40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 317 of 344  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  15452   Mon Jul 6 00:37:28 2020 gautamUpdateComputersrossa: lib symlinkThis is strange - I was definitely able
to launch medm when I was working on this
machine remotely on Friday. But now, there
  
  15453   Mon Jul 6 08:48:15 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake lab today
from 8:30am to 4pm
  
  15454   Mon Jul 6 12:43:02 2020 ranaUpdateComputersrossa: lib symlinkyes, I rebooted yesterday to fix the 'steaking
white lines' problem in the video/display

maybe we're supposed to edit
  
  15455   Mon Jul 6 12:51:41 2020 gautamUpdateComputersrossa: resolvconf installedIndeed, this is now fixed by following
instructions from here.
I rebooted rossa at ~1250 PDT and confirmed
  
  15457   Mon Jul 6 17:41:19 2020 gautamUpdateLSCAn LSC puzzlerLast Tuesday evening, while attempting
the PRFPMI locking, I noticed a strange feature
in the LSC signals, which is shown in 
 LSCsignals.jpg 
  15458   Tue Jul 7 14:06:10 2020 gautamUpdateASCSome more thoughts about ASCSummary:

I want to be able to run the dither
alignment servo with the PRFPMI locked -
 ITM_OL_DCcoupling.png 
  15459   Wed Jul 8 08:51:35 2020 JordanUpdateGeneralPresence at 40mI will be in the clean and bake lab today
from 9am to 3pm.
  
  15460   Wed Jul 8 22:50:33 2020 gautamUpdateComputersrossa: more symlinksI wanted to try using rossa as my locking
workstation today. However, a few problems
became quickly evident. Basically, any of
  
  15461   Thu Jul 9 09:22:44 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake lab today
from 9am to 3pm
  
  15463   Thu Jul 9 16:16:20 2020 gautamUpdateComputersrossa: graphics driver issues?I noticed these streaky lines again today
(but they were not a problem last night).
It is annoying if we have to reboot this
  
  15464   Thu Jul 9 17:12:52 2020 gautamUpdateBHDIn-air BHDSummary:

We can probably learn something
about the interferometer / top level BHD
 OMCchamber.pdfAP_Table_20180328.pdf 
  15466   Fri Jul 10 01:25:28 2020 gautamUpdateLSCLocking notesMore tomorrow, but I tried the following
tonight:


Dither alignment for PRC
  
  15467   Fri Jul 10 10:37:30 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake lab today
from 9am to 4pm
  
  15468   Fri Jul 10 15:26:28 2020 gautamUpdateLSCMC2 coils need DC balancing?I was looking at some signals from last
night, see Attachment
 MC2_balancing.pngASDC.png 
  15469   Sat Jul 11 00:10:22 2020 gautamUpdateComputersrossa: more developmental workAfter some consultation with Erik von Reis
at LHO, this workstation is progressing towards
being usable
  
  15470   Sat Jul 11 18:24:30 2020 KojiUpdateLSCMC2 coils need DC balancing?> Can't
we offload this DC signal to the laser crystal
  
  15471   Sun Jul 12 02:42:01 2020 gautamUpdateLSCLocking (on rossa)Main goals tonight were:


Check if I can lock the
interferometer by working on rossa - indeed,
 ASCsteps.png 
  15472   Sun Jul 12 22:40:35 2020 gautamUpdateElectronicsWFS characterization - old SURF reportAfter some hunting, I found this
old SURF report with the WFS head measurements.
The y-axes don't make much sense to me,
  
  15473   Mon Jul 13 11:33:18 2020 ranaUpdateComputersrossa: more developmental workI too, would prefer py3 for everything,
but aren't all the cdsutils / gaurdian
things still python2?
  
  15474   Mon Jul 13 11:36:08 2020 ranaUpdateLSCMC2 coils need DC balancing?
if IMC REFL is not increasing,
I don't think its a mis-alignment. Usually,
REFL is a more sensitive indicator of alignment
  
  15475   Mon Jul 13 12:37:05 2020 gautamUpdateComputersrossa: more developmental workIn fact, all these utilities are now available
in python3. There may be some bugs (e.g.
this),
  
  15476   Tue Jul 14 00:06:09 2020 gautamUpdateLSCLocking with POX for CARMI tried using the POX_I error signal for
the DC CARM_B path today a couple of times.
Got to a point where the AO path could be
  
  15477   Tue Jul 14 01:55:03 2020 KojiUpdateLSCLocking with POX for CARMThe usual technique is that keeping the
IFO locked with the old set of the signals
and the relative gain/TF between the conventional
  
  15478   Tue Jul 14 09:04:53 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake Lab today
from 9am to 4pm.
  
  15479   Tue Jul 14 15:29:25 2020 gautamUpdateBHDIn-air BHD - DCPD amplifier noiseFor the first pass, it's probably easiest
to use the existing DCPD
amplifier. Looking at the gain and noise
 DCPDamp.pdf 
  15480   Tue Jul 14 16:52:47 2020 gautamUpdateElectronicsCoil drivers for the test massesSummary:

Koji and I had a discussion last
Friday about the suspension electronics.
 coilDriverSchem.pdf 
  15481   Tue Jul 14 17:28:29 2020 gautamUpdateLSCLocking with POX for CARMFrom Attachment
#1, looks like the
 PRFPMI_2020712sensMat.pdfLSCerrSigs.pdf 
  15483   Wed Jul 15 19:11:40 2020 gautamUpdateBHDIn-air BHD - alignment into OMCI forgot about the pointing - probably
we will need another actuator to control
the pointing of the AS beam onto the DCPDs.
  
  Draft   Wed Jul 15 19:17:09 2020 gautamUpdateBHDIn-air BHD - alignment into OMCYou can activate all 3axis

 
  
  15485   Wed Jul 15 19:23:44 2020 gautamUpdateGeneralEmergency light on in control roomThe emergency lamps above the exit sign
on the NW entrance to the control room are
on. I tried opening and closing the door,
  
  15486   Wed Jul 15 19:51:51 2020 KojiUpdateGeneralEmergency light on in control roomIt happened before too. Doesn't it
say it has occasional self-testing or something?
  
  15487   Wed Jul 15 20:58:40 2020 gautamUpdateGeneralEmergency light on in control roomTrue - it is now not on anymore.




  
  15488   Wed Jul 15 21:08:43 2020 gautamUpdateElectronicsETM coil outputs DQedTo facilitate this investigation, I've
DQed the 4 face coil outputs for the two
ETMs. EX is currently running with 5 times
 CDS.pngcoilOutDQed.png 
  15489   Thu Jul 16 01:12:22 2020 gautamUpdateBHDIn-air BHD - preparing the LO pathAttachment
#1 - The 80mW pickoff
 IMG_8626.JPGIMG_8627.JPGIMG_8628.JPGIMG_8629.JPG 
  15490   Thu Jul 16 14:41:22 2020 gautamUpdateGeneralFire extinguisher inspectionThe (masked) tech accessed all areas in
the lab (office area, control room, VEA)
between ~230pm-3pm. The laser safety goggles
  
  15491   Fri Jul 17 00:18:13 2020 gautamUpdateGeneralLocking updat
I found that an EPICS channel wasn't
reset to the correct value by burtrestore
after the FE bootfest yesterday.

This
  
  15492   Fri Jul 17 09:03:58 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake lab today
from 9am to 4pm.
  
  15493   Sun Jul 19 15:40:15 2020 gautamUpdateBHDIn-air BHD - CDS and wiring summaryAttachment
#1 shows the proposed
 wiringDiagram.pdf 
  15494   Mon Jul 20 17:23:46 2020 gautamUpdateElectronicsCoil drivers for the test massesSummary:

Looking at the signals to the test
mass coils, it seems borderline
 ALSlock_timeDomain.pdfALSlock.pdfRFlock.pdf 
  15495   Mon Jul 20 17:55:15 2020 gautamUpdateBHDIn-air BHD - preparing the LO pathThe LO pickoff has been coupled into a
fiber with ~90% MM (8 mW / 9 mW input). While
I wait for the DCPD electronics to be found
  
  15497   Tue Jul 21 00:30:24 2020 gautamUpdateBHDIn-air BHD - LO RINAttachment
#1 shows the RIN of
 LO_RIN.pdf 
  15498   Tue Jul 21 16:41:46 2020 gautamUpdateBHDPMC assembly space I decided to use the old EY auxiliary optics
table, which is now stored along the east
arm about 10 m from the end, as a workspace
 IMG_8635.JPG 
  15500   Fri Jul 24 15:40:59 2020 JordanUpdateVACInstallation of two new UPS unitsI installed the Tripp
Lite SMX1000RT2U and Tripp
Lite Smart1000LCD at the
 UPS.jpg 
  15502   Tue Jul 28 12:22:40 2020 JonUpdateVACVac interlock test today 1:30 pmThis afternoon Jordan is going to carry
out a test of the V4 and V5 hardware
interlocks. To inform the interlock improvement
  
  15503   Tue Jul 28 13:55:11 2020 HangUpdateBHDExploring bilinear SRCL->DARM couplingWe explore bilinear SRCL to DARM noise
coupling mechanisms, and show two cases that
by doing BHD readout the noise performance
 SRCL_bilin_DHARD.pdfARM_RIN.pdfSRCL_bilin_SRCL.pdf 
  15504   Tue Jul 28 14:11:14 2020 JonUpdateVACVac interlock test today 1:30 pmThis test has been completed. The IFO configuration
has been reverted to nominal.

For future reference: yes,
  
  15505   Wed Jul 29 11:57:59 2020 ranaUpdateBHDIn-air BHD - CDS and wiring summary3. I agree - this whitening will be handy
to have for diagnostics.

4. I think in principle, we can
  
  15506   Thu Jul 30 16:16:43 2020 gautamUpdateSUSSuspension recoveryThis
earthquake and friends had tripped all
watchdogs. I used the scripted watchdog re-enabler,
  
  15507   Thu Aug 6 00:34:38 2020 YehonathanUpdateBHDMonte Carlo SimulationsI've pushed an MCMC simulation to the
A+ BHD repo (filename MCMC_TFs.ipynb). The
idea is to show how random offsets around
 8x 
  15508   Thu Aug 6 22:57:20 2020 gautamUpdatesafetyNew live HV SuppliesBe aware that there is now a KEPCO HV supply
that is energized, sitting on the floor immediately
adjacent to the OMC rack, east of the AP
  
ELOG V3.1.3-