  16043   Fri Apr 16 15:47:58 2021 ranaUpdateSUSTested proposed filters for POS colum in MC2 output matrixLooks mostly right, but you
used the OSEM sensors as readbacks.
  
  16042   Fri Apr 16 11:36:36 2021 Anchal, PacoUpdateSUSTested proposed filters for POS colum in MC2 output matrixWe tried two sets of filters on the output
matrix POS column in MC2. Both versions failed.
Following are some details.
 20210416_MC2DCcoilBalancingNoFilters.pdfuncFilters.pdf20210416_MC2DCcoilBalancingWithFilters.pdfuncFilters_v2.pdf20210416_MC2DCcoilBalancingWithFilters_v2.pdf 
  16041   Fri Apr 16 11:31:00 2021 ranaUpdateelogelog stuck ~10 AM todayfound it unresponsive. Restarted fine using
procedure documented in wiki
  
  16040   Fri Apr 16 10:58:16 2021 YehonathanUpdateGeneralGlue Freezer completely frozen{Paco, Anchal, Yehonathan}

We emptied the fridge and moved
the amplifier equipment on top of the amplifier
 20210416_105048.jpg 
  16039   Fri Apr 16 00:21:52 2021 KojiUpdateGeneralGlue Freezer completely frozenI was looking at the laser head/amp and
somehow decided to open the glue freezer.
And it was stuck. I've managed to open
 P_20210416_000906.jpgP_20210416_000850.jpg 
  16038   Thu Apr 15 18:33:39 2021 KojiUpdateCDSMore 16bit ADC adapter boardsWe received 10x 16bit ADC adapter boards
from Todd. S2100687~S2100696

The number of soldered resistors
 P_20210415_183139_1.jpg 
  16037   Thu Apr 15 17:24:08 2021 JonUpdateCDSUpdated c1auxey wiring planI've updated the c1auxey wiring
plan for compatibility with the new suspension
electronics. Specifically it is based on
 C1AUXEY_Chassis_Feedthroughs_-_By_Connector.pdf 
  16036   Thu Apr 15 15:54:46 2021 gautamUpdateIOOWaveplate commissioning - hardware installed[jordan,
gautam]
  
  16035   Thu Apr 15 11:41:43 2021 AnchalUpdateSUSProposed filters for output matrix aka F2A aka F2PHere' s aquick update before we leave
for lunch. We have managed to calculate some
filter that would go on the POS column in
 MC2propPOSfb.pdf 
  16034   Thu Apr 15 09:46:24 2021 YehonathanUpdatePSLLaser amplifierSome more relevant documents provided by
Matt:

Phase
  
  16033   Wed Apr 14 23:55:34 2021 gautamUpdateElectronicsHV Coil driver assemblyI've occcupied the southernmost electronics
bench for assembling the 4 production version
HV coil driver chassis. I estimate it will
  
  16032   Wed Apr 14 19:48:18 2021 gautamUpdatePSLLaser amplifierA couple of years ago, I got some info
about the amplifier setup at the sites from
Terra - sharing here in case there is some
  
  16031   Wed Apr 14 17:53:38 2021 AnchalUpdateSUSPlan for calculating filter banks for output matrix aka F2A aka F2PPlan of action


Get
the transfer functions of the suspension
plant from actuated DOF to sensed DOF. We'll
 MC2propF2A_UL.pdf 
  16030   Wed Apr 14 16:46:24 2021 AnchalUpdateGeneralIFO StateThat makes sense. I assumed that IFO-STATE
is configured as you have proposed it to
be configured. This could be implemented
  
  16029   Wed Apr 14 15:30:29 2021 ranaUpdateGeneralSorry, it was meMaybe tighten the tensioner on the door
closer so that it closes by itself even in
the low velocity case. Or maybe just use
  
  16028   Wed Apr 14 14:52:42 2021 gautamUpdateGeneralIFO StateThe C1:IFO-STATE
variable is actually a bunch (16 to be precise)
 IFOSTATE.png 
  16027   Wed Apr 14 13:16:20 2021 AnchalConfigurationComputers40m Control Room Changes
I have confirmed that the old two
monitors' backlighting is not working.
One can see the impression of the display
  
  16026   Wed Apr 14 13:12:13 2021 AnchalUpdateGeneralSorry, it was meSorry about that. It must be me. I'll
make sure it doesn't happen again. I
was careless to not check back, no further
  
  16025   Wed Apr 14 12:27:10 2021 gautamUpdateGeneralLab left open againOnce again, I found
the door to the outside in the control room
  
  16024   Tue Apr 13 20:45:16 2021 YehonathanUpdatePSLLaser amplifier{Yehonathan, Rana}

We unpacked the content of the
amplifier crate in front of the water fountain
 20210413_204721.jpg20210413_203300.jpg20210413_204940.jpg20210413_205549.jpg 
  16023   Tue Apr 13 19:24:45 2021 gautamUpdatePSLHigh power operationsWe (rana, yehonathan and i) briefly talked
about having high power going into the IFO.
I worked on some calcs a couple of years
 intensityDist.pdfclippingLoss.pdf 
  16022   Tue Apr 13 17:47:07 2021 gautamUpdateIOOWaveplate commissioning - software preparedI spent some time today setting up a workable
user interface to control the waveplate.


Created some EPICS database
 remoteHWP.png 
  16021   Tue Apr 13 16:24:38 2021 Ian MacMillanUpdateCDS40m LSC simPlant modelAdded Matlab to the Docker machine. This
should help immensely with workflow as well
as keeping installed libraries consistent.
  
  16020   Tue Apr 13 09:51:22 2021 ranaUpdateSUSWhat's F2A??Force to Angle. It just means the filters
that are in the POS OUTPUT matrix. I think
in the past sometimes they are called F2P
  
  16019   Mon Apr 12 18:34:26 2021 YehonathanSummaryPSLPMC unlocked at 2pm on Sunday; ~ RestoredPMC lost lock again at around 16:00 April
12. I was able to lock it again but the transmission
is only 0.6 now and REFL is 0.14.
  
  16018   Mon Apr 12 17:30:11 2021 YehonathanUpdateBHDSOS assemblyToday, I screwed the plungers on the sensor
plates and installed them on the Towers.
I also installed the wire clamps on the suspension
 20210412_170913.jpg 
  16017   Mon Apr 12 10:07:35 2021 AnchalUpdateSUSWhat's F2A??I'm not sure I understand what F2A
is? I couldn't find a description of
this filter anywhere and don't remember
  
  16016   Mon Apr 12 08:32:54 2021 Anchal, PacoSummaryPSLPMC unlocked at 2pm on Sunday; ~ RestoredPMC lost lock between 21:00 and 22:00 UTC
on April 11th as seen in the summary pages:

https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20210411/psl/#gallery-4
  
  16015   Sat Apr 10 11:56:14 2021 JonUpdateCDS40m LSC simPlant modelSummary

Yesterday I resurrected
the 40m's LSC simPlant model, c1lsp.
 x1lsp_main.png 
  16014   Sat Apr 10 10:07:47 2021 ranaUpdateSUSFaster coil balancingI think I mis-spoke about the balancing
channels before. The ~20 Hz balancing
could go into either the COIL banks or the
  
  16012   Sat Apr 10 08:51:32 2021 JonUpdateCDSI/O Chassis AssemblyI installed three of the 16-bit ADC adapter
boards assembled
by Koji. Now, the only missing hardware is the
  
  16011   Fri Apr 9 20:54:54 2021 YehonathanUpdateBHDSOS assemblyToday I assembled the skeleton of 6 towers,
without clamps and sensor assembly (attachment
1).
 20210409_202717.jpg20210409_202755.jpg 
  16010   Fri Apr 9 17:41:12 2021 ranaUpdateSUSFaster coil balancingconvergence is great.

Next we wanna get the F2A filters
made since most of the IMC control happens
  
  16009   Fri Apr 9 13:13:00 2021 Anchal, PacoUpdateSUSFaster coil balancingWe ran again this method but with the 'b'
parameter as a matrix instead. This provides
more gain on some off-diagonal terms than
 SmatIterations.pdfMC2AllOutmat.txt 
  16008   Thu Apr 8 20:58:17 2021 KojiUpdateCDSADC adapter boards assembly5x 16bit ADC adapter boards (D0902006)
assembled.
 P_20210408_205411_2_1.jpg 
  16007   Thu Apr 8 17:04:43 2021 Anchal, PacoUpdateSUSFirst Successful Coil BalancingToday, we finally crossed the last hurdle
and got a successful converging coil balancing
run. 
 SDistanceFromIdentity.pdfSmatIterations.pdfSmatrixPlots.pdf 
  16006   Wed Apr 7 22:48:48 2021 gautamUpdateIOOWaveplate commissioningSummary:

I spent an hour today evening checking
out the remote waveplate operation. Basic
 remotePowCtrl.pdf 
  16005   Wed Apr 7 17:38:51 2021 AnchalUpdateSUSTrying to uncouple only PIT and YAW firstTo test if our method is working at all,
we went for the simpler case of just uncoupling
PIT and YAW. This is also because the sensor
 SDistanceFromIdentity.pdfSmatIterations.pdfTimeSeriesPlots.pdfCSDPlots.pdfSmatrixPlots.pdf 
  16004   Wed Apr 7 13:07:03 2021 JordanUpdateSUSCoM on 3"->2" Adapter Ring for SOSAdding the chamfer around the edge of the
optic ring did not change the center of mass
relative to the plane from the suspension
 CoM_with_Chamfer.pngMoments_of_Inertia.PNG 
  16003   Wed Apr 7 02:50:49 2021 KojiUpdateSUSFlange InspectionsBasically I went around all the chambers
and all the DB25 flanges to check the invac
cable configurations. Also took more time
  
  16002   Tue Apr 6 21:17:04 2021 KojiSummaryGeneralPSL HEPA investigation- Last week we found both of the PSL HEPA
units were not running.

- I replaced the capacitor of the
 20210406211741_IMG_0554.jpeg20210406211840_IMG_0555.jpeg20210406211850_IMG_0556.jpeg 
  16001   Tue Apr 6 18:46:36 2021 Anchal, PacoUpdateSUSUpdates on recent effortsAs mentioned in last post, we earlier made
an error in making sure that all time series
arrays go in with same sampling rate in CSD
 FirstMeasurementPlots.pdf 
  15999   Tue Apr 6 15:42:57 2021 YehonathanUpdateBHDSOS assemblyWe got some dumbells from Re-Source Manufacturing
(see attached). I picked 3 in random and
measured their dimensions:
 20210406_150724.png 
  15998   Tue Apr 6 11:13:01 2021 JonUpdateCDSFE testingI/O chassis assembly

Yesterday
I installed all the available ADC/DAC/BIO
modules and adapter boards into the new I/O
  
  15997   Tue Apr 6 07:19:11 2021 JonUpdateCDSNew SimPlant cymacYesterday Chris and I completed setup of
the Supermicro machine that will serve as
a dedicated host for developing and testing
  
  15996   Mon Apr 5 22:26:01 2021 gautamUpdateLSCPRMI 1f locking (no ETMs) recoveredSince it seems like the entire electronics
chain has no obvious failure, I decided to
compensate for the apparent increased optical
 PRMI_Apr5sensMat_consolidated.pdf 
  15995   Mon Apr 5 08:25:59 2021 Anchal, PacoUpdateGeneralRestore MC from early quakes[Paco, Anchal]

Came in a little bit after 8 and
found the MC unlocked and struggling to lock
  
  15994   Sat Apr 3 00:42:40 2021 gautamUpdateLSCPRFPMI locking with half input powerSummary:

I wanted to put my optomechanical
instability hypothesis to the test. So
 PRFPMIlock_1301464998_1301465238.pdfCARMplant.pdf 
  15993   Fri Apr 2 15:22:54 2021 gautamUpdateSUSMatrix results, new measurement set to triggerHow should I try to understand why PIT
and YAW are so different? 

  
  15992   Fri Apr 2 15:17:23 2021 gautamSummaryGeneralHEPA AC cord replacementFrom the last failure, I had ordered 2
extra capacitors (they are placed on top
of the PSL enclosure above where the capacitors
  
ELOG V3.1.3-