  11585   Wed Sep 9 11:33:58 2015 ranaUpdateSummary PagesSummary Page updates
Made most plots in IOO tab only
plot when MC_TRANS > 10000 using Eve's
MC_LOCK state definition.
added
  
  12703   Wed Jan 11 19:20:23 2017 Max IsiUpdateSummary PagesDecember outageThe summary pages were not successfully
generated for a long period of time at the
end of 2016 due to syntax errors in the PEM
  
  12709   Thu Jan 12 23:22:34 2017 ranaUpdateSummary PagesDecember outagePages still not working: PEM and MEDM blank.


Committed existing MEDM
grabbing scripts to SVN. Ran the cron job
  
  12713   Fri Jan 13 14:33:00 2017 MAX (not Rana)UpdateSummary PagesDecember outagePEM config file was also lacking a section
named "summary", which is necessary
for all parent tabs; this has now been solved.
  
  12749   Tue Jan 24 07:36:56 2017 Max IsiUpdateSummary PagesCluster maintenanceSystem-wide CIT LDAS cluster maintenance may
cause disruptions to summary pages today.
  
  12752   Wed Jan 25 09:00:39 2017 Max IsiUpdateSummary PagesCluster maintenanceLDAS has not recovered from maintenance causing
the pages to remain unavailable until further
notice.
  
  12787   Thu Feb 2 11:25:45 2017 Max IsiUpdateSummary PagesCluster maintenanceFYI this issue has still not been solved,
but the pages are working because I got the
software running on an
  
  12831   Wed Feb 15 22:16:05 2017 Max IsiUpdateSummary PagesNew condor_q formatThere has been a change in the default
format for the output of the condor_q command
at CIT clusters. This could be problematic
  
  12870   Mon Mar 6 14:47:49 2017 gautamUpdateSummary PagesCode status check script modifiedFor a few days now, the "code status"
page
has been telling us that the summary pages
  
  13049   Wed Jun 7 14:27:23 2017 SteveUpdateSummary Pagessummery pages not workingLast good page May 18, 2017

Not found, error message May 19
- June 4,2017
  
  224   Thu Jan 3 12:38:49 2008 robBureaucracyTMISore throat[quote]
I did not feel anything wrong yesterday,
but [COLOR=red]unfortunately I have [/COLOR]
  
  229   Wed Jan 9 20:29:47 2008 DmassAoGTMICoffee CarafeIf you have been using the coffee machine
in the 40m, you may have noticed small brown
flecks in your coffee mug. The carafe in
 DSC_0363.JPGDSC_0365.JPGDSC_0368.JPG 
  279   Mon Jan 28 12:42:48 2008 DmassBureaucracyTMICoffeeThere is tea in the coffee carafe @ the 40m.
It is sitting as though it were fresh coffee.
There is also nothing on the post it.
  
  341   Tue Feb 26 20:24:04 2008 AndreySummaryTMISorrowAs for that plot of three-dimensional surface,
I indeed was wrong with the axis "Q_ETMX-Q_ITMX"
(I put there wrong string "Q_ITMX-Q_ETMX").
  
  2887   Thu May 6 17:47:01 2010 Alberto, kiwamu, Jc The 3rd (aka The Drigg)OmnistructureTMIMinutes from the Lab Organization Commitee meetingToday we met and we finally come up with
a lot of cool, clever, brilliant, outstanding
ideas to organize the lab.
  
  2888   Thu May 6 17:54:44 2010 Zach Korth -- Committee Oversight (Fun Division)OmnistructureTMIMinutes from the Lab Organization Commitee meetingWhere are we going to put the tiki bar?
The ice cream machine? I am disappointed
in the details that appear to have been glossed
  
  14041   Fri Jul 6 12:12:09 2018 AnnalisaConfigurationThermal CompensationThermal compensation setupI tried to put together a rudimentary heater
setup. 

As a heating element, I used the
 IMG_1887.jpgIMG_1884.jpgIMG_1883.jpgIR20180706_0358_labels.png 
  14043   Sat Jul 7 19:50:38 2018 AnnalisaConfigurationThermal CompensationStudy about the Thermal projection setup and its effect on the cavityI made some simulation to study the change
that the heater setup can induce on the Radius
of Curvature of the ETM.
 6x 
  14050   Tue Jul 10 23:44:23 2018 AnnalisaConfigurationThermal CompensationHeater setup assembly[Annalisa, Koji]

Today both the heater and the reflector
were delivered, and we set down the setup
 8x 
  14071   Fri Jul 13 23:39:46 2018 AnnalisaConfigurationThermal CompensationThermal compensation setup - power supply[Annalisa, Rana]

In order to power the heater setup
to be installed in the ETMY chamber,
 IMG_2012.jpgIMG_2013.jpg20180713_213818.jpg 
  14078   Tue Jul 17 17:37:46 2018 Annalisa, TerraConfigurationThermal CompensationHeaters installationSummary

We
installed two heaters setup on the ETMY bench
in order to try inducing some radius of curvature
 6x 
  14086   Thu Jul 19 04:44:09 2018 Annalisa, TerraSummaryThermal Compensationfrequency shift observed with heating!Annalisa, Gautum, Koji, Terra

Summary: with
the reflector setup, we measured a frequency
 scanning_fine_2018-07-19-07-32-08_parsed.pdfscanning_fine_2018-07-19-06-57-47_parsed.pdfYscan_scanning_parsed_2am.txt.pdf 
  14094   Sat Jul 21 01:06:49 2018 gautamSummaryThermal CompensationY arm lockingI implemented this today. For now, the
LSC output matrix is set to actuate on MC2
for Y arm locking. As expected, the transmission
  
  14096   Sat Jul 21 14:03:19 2018 KojiSummaryThermal CompensationY arm lockingAh. With MC2 feedback, we have about 3
times smaller "optical gain" for
the ASS A2L. We have same dither, same actuator,
  
  14103   Wed Jul 25 14:45:59 2018 SandrineSummaryThermal CompensationETM Y Table AUX read outAttached is a photo of the set up of the
ETM Y table showing the AUX read out set
up. 
 EY_table_.JPG 
  14105   Thu Jul 26 01:52:01 2018 terraUpdateThermal Compensationheater work updateJust a quick update: over the past few
days we've taken (at least) 5 scans around
each peak [carrier - HOM3] at 9.4V/0.8A,
 OpLev_thermal_drift.pdfhotColdAll.pdf 
  14109   Fri Jul 27 17:16:14 2018 SandrineUpdateThermal CompensationCopied working scripts for mode spectroscopy into new directory (modeSpec)The scripts: AGfast.py, make HDF5.py, plotSpec_marconi.py,
and SandrineFitv3.py were copied into the
new directory modeSpec.
  
  14110   Sat Jul 28 00:45:11 2018 terra, sandrineSummaryThermal CompensationHeater measurements overview[Sandrine, Koji, Terra]

Summary: We
completed multiple scans at different heating
 7x 
  14405   Fri Jan 18 15:34:37 2019 gautamUpdateThermal CompensationElliptical reflector part numberNobody documented this, but here is the
part number with mechanical drawings of the
elliptical reflector installed at EY: 
  
  14545   Mon Apr 15 22:55:34 2019 gautamFrogsThermal CompensationLab thermostat adjustedIt is feeling cold in the office area.
According to the digital wall clock near
the coffee machine, it is 19C. Rana bumped
  
  7924   Tue Jan 22 09:18:50 2013 SteveUpdateTip - Tilttip tilt bases orderedThe corrected drawing base for tip tilt
with coils are going to the shop. The will
be back by the end of the week.
 TTbc.PDF 
  7925   Tue Jan 22 11:09:58 2013 SteveUpdateTip - TiltSS mirror holder orderedKoji's design of the SS  2" mirror
holder with flexure spring optic retainer 
like Polaris-K1 has been ordered. We are
 D1201574_v1_Tip-Tilt_Mirror_Holder.SLDDRW 
  14047   Mon Jul 9 17:29:28 2018 Udit KhandelwalSummaryTip-TIltTipTilt mirror holder final changesFinal Summary of changes to mirror holder
in Tip-Tilt holder.

Determining minimum range
 d_COM.png1-1.png1-2.png2-1.png 
  14439   Thu Feb 7 17:27:53 2019 KojiSummaryTip-TIltFive FiveNine Optics Optics delivered5 PR3/SR3 optics from FiveNine Optics were
delivered. The data sheets were scanned and
uploaded to the following wiki page. https://wiki-40m.ligo.caltech.edu/Aux_Optics
  
  14442   Fri Feb 8 00:20:56 2019 gautamSummaryTip-TIltFive FiveNine Optics Optics deliveredThey have been stored on the 3rd shelf
from top in the clean optics cabinet at the
south end. EX
  
  14444   Fri Feb 8 20:35:57 2019 gautamSummaryTip-TIltCoating spec[Attachment
#1]: Computed spectral
 specRefl.pdfAoIscan.pdf 
  14474   Tue Mar 5 15:56:27 2019 gautamSummaryTip-TIltDiscussion points about TT re-designChub, Koji and I have been talking about
Udit's re-design. Here are a few points
that were raised. Chub/Koji can add to/correct
  
  17099   Tue Aug 23 14:59:15 2022 JCUpdateToolsNew Toolbox at Y-EndA new tool box has been placed at the Y-end!
Each drawer has its label so PLEASE
put the tools back in their correct location.
 9AFD3E49-0C5B-4626-889A-0A5C62590AD7.jpeg99EC2EB1-EEA0-4AD8-B6D7-A494431E91E5.jpeg 
  230   Wed Jan 9 20:36:42 2008 GoUpdateTreasureMoney in labGo's Desk.  DSC_0370.JPG 
  259   Thu Jan 24 12:50:50 2008 JohnSummaryTreasureSugar NapoleonsSome pictures from the group meeting yesterday.  Sweeties.pdf 
  402   Tue Mar 25 15:56:09 2008 JohnUpdateTreasureAssorted picturesSome pictures scavenged from the D40.  D40.pdf 
  493   Fri May 23 08:24:24 2008 ranaAoGTreasureYoichi Aso has arrived !   Colossus_back_(800_x_600)-thumb.jpg 
  737   Thu Jul 24 21:53:00 2008 ranaSummaryTreasureHigh School Tour group and the PMCThere was a tour today of 40 high school kids.
[COLOR=red]I warned them that the lasers
could burn out their
  
  976   Mon Sep 22 15:02:45 2008 ranaFrogsTreasureMantis found outside the 40m door at night   mantis.JPG 
  1132   Thu Nov 13 11:33:25 2008 AlbertoHowToTreasureMaking (good) Matlab figuresJust a little summary of some useful ways
to change plot settings in Matlab that I
wanted to share and remember for the future:
  
  1618   Thu May 21 18:21:57 2009 ranaSummaryTreasureYoichi's words    
  2012   Mon Sep 28 11:52:23 2009 JenneUpdateTreasureOAF screen added to the screenshots webpageI used Kakeru's instructions in elog 1221
to add the C1OAF screen (still called C1ASS_TOP)
  
  2410   Mon Dec 14 12:13:52 2009 JenneUpdateTreasureWe are *ROCKSTARS* ! IFO is back up[Jenne, Kiwamu, Koji]
We
 Jenne14Dec09_IFOlocked.png 
  2411   Mon Dec 14 13:08:33 2009 KojiUpdateTreasureLOCKSTARSGood job guys. What I did was
saying "I don't know", "Maybe",
  
  2412   Mon Dec 14 13:17:33 2009 robUpdateTreasureWe are *ROCKSTARS* ! IFO is back up 
 
 two-thumbs-up.jpeg 
ELOG V3.1.3-