40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 28 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  5919   Wed Nov 16 23:50:40 2011 DenUpdateAdaptive Filteringseismic noise injection[Micro, Den]
Analyzing coherence of seismic noise
and mode cleaner length we've figured out
 datespsd.jpgdatescoh.jpginjectionpsd.jpginjectioncoh.jpg 
  5932   Thu Nov 17 22:24:19 2011 DenUpdateAdaptive FilteringMC1_COILAnalyzing coherence between MC length and
signals on MC1, MC2 and MC3 coils we have
noticed that MC1 COIL signal is not coherent
 MC1COIL-crop.pdfMC2COIL-crop.pdfMC3COIL-crop.pdf 
  5933   Thu Nov 17 23:38:40 2011 DenUpdateIOOMC unlockedMC is unlocked to measure the free swing
of the MC mirrors with the local sensors.
Autolocker is disabled.
  
  5934   Thu Nov 17 23:44:48 2011 DenUpdateIOOMC1_SENSORWe've found that one of the  MC1_SENSORS
does not work properly.
See the figure.
 MCSENSORS.pdf 
  5935   Thu Nov 17 23:47:43 2011 DenUpdateIOOMC1_SENSORThe most interesting plot did not uploaded
in the previous elog.
Upload now local MC1_SENSOR signals.
 MC1SENSOR-crop.pdf 
  5939   Fri Nov 18 01:27:04 2011 DenUpdateIOOMC locked[Mirko, Den]
While the MC was unlocked (and the
local damping off) we've measured the coherence
 cohnolocalpumping-crop_4.pdfcohlocalpumping4-crop.pdfcohlock4-crop.pdf 
  5957   Sat Nov 19 01:26:16 2011 DenUpdateIOOMode cleaner noise projection

    

       
            
  
  6019   Sat Nov 26 19:37:12 2011 DenUpdateGeneralfoton files I've checked foton files for small
numbers. There are several other filters
besides "
  
  6029   Mon Nov 28 18:53:35 2011 DenSummaryWienerFilteringseismic noise substractionThere is still a problem why GUR, STS signals
are poorly coherent to MC_L.  But at
least we can see coherence at 2-5 Hz. It
 9x 
  6038   Tue Nov 29 15:57:43 2011 DenUpdateCDSlocation of currently used filter function 
We are interested in the following
question : Can the structures defined in
  
  6039   Tue Nov 29 17:10:39 2011 DenUpdatedigital noiseSOS creationOne of the possibilities that we see a
large low-frequency digital noise is due
to Foton. I've checked the SOS coefficients
  
  6041   Tue Nov 29 18:31:40 2011 DenUpdatedigital noiseFoton error In the previous elog we've compared
Matlab and Foton SOS representations using
low-order filter. Now we move on to high
  
  6045   Tue Nov 29 22:19:26 2011 DenUpdatedigital noisestraight line I tried to understand what part of
the signal is corrupted while passing through
a digital straight line without any filters.
 real_coherence.jpgfloat_coherence.jpgdouble_coherence.jpg 
  6046   Tue Nov 29 22:54:49 2011 DenUpdatedigital noisesingle precision In the previous elog we've proved
that signals C1:SUS-MC3_LSC_EXCMON and  C1:SUS-MC3_LSC_OUTMON
are in single precision. Now we try to understand
 filter_coherence.jpgchby1_coherence.jpgbutter8_coherence.jpgbutter2_coherence.jpg 
  6052   Wed Nov 30 11:36:12 2011 DenUpdateCDSFiltering Noise issue tracked down ???

    

       
            
  
  6063   Fri Dec 2 20:16:41 2011 DenUpdatedigital noisefirst order transitionIn order to verify our theory about coherence
corruption in linear systems due to the line
 freqz.pdftrans.pdf 
  6064   Sat Dec 3 16:55:52 2011 DenUpdateIOOdigital noise in MCI looked once again to the local OSEM sensors
and MC length signals. Then I replaced 1e-20
to 1e-50 in the if-statement of the iir_filter
 psd_sensors.jpgcoh_sensors.jpgpsd_mcl.jpgcoh_mcl.jpg 
  6065   Sat Dec 3 18:29:20 2011 DenUpdateAdaptive FilteringcoherenceI've looked through the coherence between
the MC length and seismometers after the
if-statement problem was fixed. Coherence
 coh_mcl_seis.pdfsensor_locker.pdf 
  6066   Sun Dec 4 13:56:54 2011 DenUpdateIOOWFSYesterday I locked the MC and left at 8
pm. Analyzing the data I saw that MC was
locked all time from 8 pm to 12.30 am when
  
  6067   Sun Dec 4 23:49:38 2011 DenUpdateIOOWFS

    

       
            
  
  6068   Mon Dec 5 02:55:30 2011 DenUpdateAdaptive FilteringC1OAFI've added filter banks for correction
path in the C1OAF model to use AA filters.
 I compiled and installed the new version.
  
  6075   Tue Dec 6 00:58:34 2011 DenUpdateWienerFilteringOAF current goalAfter reducing the digital noise I did
offline Wiener filtering to see how good
should be online filter. I looked at the
 oaf_goal_psd.pngoaf_goal_coh.png 
  6078   Wed Dec 7 00:11:58 2011 DenUpdateAdaptive FilteringOfflineAF I did offline adaptive filtering
with yesterday's 3 hours of MC-F and GUR1X
data. It turns out that normalized-lms can
 offlineaf_psd.pngofflineaf_coh.png 
  6093   Fri Dec 9 13:28:09 2011 DenUpdateAdaptive FilteringC1OAFI tried to figure out why red NO SYNC label
became present in the C1OAF_GDS_TP screen
after I added AA filters to the C1OAF model.
  
  6095   Fri Dec 9 15:14:41 2011 DenUpdateCDSrelease 2.4Alex has created a 2.4 branch of the RCD.
Jamie, we can try to compile and install
it. As a test a did it for c1oaf, it compiles,
  
  6100   Fri Dec 9 17:53:31 2011 DenUpdateAdaptive FilteringC1OAF[Jenne, Den]
AA filters for witness channels are
added to the oaf model. It is working now
  
  6110   Tue Dec 13 01:20:38 2011 DenUpdateAdaptive FilteringModifications to LSC, RFM models, added OAF model

    

       
            
  
  6137   Mon Dec 19 17:17:02 2011 DenUpdateAdaptive Filteringfilter tap dependenceOnline filter diverges. I did offline simulations
with current c-code. Offline filter also
diverges, even in the simplest case 
 OfflineAF.png 
  6199   Sun Jan 15 10:28:02 2012 DenUpdateAdaptive FilteringdelaysWe can account for delays in the oaf system
by compensating it in the adaptive path of
the filter. But using only this procedure
 2048_tau.png2048_delays.png 
  6200   Sun Jan 15 11:40:30 2012 DenUpdateAdaptive FilteringdownsamplingHere for the downsampling process we use
a low-pass Bessel digital filter of order
6, normalized cut-off frequency = 0.1. In
 2048_downsampling.png2048_512.png 
  6201   Sun Jan 15 12:18:00 2012 DenUpdateAdaptive Filteringrunning time In order to figure out what downsampling
ratio we can take, we need to determine the
running time of the fxlms_filter() function.
  
  6243   Fri Feb 3 10:48:24 2012 DenUpdateComputersc1lsc kernelThis morning I killed again c1lsc kernel
with the new realization of fxlms algorithm.
It works fine with gcc compiler during the
  
  6248   Fri Feb 3 17:17:47 2012 DenUpdateIOOMC SUS misalignment

    
        
  
  6249   Fri Feb 3 17:29:28 2012 DenUpdateComputersc1lsc kernelThe reason I've killed the c1lsc kernel
was the following - when the code starts
to run, it initializes some parameters and
  
  6294   Sat Feb 18 12:23:09 2012 DenUpdateIOOMC When I came to the 40m this afternoon,
the MC was unlocked. Here is the trend of
MC_F for last 2 hours
 mc_trend.png 
  6296   Sat Feb 18 17:01:26 2012 DenUpdateAdaptive Filteringstatic variablesIn order to prevent different DOF from
redetermining static variables in the adaptive
code, I've created a separate code for each
  
  6297   Sat Feb 18 18:29:38 2012 DenUpdateAdaptive Filteringonline filteringI tried to filter MC_F from seismic noise
measured by GUR1 seismometer. I've used 8000
tap filter, downsample ratio=8, delay=1.
 output.pdf 
  6328   Mon Feb 27 21:26:22 2012 DenUpdatePEMseis boxI did liso simulation of the circuit in
the seis box. I think that AD620 (first amplifier
in the circuit) noise might be much less
 ad620.pdfnoise.pdfwhole.pdf 
  6332   Tue Feb 28 16:12:59 2012 DenUpdateAdaptive Filteringlunch talk Just to be clear what I said at the
meeting, I write all this down here. Adaptive
filtering of real signals (MC_F and GUR1_X)
 gains.pngwiener.png 
  6338   Wed Feb 29 01:02:06 2012 DenUpdatePEMseis box measuredI've measured the input signal to the seismic
box from seismometer Guralp 1. The spectrum
of the signal in the "input +"
 input.pngoutput.pngtf.pngcoherence.png 
  6343   Thu Mar 1 00:05:23 2012 DenUpdatePEMseis box noiseI've moved GUR1 seismometer from MC2 to
the working tables in order not to disturb
the MC while working with the seismometer
 DSC_3959.JPGnoise.png 
  6345   Thu Mar 1 21:48:34 2012 DenUpdatePEMseis box noise


   
        
            
 noise2.pngnoise.png 
  6346   Fri Mar 2 11:05:28 2012 DenUpdatePEMseis box gainI've replaced R2 resistor that adjusts
the gain of the AD620 amplifier. Previous
value 5491Ohm, new value 464Ohm, so the gain
 tf_new.pdfnoise_new.pdftf_analyzer.pngnoise_analyzer.png 
  6347   Fri Mar 2 16:05:52 2012 DenUpdateSAFETYlaser safetyToday I've attended the laser safety seminar.   
  6349   Fri Mar 2 18:55:06 2012 DenUpdatePEMseis boxI've put the seismometer box back to the
1x1, Guralp is back under MC2. When the seismometer
is not plugged in, the noise is
 dv_noise.png 
  6356   Mon Mar 5 15:15:15 2012 DenUpdatePEMRCG[Alex / Den]
I've encountered a problem that C1:PEM-SEIS_GUR1_X_IN1
is saved in the int format. It turned out
  
  6427   Sun Mar 18 00:29:24 2012 DenUpdatePEMsts-2I've turned off the power of the STS-2
readout box as it provides outputs with ~10
Volts DC offset! AA filter box works in the
  
  6490   Thu Apr 5 18:24:55 2012 DenConfigurationAdaptive Filteringoaf starts to workToday I tried to make the lms filter to
work online. I played around with the signals
(GUR1_X and MC_F) to pre-whiten them and
 oaf2.pdf 
  6491   Fri Apr 6 09:57:24 2012 DenUpdateAdaptive Filteringstatic starts to workI made static filter to work to evaluate
the actuator TF.. Here is the result of static
filtering:
 7x 
  6492   Fri Apr 6 10:31:07 2012 DenUpdateAdaptive Filteringstatic and adaptiveI've run static and adaptive filters simultaneously.
AA32 filters rotate the phase of the witness
signals GUR1X and GUR1Y and now the performance
 static_oaf.pdf 
ELOG V3.1.3-