5816
|
Fri Nov 4 21:52:58 2011 |
Den | Update | Adaptive Filtering | coherence |
[Mirko, Den]
We still think about the coherence between seismic noise and mode cleaner length. We beleive that
1. Below ~0.1 Hz tilt affects on the seismometers as was simulated http://nodus.ligo.caltech.edu:8080/40m/5777
2. From 0.1 to 1 Hz is an interesting region. We try to figure out why we do not see any coherence here. Tilt does not seem to dominate.
At 1 Hz coherence might be lost because of the sharp resonance. For example, if the mirror is suspended to the platform by wires with f = 1 Hz and Q = 1000, then the coherence between platform motion and mirror motion will be lost as shown on the figure below.

For this reason we tried to "help" to the adaptive filter to guess transfer function between the ground motion and mirror motion by multiplying seimometer signal by the platform -> mirror transfer function. As we do not know exactly eigen frequency and Q of the wires, we did a parametric simulation as shown on the figure below

The maximum coherence that we could achieve with treak was 0.074 compared to 0.056 without. This was achieved at f=1.0011 Hz but with surprisingly high Q = 330. And though this did not help, we should keep in mind the tecnique of "helping" the adaptive filter to guess the transfer function if we partly know it.
Another unexpected thing is that we see come coherence between gur1_x and mode cleaner WFS pitch signal at frequencies 0.1 - 1 Hz

From this we can suggest that either mode MC_F channel does not completely reflect the mc length at low frequencies or WFS2 shows weard signal. |
5825
|
Sun Nov 6 21:09:03 2011 |
rana | Update | Adaptive Filtering | coherence |
Quote: |
[Mirko, Den]
We still think about the coherence between seismic noise and mode cleaner length. We beleive that
|
The 'helping' trick is a good one: we should use our best guess for the stackTF and the pendulumTF and put it into the IIR filter bank to pre-filter the seismometer signals before they get to the MC mirrors. Also should remember that the signal we send to suppress the seismic motion is applied to the pendulum as a force, not a displacement.
The 3 Hz fast cutoff in the MC_F signal is a good clue. It means that at low frequencies, perhaps the noise source is going through a digital 3 Hz elliptic or Chebychev filter. |
6065
|
Sat Dec 3 18:29:20 2011 |
Den | Update | Adaptive Filtering | coherence |
I've looked through the coherence between the MC length and seismometers after the if-statement problem was fixed. Coherence improved for all seismometers but is still not 1. It is possible that contribution from X, Y, Z directions split the coherence between them but at ~0.2-03 Hz we do not see much coherence for all these directions.

I looked at the coherence between MC2 OSEM signal and MC_F when the AUTO LOCKER is ON and OFF. I thought that we'll ses the same coherence for both regimes as laser is locker to the MC length. However, I figured out the coherence is worse when AUTO LOCKER is ON at frequencies 0.2-0.3 Hz.

The first idea that comes to mind is that when feedback to the laser is provided, the pressure to the mirrors from the laser beam is changed. |
2206
|
Mon Nov 9 01:52:56 2009 |
rana | Update | PEM | coherence v. time for 2 accelerometers |
I used the coh_carpet.m function from the mDV to calculate this plot:
coh_carpet('C1:PEM-ACC_MC1_X','C1:PEM-ACC_MC2_X',gps('now - 3 days'),3600*12,4,10,64)
It shows the coherence v. time of two of our X-direction accelerometers starting around 1AM on Friday and going for 12 hours.
I'm not sure what it means exactly, but it looks like the coherence is relatively steady as a function of time. I will need more RAM than Rosalba or a smarter code to calculate longer time stretches. |
Attachment 1: coh.png
|
|
13417
|
Wed Nov 8 12:19:55 2017 |
gautam | Update | SUS | coil driver series resistance |
We've been talking about increasing the series resistance for the coil driver path for the test masses. One consequence of this will be that we have reduced actuation range.
This may not be a big deal since for almost all of the LSC loops, we currently operate with a limiter on the output of the control filter bank. The value of the limit varies, but to get an idea of what sort of "threshold" velocities we are looking at, I calculated this for our Finesse 400 arm cavities. The calculation is rather simplistic (see Attachment #1), but I think we can still draw some useful conclusions from it:
- In Attachment #1, I've indicated with dashed vertical lines some series resistances that are either currently in use, or are values we are considering.
- The table below tabulates the fraction of passages through a resonance we will be able to catch, assuming velocities sampled from a Gaussian with width ~3um/s, which a recent ALS study suggests describes our SOS optic velocity distribution pretty well (with lcoal damping on).
- I've assumed that the maximum DAC output voltage available for length control is 8V.
- Presumably, this Gaussian velocity distribution will be modified because of the LSC actuation exerting impulses on the optic on failed attempts to catch lock. I don't have a good model right now for how this modification will look like, but I have some ideas.
- It would be interesting to compare the computed success rates below with what is actually observed.
- The implications of different series resistances on DAC noise are computed here (although the non-linear nature of the DAC noise has not been taken into account).
Series resistance [ohms] |
Predicted Success Rate [%] |
Optics with this resistance |
100 |
>90 |
BS, PRM, SRM |
400 |
62 |
ITMX, ITMY, ETMX, ETMY |
1000 |
45 |
- |
2000 |
30 |
- |
So, from this rough calculation, it seems like we would lose ~25% efficiency in locking the arm cavity if we up the series resistance from 400ohm to 1kohm. Doesn't seem like a big deal, becuase currently, the single arm locking |
Attachment 1: vthresh.pdf
|
|
10563
|
Fri Oct 3 10:10:37 2014 |
Steve | Update | VAC | cold cathode gauge reading switched |
We have two cold cathode gauges at the pump spool and one signal cable to controller. CC1 in horizontal position and CC1 in vertical position.
CC1 h started not reading so I moved cable over to CC1 v |
Attachment 1: CC1switched.png
|
|
7044
|
Fri Jul 27 14:28:36 2012 |
steve | Update | VAC | cold cathode gauges |
Our cold cathode 423 gauges are 10 years old. They get insulated by age and show no ionization current. We should replace them at the next vent. I'm buying 4 at $317ea
|
Attachment 1: cc_gauges.png
|
|
11625
|
Mon Sep 21 11:12:14 2015 |
Steve | Update | VAC | cold cathode is flaky |
CC4 cold cathode gauge jump triggered interlock to close VM1 valve to protect the RGA.
The IFO pressure is 1e-5 Torr
Vac normal was recovered by opening VM1
|
Attachment 1: cc4jumps.png
|
|
11633
|
Tue Sep 22 08:58:38 2015 |
Steve | Update | VAC | cold cathode is flaky |
The cold cathode gauge is back to normal. cc4 is the last gauge is "functioning"
MKS is not responding. The spare controller and gauges are back for repair.
|
Attachment 1: 4and80days.png
|
|
11644
|
Fri Sep 25 17:00:38 2015 |
Steve | Update | VAC | cold cathode is flaky |
The IFO pressure is estimated ~1E-6 Torr with modified Vac normal valve configuration.
CC4 is in a jumping mode between 2e-5 and 1e-6 Torr
Pressure based interlock kicks in to close VM1 at 2e-5 Torr to protect the RGA.
I did open VM1 repeatedly in the last few mornings but as cc4 jumps VM1 closes.
As VM1 closed to RGA scans are not seeing the IFO. I will look at some scans on Monday.
Mean while I opened VM2 to lower the pressure for the RGA. This change will be read by "Current Status: Undefined State"
So do not panic, the IFO pressure is normal.
I need someone's help to raise the interlock threshold to 5e-5 Torr
I'm buying a new cold cathode gauge on Monday.
note: cc1 is out of order!
just read P1 the pressure is < 7e-4 Torr This gauge is very reliable and it is at the low end of it's range.
|
Attachment 1: flakyCC4.png
|
|
4424
|
Tue Mar 22 16:39:51 2011 |
kiwamu | Update | Green Locking | comaprator installed : 80 pm residual displacement |
A comparator has been installed before the MFDs (mixer-based frequency discriminator) to eliminate the effect from the amplitude fluctuation (i.e. intensity noise).
As a result we reached an rms displacement of 580 Hz or 80 pm.
(differential noise measurement)

Here is the resultant plot of the usual differential noise measurement.
The measurement has been done when the both green and red lasers were locked to the X arm.
In the blue curve I used only MFD. In the black curve I used the combination of the comparator and the MFD.
Noise below 3 Hz become lower by a factor of about 4, resulting in a better rms integrated from 40 Hz.
Note that the blue and the black curve were taken while I kept the same lock.
A calibration was done by injecting a peak at 311 Hz with an amplitude of 200 cnt on the ETMX_SUS_POS path.
(installation)
Yesterday Koji modified his comparator circuit such that we can take a signal after it goes thorough the comparator.
The function of this comparator is to convert a sinusoidal signal to a square wave signal so that the amplitude fluctuation doesn't affect the frequency detection in the MFD.
I installed it and put the beat-note signal to it. Then the output signal from the comparator box is connected to the MFDs.
The input power for the comparator circuit has been reduced to -5 dBm so that it doesn't exceeds the maximum power rate. |
13954
|
Wed Jun 13 11:59:03 2018 |
keerthana | Update | elog | command line enabled code for frequency scanning |
I have modified the code for frequency scanning and have made it completely command line enabled. The code is written in python. It is saved in the name "frequency_scanning_argparse.py". I have uploaded it to the Mode-Spectroscopy Github repository.
Inorder to use this code there are two ways.
1. We can mention the ' frequency' on which marconi need to work. Then it will change the marconi frequency to that perticular value.
eg: Type in the terminal as follows for changing the marconi frequency to 59 Mhz.
python frequency_scanning_argparse.py 59e6
2. Inorder to give a scan to the marconi frequency, provide the 'start frequency', 'end frequency' and the 'number of points' in between. This will be more conveniant when we want to run the scan in different ranges.
eg: Type in the terminal as follows for a start frequency of 59 Mhz, end frequency of 62MHz and number of points in between equal to 1000.
python frequency_scanning_argparse.py 59e6 62e6 1000
In both cases the code will show you the frequency of the marconi before we run this code and it will change the marconi frequency to the desired frequency. |
9468
|
Fri Dec 13 18:03:00 2013 |
Den | Update | IOO | common mode servo |
Quote: |
Well, let's see how the CM servo can handle this.
The key point here is that we have enough data to start the design of the CM servo.
|
It seems to me that current design of the common mode servo is already fine. Attached plots show common mode open and closed loop transfer function.
Frequency response of the servo is taken from the document D040180. I assumed coupled cavity pole to be ~100 Hz.
The only question is if our EOM has enough range. Boost 2 increases noise injection by 10 dB in the frequency range 20-50 kHz. Boost 3 has even higher factor. |
Attachment 1: CM_OL.pdf
|
|
Attachment 2: CM_CL.pdf
|
|
9470
|
Fri Dec 13 23:07:04 2013 |
Koji | Update | IOO | common mode servo |
Looks good.
Once the control cable (bakplane cable) is identified, we can install the module to the LSC analog rack.
We should be able to test the CM servo with either POX or POY and only one correspoding arm without modifying the servo TF.
Just for this test, we don't need to use MCL. |
9472
|
Sat Dec 14 11:56:54 2013 |
rana | Update | LSC | common mode servo |
Quote: |
It seems to me that current design of the common mode servo is already fine. Attached plots show common mode open and closed loop transfer function.
|
These seem like pretty terrible loop shapes. Can you give us a plot with the breakdown of several of the TFs and some .m file?
We should be able to estimate the noise coming out of the MC using the single arm and then make a guess for the CM loop gain requirement. There's no reason to keep the old Boost shapes; those were used in the old MC configuration which had a RefCav. In addition to minimizing the EOM range, we should also minimize the AO signal as Koji has pointed out. In practice, I've seen that using ~300 Hz of offset makes no harm with 4 kHz MC pole. |
9474
|
Sat Dec 14 14:21:46 2013 |
Den | Update | LSC | common mode servo |
Quote: |
These seem like pretty terrible loop shapes. Can you give us a plot with the breakdown of several of the TFs and some .m file?
|
Attached is matlab code that I used
% IMC OL
G = zpk(-2*pi*8964, 2*pi*[-10; -10; -10; -1000; -274000], db2mag(242.5)) * ...
tf([1 0.8*1.55e+05 3.1806e+10], 1);
% CARM PATH
CARM = G/(1+G);
% Common mode boosts
BOOST = zpk(-2*pi*4000, -2*pi*40, 1);
BOOST1 = zpk(-2*pi*20000, -2*pi*1000, 1);
BOOST2 = zpk(-2*pi*20000, -2*pi*1000, 1);
BOOST3 = zpk(-2*pi*4500, -2*pi*300, 1);
% Coupled cavity pole
CCPole = zpk([], -2*pi*100, 2*pi*100);
% Servo gain
Gain = db2mag(43);
% CARM OL with boosts
H = CARM * CCPole * BOOST * Gain;
H1 = H * BOOST1;
H2 = H1 * BOOST2;
H3 = H2 * BOOST3;
% Plot
% bode(H, H1, H2, H3, 2*pi*logspace(3, 5, 10000));
% bode(1/(1+H), 1/(1+H1), 1/(1+H2), 1/(1+H3), 2*pi*logspace(3, 5, 10000)); |
4161
|
Sun Jan 16 02:20:59 2011 |
Suresh | Update | Locking | comparing the PSL with the X-end-NPRO through the green beat |
Objective:
We wish to study the coherence of the two NPROs i.e. PSL and the X-end-NPRO by locking both of them to the X-arm and then observing the green beat frequency fluctuations.
What we did:
a) locked the PSL to the X-arm as described in 4153
b) locked the x-end-NPRO to the X-arm with a PDH lock to the reflected green from the ETMX
c) Obtained the green beat signal with a spectrum analyser as described in 3771
Observations:
Please see the attached screen shots from the spectrum analyser. They are taken with different BW and sweep range settings. They give a estimate of the width of the green beat signal and the range of the frequency fluctuations of the beat-note.
  

Estimates:
a) width of the beat note is less than 6KHz if measured over time scales of a few milli seconds
b) the frequency fluctuations of the beat note are about 100KHz over time scales longer than 100ms
Next Step:
We wish to record the beat note frequency as a function of time in order to establish the stability over time scale of a day.
|
4166
|
Wed Jan 19 03:37:30 2011 |
Suresh | Update | Locking | comparing the PSL with the X-end-NPRO through the green beat |
[Kiwamu, Suresh]
Today we attempted to convert the beat-note frequency into an analog voltage using the SR620 frequency counter.
First an observation: the stability of the green beat was seen to be much better than the 100kHz fluctuation seen yesterday. Probably because Kiwamu noticed that one of the MC mirrors had a large variance in its motion and changed the gain and filter parameters to decrease this. The PSL was therefore more stable and the green peak fluctuation was less than 10kHz over time scales of a few seconds.
SR620 D/A output resolution given by the manufacturer is 5mV over the -10 to +10V range and this range corresponding to 300MHz. We, however saw fluctuations of 100mV on the screen which looked as if they corresponded to the least significant bit. This would imply a resolution of 1.5MHz at this range. Even if the manufacturer's claim was true it would lead to a resolution of 75kHz, far in excess of the required resolution a few hundred Hz.
We therefore require to set up the VCO-PLL to obtain a finer frequency resolution.
In the mean time the green beat drifted beyond the 100MHz detection band of the green-PD. So we changed the x-end-NPRO temperature by -0.05 to bring it back into the detection band.
We are also considering, Rana and Koji's suggestion of using a set of 14 flip-flops to divide the ~80MHz beat frequency so that it comes down to about 4kHz. This could then be sampled by the usual 16-bit, 64kSa/s ADC cards and brought into the digital domain where further digital processing would be needed to extract the the required frequency variations in the 0 to 10kHz band. Found a nice paper on this object |
Attachment 1: Phase_noise_in_digital_frequency_dividers.pdf
|
|
181
|
Fri Dec 7 18:28:30 2007 |
tobin | Update | Computer Scripts / Programs | compiled matlab hoses itself |
Andrey pointed out to me that some matlab functions in the Signal Processing Toolbox were dying with errors. Looking into the .m file (identified using the "which" command), I was surprised to see binary garbage rather than glistening, clear Matlab prose. Then I noticed the directory in which it was finding the .m file:
>> which decimate
/cvs/cds/caltech/apps/mDV/extra/linetrack_c_mcr/toolbox/signal/signal/decimate.m See that "linetrack_c_mcr" directory? This is what is generated when a "compiled" (grumble) Matlab program is run--it decompresses itself into a subdirectory containing weird semi-compiled binary .m files. Unfortunately this is somehow getting incorporated into the matlab path. (I assume there is something in mDV that says "put all subdirectories into the path.")
I hate the Matlab compiler. |
182
|
Fri Dec 7 18:31:30 2007 |
tobin | Update | Computer Scripts / Programs | compiled matlab hoses itself |
Addendnum. The reason the linemon_mcr command was in the path was because of the user issuing the command "addpath(genpath(pwd))" where genpath(D) "returns a path string starting in D, plus, recursively, all the subdirectories of D."
The Matlab compiler is still bad, however. |
9432
|
Mon Dec 2 14:24:10 2013 |
Steve | Update | CDS | computer problems |
Rack 1x6 is very noisy.
SunFire X4600 computer: FB (directly below Megatron) has it's yellow warning light on. It must be loosing one of it's fan bearings.
Jetstore's error message: IDE channel #2 reading error |
Attachment 1: c1iscex.png
|
|
Attachment 2: 1X6.JPG
|
|
9436
|
Tue Dec 3 17:08:06 2013 |
Koji | Update | CDS | computer problems |
It seems that the front fan unit was running at the full speed. The fan itself seems still OK.
I talked with Jamie and make a power cycling (i.e. shutdown gracefully, unplug the power supply cables (x4), plug them in again, and pushed the power button)
The warning signal went off and the fan is quiet. FOR NOW.
Now, daqd and ndsd is down.
FB cannot mount /opt/rtcds and /cvs/cds during its boot.
After mounting these manually, I tried to run /opt/rtcds/caltech/c1/target/fb/start_daqd.inittab and /opt/rtcds/caltech/c1/target/fb/start_nds.inittab
but they don't keep running.
I'll be back to this issue tomorrow with Jamie's help. |
1771
|
Tue Jul 21 18:46:47 2009 |
steve | Configuration | Computers | computers are down |
All suspentions are kicked up. Sus dampings and oplev servos turned off.
c1iscey and c1lsc are down. c1asc and c1iovme are up-down |
1772
|
Wed Jul 22 01:57:19 2009 |
Alberto | Configuration | Computers | computers are down |
Quote: |
All suspentions are kicked up. Sus dampings and oplev servos turned off.
c1iscey and c1lsc are down. c1asc and c1iovme are up-down
|
The computers and RFM network are up working again. A boot fest was necessary.Then I restored all the parameters with burtgooey.
The mode cleaner alignment is in a bad state. The autolocker can't get it locked. I don't know what caused it to move so far from the good state that it was till this afternoon. I went tuning the periscope but the cavity alignment is so bad that it's taking more time than expected. I'll continue working on that tomorrow morning. |
1773
|
Wed Jul 22 09:04:10 2009 |
Alberto | Configuration | Computers | computers are down |
Quote: |
Quote: |
All suspentions are kicked up. Sus dampings and oplev servos turned off.
c1iscey and c1lsc are down. c1asc and c1iovme are up-down
|
The computers and RFM network are up working again. A boot fest was necessary.Then I restored all the parameters with burtgooey.
The mode cleaner alignment is in a bad state. The autolocker can't get it locked. I don't know what caused it to move so far from the good state that it was till this afternoon. I went tuning the periscope but the cavity alignment is so bad that it's taking more time than expected. I'll continue working on that tomorrow morning.
|
I now suspect that after the reboot the MC mirrors didn't really go back to their original place even if the MC sliders were on the same positions as before. |
1776
|
Wed Jul 22 11:14:11 2009 |
Alberto | Configuration | Computers | computers are down |
Quote: |
Quote: |
Quote: |
All suspentions are kicked up. Sus dampings and oplev servos turned off.
c1iscey and c1lsc are down. c1asc and c1iovme are up-down
|
The computers and RFM network are up working again. A boot fest was necessary.Then I restored all the parameters with burtgooey.
The mode cleaner alignment is in a bad state. The autolocker can't get it locked. I don't know what caused it to move so far from the good state that it was till this afternoon. I went tuning the periscope but the cavity alignment is so bad that it's taking more time than expected. I'll continue working on that tomorrow morning.
|
I now suspect that after the reboot the MC mirrors didn't really go back to their original place even if the MC sliders were on the same positions as before.
|
Alberto, Rob,
we diagnosed the problem. It was related with sticky sliders. After a reboot of C1:IOO the actual output of the DAC does not correspond anymore to the values read on the sliders. In order to update the actual output it is necessary to do a change of the values of the sliders, i.e. jiggling a bit with them. |
3493
|
Tue Aug 31 10:44:17 2010 |
steve | Update | PEM | concrete sealed |
The PSL -leg concrete was sealed with a single coat of SCOFIELD Cureseal-S to minimize shedding of particles.
The optical table was covered and optics were removed from the shelf. Accelerometers were turned off. |
Attachment 1: P1060787.JPG
|
|
12825
|
Mon Feb 13 17:19:41 2017 |
yinzi | Configuration | | configuring ethernet for raspberry pi |
Gautam and I were able to get the Raspberry Pi up and running today, including being able to ssh into it from the control room.
Below are some details about the setup/procedure that might be helpful to anyone trying to establish Ethernet connection for a new RPi, or a new operating system/SD card.
Here is the physical setup:


The changes that need to be made for a new Raspbian OS in order to communicate with it over ssh are as follows, with links to tutorials on how to do them:
1. Edit dhcpcd.conf file: https://www.modmypi.com/blog/how-to-give-your-raspberry-pi-a-static-ip-address-update
2. Edit interfaces file: https://www.mathworks.com/help/supportpkg/raspberrypi/ug/getting-the-raspberry_pi-ip-address.html
3. Enable ssh server: http://www.instructables.com/id/Use-ssh-to-talk-with-your-Raspberry-Pi/
The specific addresses for the RPi we set up today are:
IP Address: 192.168.113.107
Gateway/Routers/Domain Name Servers: 192.168.113.2
Netmask: 255.255.255.0
GV: I looked through /etc/var/bind/martian.hosts on chiara and decided to recycle the IP address for Domenica.martian as no RPis are plugged in right now... I'm also removing some of the attachments that seem to have been uploaded multiple times. |
3862
|
Thu Nov 4 17:24:49 2010 |
steve | Update | General | conflat flanges for MIT |
8 pieces of 10" CF blanks were shipped to MIT |
Attachment 1: P1070020.JPG
|
|
9802
|
Fri Apr 11 14:57:53 2014 |
steve | Update | LSC | congratulation |
|
Attachment 1: whenSheisHappy3h.png
|
|
Attachment 2: mc4hArms3hrs.png
|
|
9803
|
Fri Apr 11 16:04:31 2014 |
Koji | Update | LSC | congratulation |
It's just one of the stepping stones, but not yet a mile stone.
Keep going forward! |
990
|
Thu Sep 25 03:12:13 2008 |
rana | Summary | Computers | conlog and linux1 |
It would be nice to have conlog from outside. Right now its on linux1 and so its unavailable. To
test it for speed we ran the command line conlog on linux1, linux2, and nodus.
It was slightly faster on nodus than linux1, implying that its not a network speed issue. It was
phenomenally slower on linux2.
I used the command '/sbin/lspci -vvv' to check what network cards are installed where. As it turns
out, linux2 has a GigE card, but linux1, our NFS server, has only a 100 Mbit card:
01:08.0 Ethernet controller: Intel Corporation 82562EZ 10/100 Ethernet Controller (rev 01)
Subsystem: Intel Corporation Unknown device 304a
Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV+ VGASnoop- ParErr- Stepping- SERR+ FastB2B-
Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR-
Latency: 32 (2000ns min, 14000ns max), Cache Line Size: 64 bytes
Interrupt: pin A routed to IRQ 209
Region 0: Memory at ff8ff000 (32-bit, non-prefetchable) [size=4K]
Region 1: I/O ports at bc00 [size=64]
Capabilities: [dc] Power Management version 2
Flags: PMEClk- DSI+ D1+ D2+ AuxCurrent=0mA PME(D0+,D1+,D2+,D3hot+,D3cold+)
Status: D0 PME-Enable- DSel=0 DScale=2 PME-
We (Joe) need to buy a GigE card for linux1 and to also set up conlog and conlogger to run on Nodus. |
5379
|
Sat Sep 10 18:52:45 2011 |
rana | Update | Computers | conlog getting filled up |
One of the reasons that conlog seems so slow lately is that its been writing 100's of MB of .log files every day since early summer. It looks like the people who have been working on the mdl builds have not been properly adjusting the conlog channel lists. When this is not done conlog just gets filled up with non-control channels like OUT, OUTPUT, OUTMON, etc.
Peter Shawhan has supplied us with many scripts in the conlog directory to clean up these bloated files and fix the channel list. |
8725
|
Wed Jun 19 16:04:56 2013 |
Jamie | Configuration | Computer Scripts / Programs | conlog startup fixed, and restarted |
I cleaned up a bunch of conlog stuff to make it all a little more sane and simple. I also fixed the messy startup shenanigans, so that it should now start up sanely and on it's own (using Ubuntu's native upstart system). The conlog wiki page was updated with all the new info. |
8726
|
Wed Jun 19 16:47:34 2013 |
Jamie | Configuration | Computer Scripts / Programs | conlog startup fixed, and restarted |
Quote: |
I cleaned up a bunch of conlog stuff to make it all a little more sane and simple. I also fixed the messy startup shenanigans, so that it should now start up sanely and on it's own (using Ubuntu's native upstart system). The conlog wiki page was updated with all the new info.
|
By the way, I also did confirm that it is running and registering EPICS changes. |
615
|
Tue Jul 1 14:24:58 2008 |
rob | HowTo | Computer Scripts / Programs | conlog time machine |
I've written a perl script (now in the $SCRIPTS/general directory) which implements a "conlog restore" command, restoring channels matching a regexp to a given time using the conlog records and the EpicsTools.pm perl module. The script is called time_machine_conlog:
Quote: |
op440m:~>time_machine_conlog
time_machine_conlog restores EPICS control settings using a conlog time
usage: time_machine_conlog [<--dryrun>] <date=yyyy/mm/dd,hh:mm:ss> <timezone> <regexp>
Can also accept a gps time, in which case timezone=gps.
Use the option <--dryrun> to see conlog output without restoring any settings.
EXAMPLE: time_machine_conlog 2008/05/30,12:00:00 PDT "C1:SUS-MC.*_(PIT|YAW)_COMM"
|
It sometimes returns an error message even when the command is successful--this is because conlog stores EPICS settings to an absurd level of precision, but ezcawrite will not write EPICS values to this level (or at least won't indicate if it did). I consider this a bug in ezcawrite so I'm not touching it.
The script is untested with regards to switch settings (such as ENABLE/DISABLE). It's mainly intended for numerical values. |
32
|
Tue Oct 30 19:32:13 2007 |
tobin | Problem Fixed | Computers | conlogger restarted |
I noticed that the conlogger wasn't running. It looks like it hasn't been running since October 11th. I modified the restart_conlogger script to insist that it run on op340m instead of op440m, and then ran it on op340m. |
1224
|
Tue Jan 13 11:10:42 2009 |
rob | Configuration | Computers | conlogger restarted |
unknown how long it's been down. |
1919
|
Mon Aug 17 09:52:04 2009 |
rob | Summary | General | conlogger restarted |
I restarted the conlogger on op340m. This needs to be done when op340m is rebooted--it wasn't done for some reason and so we've lost several days of controls records. |
1920
|
Mon Aug 17 17:43:11 2009 |
rana | Summary | General | conlogger restarted |
Added the conlog directory to the SVN, minus the enormous data directory. We are now free to make changes to the conlog code. |
1921
|
Mon Aug 17 17:48:49 2009 |
rob | Summary | General | conlogger restarted |
Quote: |
I restarted the conlogger on op340m. This needs to be done when op340m is rebooted--it wasn't done for some reason and so we've lost several days of controls records.
|
I added a cronjob on op340m to check every half-hour if the conlog is running, and if not, restart it. |
6673
|
Thu May 24 12:23:00 2012 |
Den | Update | General | connection error monitor for the website |
The main page of connection error monitor can be a scheme of computers and models with connections. If there is an error in connection, the corresponding arrows turns from green to red.

Each arrow is a line to a more detailed information about the channels.

|
100
|
Wed Nov 14 12:33:35 2007 |
tobin | AoG | Environment | construction |
The construction crews are running a jack-hammer right outside of the control room. |
Attachment 1: DSC_0172.JPG
|
|
11188
|
Wed Apr 1 10:50:59 2015 |
Steve | Update | PEM | construction ahead |
The 40m fenced area will start storing this large ~ 8000 lbs chamber on April 14. The asphalt will be cut, jack hammered the next 2-3 days in order to lay concrete.
Their schedule is from 8 to 5 starting tomorrow. We are asking them to work from 6 to 3pm
ETMX is about 12-15 ft away |
Attachment 1: largeMITchamber.jpg
|
|
2298
|
Thu Nov 19 09:48:54 2009 |
steve | Update | PEM | construction effect |
8 days plot: Thurdsay, Friday, Sat and Sun without construction |
Attachment 1: varseism.png
|
|
2248
|
Thu Nov 12 09:43:29 2009 |
steve | Update | PEM | construction has started at CES |
The concrete floor cutting has begun next door at CES |
Attachment 1: cuttingconcr.jpg
|
|
Attachment 2: cutcon1.JPG
|
|
Attachment 3: cutcon2.JPG
|
|
2272
|
Mon Nov 16 09:37:41 2009 |
steve | Update | PEM | construction is getting noisier |
ATM1: Seismometers are saturating, suspensions are OK
Atm2 : activity next door, diesel Backhoe and diesel concrete cutter are running
Atm3: CES exhaust fans output is pick up by 40M-Annex-North AC unit intake. The 40m office room has some diesel smell...........see # 2377 |
Attachment 1: 4hces.png
|
|
Attachment 2: P1050734.JPG
|
|
Attachment 3: P1050736.JPG
|
|
2561
|
Tue Feb 2 16:10:09 2010 |
steve | Update | PEM | construction progress next door |
CES construction is progressing. The 40m suspensions are bearing well.
atm1, PEM vs sus plots of 120 days
atm2, big pool walls are in place, ~10 ft east of south arm
atm3, 10 ft east of ITMY
atm4, ~60 ft east of ITMY
atm5, cold weather effect of N2 evaporator tower |
Attachment 1: pem120d.jpg
|
|
Attachment 2: 02022010.JPG
|
|
Attachment 3: 02022010b.JPG
|
|
Attachment 4: 02022010c.JPG
|
|
Attachment 5: icewall.JPG
|
|
17123
|
Wed Aug 31 12:57:07 2022 |
rana | Summary | ALS | control of ALS beat freq from command line -easy |
The PZT sweeps that we've been making to characterize the ALS-X laser should probably be discarded - the DFD was not setup correctly for this during the past few months.
Since the DFD only had a peak-peak range of ~5 MHz, whenever the beat frequency drifts out of the linear range (~2-3 MHz), the data would have an arbitrary gain. Since the drift was actually more like 50 MHz, it meant that the different parts of a single sweep could have some arbitrary gain and sign !!! This is not a good way to measure things.
I used an ezcaservo to keep the beat frequency fixed. The attacehed screenshot shows the command line. We read back the unwrapped beat frequency from the phase tracker, and feedback on the PSL's NPRO temperature. During this the lasers were not locked to any cavities (shutters closed, but servos not disabled).
For the purposes of this measurement, I reduced the CAL factor in the phase tracker screen so that the reported FINE_PHASE_OUT is actually in kHz, rather than Hz on this plot. So the green plot is moving by 10's of MHz. When the servo is engaged, you can see the SLOWDC doing some action. We think the calibration of that channel is ~1 GHz/V, so 0.1 SLOWDC Volts should be ~100 MHz. I think there's a factor of 2 missing here, but its close.
As you can see in the top plot, even with the frequency stabilized by this slow feedback (-1000 to -600 seconds), the I & Q outputs are going through multiple cycles, and so they are unusable for even a non serious measurement.
The only way forward is to use less of a delay in the DFD: I think Anchal has been busily installing this shorter cable (hopefully, its ~3-5 m long so that the linear range is more. I think a 10 m cable is too long.), and the sweeps taken later today should be more useful. |
Attachment 1: Untitled.png
|
|
14873
|
Thu Sep 12 09:49:07 2019 |
gautam | Update | Computers | control rm wkstns shutdown |
Chub wanted to get the correct part number for the replacement UPS batteries which necessitated opening up the UPS. To be cautious, all the workstations were shutdown at ~9:30am while the unit is pulled out and inspected. While looking at the UPS, we found that the insulation on the main power cord is damaged at both ends. Chub will post photos.
However, despite these precautions, rossa reports some error on boot up (not the same xdisp junk that happened before). pianosa and donatella came back up just fine. It is remotely accessible (ssh-able) though so maybe we can recover it...
Quote: |
please no one touch the UPS: last time it destroyed ROSSA. Please ask Chub to order the replacement batteries so we can do this in a controlled way (fully shutting down ALL workstations first). Last time we wasted 8 hours on ROSSA rebuilding
|
|
Attachment 1: IMG_7943.JPG
|
|