  12678   Thu Dec 15 03:46:19 2016 ranaUpdateIOOIMC WFS whitening filter investigationhttps://dcc.ligo.org/LIGO-D1400414

As it turns out, its not so old
as I thought. Jenne and I reworked these
  
  12688   Thu Dec 29 13:22:21 2016 ranaSummaryIOOIMC WFS tuning
For the rough calibration below
10 Hz, we can use the SUS OSEM cal: the SUSPIT
and SUSYAW error signals are in units of
  
  12690   Thu Dec 29 21:35:30 2016 ranaSummaryIOOIMC WFS tuningThe WFS gains are supposedly
maximized already. If we remotely try
to increase the gain, the two MAX4106 chips
 Screen_Shot_2017-01-03_at_5.55.13_PM.png 
  12691   Thu Dec 29 21:48:32 2016 ranaUpdateIOOMC AutoLocker hung because c1iool0 asleep againMC unlocked, Autolocker waiting for c1iool0
EPICS channels to respond. c1iool0 was responding
to ping, but not to telnet. Keyed the crate
  
  12692   Fri Dec 30 10:27:46 2016 ranaUpdateDetCharsummary pages dead againDead again.
No outputs for the past month. We really
need a cron job to check this out
  
  12693   Thu Jan 5 21:43:16 2017 ranaUpdateDetCharsummary pages dead againMax tells us that soem conf files were
bad and that he did something and now some
pages are being made. But the PEM and MEDM
  
  12694   Fri Jan 6 17:00:26 2017 ranaFrogsTreasureVideo of Lab TourIn this video: https://youtu.be/iphcyNWFD10,
the comments focus on the orange crocs, my
wrinkled shirt, and the first aid kit.
  
  12695   Sun Jan 8 12:47:06 2017 ranaUpdateGeneralOptical Layout in DCCManasa pointed me to the CAD drawings in
the 40m SVN and I've now uploaded them
to the 40m
  
  12700   Tue Jan 10 21:47:00 2017 ranaUpdateCDSpower glitchDoes "done" mean they are OK
or they are somehow damaged? Do
you mean the workstations or the front end
  
  12706   Thu Jan 12 13:43:02 2017 ranaHowTosafetyclosing a doorThis is one of those unsolved door lock
acquisition problems. Its been happening
for years.
  
  12709   Thu Jan 12 23:22:34 2017 ranaUpdateSummary PagesDecember outagePages still not working: PEM and MEDM blank.


Committed existing MEDM
grabbing scripts to SVN. Ran the cron job
  
  12714   Fri Jan 13 21:32:49 2017 ranaHowToDAQGet 40m data using NDS2 and PythonThe attached file is a python notebook
that you can use to get data. Minimal syntax.
 get40mData.ipynb 
  12717   Sat Jan 14 00:53:05 2017 ranaHowToDAQGet 40m data using NDS2 and PythonMinute trend data seems not available using
the NDS2 server. Its super slow using dataviewer
from the control room.
  
  12718   Sat Jan 14 12:12:03 2017 ranaUpdateDAQminute trends missingDid we turn off minute trend writing in
one of the recent FrameBuilder debug sessions?
Seems we only have second trends in 2016.
  
  12720   Sat Jan 14 22:39:30 2017 ranaSummarySUSITMY is drifting ?https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20170114/sus/susdrift/

ITMY is not like the others. Real
or just OSEM madness?
  
  12721   Mon Jan 16 12:49:06 2017 ranaConfigurationComputersMegatron updateThe "apt-get update" was failing
on some machines because it couldn't
find the 'Debian squeeze' repos,
  
  12722   Mon Jan 16 18:54:01 2017 ranaUpdateSUSBS: whitening re-engagedFound that the BS whitening was off. Gautam
says that "it has always been that way"
and "there's nothing in the elog
 BSwhite.pdf 
  12723   Mon Jan 16 21:03:47 2017 ranaSummaryIOOMCL / MCF / CalibrationOot on the streets and in the chat rooms,
people often ask, "What
is up with the MC_F calibration?".
 c1ioo_zoom_MCLF.pngMCL.pdf 
  12726   Tue Jan 17 20:39:30 2017 ranaUpdateComputer Scripts / Programsnodus web apache simlinks too softI tried to follow these instructions today
to make the Simulink Webview accessible:

controls@nodus|public_html
  
  12727   Tue Jan 17 20:47:23 2017 ranaUpdateCDSSimulink Webview updatedSeems like this stops working every ~2
years. Its been busted since early 2016 according
to cron, so I fixed up the paths and restored
  
  12735   Wed Jan 18 15:17:38 2017 ranaUpdateComputer Scripts / Programsnodus web apache simlinks too softI suppose before directory listings were
turned off we should have fixed the script
to make an index.html, but that's how
  
  12741   Thu Jan 19 19:56:09 2017 ranaUpdateSUSMC1 SUS electronics investigationMight be. Or it might be in the satellite
box cabling. Hard to tell without a tester.
I recommend you squish the cables on there
  
  12764   Fri Jan 27 19:40:03 2017 ranaMetaphysicselogword wrapping & large images"Why does the word wrapping not work
in our browsers with ELOG?" I sometimes
wonder. Some of the elogs are fine, but often
  
  12773   Tue Jan 31 13:46:34 2017 ranaUpdateIMCRF AM stabilization box pulled out
What is the probe situation? Ought
to use a high impedance FET probe to measure
this or else the scope would load the circuit.
The
  
  12774   Tue Jan 31 14:14:29 2017 ranaUpdateVACPressure watch scriptI think this cron job is running on NODUS
(our gateway) instead of our scripts machine:


p.p1 {margin:
  
  12777   Tue Jan 31 17:28:36 2017 ranaSummaryCDSMinute Trend KoanSomeone installed "Debian" on
allegra. Why? Dataviewer doesn't work
on there. Is there some advantage to making
  
  12785   Wed Feb 1 20:49:34 2017 ranaUpdateIMCRF AM stabilizer box Modification PlanI suggest:


Disable the path which
goes to the two spare outputs. Replace the
  
  12789   Thu Feb 2 17:34:25 2017 ranaUpdatePEMEM172 mic is hooked up in the PSLI don't know if anyone looked at the
time series (not trend) or spectrum of the
Microphone after installation, but it looks
 MicFail.pdf 
  12791   Thu Feb 2 18:28:29 2017 ranaSummaryCDSMinute Trend Koanand the song remains the same...

the version of SVN on these workstations
is ahead of the one on the other workstations
  
  12792   Thu Feb 2 18:32:51 2017 ranaSummaryPSLPMC alignmentRe-aligned the beam going into the PMC
today around 5 PM. I noticed that its all
in pitch and since I moved both of the mirrors
  
  12795   Fri Feb 3 11:40:09 2017 ranaUpdateIMCMCL Feedback - framing the problemIn working on automatic DARM loop design,
we have this code:

https://git.ligo.org/rana-adhikari/ModernControls/tree/master/OptimalFeedback/GlobalCost
  
  12797   Sat Feb 4 12:00:59 2017 ranaSummaryCDS/cvs/cds/caltech/chans back on svn1.6True - its an issue. Koji and I are updating
zita into Ubuntu16 LTS. If it looks like
its OK with various tools we'll swap
  
  12818   Fri Feb 10 13:04:32 2017 ranaUpdateIOOMC AutoLocker hung because c1iool0 asleep againc1iool0 was down again. Rather than key
the crate, this time I just pushed the reset
button on the front and it came back.
  
  12819   Fri Feb 10 13:24:28 2017 ranaUpdateIMC29.5 MHz stabilizer box replacementTo remind myself about how to put filter
caps on the mini-circuits RF Amps, I looked
at Koji's recent
  
  12823   Mon Feb 13 11:55:14 2017 ranaUpdateIMCIMC length loop - summary of changesI would think that we want to fix
the I/Q orthog inside the demod board by
trimming the splitter. Mixing
  
  12835   Thu Feb 16 21:55:47 2017 ranaSummaryGeneralAlternative Calibration SchemeQuestion for Craig: What does the SNR of
our lines have to be? IF we're only trying
to calibrate the actuator in the audio band
  
  12839   Sat Feb 18 14:09:06 2017 ranaUpdateIMCWFS servos turned back onYikes. Please change the all teh WFS
DQ channels sample rates from 2048 down to
512 Hz. I doubt we ever need anything about
  
  12845   Wed Feb 22 10:16:54 2017 ranaSummaryGeneralAlternative Calibration SchemeOK, but the questions still stands: "   
  12850   Thu Feb 23 18:52:53 2017 ranaUpdateComputersc1psl un-bootableThe fringes seen on the oscope are mostly
likely due to the interference from multiple
light beams. If there are laser beams hitting
  
  12856   Tue Feb 28 18:25:22 2017 ranaUpdatePEMETMX damping recoveredHuh? So should we ask them to put the container
back? Or do you have some other theory about
ETMX tripping that is not garbage related?
  
  12857   Tue Feb 28 21:05:44 2017 ranaSummaryIOOMC Length offset changes MCWFS offsetsThe input offset on the MC length servo
board changes the lock point of the length
loop (by how much? need to calibrate this
  
  12864   Thu Mar 2 17:58:45 2017 ranaUpdateOptical Leversoplev laser RINThis measurement looks bogus - the difference
between dark and not dark is not significant
enough to believe. Need to figure out how
  
  12878   Thu Mar 9 20:38:19 2017 ranaConfigurationIOOMC lock acquisition settings changed; no more HOM locksThe MC was sort of misaligned. It was locking
on some vertical HOMs. So I locked it and
aligned the suspensions to the input beam
  
  12902   Thu Mar 23 08:43:11 2017 ranaUpdateIMCWFS sensing matrix measurementsFor sensing matrix, better to use single
frequency sine response. We don't want
to measure around the bounce or above the
  
  12907   Mon Mar 27 12:48:36 2017 ranaSummaryIOOMCL / MCF / CalibrationWhat readouts do we have for the PMC length?
If we could have a calibrated &
whitened error and control signal
  
  12910   Mon Mar 27 20:29:05 2017 ranaSummaryDetCharSummary pages broken againGoing to the summary pages and looking
at 'Today' seems to break it and
crash the browser. Other tabs are OK, but
  
  12914   Tue Mar 28 21:06:53 2017 ranaSummaryCDS/cvs/cds/caltech/chans back on svn1.6Debian doesn't like EPICS. Or our XY
plots of beam spots...Sad!

 Screenshot-Untitled_Window.png 
  12919   Thu Mar 30 10:41:56 2017 ranaOmnistructureTreasuresus fiber illluminatedVery, very cool!     
  12920   Thu Mar 30 18:11:01 2017 ranaUpdatePSLPMC DAQ assay for feed-forward integrationWhat you have drawn looks good to me: the
cut should be between TP3 and pin3 of the
AD620. This should maintain the DC coupled
  
  12923   Sun Apr 2 23:14:30 2017 ranaUpdateComputer Scripts / Programsnodus update/upgrade/rebootI just did remote apt-get update, apt-get
upgrade, and then reboot on nodus. ELOG started
up by itself.
  
ELOG V3.1.3-