40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 29 of 341  Not logged in ELOG logo
ID Date Author Type Category Subjectup Text Attachments
  6132   Sun Dec 18 16:16:55 2011 kiwamuUpdateSUSAnother trial of Hysteresis testKoji has modified the script for the hysteresis
measurement.
A
  
  6134   Sun Dec 18 19:56:00 2011 kiwamuUpdateSUSAnother trial of Hysteresis testThe measurement finished at ~ 21:50
PT.

  
  218   Sun Dec 30 02:36:35 2007 pkpUpdateGeneralAnother updateSo I followed suggestions 1 and 3 so far and
have started writing up what all needs to
be done in order to compile and use the camera.
  
  10003   Thu May 29 08:43:34 2014 manasaUpdatePEMAnt season already inAnt season has set in. I spotted and killed
 a few ants around the optics
  
  12203   Mon Jun 20 16:33:09 2016 VarunUpdateElectronicsAnti-Aliasing Filter circuit schematicSummary: The aim is to
design an analog anti-aliasing (AA) filter
placed before the ADC, whose function is
 8x 
  12212   Wed Jun 22 14:03:42 2016 VarunUpdateElectronicsAnti-Aliasing Filter circuit schematicI found an anti-aliasing circuit on the
40m wiki. It consists of A differential LPF
made using THS4131 low noise differential
 io.pdfAA.JPGratios_v2.pdf 
  12164   Thu Jun 9 19:08:58 2016 VarunUpdateElectronicsAnti-Aliasing Filter updateEric gave me a psd plot of a signal which
would be the input of a channel of the AA
filter. the Nyquist freq. is about 32.8kHz.
 32to65.jpg65to98.png 
  10732   Fri Nov 21 18:23:01 2014 diegoUpdateSUSAnti-Jitter Telescope for OpLevsEDIT: some images look
bad on the elog, and the notebook is parsed,
 14x 
  10733   Mon Nov 24 20:24:29 2014 diegoUpdateSUSAnti-Jitter Telescope for OpLevsI stared a bit longer at the plots and
thanks to Eric's feedback I noticed I payed
too much attention to the comparison between
 6x 
  12242   Tue Jul 5 14:12:56 2016 varunUpdateElectronicsAntialiasing Filter UpdateI am trying to design an antialiasing filter,
which also has two switchable whitening stages.
I have designed a first version of a PCB
 AA.pdfAAtop.pdfAAbottom.pdfAAbrd.pdfAA.zip 
  12286   Sun Jul 10 18:20:39 2016 ranaUpdateElectronicsAntialiasing Filter UpdateComments on the schematic:


Only the instrumentation
amp should be made up of the ADA4004. Not
  
  2108   Sun Oct 18 15:46:08 2009 AlbertoConfigurationGeneralAntique, unused QPD removed from the AS table Inspecting the AS table to make an inventory
of the photodiodes in use around the interferometer,
I found a mysterious photodetector hiding
  
  10312   Thu Jul 31 21:59:25 2014 KojiBureaucracyGeneralAntsDon't leave your
food on tables and desks!
Also I put the souvenir chocolates
 P7316690.JPG 
  262   Thu Jan 24 22:52:18 2008 AndreyBureaucracyGeneralAnts around a dirty glass (David - please read!)
Dear coleagues,
  
  2408   Mon Dec 14 00:37:28 2009 KojiOmnistructureEnvironmentAnts in the coffee makerI made a short stop at the 40m on Sunday
night and found that hundreds ants are in
  
  2409   Mon Dec 14 11:21:23 2009 steveOmnistructureEnvironmentAnts in the coffee maker 
 We still had some ants visiting
the sink area this morning. These ants seem
  
  11441   Thu Jul 23 20:57:15 2015 JessicaSummaryGeneralApplying Pre-filter to data before IIR Wiener FilteringI updated my bandpass filter and have  BodePlot.pngacc_bandpass.pngmcl_seis.png 
  520   Thu Jun 5 10:46:26 2008 josephbConfigurationCamerasApproximately uniform reflected white lightIn an attempt to investigate the structures
seen in previous images for the GC750, I
aimed it at a relatively clean section of
 GC650_white_light.pdfGC750_white_light.pdf 
  3619   Wed Sep 29 11:18:36 2010 josephbUpdateCDSApps code changesAfter asking Alex specifically what he
did yesterday after I left, he indicated
he copied  a bunch of stuff from Hanford,
  
  1586   Thu May 14 15:28:28 2009 steveSummarySUSApril 24 earthquake effect on MC2[quote][quote]The MC side problem could also
be the side tramp unit problem. Set the tramp
to 0 and see if that helps.[/quote]
 eq042409.jpg 
  6550   Thu Apr 19 16:21:04 2012 ZachUpdateComputer Scripts / ProgramsArbcav updated, made badassI have modified Arbcav to be way cooler  6x 
  8204   Fri Mar 1 02:49:34 2013 JenneUpdateASSArm A2L measurementI haven't finished debugging the scripts
so that the measurement is fully automatic,
like the MC, but I did measure the arm spot
 QUAD1_1046168242.bmp 
  8229   Tue Mar 5 01:43:04 2013 JenneUpdateASSArm A2L measurement script finishedIn either .../scripts/XARM or ...../scripts/YARM
run either A2L_XARM or A2L_YARM.
The wrapper script will, like the
 YARMdecenter.png 
  8467   Fri Apr 19 16:58:59 2013 JenneUpdateASCArm A2L measurement scripts 90% working againAfter Den's work with the ASS model this
week, all of the channel names were changed
(this wasn't pointed out in his elog....grrr),
  
  10975   Wed Feb 4 19:21:37 2015 KojiUpdateASCArm ASS servos now have triggered gain with arm lock statusWe had persistent frustration by occasional
unlock during ASSing.
Today, I added triggers to the servo
  
  2174   Wed Nov 4 16:49:32 2009 AlbertoUpdateLSCArm Cavity Finesse MeasurementI'm going to work on the X arm to measure
the arm cavity finesse.
The idea is to measure the cavity
 DSC_0952.JPG 
  2175   Wed Nov 4 18:35:19 2009 AlbertoUpdateLSCArm Cavity Finesse Measurement

    
        
  
  2176   Wed Nov 4 21:46:18 2009 AlbertoUpdateLSCArm Cavity Finesse Measurement

    
        
  
  469   Thu May 8 01:50:25 2008 ranaSummaryASCArm Cavity HOM ResonancesNothing new, but I calculated the frequencies
of the first 22 higher order transverse modes
and thought I might as well list them here.
  
  555   Mon Jun 23 21:51:19 2008 AlbertoUpdateGeneralArm Cavity Length MeasurementWe measured the arm cavity lengths sweeping
the ETM mirror position and looking at the
reflected demodulated output. We excited
 40mLengthMeasure.pdf 
  2415   Mon Dec 14 19:33:04 2009 AlbertoUpdateGeneralArm Cavity Poles measured again after cleaning the optics last weekLast week we vented and we cleaned the
main optics of the arm cavities.
I measured the frequency of the cavity
 XarmTF01_fit.pdfYarmTF01_fit.pdfArmCavityFinesseMeasurment.tar.gz 
  2418   Tue Dec 15 05:29:31 2009 AlbertoUpdateGeneralArm Cavity Poles measured again after cleaning the optics last week 
 The Y arm cavity pole moved
down by 130 Hz, whereas the X arm moved by
  
  8741   Tue Jun 25 00:28:52 2013 rana, manasaUpdateLSCArm Cavity scan with X-ALS after ALS servo upgrade[Rana, Manasa]
ALS noise suppressed to 
 6x 
  8742   Tue Jun 25 10:18:34 2013 Mystery ManUpdateLSCArm Cavity scan with X-ALS after ALS servo upgrade

    

       
            
  
  8744   Tue Jun 25 11:39:13 2013 KojiUpdateLSCArm Cavity scan with X-ALS after ALS servo upgradeMy understanding is that that number is
an in-loop evaluation of the loop so far
(as the first step of the loop evaluation).
  
  1577   Tue May 12 15:22:09 2009 YoichiUpdateLSCArm Finesse[quote]
It looks as if the measured DARM response
is skewed by an extra low pass filter at
  
  11430   Mon Jul 20 11:57:17 2015 ericqUpdateGeneralArm Locking recoveredThe interferometer is warming up!

I had some issues locking the IMC
at first. It turned out that the MC3 side
  
  1456   Mon Apr 6 21:50:43 2009 ranaUpdateLSCArm Locking via pushing MC2Inspired by our 'No Refcav' scheme here, I
was inspired to re-explore the idea of locking
the
 mc2-xarm.pdfUntitled.pngnohands.pdf 
  2247   Thu Nov 12 02:02:18 2009 ranaSummaryLSCArm Locking with no feedback to the ETM or ITMSteps:
1) Turn off feedback to ETMY (the
ETMY button on the LSC screen).
 nohands-2.pdf 
  10414   Wed Aug 20 15:31:27 2014 ericqUpdateCOCArm Loss Investigations Continue [ericq, Gabriele] 
Summary: After today's meeting, Gabriele
and I looked into the arm loss situation,
  
  5626   Thu Oct 6 15:40:57 2011 JenneUpdateLSCArm absl length data taken[Katrin, Jenne]
We took the data for the new absolute
length measurement of both arms, after the
  
  5653   Tue Oct 11 21:23:51 2011 JenneUpdateLSCArm absl lengths

    

       
            
  
  728   Wed Jul 23 22:34:07 2008 YoichiUpdateLSCArm cavity g-factor measurementI tried the same thing as the X-arm to the
Y-arm.
I'm puzzled. I found exactly the same behavior
  
  730   Thu Jul 24 01:27:00 2008 KojiUpdateLSCArm cavity g-factor measurement[quote]I locked the Y-arm and mis-aligned
the end mirror in Yaw until the transmission
power gets half.
  
  731   Thu Jul 24 02:57:26 2008 robUpdateLSCArm cavity g-factor measurement[quote]
So, now I feel that the method for the TEM01
quest should be reconsidered.
  
  733   Thu Jul 24 08:09:26 2008 YoichiUpdateLSCArm cavity g-factor measurement[quote]
A-ha! Do you always expect the 30Hz signal,
don't you?
  
  2996   Wed May 26 22:22:03 2010 AlbertoConfiguration40m UpgradingArm cavity lengthThe second sideband is resonant in the
arms for a cavity length of 37.9299m.
The nearest antiresonant arm lengths
 reflRFpowerVsArmLength_3658m.pngreflRFpowerVsArmLength_3750m.png 
  2070   Thu Oct 8 20:18:56 2009 KojiSummaryGeneralArm cavity lossLast night (Oct 07), I ran armLoss script
in order to obtain the latest numbers for
the arm cavity loss.
  
  2416   Mon Dec 14 22:32:56 2009 KojiUpdateGeneralArm cavity loss ~ resultI like to ask someone to review the calculation
on the wiki.
  
  8844   Sun Jul 14 18:19:00 2013 AnnalisaUpdateGreen LockingArm cavity scanYesterday evening Nic and me were in the
lab. The Mode Cleaner was unlocked, but after
many attempt we could fix it and we did many
  
ELOG V3.1.3-