  12207   Tue Jun 21 11:26:42 2016 varunFrogsCDSmedm command not working"medm: command not
found" error when run through
  
  12208   Tue Jun 21 11:49:29 2016 ericqFrogsCDSmedm command not workingThe workstations' .bashrc
is a symbolic link to /users/controls/.bashrc

In it, someone commented out the
  
  12214   Sun Jun 26 15:27:28 2016 ranaFrogsIOOPMC /MC lopcedFound PMC unlocked for many hours so I
relocked it. IMC relocked by itself, but
the input switch seems to be flickering to
  
  12646   Tue Nov 29 17:46:18 2016 rana, gautamFrogsComputer Scripts / Programsgateway PWD changeWe found that someone had violated all
rules of computer security decency
and was storing our nodus password as a plain
  
  12694   Fri Jan 6 17:00:26 2017 ranaFrogsTreasureVideo of Lab TourIn this video: https://youtu.be/iphcyNWFD10,
the comments focus on the orange crocs, my
wrinkled shirt, and the first aid kit.
  
  13037   Sun Jun 4 14:19:33 2017 ranaFrogsComputersNetwork slowdown: Martians are behind a waterwallA
few weeks ago we did some internet speed
tests and found a dramatic difference between
 Screen_Shot_2017-06-04_at_1.47.47_PM.pngScreen_Shot_2017-06-04_at_1.44.42_PM.png 
  13316   Mon Sep 18 15:00:15 2017 rana, gautamFrogsComputer Scripts / Programsgateway PWD changeWe implemented   
  13470   Fri Dec 8 23:31:31 2017 johannesFrogsASSc1ass slow channel offloading scripts with small While staring at epics records all day
I noticed something about the PIT/YAW offset
sliders and ASS offset offloading to slow
  
  13476   Thu Dec 14 19:33:20 2017 gautamFrogsASSc1ass slow channel offloading scripts with small I
don't think this is really a problem
  
  13910   Fri Jun 1 21:47:23 2018 KojiFrogsGeneralTouch screen manipulation of the IFO[Koji Gautam]

We talked about touch interface
of medm. We realized that android (and iOS)
 Screenshot_20180601-214459.png 
  14186   Tue Aug 28 15:29:19 2018 SteveFrogsPEMRat is cutThe rat is cut by mechanical trap and it
was removed from ITMX south west location.

A nagy kover patkanyt a fogo elkapta
 rat#2.png.png 
  14336   Fri Dec 7 19:42:47 2018 ranaFrogselogcan't upgrade DokuWiki because of PHP / SL7All of our wikis (except the 40m one which
unfortunately got turned into ligo.org mess)
use DokuWiki. This now has an auto-upgrade
  
  14545   Mon Apr 15 22:55:34 2019 gautamFrogsThermal CompensationLab thermostat adjustedIt is feeling cold in the office area.
According to the digital wall clock near
the coffee machine, it is 19C. Rana bumped
  
  15081   Fri Dec 6 15:22:01 2019 gautamFrogsLSCDAFI system revived[Jordan, gautam]

We did the following:
  
  15162   Tue Jan 28 08:26:53 2020 ranaFrogsPEMshakinghttps://breakthrough.caltech.edu/magazine/2019-aug/#article-Listening-with-Light

  
  15882   Mon Mar 8 20:11:51 2021 ranaFrogsComputer Scripts / Programsactivate_matlab out of control on Megatronthere were a zillion processes trying to
activate (this is the initial activation
after the initial installation) matlab 2015b
  
  16325   Tue Sep 14 15:57:05 2021 jamieFrogsCDSfb1 /var full after reboot, caused all sorts of problems/var on fb1 filled up today, which caused
all sorts of CDS issues.  I found out
about the problem by reading the logs of
  
  16327   Tue Sep 14 16:44:54 2021 jamieFrogsCDSfb1 /var full after reboot, caused all sorts of problemsJonathan Hanks pointed me to this fix to
the gpstime kernel module that was unfortunately
put in after the 3.4 release that we're
  
  16339   Thu Sep 16 14:08:14 2021 Ian MacMillanFrogs TourI gave some of the data analysts a look
around because they asked and nothing was
currently going on in the 40m. Nothing was
  
  17261   Fri Nov 11 20:01:56 2022 ranaFrogsComputer Scripts / ProgramsFSS SLOW servo not runningI was trying to debug why the NPRO PZT
is all over the place, and it turns out that
the new FSS SLOW script is not actually running.
  
  17262   Fri Nov 11 20:59:13 2022 ChrisFrogsComputer Scripts / ProgramsFSS SLOW servo not runningThe problem with trends was due to the
epics data collection process (standalone_edc)
that runs on c1sus. When all the FEs were
  
  17263   Sat Nov 12 21:59:24 2022 AnchalFrogsComputer Scripts / ProgramsFSS SLOW servo not runningI stopped the Docker PID script and started
the old python script on megatron. Instructions
on how to do this are here.
  
  17281   Thu Nov 17 16:48:07 2022 AnchalFrogsComputer Scripts / ProgramsFSS SLOW servo running NowI've moved the FSS Slow PID script
running to megatron through systemd daemons.
The script is working as expected right now.
  
  94   Mon Nov 12 14:09:19 2007 robDAQGeneraltpman dead on fb40mThe testpoint manager was dead on fb40m. 
I know I re-started it sometime after the
power outage, so something must have killed
  
  152   Fri Nov 30 21:27:24 2007 ranaDAQPEMweather / stacis / c1pem1I was trying to add some Seis BLRMS channels
to the c1pem1 processor so that we could
have DMT trends.
  
  157   Mon Dec 3 00:10:42 2007 ranaDAQComputer Scripts / ProgramslinemonI've started up one of our first Matlab based
DMT processes as a test.
  
  160   Mon Dec 3 19:06:49 2007 ranaDAQComputer Scripts / ProgramslinemonI turned up my nose at Matlab's special tools.
I modified the linetracker to use the
relationship [U][B]phase = 2*pi*f*t[/B][/U]
 spd64d1.jpg 
  170   Wed Dec 5 19:25:07 2007 ranaDAQCDSDMFI made a database file on C1AUX called dmf.db.
It has 9 DMF EPICS channels which are also
trended
  
  204   Wed Dec 19 20:28:27 2007 AndreyDAQPEMNames for all 6 accelerometers have been changed
I eventually [COLOR=red]changed the names
for all 6 accelerometers[/COLOR] (see my
  
  312   Tue Feb 12 16:34:07 2008 robDAQDMFseisBLRMS 1.1
The compiled version of seisBLRMS had been
running ~2 weeks without crashing as of last
  
  316   Thu Feb 14 15:04:53 2008 robDAQDMFDMF delay
Sometime ago I edited seisBLRMS to keep of
track of how long it was taking to write
 DMFdelay.png 
  317   Thu Feb 14 15:05:18 2008 robDAQDMFseisBLRMS 1.1

> Also, for reasons of aesthetics, I changed
  
  358   Tue Mar 4 23:22:32 2008 robDAQComputersc1susvme1&2 rebooted
I found that some channels from c1susvme1
and c1susvme2 were not being recording by
  
  440   Wed Apr 23 22:39:54 2008 AndreyDAQComputer Scripts / ProgramsProblem with "get_data" and slow PEM channels
It turns out that I cannot read minute trends
for the slow weather channels for more than
  
  456   Sun Apr 27 18:11:58 2008 robDAQComputersbr40m?
The testpoint manager (which runs on fb40m)
crashed this afternoon.  Upon re-starting
  
  457   Sun Apr 27 22:57:15 2008 ajwDAQComputersbr40m?[quote]
The testpoint manager (which runs on fb40m)
crashed this afternoon.  Upon re-starting
  
  459   Tue Apr 29 21:09:12 2008 ranaDAQCDSFE FiltersThese are new FE filters for downsampling
and upsampling. We will be going from native
hardware sampling rates of 64k down to 32k,
 fefilters.jpgfefilters.txt 
  583   Fri Jun 27 15:20:52 2008 robDAQLSC.ini file change
I removed C1:LSC-XARM_CTRL from the frames
and added C1:LSC-CARM_ERR
  
  640   Mon Jul 7 13:58:37 2008 Eric, josephbDAQPEMUsing unused PEM channels to test camera codeJoe and I have taken control of the EPICS
channels C1:PEM-Stacis_EEEX_geo and C1:PEM-Stacis_EEEY_geo
since we heard that they are no longer in
  
  660   Fri Jul 11 20:16:01 2008 EricDAQCamerasTaking data from the GC 750 CameraMafalda has been set up with a background
process to constantly take data from the
GC 750 camera (at the end of the x-arm) for
  
  671   Tue Jul 15 10:09:42 2008 EricDAQCamerasDid anyone kill the picture taking process on Mafalda?Did anyone kill the process on Mafalda that
was taking pictures of the end mirror of
the x-arm last Friday?  I need to know whether
  
  673   Tue Jul 15 11:47:56 2008 JenneDAQPEMAccelerometer channels in ASS Adapt MEDM screenJenne, Sharon

We have traced which accelerometers correspond
  
  684   Wed Jul 16 17:36:51 2008 JohnDAQPSLFSS input offsetI changed the nominal FSS input offset to
0 from 0.3. Tolerance remains unchanged at
+/-0.05.
  
  700   Fri Jul 18 19:43:55 2008 YoichiDAQComputersPSL fast channels cannot be read by dataviewerAt this moment only the PSL fast channels
have trouble.
Rob restarted fb40m, c1IOVME, but no effect.
  
  826   Mon Aug 11 19:09:28 2008 JenneDAQPEMSeismometer DAQ is being funnyWhile looking at the Ranger seismometer's
output to figure out what our max typical
ground motion is, Rana and I saw that the
 SeisDAQ.pngSeisData.png 
  917   Wed Sep 3 19:09:56 2008 YoichiDAQComputersc1iovme power cycledWhen I tried to measure the sideband power
of the FSS using the scan of the reference
cavity, I noticed that the RC trans. PD signal
  
  1028   Mon Oct 6 12:45:41 2008 AlbertoDAQLSCC1LSC in comaAlberto, Joe,

The C1LSC medm screen is frozen and the C1LSC
  
  1029   Mon Oct 6 16:41:33 2008 AlbertoDAQLSCC1LSC in coma[quote]Alberto, Joe,

The C1LSC medm screen is frozen and the C1LSC
  
  1066   Wed Oct 22 09:42:41 2008 AlbertoDAQComputersc1iool0 rebooted and MC autolocker restartedThis morning I found the MC unlocked. The
MC-Down script didn't work because of network
problems in communicating with scipe7, a.k.a.
  
  1114   Tue Nov 4 17:58:42 2008 AlbertoDAQPSLMC temperature sensorI added a channel for the temperature sensor
on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder.
  