  1919   Mon Aug 17 09:52:04 2009 robSummaryGeneralconlogger restartedI restarted the conlogger on op340m. 
This needs to be done when op340m is rebooted--it
wasn't done for some reason and so we've
  
  1921   Mon Aug 17 17:48:49 2009 robSummaryGeneralconlogger restarted


   
        
            
  
  1924   Tue Aug 18 15:16:15 2009 robUpdateIOOMC WFS working againRob, Yoichi
 
The MC WFS have apparently been bad
  
  1930   Wed Aug 19 23:57:35 2009 robUpdateLockingreport 
locking work proceeding apace tonight.
diagonalized DRM with setDDphases
  
  1960   Fri Aug 28 13:49:07 2009 robUpdateLockingRF CARM hand off problem[quote]Last night,  the lock script proceeded
to the RF CARM hand-off about half of the
time.
  
  1989   Thu Sep 17 14:17:04 2009 robUpdateComputersawgtpman on c1omc failing to start[root@c1omc controls]# /opt/gds/awgtpman
-2 &
[1] 16618
  
  1990   Thu Sep 17 15:05:47 2009 robUpdateComputersawgtpman on c1omc failing to start


   
        
            
  
  1991   Fri Sep 18 14:25:00 2009 robOmnistructurePSLwater under the laser chillerrob, koji, steve
We noticed some water (about a cup)
on the floor under the NESLAB chiller today. 
  
  1994   Wed Sep 23 17:32:37 2009 robAoGComputersGremlins in the RFMA cosmic ray struck the RFM in the framebuilder
this afternoon, causing hours of consternation. 
The whole FE system is just now coming back
  
  1997   Thu Sep 24 15:45:27 2009 robUpdateIOOMC OLGI measured the mode cleaner open loop gain
with the HP3563A. 
  
  2013   Mon Sep 28 17:39:34 2009 robUpdatePSLproblemsThe PSL/IOO combo has not been behaving
responsibly recently. 
The first attachment is a 15 day
 problems.pngproblems2.png 
  2016   Tue Sep 29 01:50:10 2009 robConfigurationLSCnew modulation frequenciesMode cleaner length measured tonight.
 
33196198
  
  2019   Tue Sep 29 16:14:44 2009 robConfigurationElectronicsRob is breaking stuff....


   
        
            
  
  2024   Tue Sep 29 23:43:46 2009 robUpdateSUSITMY UL OSEMWe had a redo of elog entry 975
tonight.  The noisy OSEM was fixed by
jiggling the rack end of the long cable. 
 ITMYosemBAD.pdf 
  2026   Wed Sep 30 01:04:56 2009 robUpdateComputersgriefmuch grief.  somehow a burt restore
of c1iscepics failed to work, and so the
LSC XYCOM settings were not correct. 
 C1LSC_XYCOM.jpg 
  2027   Wed Sep 30 02:01:28 2009 robUpdateLockingweekIt's been a miserable week for lock acquisition,
with each night worst than the last. 
The nadir was around Sunday night, when I
 srmcpu.png 
  2030   Thu Oct 1 03:12:56 2009 robUpdateLockingsome progressGood progress in IFO locking tonight, with
the arm powers reaching about half the full
resonant maximum. 
  
  2036   Thu Oct 1 14:22:28 2009 robUpdateSUSall suspensions undamped

    
        
  
  2037   Thu Oct 1 15:42:55 2009 robUpdateLockingc1susvme2 timing problems update

    
        
 srmcpu2.png 
  2040   Fri Oct 2 02:55:07 2009 robUpdateLockingmore progressMore progress with locking tonight, with
initial acquisition and power ramps working. 
The final handoff to RF CARM still needs
  
  2042   Fri Oct 2 15:11:44 2009 robUpdateComputersc1susvme2 timing problems update updateIt got worse again, starting with locking
last night, but it has not recovered. 
Attached is a 3-day trend of SRM cpu load
 srmcpu3.png 
  2045   Fri Oct 2 18:04:45 2009 robUpdateCDSDTT no good for OMC channelsI took the output of the OMC DAC and plugged
it directly into an OMC ADC channel to see
if I could isolate the OMC DAC weirdness
 omc_dac_dtt.pngomc_dac_sweepTDS.pngomc_dac_dtt_ts.png 
  2046   Fri Oct 2 18:26:32 2009 robAoGEnvironmentearthquakequake coming through.  I've re-enabled
optic damping (except ETMY), and left off
the oplevs for now.  We can do a resonant-f 
 California_Nevada.gif 
  2047   Sat Oct 3 14:53:24 2009 robUpdateLockingmore progressLate last night after the ETMY settled
down from the quake I made some more progress
in locking, with the handoff to RF CARM succeeding
  
  2048   Mon Oct 5 02:51:08 2009 robUpdateLockingalmost thereWorking well tonight: the handoff of CARM
to RF (REFL2I), successful reduction of CARM
offset to zero, and transition control of
  
  2056   Tue Oct 6 01:41:20 2009 robUpdateLockingDC Readout Lock acquisition working well tonight. 
Was able to engage CM boost (not superboost)
with bandwidth of ~10kHz.  Also succeeded
  
  2080   Mon Oct 12 14:51:41 2009 robUpdateComputersc1susvme2 timing problems update update update

    
        
 srmcpu.png 
  2081   Mon Oct 12 17:14:39 2009 robUpdateLockingstabilityLast night, 2+ hour lock, probably broken
by me driving too hard (DARM_EXC).
 transpow.png 
  2092   Wed Oct 14 16:59:37 2009 robUpdateLockingdaytime lockingThe IFO
can now be locked during the daytime. 
  
  2105   Fri Oct 16 16:08:00 2009 robConfigurationASCloop opened on PZT2 YAW at 3:40 pmI pushed the "closed loop" button
on PZT2 YAW around 3:40 pm today, then roughly
recentered it using the DC Offset knob on
  
  2120   Mon Oct 19 18:14:28 2009 robUpdateCamerasvideo switch brokenThe Chameleon HB (by Knox) video switch
that we use for routing video signals into
the control room monitors is broken. 
  
  2123   Tue Oct 20 02:14:29 2009 robUpdateIOOMC2 alignment bias changedthe mode cleaner was having trouble locking
in a 00 mode, needing several tries. 
I changed the MC2 coil biases, and it seems
  
  2126   Tue Oct 20 16:35:24 2009 robConfigurationLSC33MHz Mod depthThe 33MHz mod depth is now controlled by
the OMC (C1:OMC-SPARE_DAC_CH_15).  The
setting to give us the same modulation depth
  
  2138   Fri Oct 23 15:02:00 2009 robUpdateloremarconi phaseSo, it appears that one doesn't even have
to change the Marconi set frequency to alter
the phase of the output signal.  It
  
  2141   Mon Oct 26 03:57:06 2009 robUpdateLockingbadLock acquisition has gone bad tonight. 
The initial stage works fine, up
through handing off control of CARM to MCL. 
  
  2144   Mon Oct 26 18:15:57 2009 robUpdateIOOMC OLGI measured the mode cleaner open loop gain. 
It's around 60kHz with 29 degs of phase margin.
  
  2148   Tue Oct 27 01:45:02 2009 robUpdateLockingMZ[quote] Tonight we also encountered a large
peak in the frequency noise around 485 Hz.
 Changing the MZ lock point (the spot in
  
  2151   Tue Oct 27 18:01:49 2009 robUpdatePSLhmmmA 30-day trend of the PCDRIVE from the
FSS.
 pcdrive_trend.png 
  2152   Tue Oct 27 18:19:14 2009 robUpdateLockingbad

    
        
 MCF_issue.pngno_MCF_issue.png 
  2154   Wed Oct 28 05:02:28 2009 robUpdateLockingbackLockAcq is back on track, with the full
script working well.  Measurements in
progress.
  
  2162   Thu Oct 29 21:51:07 2009 robUpdateLockingbad

    
        
 itsback.png 
  2163   Fri Oct 30 04:41:37 2009 robUpdateLockingworking againI never actually figured out exactly what
was wrong in entry 2162,
but I managed to circumvent by changing the
  
  2221   Mon Nov 9 18:32:38 2009 robUpdateComputersOMC FE hosedIt won't start--it just sits at Waiting
for EPICS BURT, even though the EPICS is
running and BURTed.
  
  2222   Mon Nov 9 19:04:23 2009 robUpdateComputersOMC FE hosed


   
        
            
  
  2287   Tue Nov 17 21:21:30 2009 robUpdateSUSETMY UL OSEMHad been disconnected for about two weeks. 
I found a partially seated 4-pin LEMO cable
coming from the OSEM PD interface board. 
  
  2309   Fri Nov 20 16:18:56 2009 robConfigurationSUSwatchdog rampdownI've changed the watchdog rampdown script
so it brings the SUS watchdogs to 220, instead
of the 150 it previously targeted. 
  
  2325   Wed Nov 25 03:05:15 2009 robUpdateLockingMeasured MC length

    
        
  
  2332   Wed Nov 25 14:29:08 2009 robUpdateLockingMeasured MC length--FSS trend

    
        
 FSStrendpowerjump.png 
  2333   Wed Nov 25 15:38:08 2009 robUpdateLockingMeasured MC length

    
        
  
  2344   Sun Nov 29 16:56:56 2009 robAoGall down cond.sea of redCame in, found all front-ends down.
 
Keyed a bunch of crates, no luck:
  
ELOG V3.1.3-