40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 316 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  688   Thu Jul 17 08:30:15 2008 steveUpdatePSLPMC relocked manuallyThe PMC pzt HV and the servo gain adj. are
railing at max this morning
 pmc4d.jpg 
  705   Mon Jul 21 10:00:42 2008 steveUpdatePEMifo room tempFive years of temp trend with 5 C fluctuation.
The campus chilled water supply was upgraded
~ 1 year ago.
 temp5y.jpg 
  708   Mon Jul 21 15:52:22 2008 steveBureaucracySAFETYfire alarms testThe fire alarm test and evacuation drill was
successfully completed at 13:45 Wednesday,
July 16, 2008
  
  712   Tue Jul 22 09:24:17 2008 steveUpdatePSLlaser powerLaser power reality of 120 days  power120d.jpg 
  716   Tue Jul 22 16:50:09 2008 steveMetaphysicsEnvironmentprofessorial clean up of work benchAtm1: is showing the spiritual satisfaction
after work bench clean up by the professor
himself.
 ranaclup.pngcleanup2.png 
  790   Mon Aug 4 12:12:20 2008 steveConfigurationVACthe ifo is at atmThe 40m vac envelope was vented this morning.
P1 is at 760 Torr
 vent3h.jpgUntitled.png 
  797   Tue Aug 5 10:23:00 2008 steveUpdateSUSearthquake and venting effectsatm 1, EQ
atm 2, vent 7 days later: venting kicks optic
into place to be free,
 eq4h.jpgvent4hr.jpg 
  831   Wed Aug 13 17:00:59 2008 steveConfigurationSUSBS sat amp removedThe PRM sat amp is broken. Ben is working
on it.
The BS sat amp was removed from the BS sus
  
  833   Thu Aug 14 10:26:45 2008 steveHowToSUSsus cable pin cheater for out of vac dampingThe 40m D25 vacuum feed troughs give you a
mirror image pin count.
 suscabmin.png 
  834   Thu Aug 14 11:39:06 2008 steveUpdatePEMparticle counter is out of orderThe 40m ifo paricle counter sensor failed
last night.
  
  840   Fri Aug 15 14:12:31 2008 steveBureaucracySAFETYsafety glasses required The MOPA shutter is opened,
the PSL enclosure is switched to bypass mode,
manual block removed from PMC,
  
  843   Fri Aug 15 19:32:49 2008 steveConfigurationVACpumpdown completeI have just reached vacuum normal. The maglev
peaked at 49.8C body temp with aux fan on
at 3.2 Torr
 pdprm.jpg 
  845   Mon Aug 18 09:19:55 2008 steveSummaryVAC11 days at atmIt took 11 days to fix earth quake triggered
sus problems of ITMX, SRM and PRM
Only ITMX north and BSC north vac doors were
 ventprm.jpg 
  865   Thu Aug 21 10:24:20 2008 steveConfigurationSAFETYlaser safe mode conditionThe MOPA and PSL shutters are closed.
Manual beam blocks are in place.
Enclosure interlock is enabled.
  
  866   Thu Aug 21 16:28:59 2008 steveConfigurationSAFETYsafety glasses required I just opened the MOPA shutter so PA is warming
up.
  
  871   Fri Aug 22 16:06:29 2008 steveUpdatePEMparticle counter replaced, flowbenches & HEPAs checkedMetOne #2 counter was swapped in (on the top
of IOC, facing SW direction, at ~75 deg upwards)
with channel one size 0.3 micron and channel
  
  875   Mon Aug 25 10:23:53 2008 steveHowToGeneralcable killerRack 1Y7 double violation:

BNC cables left to be jammed by door
 cablkill.pngcablkll2.png 
  876   Mon Aug 25 10:51:06 2008 steveUpdatePSLpsl headtemp is coming downThe laser water cooler was overflowing this
morning.
I removed 500 cc water from the chiller.
 ht4dw.jpg 
  885   Tue Aug 26 09:58:59 2008 steveOmnistructureCOCETMX is #03This is the picture of ETMX from the upper
south west viewport
 etmx-d40posg_012.jpgetmx03.jpg 
  887   Tue Aug 26 15:06:16 2008 steveConfigurationVACrga scanPumpdown 66 PRM-maglev vac normal -day 11
short form: pd66PRM-m-d11
 RGA-0808260125.png 
  901   Fri Aug 29 15:01:45 2008 steveUpdatePSLMOPA_HTEMP in increasingThe laser chiller temp is 21.9C ( it should
be 20.0C )
Control room temp 73F ok, no obvious block
 htcl.jpg 
  911   Tue Sep 2 10:09:03 2008 steveUpdatePSLhead temp is cooling downThe chiller was over flowing this morning.
800 cc of water was removed.
PSL-126MOPA_HTEMP peaked at 20.7 C (normal
  
  931   Fri Sep 5 08:34:03 2008 steveUpdatePSLMZ lockedThe MC is happy.
The MZ can be locked if you move the slider
by hand.
 mzhv.jpg 
  933   Fri Sep 5 10:36:34 2008 steveUpdatePEMthermostate setting changedSome one changed the thermostat (old control
room ) setting behind 1Y6 from 73 to 79F
It should be in the elog.
  
  935   Mon Sep 8 10:57:49 2008 steveUpdateIOOthe psl and mc are back to normalThe alarm handler is silent this morning.
This is almost unbelievably pleasant after
two mount of harassment.
 fss.pngpmcbrick.pngbrick.jpg 
  936   Mon Sep 8 13:47:35 2008 steveUpdatePEMthermostate setting changed[quote][quote]Some one changed the thermostat
(old control room ) setting behind 1Y6 from
73 to 79F
  
  938   Wed Sep 10 08:57:03 2008 steveUpdateGeneraletmy illuminator turned offThe ETMY illuminator was left on yesterday.
I just turned it off.
  
  942   Thu Sep 11 14:27:53 2008 steveBureaucracySAFETYsafety trainingPeter Kalmus received 40m specific safety
training last week.
  
  962   Thu Sep 18 09:30:12 2008 steveUpdateGenerallow noise metal film resistors are inLow noise metal film resistor and capacitor
kits from www.garrettelec.com are in.
 mfr&cap.pngstorcab.png 
  971   Fri Sep 19 08:09:55 2008 steveUpdatePSLpsl HEPAs turned onI have just turned on the PSL HEPA filters
at 60% operational speed.
  
  974   Fri Sep 19 11:48:14 2008 steveUpdateComputers old hubs can make one happyJoseph finds a XIX century bottle neck hub:
CentreCOM 3624TR 10Base-T 
and happily replaces it with Netgear GS724T
 P1020934.jpg 
  984   Tue Sep 23 11:17:59 2008 steveUpdatePSLPMC scattering spotThe PMC output side has a new madly scattering
spot at chamfer 2 o'clock position
 rainbow.pngpmcclip.png 
  996   Fri Sep 26 09:05:47 2008 steveUpdateSUSMC2 damping restoredThe MC2 sus damping was restored.   
  1004   Mon Sep 29 11:17:14 2008 steveUpdateSAFETYhorizontal viewports are protected with lexanThe four horizontal viewports of arms are
protected 
by 3/8" thick, 8.5" OD Lexan disk of MR10
  
  1007   Mon Sep 29 15:09:36 2008 steveUpdatePSLalmost 4 yrs plot of power & tempsThe water chiller is normally running 1.5
C warmer than the laser head temp.
When control room temp is stable and PEM-count_temp
 3.5y.jpg 
  1020   Thu Oct 2 16:44:28 2008 steveSummaryoplevsoptical leversThe idea is to push the  UGF to 10 Hz of the
TM oplev servos with quiet HeNe laser.
We measured good intensity noise of JDS 1103P
  
  1027   Mon Oct 6 10:00:49 2008 steveUpdateMOPAMOPA_HTEMP is upMonday morning conditions:

The laser head temp is up to 20.5 C
 htup.jpg 
  1057   Mon Oct 20 09:45:56 2008 steveUpdatePEMPSL HEPA onThe PSL HEPA filter was turned on.
It should be running all times.
The 0.5 micron particle count is up to 20,000
  
  1062   Tue Oct 21 16:14:42 2008 steveUpdateGeneraldivergence of He Ne 1035PThe ITM oplevs laser diodes are noisy.
They will be replaced by JDS 1035P
SN T8093307 was measured with the beamscanner.
 1035p_divergence.png 
  1068   Wed Oct 22 16:22:53 2008 steveBureaucracySAFETYCaryn received safety trainingCaryn Polatchi has received 40m safety training
on Monday, Oct 20
  
  1071   Thu Oct 23 11:26:25 2008 steveBureaucracyVACoptosigma forks for vacuumNine short forks from OptoSigma were cleaned,
baked and measured by Bob T.
They passed the LIGO vac compatiblity test
  
  1082   Fri Oct 24 11:09:08 2008 steveUpdateSAFETYmore lexan plates under camerasThe MC2, MC3&1 and BSC-SUS cameras were repositioned
somewhat in the 
process of placing lexan disks under neat
  
  1085   Fri Oct 24 15:05:13 2008 steveUpdateVACrga is out of orderThe old Dycor  RGA is out of order.
I'm getting ready to purchase an SRS instrument.
  
  1094   Mon Oct 27 11:23:10 2008 steveUpdatePhotosnew Olympus camera with IR visionThe IR blocker was removed from our new Olympus
camera 
SP 570UZ camera.
 IRisin.JPG 
  1103   Fri Oct 31 08:52:19 2008 steveUpdateSUSETMY damping restoredETMY watchdogs were tripped yesterday morning
also. This is a problem that existed some
months ago.(?)
 etmy2d.jpg 
  1107   Mon Nov 3 09:59:47 2008 steveUpdatePSLPSL HEPAs turned onThe psl [COLOR=chocolate]enclosure[/COLOR]
HEPAs were tuned on.
  
  1116   Thu Nov 6 09:45:27 2008 steveUpdateMOPAhead temp hick-up vs power The control room AC temp was lowered from
74F to 70F around Oct 10
This hold the head temp rock solid 18.45C
 htpr.jpg 
  1117   Thu Nov 6 10:06:41 2008 steveUpdateLockingarms lock degradationI have been locking the arms in the mornings
lately.
The daily drift of LSC-TRX is ~ 15% and LSC-TRY
 arms.jpg 
  1120   Fri Nov 7 08:08:00 2008 steveUpdatePEMAC turned off in IFO roomAll [COLOR=red]tree[/COLOR] AC units in IFO
room 104 switched off at 7:45am
I'm looking for the periodic thump signal
  
  1121   Fri Nov 7 10:52:57 2008 steveUpdatePEMAC is back onThe 20 minutes and 6 sec thumps are not related
to the 40m ac units
This period is precisely right on so it is
 acf.jpgacc_mc1.jpgtest.jpg 
ELOG V3.1.3-