40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 301 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  12193   Thu Jun 16 18:42:12 2016 ranaUpdateCOCContrast as a function of RoC of ETMXThat sounds weird. If the ETMY RoC   
  12197   Mon Jun 20 01:38:04 2016 ranaUpdateCOCContrast as a function of RoC of ETMXSo, it seems that changing the ETMX for
one of the spares will change the contrast
defect from ~0.1% to 0.9%. True? Seems like
  
  12210   Wed Jun 22 08:40:42 2016 ranaUpdateLSCY arm @ 30kHz UGF w/POY, AOBelow 100 Hz, I suppose this means that
the X arm is now limited by the quadrature
sum of the X and Y arm seismic noise.
  
  12214   Sun Jun 26 15:27:28 2016 ranaFrogsIOOPMC /MC lopcedFound PMC unlocked for many hours so I
relocked it. IMC relocked by itself, but
the input switch seems to be flickering to
  
  12245   Tue Jul 5 19:10:41 2016 ranaUpdateGeneralVent progressI'd suggest clamping and moving it
to the flow bench so you can inspect with
a bright light. Then remove the wire and
 jumpEvent20151105.png 
  12286   Sun Jul 10 18:20:39 2016 ranaUpdateElectronicsAntialiasing Filter UpdateComments on the schematic:


Only the instrumentation
amp should be made up of the ADA4004. Not
  
  12330   Mon Jul 25 12:22:18 2016 ranaUpdateComputer Scripts / ProgramsFinished MEDM Tab on Summary PagesLooks pretty great. However, there's
two problems:

1) Some of the MEDM screens don't
  
  12332   Mon Jul 25 13:47:19 2016 ranaUpdateGeneralETMX suspension - progressUgh.    
  12343   Wed Jul 27 16:56:47 2016 ranaMetaphysicsSUSBroken wireFor the rest of this vent, at least, we
need to start using the EQ stops
more frequently. Whenever the
  
  12350   Thu Jul 28 22:43:03 2016 ranaUpdateGeneralETMY UL magnet broke offI'd recommend replacing the wire and
grinding down the clamp to prevent cutting
the wire. Since we have almost never replaced
  
  12358   Sun Jul 31 17:28:38 2016 ranaOmnistructureGeneralupcleanI cleaned up the south Electronics bench
today.

The other two, as well as several
  
  12361   Mon Aug 1 20:09:37 2016 ranaUpdateCDSDAFI UpdateI found the DAFI screen as a button inside
of the LSC screen - I think its more logically
found from the sitemap, so I'll move
  
  12371   Thu Aug 4 10:57:58 2016 ranaUpdateComputer Scripts / ProgramsNODUS update / restarts underwayUsual Ubuntu apt-get upgrades; long delayed
but now happening.
  
  12389   Tue Aug 9 19:35:49 2016 ranaUpdateSEIboth Guralp seismometers are functioning and being acquiredAfter
some cable swapping, we now have both Guralp
seismometers running and the times series
 1goodday.png 
  12406   Fri Aug 12 21:26:28 2016 ranaUpdatePEMMic Self NoiseSeems to good to be true. Maybe you're
over fitting? Please put all the traces on
one plot and let us know how you do the parameter
  
  12419   Wed Aug 17 22:09:04 2016 ranaUpdateSUSSOS sus wire orderedNot really true that it passed. That's
just an arbitrary margin. Best to throw away
all the old wire. We have no quantitative
  
  12460   Thu Sep 1 15:28:01 2016 ranaUpdateElectronicsAcoustic Tab and Amp Suspension
add photo of installation
no
more secret personal pages! put channels
into the actual pages that we look at
make
  
  12462   Thu Sep 1 15:43:16 2016 ranaUpdateSUSOSEM adjustmentsOn the bounce roll balancing:

Recall that back in 2006, the main
issue was not with the bounce mode coupling
  
  12468   Fri Sep 2 21:16:45 2016 ranaUpdateElectronicsSatellite AmplifierIn November of 2010, Valera Frolov (LLO),
investigated
our satellite amplifiers and made some recommendations
  
  12470   Mon Sep 5 21:05:06 2016 ranaUpdateElectronicsSatellite AmplifierThe attached PDF shows the output noise
of the satellite amp. This was calculated
using 'osempd.fil' in the 40m/LISO
 osempd.pdf 
  12472   Tue Sep 6 18:21:13 2016 ranaUpdateSUSOSEM issuesI looked at the PRM free swing spectra.
The modes look like they're at the right
frequencies, so pointing more and more towards
 PRMswing.png 
  12473   Tue Sep 6 20:30:56 2016 ranaUpdateSUSITMY_UL is sickIn the morning, Steve will start opening
the north BS door so that we can enter to
inspect the PRM LR OSEM.
  
  12481   Sat Sep 10 14:26:01 2016 ranaUpdateGeneralPRM SRM alignmentFor the PRM, I aligned it until the arm
flashes were maximized and the REFL camera
showed a centered spot with dips happening
 Osamu.JPG 
  12501   Sat Sep 17 02:00:23 2016 ranaUpdateSUSAlignment statusAll is not lost. I've stuck and unstuck
optics around a half dozen times. Can you
please post the zoomed in time series (not
  
  12503   Sun Sep 18 16:18:05 2016 ranaUpdateSUSAlignment statussusaux is responsible for turning on/off
the inputs to the coil driver, but not the
actual damping loops. So rebooting susaux
  
  12506   Mon Sep 19 13:57:21 2016 ranaUpdateGeneralnever post EPS files in the ELOG. Ever.http://tex.stackexchange.com/questions/2092/which-figure-type-to-use-pdf-or-eps   
  12508   Tue Sep 20 10:45:06 2016 ranaUpdateGeneralFurther recovery progressRana suspicious. We had arms locked before
pumpdown with beams on Transmon PDs. If they're
off now, must be beams are far off on the
  
  12522   Thu Sep 29 09:49:53 2016 ranaUpdateGeneralmucking aboutWith the WFS and OL, we never have figured
out a good way to separate pit and yaw. Need
to figure out a reference for up/down and
  
  12543   Mon Oct 10 17:27:29 2016 ranaUpdateDMFsummar pages dead againBeen non-functional for 3 weeks. Anyone
else notice this? images missing since ~Sep
21.
  
  12562   Fri Oct 14 15:47:00 2016 ranaUpdateTreasurefilters + clipI say just fix the clipping. Don't
worry about the PRM OSEM filters. We can
do that next time when we put in the ITM
  
  12572   Wed Oct 19 17:02:34 2016 ranaUpdateGeneral Viewports & coating of 2016These old specs are not so bad. But we
now want to get replacements for the TRX
and TRY and PSL viewports that are R <0.1%
  
  12588   Fri Oct 28 19:13:57 2016 ranaUpdateGeneralPR gainI don't think the loss of 25 ppm is
outrageous. Its just surprisingly good. The
SIS model predicted numbers more like 1 ppm
  
  12600   Sat Nov 5 15:45:44 2016 ranaUpdateCDSc1auxex channels/pins for AcromagWe don't need to record any of the
AIOut channels, the OL channels (since we
record them fast), or the _MEAN channels
  
  12615   Mon Nov 14 19:32:51 2016 ranaSummaryCDSReplacing DIMM on OptimusI did apt-get update and then apt-get upgrade
on optimus. All systems are nominal.
  
  12622   Thu Nov 17 12:14:21 2016 ranaUpdateCamerasBasler GigE-Camera on Optimus (+Mafalda dead)Indeed. I suggest discussing with Joe B.
I believe we should use a dedicated cam network
to get the camera signals from the ends and
  
  12637   Wed Nov 23 15:08:56 2016 ranaUpdateIMCMCL FeedbackIn the Generic
Pentek interface board, which is used
to take in the analog 2-pin LEMO cable
  
  12647   Tue Nov 29 18:35:32 2016 ranaUpdateIOOIMC WFS Demod board measurement & analysismore U4 gain, lesssss
U5 gain
  
  12675   Thu Dec 8 19:01:21 2016 ranaUpdateIMCPartial IMC ringdownsMach Zucker on howto do Ringdowns:  https://dcc.ligo.org/LIGO-T900007   
  12678   Thu Dec 15 03:46:19 2016 ranaUpdateIOOIMC WFS whitening filter investigationhttps://dcc.ligo.org/LIGO-D1400414

As it turns out, its not so old
as I thought. Jenne and I reworked these
  
  12688   Thu Dec 29 13:22:21 2016 ranaSummaryIOOIMC WFS tuning
For the rough calibration below
10 Hz, we can use the SUS OSEM cal: the SUSPIT
and SUSYAW error signals are in units of
  
  12690   Thu Dec 29 21:35:30 2016 ranaSummaryIOOIMC WFS tuningThe WFS gains are supposedly
maximized already. If we remotely try
to increase the gain, the two MAX4106 chips
 Screen_Shot_2017-01-03_at_5.55.13_PM.png 
  12691   Thu Dec 29 21:48:32 2016 ranaUpdateIOOMC AutoLocker hung because c1iool0 asleep againMC unlocked, Autolocker waiting for c1iool0
EPICS channels to respond. c1iool0 was responding
to ping, but not to telnet. Keyed the crate
  
  12692   Fri Dec 30 10:27:46 2016 ranaUpdateDetCharsummary pages dead againDead again.
No outputs for the past month. We really
need a cron job to check this out
  
  12693   Thu Jan 5 21:43:16 2017 ranaUpdateDetCharsummary pages dead againMax tells us that soem conf files were
bad and that he did something and now some
pages are being made. But the PEM and MEDM
  
  12694   Fri Jan 6 17:00:26 2017 ranaFrogsTreasureVideo of Lab TourIn this video: https://youtu.be/iphcyNWFD10,
the comments focus on the orange crocs, my
wrinkled shirt, and the first aid kit.
  
  12695   Sun Jan 8 12:47:06 2017 ranaUpdateGeneralOptical Layout in DCCManasa pointed me to the CAD drawings in
the 40m SVN and I've now uploaded them
to the 40m
  
  12700   Tue Jan 10 21:47:00 2017 ranaUpdateCDSpower glitchDoes "done" mean they are OK
or they are somehow damaged? Do
you mean the workstations or the front end
  
  12706   Thu Jan 12 13:43:02 2017 ranaHowTosafetyclosing a doorThis is one of those unsolved door lock
acquisition problems. Its been happening
for years.
  
  12709   Thu Jan 12 23:22:34 2017 ranaUpdateSummary PagesDecember outagePages still not working: PEM and MEDM blank.


Committed existing MEDM
grabbing scripts to SVN. Ran the cron job
  
  12714   Fri Jan 13 21:32:49 2017 ranaHowToDAQGet 40m data using NDS2 and PythonThe attached file is a python notebook
that you can use to get data. Minimal syntax.
 get40mData.ipynb 
ELOG V3.1.3-