlluminated Paintbrush Technique   IMG_0215.JPGIMG_0214.JPG 
  2403   Sat Dec 12 07:36:56 2009 ranaHowToElectronicsHow to Measure the Length of a Cable: InterferometryNeed to measure the length   
  2427   Thu Dec 17 09:30:08 2009 AlbertoHowToComputersNodus sluggishThe elog has been quite slow for the last
two days. The cause is nodus, that has been
slowing down the access to it.
  
  2429   Thu Dec 17 19:03:14 2009 AlbertoHowToComputersNodus sluggish


   
        
            
  
  2540   Thu Jan 21 17:23:30 2010 josephb,alex,kojiHowToComputersRCG code fixesIn order to see the Contec DO-32L-PE
Digital output PCIe card with the new
controls, we had to add the CDO32 part to
 CDO32.png 
  2559   Tue Feb 2 13:14:09 2010 KojiHowToIOOAnatomy of New Focus Resonant EOMJoe let me use the resonant EOM for GigE
phase camera for a while.
Then, I immediately started to open
  
  2598   Fri Feb 12 14:19:28 2010 rana, steveHowToloreInternational FaxSteve showed me how to send an international
fax today:

    Load paper.
   
  
  2729   Mon Mar 29 15:26:47 2010 MottHowToComputersNew script for controlling the AG4395AI just put a script in the /cvs/cds/caltech/scripts/general/netgpibdata/
directory to control the network analyzer
called AG4395A_Run.py .   A section
  
  2734   Tue Mar 30 11:16:05 2010 josephbHowToComputersezca update information (CDS SVN)I'd like to try installing an updated multi-threaded
ezca extension later this week, allowing
for 64-bit builds of GDS ezca tools, provided
  
  2738   Wed Mar 31 03:45:49 2010 MottHowToComputersNew script for controlling the AG4395A 
I took data for the 2 NPRO PLL using
the script I wrote for the AG4395, but it
 noisy_spec.png 
  2778   Wed Apr 7 09:00:01 2010 steveHowToPEMprepare to open chamberIn order to minimize the diffusion of more
dust particles into the vented IFO vacuum
envelope
 0.5micron.jpg 
  2806   Mon Apr 19 07:38:07 2010 ranaHowToElectronicsRepair and Calibration of SR560: s/n 59650Frank noticed that this particular SR560
had an offset on the output which was unzeroable
by the usual method of tuning the trim pot
  
  2869   Mon May 3 01:16:50 2010 ranaHowToElectronicsMarconi phase noise measurement setup To try the 3-corner hat method
on the Marconis, I started to set up the
 pn.png 
  2879   Tue May 4 18:40:27 2010 ranaHowToElectronicsMarconi phase noise measurement setupTo check the UGF, I increased the gain
of the PLL by 10 and looked at how much the
error point got suppressed. The green trace
 Untitled.pngifrnoise.png 
  2906   Mon May 10 19:29:33 2010 AlbertoHowToElectronicsNew Focus 1811 PD calibrated against New Focus 1611 PDI measured the output impedance of the
New Focus 1611 PD (the 1GHz one) and it is
50 Ohm for both the DC and the AC output.
  
  2913   Tue May 11 18:58:49 2010 ranaHowToElectronicsMarconi phase noise measurement setupJust a little while ago, at 2330 UTC on
5/11, I swapped the phase noise setup to
use another Marconi - this time its the 3rd
 Untitled.png 
  2914   Wed May 12 02:21:56 2010 ranaHowToElectronicsMarconi phase noise measurement setupFinally got the 3-cornered-hat measurement
of the IFRs done. The result is attached.
 pn.png 
  2951   Wed May 19 14:36:46 2010 AidanHowToPhase CameraPhase Camera algorithm and stuff I had a think about the algorithm
we might use for the phase camera measurement.
MATLAB has an fft function that will allow
 phase_camera_DC_comp.pdfphase_camera_F1_comp.pdfphase_camera_F2_comp.pdfload_raw_data.m 
  2955   Thu May 20 10:06:56 2010 AidanHowToPhase CameraPhase Camera- raw data video    
  2982   Tue May 25 16:32:26 2010 kiwamuHowToElectronicsfront ends are back [Alex, Joe, Kiwamu]
Eventually
  
  3000   Thu May 27 10:30:32 2010 kiwamuHowToGreen LockingPSL setup for green locking I
leave notes about a plan for the green locking
  
  3017   Sun May 30 17:51:04 2010 kiwamuHowToPEMAllegra dataviewerI found the dataviewer didn't work only
on Allegra. This thing sometimes happened
as described in
  
  3070   Fri Jun 11 22:09:58 2010 valeraHowToCDSfoton It appears that foton does not like
the unstable poles, which we need to model
the transfer functions.
  
  3085   Fri Jun 18 13:42:52 2010 KojiHowToGeneralUpdate your workAll SURFs (and all others as always) are
supposed to post the update of your status
on the elog.
  
  3114   Thu Jun 24 11:16:32 2010 Sharmila, Rana and KiwamuHowToVACInspection of the BS (sorry, no sounds)    
  3118   Fri Jun 25 01:28:33 2010 DmassHowToSVNSVN woesI am trying to get an actual complete install
of the 40m svn on my machine. It keeps stopping
at the same point:
  
  3123   Sat Jun 26 05:02:04 2010 ranaHowToSVNSVN woes


   
        
            
  
  3193   Mon Jul 12 11:20:56 2010 Gopal HowToCOMSOL TipsIntrusions (Negative Extrusions)For the sake of future users, I have decided
to periodically add tips and tricks in using
COMSOL that I have figured out, most probably
 6x 
  3194   Mon Jul 12 12:16:50 2010 DmassHowToCOMSOL TipsIntrusions (Negative Extrusions) An entry on the 40m wiki page might
serve you better, and be easier to  sift
through once all is said and done
  
  3233   Thu Jul 15 23:51:47 2010 Mr. MaricHowToSUSLevitate me if you canYou guys must work harder.
 mag_lev.jpg 
  3291   Mon Jul 26 11:15:23 2010 GopalHowToCOMSOL TipsPictures from Transfer Function Tutorial on the WikiThe attached pictures give a brief overview
of my transfer function measurement procedure
in COMSOL. For more details, please see the
 7x 
  3296   Tue Jul 27 11:24:53 2010 josephbHowToComputer Scripts / Programskilldataviewer scriptI placed a script for killing all instances
of the dataviewer program on the current
computer in /cvs/cds/caltech/scripts/general/. 
  
  3336   Fri Jul 30 17:54:55 2010 steveHowToVACHow to stop and start slow pumpdown


   
        
            
  
  3338   Fri Jul 30 22:07:42 2010 KojiHowToVACHow to stop and start slow pumpdownKiwamu and Koji
The rough pumping was stopped at
230mmTorr. We are going to resume the pumping
  
  3407   Thu Aug 12 11:59:31 2010 kiwamuHowToCDSset up ntp daemom(sad story)
When I was working on a new front
end machine c1sus, I found that
  
  3491   Mon Aug 30 23:21:36 2010 ranaHowToPSL2W NPRO Mount designed with emachineshop.com softwareTo test out this website - emachineshop.com,
Jenne and I are designing some of the mounts
for the new beam height.
 LaserMount.png 
  3503   Wed Sep 1 08:36:59 2010 KojiHowToPSL2W NPRO Mount designed with emachineshop.com software1. I can not see whether the attaching
surface is flat or not.
It should have ~1mm step to avoid
  
  3536   Tue Sep 7 20:44:54 2010 YoichiHowToCOMSOL TipsCOMSOL example for calculating mechanical transfer functionsI added COMSOL example files to the 40m
svn to demonstrate how to make transfer function
measurements in COMSOL.
  
  3652   Tue Oct 5 16:30:00 2010 josephb, yutaHowToCDSScreen settings and medm screens for new systemYou can find the sitemap medm screen in
/opt/rtcds/caltech/c1/medm/master
The settings for the screens were
  
  3658   Wed Oct 6 11:03:51 2010 josephb, yutaHowToCDSHow to start diaggui for right nowI'm hoping to get a proper install this
week done, but for now, this a stop gap.
To start diagnostic test tools, go
  
  3661   Wed Oct 6 15:56:14 2010 josephbHowToCDSHow to load matrices quickly and easilyAwhile ago I wrote several scripts for
reading in medm screen matrix settings and
then writing them out.  It was meant
  
  3708   Wed Oct 13 18:01:43 2010 yutaHowToCDSeditting all the similar medm screens(Joe, Yuta)

Say, you want to edit all the similar
  
  3712   Thu Oct 14 00:54:12 2010 ranaHowToCDSBad PSL Quad, so I edited the SUS MEDM screensWe found today that there was some  Untitled.png 
  3733   Mon Oct 18 09:01:48 2010 steveHowToGeneralHow not to This BNC cable is crying for help. Please
do not do this to me.  It should be
reported  to the  abused center.Throw
 P1060926.JPG 
  3785   Tue Oct 26 12:45:20 2010 yutaHowToCDSmaking a new master file for medm screens(Joe, Yuta)

 In elog
  
  3787   Tue Oct 26 16:02:55 2010 yutaHowToCDSthings to do after making a new Simulink model(Joe,Yuta)

Things to do after making a new Simulink
  
  3959   Sat Nov 20 01:58:56 2010 yutaHowToCDSeditting RT models and MEDM screens(Suresh, Yuta)

If you come up with a good idea and
  
ELOG V3.1.3-