40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 316 of 341  Not logged in ELOG logo
ID Date Author Type Category Subjectdown Text Attachments
  12503   Sun Sep 18 16:18:05 2016 ranaUpdateSUSAlignment statussusaux is responsible for turning on/off
the inputs to the coil driver, but not the
actual damping loops. So rebooting susaux
  
  12504   Mon Sep 19 11:11:43 2016 ericqUpdateSUSAlignment status[ericq, Steve]

ITMX is free, OSEM signals all
rougly centered. 
  
  7534   Fri Oct 12 01:56:26 2012 kiwamuUpdateGeneralAlignment situation of interferometer [Koji / Kiwamu]
 We have realigned the interferometer
except the incident beam.
  
  1210   Thu Jan 1 00:55:39 2009 YoichiUpdateASCAlignment scripts for LinuxA Happy New Year.

The dither alignment scripts did not run
  
  14422   Tue Jan 29 22:12:40 2019 gautamUpdateSUSAlignment prepSince we may want to close up tomorrow,
I did the following prep work:


Cleaned up Y-end suspension
  
  14211   Sun Sep 23 17:38:48 2018 yukiUpdateASCAlignment of AUX Y end green beam was recovered[ Yuki, Koji, Gautam ]

An alignment of AUX Y end green
beam was bad. With Koji and Gautam's
  
  726   Wed Jul 23 18:42:18 2008 JenneUpdatePSLAlignment of AOM[Rana, Yoichi, Jenne]

Short Version:  We are selecting the wrong
  
  7573   Thu Oct 18 03:57:20 2012 JenneUpdateLockingAlignment is really bad??The goal of the night was to lock the Y
arm.  (Since that didn't happen, I moved
on to fixing the WFS since they were hurting
  
  7581   Fri Oct 19 16:24:39 2012 ranaUpdateLockingAlignment is really bad?? 
 VENT
  
  3847   Tue Nov 2 16:24:07 2010 KojiUpdateAuxiliary lockingAlignment for the green in the X trans table [Kiwamu Koji]
Today we found the green beam
from the end was totally missing at the vertex.
  
  7673   Tue Nov 6 16:38:37 2012 jenne, jamie, ayaka, manasaUpdateAlignmentAlignment back under control againWe had a big alignment party early this
morning, and things are back to looking good. 
We have been very careful not to bump or
  
  7291   Tue Aug 28 00:16:19 2012 jamieUpdateGeneralAlignment and vent prepI think we (Jenne, Jamie) are going to
leave things for the night to give ourselves
more time to prep for the vent tomorrow.
 as1.png 
  10534   Wed Sep 24 18:17:46 2014 ericqUpdateGeneralAlignment RestoredInterferometer
alignment is restored
ASS has been run on each arm, recycling
  
  1793   Sun Jul 26 13:19:54 2009 ranaUpdatePSLAligning the mode cleanerI set the MC back to its good alignment
(June 21st) using this
procedure. The trend of the OSEM values
 Untitled.png 
  1794   Sun Jul 26 16:05:17 2009 AlbertoUpdatePSLAligning the mode cleaner


   
        
            
  
  1795   Mon Jul 27 09:34:07 2009 steveSummaryIOOAligning the mode cleaner


   
        
            
 20dtrend.jpg 
  1788   Fri Jul 24 21:02:46 2009 AlbertoUpdatePSLAligning the beam to the FaradayThis afternoon I kept working on the alignment
of the beam so that it matches at the same
the PSL periscope, the Mode Cleaner and the
  
  1791   Sat Jul 25 16:04:32 2009 robUpdatePSLAligning the beam to the Faraday


   
        
            
  
  1792   Sat Jul 25 19:04:01 2009 KojiUpdatePSLAligning the beam to the Faraday


   
        
            
 MC2_Cam.jpg 
  14337   Mon Dec 10 12:11:28 2018 aaronUpdateOMCAligning the OMCI did some ray tracing and determined that
the aux beam will enter the OMC after losing
some power in reflection on OMPO (couldn't
 B9DCF55F-1355-410C-8A29-EE45D43A56A4.jpeg 
  14343   Tue Dec 11 14:24:18 2018 aaronUpdateOMCAligning the OMCI set up a function generator to drive
OMC-L, and have the two DCPD mons and the
OMC REFL PD sent to an oscilloscope. I need
  
  14346   Tue Dec 11 22:50:07 2018 aaronUpdateOMCAligning the OMCI did the following:


Noticed that the OMC rack's
power has +-18V, but I had tested
 6x 
  14355   Thu Dec 13 22:36:42 2018 aaronUpdateOMCAligning the OMCI turned on AUX, and aligned the aux beam
to be centered on the first optic the AS
beam sees on the AP table. I then turned
  
  14357   Fri Dec 14 13:02:24 2018 aaronUpdateOMCAligning the OMCI replaced the 2'' AUX-AS combining
BS with a 2'' HR mirror for 1064.
I aligned the AUX beam from the new HR mirror
  
  14358   Fri Dec 14 13:06:12 2018 aaronUpdateOMCAligning the OMCI replaced the 2'' AUX-AS combining
BS with a freshly mounted 2'' HR
mirror for 1064. The mirror is labelled 'Y1-2037-45-P',
  
  14363   Mon Dec 17 20:45:40 2018 aaronUpdateOMCAligning the OMC[gautam, aaron]

We did work in the OMC chamber
today to get the OMC aligned. Aaron was in
 IMG_5922.JPGIMG_5921.JPG 
  5182   Thu Aug 11 04:45:07 2011 SureshUpdateIOOAligning the 1064nm beam with the in-vacuum pzt's[Kiwamu, Suresh]
We worked on the beam path from MC
to BS this evening. 
 FI_input_spot.jpg 
  7579   Fri Oct 19 01:21:42 2012 EvanUpdateLockingAligning PZTs, PRM[Evan, Jenne]
Tonight we made an attempt at getting
the PRM + ITMY aligned with correct input
  
  4116   Wed Jan 5 23:22:00 2011 JenneUpdateCamerasAligned the Xarm, no big deal[Kiwamu, Jenne]
We successfully aligned the X arm. 
No big deal.  Nothing to 
 DSC_2822.JPGKiwamuJenne_5Jan2011_Xarm_Aligned.png 
  4117   Wed Jan 5 23:37:12 2011 ranaUpdateCamerasAligned the Xarm, no big dealPretty fancy work actually...I wouldn't
have guessed that you need to look at the
back of the ETM. Does this mean that we can't
  
  4118   Wed Jan 5 23:45:33 2011 JenneUpdateCamerasAligned the Xarm, no big dealCorrect.  We can see the flashes clearly
on our new ETM camera, but we see absolutely
nothing on the ITM.
  
  4119   Thu Jan 6 00:03:05 2011 KojiUpdateCamerasAligned the Xarm, no big dealNice, nice! 
The power budget for the FPMI is
  
  3804   Thu Oct 28 03:21:35 2010 SureshUpdateLockingAligned the MC2 transmission photodiodeYuta and
Suresh
  
  2318   Mon Nov 23 21:36:38 2009 KojiUpdateIOOAligned PMC/RCI aligned the beam goes to PMC. It increased
the MC Trans from 8.25 to 8.30.
I also aligned the beam goes to RC.
 091123_PSL.png 
  10724   Mon Nov 17 23:04:51 2014 JenneUpdatePSLAligned PMCI aligned the beam into the PMC, mostly
in yaw.  Don't know why it drifted,
but it was annoying me, so I fixed it.
  
  8101   Mon Feb 18 23:41:15 2013 SendhilUpdateAlignmentAligned IPPOS, IPANG and OPLEVS[Yuta, Sendhil]
We aligned IPPOS, IPANG and all OPLEVs
(except for ETMX and SRM).
 IPANGIPPOSoplevs.png 
  14151   Thu Aug 9 22:50:13 2018 gautamUpdateCDSAlignSoft script modifiedAfter this
work of increasing the series resistance
on ETMX, there have been numerous occassions
 MichelsonFringing.png 
  683   Wed Jul 16 16:59:07 2008 AlbertoUpdateGeneralAligmentI think the two beams are aligned again -
they both pass the Faraday, they match at
the irises and all along the optical path
  
  7101   Tue Aug 7 11:46:24 2012 JamieUpdateCDSAlex working on daqdAlex is apparently working on daqd (remotely). 
I'll report back when I find out more.
  
  3836   Mon Nov 1 14:53:30 2010 josephb, alex, rolfUpdateCDSAlex updated FB and mx_streams codeProblem:
The framebuilder was being flaky. 
MX_streams would go down, prevent testpoints
  
  1159   Mon Nov 24 16:43:34 2008 ranaConfigurationComputersAlex and Jay took away some computers from the racksI was over at Wilson house and saw Jay and
Alex bring in 3 rackmount computers. One
was a Sun 4600 and
  
  4758   Sat May 21 17:02:38 2011 KojiUpdateElectronicsAlberto's 11MHz was modified to POP55MHz- Resonant at 55MHz. The transimpedance
is 258Ohm. That is about half of REFL55 (don't
know why).
 POP55_schematic_110520_KA.pdfPOP55_transimpedance.pdf 
  15634   Mon Oct 19 15:40:02 2020 KojiUpdatePEMAlaska EQ M7.5Alaska M7.5 20:54UTC https://earthquake.usgs.gov/earthquakes/eventpage/us6000c9hg/executive

I looked at the suspensions. The
  
  1766   Tue Jul 21 01:11:30 2009 DmassAoGComputersAlarms going offI came into the 40m to sign things out
briefly then swiftly return them, and the
alarms were going off on op540m at 1am.
  
  14863   Fri Sep 6 16:38:24 2019 aaronUpdateALARMAlarm noise from smart-ups machine under workstation?There was an alarm sound from the Smart-UPS
2200 sitting under the workstation. I see
that the 'replace battery' light
  
  14864   Fri Sep 6 18:08:29 2019 ranaUpdateComputersAlarm noise from smart-ups machine under workstation?please no one touch
the UPS: last time it destroyed ROSSA.
Please ask Chub to order the replacement
  
  644   Tue Jul 8 00:14:28 2008 JohnSummaryComputersAlarm handlerRob thought it would be nice to have some
alarms on the cpu loads and FE syncs.
I added all these channels to the alarm handler
  
  571   Thu Jun 26 01:10:18 2008 ranaUpdatePEMAlarm Handler indicates that dust level is high[I]In its first useful act[/I], the Alarm
Handler started beeping indicating that the
[COLOR=purple]dust particle
 Untitled.png 
  570   Thu Jun 26 01:08:22 2008 ranaConfigurationGeneralAlarm Handler RevivedI have revived the Alarm Handler by turning
it on on op540m and adjusting the levels
of
 b.gif 
  578   Thu Jun 26 20:59:22 2008 ranaUpdateComputer Scripts / ProgramsAlarm Handler[COLOR=red][SIZE=5][B]Please do not turn off
the Alarm Handler on op540m.[/B][/SIZE][/COLOR]
  
ELOG V3.1.3-