16776
|
Wed Apr 13 18:55:54 2022 |
Koji | Update | Cameras | Camera Battery Test | I believe that the Nikon has an exposure problem and that's why we bought the Canon.
|
17269
|
Tue Nov 15 17:58:00 2022 |
Paco | Configuration | Cameras | POP camera realignment after IFO alignment | [Paco, Yuta]
I swapped the 1 inch BS and lenses along the POP beam to clear the apertures and avoid clipping this beam. The results are illustrated by the attached pictures; this was done right after Yuta had optimized IFO alignment so it's hopefully a good reference from now on. Yuta also tuned the alignment of BHDC path in ITMY table, which mostly improved the alignment to DCPD A (90-ish counts improved to 100-ish counts with ITMY single bounce). |
17275
|
Thu Nov 17 07:39:01 2022 |
JC | Configuration | Cameras | ITMX Camera | Coming in this morning, I found ITMX Camera malfunctioning. |
17278
|
Thu Nov 17 12:24:48 2022 |
Paco | Configuration | Cameras | ITMX Camera -- attempt at fix | I found that an old BNC cable for ITMXF video existed so I first tried swapping both ends of the cable, one on the ITMX viewport and the other one in the video MUX input in the rear. This didn't fix the issue.
I searched around in the CCD cabinet by XARM and found an identical analog camera so I swapped it and got the same image ...
I then searched for a AC/DC supply cable, but couldn't find one.
Quote: |
Coming in this morning, I found ITMX Camera malfunctioning.
|
|
17280
|
Thu Nov 17 15:53:47 2022 |
JC | Configuration | Cameras | ITMX Camera -- attempt at fix | The issue was the power supply.
Quote: |
I found that an old BNC cable for ITMXF video existed so I first tried swapping both ends of the cable, one on the ITMX viewport and the other one in the video MUX input in the rear. This didn't fix the issue.
I searched around in the CCD cabinet by XARM and found an identical analog camera so I swapped it and got the same image ...
I then searched for a AC/DC supply cable, but couldn't find one.
|
|
17422
|
Wed Jan 25 16:58:19 2023 |
Alex | Update | Cameras | Recording CCD cameras | Thus far, the software needed for the Magewell video encoder has been successfully installed on Donatella. OBS studio has also been installed and works correctly. OBS will be the video recording software that can be interfaced via command line once the SDI video encoder starts working. (https://github.com/muesli/obs-cli)
So far, the camera can not be connected to the Magewell encoder. The encoder continues to have a pulsing error light that indicates "no signal" or "signal not locked". I have begun testing on a secondary camera, directly connected to the Magewell encoder with similar errors. This may be able to be resolved once more information about the camera and its specifications/resolution is uncovered. At this time I have not found any details on the LCL-902K by Watec that was given to me by Koji. I will begin looking into the model used in the 40 meter next. |
17424
|
Thu Jan 26 00:18:54 2023 |
Koji | Update | Cameras | Recording CCD cameras | Connect any video signal supported by the adapter. Use Windows / Mac or any other OS. If it keeps complaining, contact Magwell support. |
10436
|
Thu Aug 28 11:02:53 2014 |
Steve | Update | Calibration-Repair | SR785 repair | SN 46,795 of 2003 is back. |
11641
|
Thu Sep 24 17:06:14 2015 |
ericq | Update | Calibration-Repair | C1CAL Lockins | Just a quick note for now: I've repopulated C1CAL with a limited set of lockin oscillators/demodulators, informed by the aLIGO common LSC model. Screens are updated too.
Rather than trying to do the whole magnitude phase decompostion, it just does the demodulation of the RFPD signals online; everything beyond that is up to the user to do offline.
Briefly testing with PRMI, it seems to work as expected. There is some beating evident from the fact that the MICH and PRCL oscillation frequencies are only 2Hz apart; the demod low pass is currently at an arbitrary 1Hz, so it doesn't filter the beat much.
Screens, models, etc. all svn'd. |
12040
|
Mon Mar 21 14:29:32 2016 |
Steve | Update | Calibration-Repair | 1W Innolight laser repair diagnoses |
Quote: |
Quote: |
After adjusting the alignment of the two beams onto the PD, I managed to recover a stronger beatnote of ~ -10dBm. I managed to take some measurements with the PLL locked, and will put up a more detailed post later in the evening. I turned the IMC autolocker off, turned the 11MHz Marconi output off, and closed the PSL shutter for the duration of my work, but have reverted these to their nominal state now. The are a few extra cables running from the PSL table to the area near the IOO rack where I was doing the measurements from, I've left these as is for now in case I need to take some more data later in the evening...I
|
Innolight 1W 1064nm, sn 1634 was purchased in 9-18-2006 at CIT. It came to the 40m around 2010
It's diodes should be replaced, based on it's age and performance.
RIN and noise eater bad. I will get a quote on this job.
The Innolight Manual frequency noise plot is the same as Lightwave' elog 11956
|
Diagnoses from Glasglow:
“So far we have analyzed the laser. The pump diode is degraded. Next we would replace it with a new diode. We would realign the diode output beam into the laser crystal. We check all the relevant laser parameters over the whole tuning range. Parameters include single direction operation of the ring resonator, single frequency operation, beam profile and others. If one of them is out of spec, then we would take actions accordingly. We would also monitor the output power stability over one night. Then we repackage and ship the laser.” |
12045
|
Thu Mar 24 07:56:09 2016 |
Steve | Update | Calibration-Repair | NO Noise Eater for 1W Innolight | 1W Innolight is NOT getting Noise Eater as it was decided yesterday at the 40m meeting. Corrected 3-25-2016
Repair quote with adding noise eater is in 40m wiki
Quote: |
Quote: |
Quote: |
After adjusting the alignment of the two beams onto the PD, I managed to recover a stronger beatnote of ~ -10dBm. I managed to take some measurements with the PLL locked, and will put up a more detailed post later in the evening. I turned the IMC autolocker off, turned the 11MHz Marconi output off, and closed the PSL shutter for the duration of my work, but have reverted these to their nominal state now. The are a few extra cables running from the PSL table to the area near the IOO rack where I was doing the measurements from, I've left these as is for now in case I need to take some more data later in the evening...I
|
Innolight 1W 1064nm, sn 1634 was purchased in 9-18-2006 at CIT. It came to the 40m around 2010
It's diodes should be replaced, based on it's age and performance.
RIN and noise eater bad. I will get a quote on this job.
The Innolight Manual frequency noise plot is the same as Lightwave' elog 11956
|
Diagnoses from Glasglow:
“So far we have analyzed the laser. The pump diode is degraded. Next we would replace it with a new diode. We would realign the diode output beam into the laser crystal. We check all the relevant laser parameters over the whole tuning range. Parameters include single direction operation of the ring resonator, single frequency operation, beam profile and others. If one of them is out of spec, then we would take actions accordingly. We would also monitor the output power stability over one night. Then we repackage and ship the laser.”
|
|
12070
|
Mon Apr 11 17:03:41 2016 |
Steve | Update | Calibration-Repair | 1W Innolight repair completed | The laser is back. Test report is in the 40m wiki as New Pump Diode Mephisto 1000
It will go on the PSL table. |
13456
|
Tue Nov 28 17:27:57 2017 |
awade | Bureaucracy | Calibration-Repair | SR560 return, still not charging | I brought a bunch of SR560s over for repair from Bridge labs. This unit, picture attached (SN 49698), appears to still not be retaining charge. I’ve brought it back. |
14759
|
Mon Jul 15 03:30:47 2019 |
Kruthi | Update | Calibration-Repair | White paper as a Lambertian scatterer | I made some rough measurements, using the setup I had used for CCD calibration, to get an idea of how good of a Lambertian scatterer the white paper is. Following are the values I got:
Angle (degrees) |
Photodiode reading (V) |
Ps (W) |
BRDF (per str) |
% error |
12 |
0.864 |
2.54E-06 |
0.334 |
20.5 |
24 |
0.926 |
2.72E-06 |
0.439 |
19.0 |
30 |
1.581 |
4.65E-06 |
0.528 |
19.0 |
41 |
0.94 |
2.76E-06 |
0.473 |
19.8 |
49 |
0.545 |
1.60E-06 |
0.423 |
22.5 |
63 |
0.371 |
1.09E-06 |
0.475 |
28 |
Note: All the measurements are just rough ones and are prone to larger errors than estimated.
I also measured the transmittance of the white paper sample being used (it consists of 2 white papers wrapped together). It was around 0.002 |
14804
|
Wed Jul 24 04:20:35 2019 |
Kruthi | Update | Calibration-Repair | MC2 pitch and yaw calibration | Summary: I calibrated MC2 pitch and yaw offsets to spot position in mm. Here's what I did:
- Changed the MC2 pitch and yaw offset values using ezca.Ezca().write('IOO-MC2_TRANS_PIT_OFFSET', <pitch offset value> ) and ezca.Ezca().write('IOO-MC2_TRANS_YAW_OFFSET', <yaw offset value> )
- Waited for ~ 700-800 sec for system to adjust to the assigned values
- Took snapshots with the 2 GigEs I had installed - zoomed in and zoomed out. (I'll be using these to make a scatter loss map, verify the calibration results, etc)
- Ran the mcassDecenter script, which can be found in /scripts/ASS/MC. This enters the spot position in mm in the specified text file.
Results: In the pitch/yaw vs pitch_offset/yaw_offset graph attached,
- intercept_pitch = 6.63 (in mm) , slope_pitch = -0.6055 (mm/counts)
- intercept_yaw = -4.12 (in mm) , slope_yaw = 4.958 (mm/counts)
|
15510
|
Sat Aug 8 07:36:52 2020 |
Sanika Khadkikar | Configuration | Calibration-Repair | BS Seismometer - Multi-channel calibration | Summary :
I have been working on analyzing the seismic data obtained from the 3 seismometers present in the lab. I noticed while looking at the combined time series and the gain plots of the 3 seismometers that there is some error in the calibration of the BS seismometer. The EX and the EY seismometers seem to be well-calibrated as opposed to the BS seismometer.
The calibration factors have been determined to be :
BS-X Channel: 
BS-Y Channel: 
BS-Z Channel: 
Details :
The seismometers each have 3 channels i.e X, Y, and Z for measuring the displacements in all the 3 directions. The X channels of the three seismometers should more or less be coherent in the absence of any seismic excitation with the gain amongst all the similar channels being 1. So is the case with the Y and Z channels. After analyzing multiple datasets, it was observed that the values of all the three channels of the BS seismometer differed very significantly from their corresponding channels in the EX and the EY seismometers and they were not calibrated in the region that they were found to be coherent as well.
Method :
Note: All the frequency domain plots that have been calculated are for a sampling rate of 32 Hz. The plots were found to be extremely coherent in a certain frequency range i.e ~0.1 Hz to 2 Hz so this frequency range is used to understand the relative calibration errors. The spread around the function is because of the error caused by coherence values differing from unity and the averages performed for the Welch function. 9 averages have been performed for the following analysis keeping in mind the needed frequency resolution(~0.01Hz) and the accuracy of the power calculated at every frequency.
- I first analyzed the regions in which the similar channels were found to be coherent to have a proper gain analysis. The EY seismometer was found to be the most stable one so it has been used as a reference. I saw the coherence between similar channels of the 2 seismometers and the bode plots together. A transfer function estimator was used to analyze the relative calibration in between all 3 pairs of seismometers. In the given frequency range EX and EY have a gain of 1 so their relative calibration is proper. The relative calibration in between the BS and the EY seismometers is not proper as the resultant gain is not 1. The attached plots show the discrepancies clearly :
- BS-X & EY-X Transfer Function : Attachment #1
- BS-Y & EY-Y Transfer Function : Attachment #2
The gain in the given frequency range is ~3. The phase plotting also shows a 180-degree phase as opposed to 0 so a negative sign would also be required in the calibration factor. Thus the calibration factor for the Y channel of the BS seismometer should be around ~3.
- BS-Z & EY-Z Transfer Function : Attachment #3
The mean value of the gain in the given frequency range is the desired calibration factor and the error would be the mean of the error for the gain dataset chosen which is caused due to factors mentioned above.
Note: The standard error envelope plotted in the attached graphs is calculated as follows :
1. Divide the data into n segments according to the resolution wanted for the Welch averaging to be performed later.
2. Calculate PSD for every segment (no averaging).
3. Calculate the standard error for every value in the data segment by looking at distribution formed by the n number values we obtain by taking that respective value from every segment.
Discussions :
The BS seismometer is a different model than the EX and the EY seismometers which might be a major cause as to why we need special calibration for the BS seismometer while EX and EY are fine. The sign flip in the BS-Y seismometer may cause a lot of errors in future data acquisitions. The time series plots in Attachment #4 shows an evident DC offset present in the data. All of the information mentioned above indicates that there is some electrical or mechanical defect present in the seismometer and may require a reset. Kindly let me know if and when the seismometer is reset so that I can calibrate it again. |
15650
|
Thu Oct 29 09:50:12 2020 |
anchal | Summary | Calibration | Preliminary calibration measurement taken | I went to 40m yesterday at around 2:30 pm and Koji showed me how to acquire lock in different arms and for different lasers. Finally, we took a preliminary measurement of shaking the ETMX at some discrete frequencies and looking at the beatnote frequency spectrum of X-end laser's fiber-coupled IR and Main laser's IR pick-off.
Basic controls and measurement 101 at 40m
- I learned a few things from Koji about how to align the cavity mirrors for green laser or IR laser.
- I learned how to use ASS and how to align the green end laser to the cavity. I also found out about the window at ETMX chamber where we can directly see the cavity mode, cool stuff.
- Koji also showed me around on how to use diaggui and awggui for taking measurements with any of the channels.
Preliminary measurement for calibration scheme
We verified that we can send discrete frequency excitation signals to ETMX actuators directly and see a corresponding peak in the spectrum of beatnote frequency between fiber-coupled X-end IR laser and main laser IR pickoff.
- I sent excitation signal at 200 Hz, 250 Hz and 270 Hz at C1:SUS-ETMX_LSC_EXC channel using awggui with an amplitude of 100 cts and gain of 2.
- I measured corresponding peaks in the beatnote spectrum using diaggui.
- Page 1 shows the ASD data for the 4 measurements taken with Hanning window and averaging of 10.
- Page 2 shows close up Spectrum data for the 4 measurements taken with flattop window and averaging of 10.
- I converted this frequency signal into displacement by using conversion factor
or .
If full interferometer had been locked, we could have used the DARM error signal output to calibrate it against this measurement.
Data |
16128
|
Mon May 10 10:57:54 2021 |
Anchal, Paco | Summary | Calibration | Using ALS beatnote for calibration, test | Test details:
- We locked both arms and opened the shutter for Yend green laser.
- After toggling the shutter on.off, we got a TEM00 mode of green laser locked to YARM.
- We then cleared the phase Y history by clicking "CLEAR PHASE Y HISTROY" on C1LSC_ALS.adl (opened from sitemap > ALS > ALS).
- We sent excitation signal at ITMY_LSC_EXC using awggui at 43Hz, 77Hz and 57Hz.
- We measured the power spectrum and coherence of C1:ALS-BEATY_FINE_PHASE_OUT_HZ_DQ and C1:SUS-ITMY_LSC_OUT_DQ.
- The BEATY_FINE_PHASE_OUT_HZ is already calibrated in Hz. This we assume is done by multip[lying the VCO slope in Hz/cts to the error signal of the digital PLL loop that tracks the phase of beatnote.
- We calibrated C1:SUS-ITMY_LSC_OUT_DQ by multiplying with
where f is in Hz.
The 2.44/f2 nm/cts is taken from 13984.
- We added the calibration as Poles/zeros option in diaggui using gain=54.577e3 and poles as "0, 0".
- We found that ITMY_LSC_OUT_DQ calibration matches well at 57Hz but overshoots (80 vs 40) at 43 Hz and undershoots (50 vs 80) at 77Hz.
Conclusions:
- If we had DRFPMI locked, we could have used the beatnote spectrum as independent measurement of arm lengths to calibrate the interferometer output.
- We can also use the beatnote to confirm or correct the ITM actuator calibrations. Maybe shape is not exactly 1/f2 unless we did something wrong here or the PLL bandwidth is too short.
|
16315
|
Tue Sep 7 18:00:54 2021 |
Tega | Summary | Calibration | System Identification via line injection | [paco]
This morning, I spent some time restoring the jupyter notebook server running in allegra. This server was first set up by Anchal to be able to use the latest nds python API tools which is handy for the calibration stuff. The process to restore the environment was to run "source ~/bashrc.d/*" to restore some of the aliases, variables, paths, etc... that made the nds server work. I then ran ssh -N -f -L localhost:8888:localhost:8888 controls@allegra from pianosa and carry on with the experiment.
[paco, hang, tega]
We started a notebook under /users/paco/20210906_XARM_Cal/XARM_Cal.ipynb on which the first part was doing the following;
- Set up list of excitations for C1:LSC-XARM_EXC (for example three sine waveforms) using awg.py
- Make sure the arm is locked
- Read a reference time trace of the C1:LSC-XARM_IN2 channel for some duration
- Start excitations (one by one at the moment, ramptime ~ 3 seconds, same duration as above)
- Get data for C1:LSC-XARM_IN2 for an equal duration (raw data in Attachment #1)
- Generate the excitation sine and cosine waveforms using numpy and demodulate the raw timeseries using a 4th order lowpass filter with fc ~ 10 Hz
- Estimate the correct demod phase by computing arctan(Q / I) and rerunning the demodulation to dump the information into the I quadrature (Attachment #2).
- Plot the estimated ASD of all the quadratures (Attachment #3)
[paco, hang, tega]
Estimation of open loop gain:
- Grab data from the C1:LSC-XARM_IN1 and C1:LSC-XARM_IN2 test points
- Infer excitation from their differnce, i.e. C1:LSC-XARM_EXC = C1:LSC-XARM_IN2 - C1:LSC-XARM_IN1
- Compute the open loop gain as follows : G(f) = csd(EXC,IN1)/csd(EXC,IN2), where csd computes the cross spectra density of the input arguments
- For the uncertainty in G, dG, we repeat steps (1) to (3) with & without signal injection in the C1:LSC-XARM_EXC channel. In the absence of signal injection, the signal in C1:LSC-XARM_IN2 is of the form: Y_ref = Noise/(1-G), whereas with nonzero signal injection, the signal in C1:LSC-XARM_IN2 has the form: Y_cal = EXC/(1-G) + Noise/(1-G), so their ratio, Y_cal/Y_ref = EXC/Noise, gives the SNR, which we can then invert to give the uncertainty in our estimation of G, i.e dG = Y_ref/Y_cal.
- For the excitation at 53 Hz, our measurtement for the open loop gain comes out to about 5 dB whiich is consistent with previous measurement.
- We seem to have an SNR in excess of 100 at measurement time of 35 seconds and 1 count of amplitude which gives a relative uncertainty of G of 0.1%
- The analysis details are ongoing. Feedback is welcome.
|
16352
|
Tue Sep 21 11:13:01 2021 |
Paco | Summary | Calibration | XARM calibration noise | Here are some plots from analyzing the C1:LSC-XARM calibration. The experiment is done with the XARM (POX) locked, a single line is injected at C1:LSC-XARM_EXC at f0 with some amplitude determined empirically using diaggui and awggui tools. For the analysis detailed in this post, f0 = 19 Hz, amp = 1 count, and gain = 300 (anything larger in amplitude would break the lock, and anything lower in frequency would not show up because of loop supression). Clearly, from Attachment #3 below, the calibration line can be detected with SNR > 1.
We read the test point right after the excitation C1:LSC-XARM_IN2 which, in a simplified loop will carry the excitation suppressed by 1 - OLTF, the open loop transfer function. The line is on for 5 minutes, and then we read for another 5 minutes but with the excitation off to have a reference. Both the calibration and reference signal time series are shown in Attachment #1 (decimated by 8). The corresponding ASDs are shown in Attachment #2. Then, we demodulate at 19 Hz and a 30 Hz, 4th-order butterworth LPF, and get an I and Q timeseries (shown in Attachment #3). Even though they look similar, the Q is centered about 0.2 counts, while the I is centered about 0.0. From this time series, we can of course show the noise ASDs in Attachment #3.
The ASD uncertainty bands in the last plot are statistical estimates and depend on the number of segments used in estimating the PSD. A thing to note is that the noise features surrounding the signal ASD around f0 are translated into the ASD in the demodulated signals, but now around dc. I guess from Attachment #3 there is no difference in the noise spectra around the calibration line with and without the excitation. This is what I would have expected from a linear system. If there was a systematic contribution, I would expect it to show at very low frequencies. |
16353
|
Wed Sep 22 11:43:04 2021 |
rana | Summary | Calibration | XARM calibration noise | I would expect to see some lower frequency effects. i.e. we should look at the timeseries of the demod with the excitation on and off.
I would guess tat the exc on should show us the variations in the optical gain below 3 Hz, whereas the exc off would not show it.
Maybe you should do some low pass filtering on the time series you have to see the ~DC effects? Also, reconsider your AA filter design: how do you quantitatively choose the cutoff frequency and stopband depth? |
16363
|
Tue Sep 28 16:31:52 2021 |
Paco | Summary | Calibration | XARM OLTF (calibration) at 55.511 Hz | [anchal, paco]
Here is a demonstration of the methods leading to the single (X)arm calibration with its budget uncertainty. The steps towards this measurement are the following:
- We put a single line excitation through the C1:SUS-ETMX_LSC_EXC at 55.511 Hz, amp = 1 counts, gain = 300 (ramptime=10 s).
- With the arm locked, we grab a long timeseries of the C1:LSC-XARM_IN1_DQ (error point) and C1:SUS-ETMX_LSC_OUT_DQ (control point) channels.
- We assume the single arm loop to have the four blocks shown in Attachment #1, A (actuator + sus), plant (mainly the cavity pole), D (detection + electronics), and K (digital control).
- At this point, Anchal made a model of the single arm loop including the appropriate filter coefficients and other parameters. See Attachments #2-3 for the split and total model TFs.
- Our line would actually probe a TF from point b (error point) to point d (control point). We multiplied our measurement with open loop TF from b to d from model to get complete OLTF.
- Our initial estimate from documents and elog made overall loop shape correct but it was off by an overall gain factor. This could be due to wrong assumption on RFPD transimpedance or analog gains of AA or whitening filters. We have corrected for this factor in the RFPD transimpedance, but this needs to be checked (if we really care).
- We demodulate decimated timeseries (final sampling rate ~ 2.048 kHz) and I & Q for both the b and d signals. From this and our model for K, we estimate the OLTF. Attachment #4 shows timeseries for magnitude and phase.
- Finally, we compute the ASD for the OLTF magnitude. We plot it in Attachment #5 together with the ASD of the XARM transmission (C1:LSC-TRX_OUT_DQ) times the OLTF to estimate the optical gain noise ASD (this last step was a quick attempt at budgeting the calibration noise).
- For each ASD we used N = 24 averages, from which we estimate rms (statistical) uncertainties which are depicted by error bands (
) around the lines.
** Note: We ran the same procedure using dtt (diaggui) to validate our estimates at every point, as well as check our SNR in b and d before taking the ~3.5 hours of data. |
16369
|
Thu Sep 30 18:04:31 2021 |
Paco | Summary | Calibration | XARM OLTF (calibration) with three lines | [anchal, paco]
We repeated the same procedure as before, but with 3 different lines at 55.511, 154.11, and 1071.11 Hz. We overlay the OLTF magnitudes and phases with our latest model (which we have updated with Koji's help) and include the rms uncertainties as errorbars in Attachment #1.
We also plot the noise ASDs of calibrated OLTF magnitudes at the line frequencies in Attachment #2. These curves are created by calculating power spectral density of timeseries of OLTF values at the line frequencies generated by demodulated XARM_IN and ETMX_LSC_OUT signals. We have overlayed the TRX noise spectrum here as an attempt to see if we can budget the noise measured in values of G to the fluctuation in optical gain due to changing power in the arms. We multiplied the the transmission ASD with the value of OLTF at those frequencies as the transfger function from normalized optical gain to the total transfer function value.
It is weird that the fluctuations in transmission power at 1 mHz always crosses the total noise in the OLTF value in all calibration lines. This could be an artificat of our data analysis though.
Even if the contribution of the fluctuating power is correct, there is remaining excess noise in the OLTF to be budgeted. |
16373
|
Mon Oct 4 15:50:31 2021 |
Hang | Update | Calibration | Fisher matrix estimation on XARM parameters | [Anchal, Hang]
What: Anchal and I measured the XARM OLTF last Thursday.
Goal: 1. measure the 2 zeros and 2 poles in the analog whitening filter, and potentially constrain the cavity pole and an overall gain.
2. Compare the parameter distribution obtained from measurements and that estimated analytically from the Fisher matrix calculation.
3. Obtain the optimized excitation spectrum for future measurements.
How: we inject at C1:SUS-ETMX_LSC_EXC so that each digital count should be directly proportional to the force applied to the suspension. We read out the signal at C1:SUS-ETMX_LSC_OUT_DQ. We use an approximately white excitation in the 50-300 Hz band, and intentionally choose the coherence to be only slightly above 0.9 so that we can get some statistical error to be compared with the Fisher matrix's prediction. For each measurement, we use a bandwidth of 0.25 Hz and 10 averages (no overlapping between adjacent segments).
The 2 zeros and 2 poles in the analog whitening filter and an overall gain are treated as free parameters to be fitted, while the rest are taken from the model by Anchal and Paco (elog:16363). The optical response of the arm cavity seems missing in that model, and thus we additionally include a real pole (for the cavity pole) in the model we fit. Thus in total, our model has 6 free parameters, 2 zeros, 3 poles, and 1 overall gain.
The analysis codes are pushed to the 40m/sysID repo.
===========================================================
Results:
Fig. 1 shows one measurement. The gray trace is the data and the olive one is the maximum likelihood estimation. The uncertainty for each frequency bin is shown in the shaded region. Note that the SNR is related to the coherence as
SNR^2 = [coherence / (1-coherence)] * (# of average),
and for a complex TF written as G = A * exp[1j*Phi], one can show the uncertainty is given by
\Delta A / A = 1/SNR, \Delta \Phi = 1/SNR [rad].
Fig. 2. The gray contours show the 1- and 2-sigma levels of the model parameters using the Fisher matrix calculation. We repeated the measurement shown in Fig. 1 three times, and the best-fit parameters for each measurement are indicated in the red-crosses. Although we only did a small number of experiments, the amount of scattering is consistent with the Fisher matrix's prediction, giving us some confidence in our analytical calculation.
One thing to note though is that in order to fit the measured data, we would need an additional pole at around 1,500 Hz. This seems a bit low for the cavity pole frequency. For aLIGO w/ 4km arms, the single-arm pole is about 40-50 Hz. The arm is 100 times shorter here and I would naively expect the cavity pole to be at 3k-4k Hz if the test masses are similar.
Fig. 3. We then follow the algorithm outlined in Pintelon & Schoukens, sec. 5.4.2.2, to calculate how we should change the excitation spectrum. Note that here we are fixing the rms of the force applied to the suspension constant.
Fig. 4 then shows how the expected error changes as we optimize the excitation. It seems in this case a white-ish excitation is already decent (as the TF itself is quite flat in the range of interest), and we only get some mild improvement as we iterate the excitation spectra (note we use the color gray, olive, and purple for the results after the 0th, 1st, and 2nd iteration; same color-coding as in Fig. 3).
|
16399
|
Wed Oct 13 15:36:38 2021 |
Hang | Update | Calibration | XARM OLTF | We did a few quick XARM oltf measurements. We excited C1:LSC-ETMX_EXC with a broadband white noise upto 4 kHz. The timestamps for the measurements are: 1318199043 (start) - 1318199427 (end).
We will process the measurement to compute the cavity pole and analog filter poles & zeros later. |
16957
|
Tue Jun 28 17:07:47 2022 |
Anchal | Update | Calibration | Added Beatnote channels in demodulation of c1cal | I added today demodulation of C1:LSC-BEATX/Y_FINE_I/Q in the c1cal demodulation where different degrees of freedom can be dithered. For McCal (formerly soCal), we'll dither the arm cavity for which we can use any of the DOFs (like DARM) to send the dither to ETMX/ETMY. Then with green laser locked as well, we'll get the calibration signal from the beatnotes in the demodulaed channels. We can also read right after the mixing in c1cal model and try differnt poles for integration .
I've also added medm screens in the sensing matrix part of LSC screen. These let you see demodulation of beatnote frequency signals. |
17010
|
Mon Jul 18 04:42:54 2022 |
Anchal | Update | Calibration | Error propagation to astrophysical parameters from detector calibration uncertainty | We can calculate how much detector calibration uncertainty affects the estimation of astrophysical parameters using the following method:
Let be set of astrophysical parameters (like component masses, distance etc), be set of detector parameters (like detector pole, gain or simply transfer function vaue for each frequency bin). If true GW waveform is given by , and the detector transfer function is given by , then the detected gravitational waveform becomes:

One can calculate a derivative of waveform with respect to the different parameters and calculate Fisher matrix as (see correction in 40m/17017):

where the bracket denotes iner product defined as:

where is strain noise PSD of the detector.
With the gamma matrix in hand, the error propagation from detector parameter fractional errors to astrophysical paramter fractional errors is given by (eq 26 in Evan et al 2019 Class. Quantum Grav. 36 205006):

where and .
Using the above mentioned formalism, I looked into two ways of calculating error propagation from detector calibration error to astrophysical paramter estimations:
Using detector response function model:
If we assume detector response function as a simple DC gain (4.2 W/nm) and one pole (500 Hz) transfer function, we can plot conversion of pole frequency error into astrophysical parameter errors. I took two cases:
- Binary Neutron Star merger with star masses of 1.3 and 1.35 solar masses at 100 Mpc distance with a
of 500. (Attachment 1)
- Binary black hole merger with black masses of 35 and 30 at 400 MPc distance with spin along z direction of 0.5 and 0.8. (I do not fully understand the meaning of these spin components but a pycbc waveform generation model still lets me calculate the effect of detector errors) (Attachment 2)
The plots are plotted in both loglog and linear plots to show the order of magnitude effect and how the error propsagation slope is different for different parameters. 'm still not sure which way is the best to convey the information. The way to read this plot is for a given error say 4% in pole frequency determination, what is the expected error in component masses, merger distance etc. I
Note that the overall gain of detector response is not sensitive to astrophysical error estimation.
Using detector transfer function as frequency bin wise multi-parameter function
Alternatively, we can choose to not fit any model to the detector transfer function and simply use the errors in magnitude and phase at each frequency point as an independent parameter in the above formalism. This then lets us see what is the error propagation slope for each frequency point. The hope is to identify which parts of the calibration function are more important to calibrate with low uncertainty to have the least effect on astrophysical parameter estimation. Attachment 3 and 4 show these plots for BNS and BBH cases mentioned above. The top panel is the error propagation slope at each frequency due to error in magnitude of the detector transfer function at that frequency and the bottom panel is the error propagation slope at each frequency due to error in phase of the detector transfer function.
The calibration error in magnitude and phase as a function of frequency would be multiplied by the curves and summed together, to get total uncertainty in each parameter estimation.
This is my first attempt at this problem, so I expect to have made some mistakes. Please let me know if you can point out any. Like, do the order of magnitude and shape of error propagation makes sense? Also, comments/suggestions on the inference of these plots would be helpful.
Finally, I haven't yet tried seeing how these curves change for different true values of the merger event parameters. I'm not yet sure what is the best way to extract some general information for a variety of merger parameters.
Future goals are to utilize this information in informing system identification method i.e. multicolor calibration scheme parameters like calibration line frequencies and strength.
Code location |
17011
|
Mon Jul 18 15:17:51 2022 |
Hang | Update | Calibration | Error propagation to astrophysical parameters from detector calibration uncertainty | 1. In the error propogation equation, it should be \Delta \Theta = -H^{-1} M \Delta \Lambda, instead of the fractional error.
2. For the astro parameters, in general you would need t_c for the time of coalescence and \phi_c for the phase. See, e.g., https://ui.adsabs.harvard.edu/abs/1994PhRvD..49.2658C/abstract.
3. Fig. 1 looks very nice to me, yet I don't understand Fig. 3... Why would phase or amplitude uncertainties at 30 Hz affect the tidal deformability? The tide should be visible only > 500 Hz.
4. For BBH, we don't measure individual spin well but only their mass-weighted sum, \chi_eff = (m_1*a_1 + m_2*a_2)/(m_1 + m_2). If you treat S1z and S2z as free parameters, your matrix is likely degenerate. Might want to double-check. Also, for a BBH, you don't need to extend the signal much higher than \omega ~ 0.4/M_tot ~ 10^4 Hz * (Ms/M_tot). So if the total mass is ~ 100 Ms, then the highest frequency should be ~ 100 Hz. Above this number there is no signal.
|
17017
|
Tue Jul 19 07:34:46 2022 |
Anchal | Update | Calibration | Error propagation to astrophysical parameters from detector calibration uncertainty | Addressing the comments as numbered:
- Yeah, that's correct, that equation normally
but it is different if I define bit differently that I did in the code, correct my definition of to :

then the relation between fractional errors of detector parameter and astrophysical parameters is:

I prefer this as the relation between fractional errors is a dimensionless way to see it.
- Thanks for pointing this out. I didn't see these parameters used anywhere in the examples (in fact there is no t_c in documentation even though it works). Using these did not affect the shape of error propagation slope function vs frequency but reduced the slope for chirped Mass
by a couple of order of magnitudes.
- I used the get_t_merger(f_gw, M1, M2) function from Hang's work to calculate t_c by assuming
must be the lowest frequency that comes within the detection band during inspiral. This function is:

For my calculations, I've taken as 20 Hz.
- I used the get_f_gw_2(f_gw_1, M1, M2, t) function from Hang's work to calculate the evolution of the frequency of the IMR defined as:

where is the frequency at t=0. I integrated this frequency evolution for t_c time to get the coalescence phase phi_c as:

- In Fig 1, which representation makes more sense, loglog of linear axis plot? Regarding the affect of uncertainties on Tidal amplitude below 500 Hz, I agree that I was also expecting more contribution from higher frequencies. I did find one bug in my code that I corrected but it did not affect this point. Maybe the SNR of chosen BNS parameters (which is ~28) is too low for tidal information to come reliably anyways and the curve is just an inverse of the strain noise PSD, that is all the information is dumped below statistical noise. Maybe someone else can also take a look at get_fisher2() function that I wrote to do this calculation.
- Now, I have made BBH parameters such that the spin of the two black holes would be assumed the same along z. You were right, the gamma matrix was degenerate before. To your second point, I think the curve also shows that above ~200 Hz, there is not much contribution to the uncertainty of any parameter, and it rolls-off very steeply. I've reduced the yspan of the plot to see the details of the curve in the relevant region.
Quote: |
1. In the error propogation equation, it should be \Delta \Theta = -H^{-1} M \Delta \Lambda, instead of the fractional error.
2. For the astro parameters, in general you would need t_c for the time of coalescence and \phi_c for the phase. See, e.g., https://ui.adsabs.harvard.edu/abs/1994PhRvD..49.2658C/abstract.
3. Fig. 1 looks very nice to me, yet I don't understand Fig. 3... Why would phase or amplitude uncertainties at 30 Hz affect the tidal deformability? The tide should be visible only > 500 Hz.
4. For BBH, we don't measure individual spin well but only their mass-weighted sum, \chi_eff = (m_1*a_1 + m_2*a_2)/(m_1 + m_2). If you treat S1z and S2z as free parameters, your matrix is likely degenerate. Might want to double-check. Also, for a BBH, you don't need to extend the signal much higher than \omega ~ 0.4/M_tot ~ 10^4 Hz * (Ms/M_tot). So if the total mass is ~ 100 Ms, then the highest frequency should be ~ 100 Hz. Above this number there is no signal.
|
|
17029
|
Sun Jul 24 08:56:01 2022 |
Hang | Update | Calibration | Error propagation to astrophysical parameters from detector calibration uncertainty | Sorry I forgot to put tc & phic in the example.
I modified astroFisherLib.py to include these parameters. Please note that their meaning is that we don't know when the signal happens and at which phase it merges.
It does not mean the time & phase from a reference frequency to the merger. This part is not free to vary because it is fixed by the intrinsic parameters.
It might be good to have a quick scan through the Cutler & Flanagan 94 paper to better understand their physical meanings.
|
17221
|
Wed Nov 2 16:34:56 2022 |
Paco | Summary | Calibration | Single arm calibration run | [Anchal, Paco]
We added a notch filter on ETMY (the actuation point of the YARM control loop) to inject our calibration line at 575.170 Hz. The excitation is injected using the DARM Oscillator, with an exc. gain of ~ 500 (this gets us a decent > 10 SNR line in the ALS Y beat). With the arm cavity locked to the PSL (~150 Hz control bandwidth), and the aux laser locked to the cavity (~10 kHz control bandwidth) the goal of this run is to calibrate our actuator strength and more importantly to budget its uncertainty. For this we have looked at the ALS beat stability using Allan statistics; we noticed the ALS beatnote frequency fluctuations start to become dominated by 1/f (or divergent noise due to systematic drifts in the YARM loop) after 10 seconds (see Attachment #1) (we have managed to see 30 seconds stability with the HEPAs off and without locking to IMC).
Our prediction is that our demodulated calibration lines will display the least residual rms noise when averaging down to around this time. This is the only reason one would use allan statistics; to quantify the separation between statistical and systematic effects in a frequency measurement. To be continued...
gpstimes:
- 1351464997 to 1351467139
- 1351467259 to 1351468221
- 1351468318 to ...
|
17253
|
Thu Nov 10 17:40:31 2022 |
Paco | Summary | Calibration | Calibration Plan | Plan to calibrate single arm actuation strength
- Lock single arm cavity (e.g. YARM)
- Lock YAUX laser to arm cavity (actuation point is ETMY)
- With the notch on the YARM loop filter (actually on ETMY),
- Turn on cal line (e.g. DARM osc) to move ITMY; here the frequency is chosen to be away from 600 Hz (line harmonic) and from violin modes for ITMY (642 Hz). The lower value of 575.17 Hz was chosen to avoid demodulating noise peaks at 455 Hz and 700 Hz.
- Get raw YALS beatnote (we chose the demod angle of -35 deg to minimize Q).
The analysis is as follows:
- Get demodulated IQ timeseries for the duration of the locks before lowpass filter (C1:CAL-SENSMAT_DARM_BEATYF_I_DEMOD_I_IN1); we are also storing the raw beatnote if we want to do software demodulation.
- Look at the allan deviation of I and Q to establish the timescale over which our measurement is dominated by statistical uncertainty -- after this time, the uncertainty is expected to be due to systematic error / drift. In this case as shown by Attachment #1 the time is around 60.6 seconds.
- At this frequency and with 500 gain the ITMY coils should be actuating 7.32 pm of amplitude displacement.
- The minimum allan deviation does indeed predict the statistical uncertainty limited rms if we look at the power spectra of the demodulated cal line over different time periods (Attachment #2), notice I lowpassed the raw timeseries.
- I think the next step is to get the nominal calibration value and repeat the measurment for more than a single cal line.
- Roughly from the deviation plot, our fractional beatnote deviation is a proxy for the calibration uncertainty. 1.15e-16 of beatnote stability should translate to a fractional displacement stability of ~4.57e-15 at 60 seconds; giving an ultimate statistical calibration uncertainty of 0.06% at this particular frequency when averaging for this long. It might be interesting to see a calibration frequency dependent allan deviation plot.
|
17257
|
Fri Nov 11 14:15:45 2022 |
Paco | Summary | Calibration | Single arm cal with 5 lines | I turned all the LSC oscillators on and used the digital demod for BEATYF (fine y als beat) to grab the data. For this I added notches onto SCY ETMY LSC filter banks FM6-10 to account for these lines at 30.92, 211.10, 313.31, 315.17 Hz (basically just reusing the osc models) and adjusted the sensing matrix to actuate on ITMY.
I aligned and locked YARM, and then I aligned and locked the YAUX. The lock seems pretty robust with an avg green transmission GTRY ~ 0.185 counts for TEM00.
Trying to see other lines appear on the BEATYF demod channels, but so far no luck. I scaled down the exc gain from 500 counts (snr ~ 20 at 575 Hz) and verified the notches are working. Since I am unsure of the issue here and WFS tests are happening at 4 today, I decided to take some beat data under different conditions -->
HEPA OFF and PSL Shutter Open
|
gpstime start = 1352244763 |
gpstime end = 1352245405 |
HEPA OFF and
PSL Shutter Closed
|
gpstime start = 1352245574 |
gpstime end = 1352246216
|
HEPA ON and
PSL Shutter Closed
|
gpstime start = 1352246240 |
gpstime end = 1352246882 |
|
17266
|
Tue Nov 15 11:04:01 2022 |
Paco | Summary | Calibration | Single arm cal with 5 lines | YALS Hardware inspection
The ALS Cal for ITMY actuation was off by ~ 1000, so I decided I don't trust / understand what this beatnote is seeing. Then, I went in the lab to inspect things;
- ALS DFD and DEMOD: The demod box was off
perhaps on purpose, more likely by accident... the switch was off in the rear of the 1U box in the LSC rack... Also, the DB9 cable labeled ALS was disconnected. Fixed both these bugs and verified it worked all the way into cds.
- YARM Green injection: Did some re-alignment, and noted the mode was hopping a bit too much (once every couple of seconds) so I rotated the half waveplate before the green PZT steering mirrors by ~ 8 deg and used the latter to get a GTRY transmission of > 0.320 (counts), about 75% more than last time. Finally I made sure the mode is robustly locked for several minutes.
Beatnote calibration
The factor above may be explained by the bogus signals coming into the beat fine phase channels on the ALS model. After locking the YARM with POY11, and locking the YAUX to the YARM cavity, I turned on the LSC oscillators -- all five of them see Attachment #1 for the screenshot -- and looked for the lines in the C1:ALS-BEATY_FINE_PHASE_OUT channel. Here, again the sensing output matrix was set up to actuate on ITMY, while the ETMY (control point of YARM loop) had all the output notches on. Once all lines were visible in the YAUX beatnote, I had to reduce the LSC filter gain from 0.012 to 0.011 to prevent loop oscillations... Then I recorded the gpstimes below with different conditions.
- HEPA ON (JC Inside lab)
- gpstime = 1352575798 to 1352576046
- HEPA OFF (JC Inside lab)
- gpstime = 1352576125 to 1352576216
- HEPA OFF (JC in the control room)
- gpstime = 1352576641 to 1352577591
Analysis
Basically, only the DARM line was recorded (DQ channs) so I modified the c1cal to store the SIG_OUT and DEMOD_I_IN1 channels for both BEATX and BEATY cal signals. This means I need to repeat this measurement. In the meantime I am also going to try and rerun calibrate the BEAT HZ transfer function. |
17291
|
Mon Nov 21 11:52:50 2022 |
Radhika | Summary | Calibration | Single arm cal with 5 lines | [Paco, Radhika]
We set out to realign the YARM AUX laser input into the arm cavity.
- We noticed that the GTRY beam was way off the center of the screen, so we went to the vertex table to align the camera.
- The beam spot at GTRY PD was large/divergent, so we shifted the PD closer to the penultimate mirror. We also doubled the PD gain. Transmission went from ~0.3 to ~0.7 (with gain doubled).
- We returned to the YARM end table to finalize alignment with the green PZT steering mirrors. GTRY was maximized to ~0.77. |
17328
|
Wed Nov 30 20:01:08 2022 |
rana | Summary | Calibration | Single arm cal with 5 lines | I don't think you need to record the excitations. They are just sine waves. The amplitude you can read off from the OSC screen. You just have to have the BEAT channel recorded and you can demod it to get the calibration. If the BEAT channel is calibrated in Hz, and you know the 40m arm length, then you're all done.
Quote: |
Analysis
Basically, only the DARM line was recorded (DQ channs) so I modified the c1cal to store the SIG_OUT and DEMOD_I_IN1 channels for both BEATX and BEATY cal signals. This means I need to repeat this measurement. In the meantime I am also going to try and rerun calibrate the BEAT HZ transfer function.
|
|
17329
|
Thu Dec 1 20:43:25 2022 |
Anchal | Summary | Calibration | Single arm cal with 5 lines | [Anchal, Paco]
We are doing this attempt again in following configuration:
- PSL shutter is closed. (So IR laser is free running)
- Beanote frequency between Y arm and Main laser is about 45 MHz.
- Green laser on Y end is locked. Transmission is above 1.1 (C1:ALS-TRY_OUT)
- All calibration oscillators are turned on and set to actuate ITMY. See screenshot attached.
- The calibration model was changed to demodulate the C1:ALS-BEATY_FINE_PHASE_OUT channel insteald. We'll have DQ channels before mixing with oscillator, after mixing, and also after applying a 4th order 30 Hz butterworth filter.
Start time:
PST: 2022-12-01 20:44:23.982114 PST
UTC: 2022-12-02 04:44:23.982114 UTC
GPS: 1353991481.982114
Stop time:
PST: 2022-12-02 14:32:29.547603 PST
UTC: 2022-12-02 22:32:29.547603 UTC
GPS: 1354055567.547603 |
17346
|
Thu Dec 8 16:21:40 2022 |
Paco | Summary | Calibration | ITMY actuation strength cal with 5 lines | [Anchal, Paco]
After debugging the hardware, on gpstime 1354422834 we turned on 5 cal lines on ITMY to test the ALS calibration for the single arm along with our error estimates.
Note: the YARM IR lock lasted > 8 hours, but the GRY transmission dropped twice during the evening and hopped back up, so the phase tracker jumped a couple of times.
Configuration
YAUX laser was locked to the YARM through the analog PDH servo (UGF ~ 2 kHz), YARM was locked to the PSL with POY11 (UGF ~ 200 Hz), and the ALS phase tracker was set to output the beat frequency noise in Hz. HEPA was left on during this measurement. The oscillators were similar to previous instances: gains of 70@211.1Hz, 100@313.31Hz, 100@315.17Hz, 300@575.17Hz and 15@30.92Hz with appropriate notches on ETMY to avoid POY11 loop supression.
Analysis
For YARM, the high bandwidth YAUX laser loop with transfer function G ensures that the relative laser frequency fluctuations correlate with the relative length fluctuations as:

Then, getting the magnitude of the YARM displacement at calibration frequencies is possible by knowing the arm cavity length, open loop gain, and absolute frequency (wavelength). The relative calibration error on the magnitude of the displacement is
![\frac{\Delta \lvert \delta L\lvert}{\lvert \delta L \lvert} = \left[ \left(\frac{\Delta {L}}{L}\right)^2+ \left(\frac{\Delta {\lambda}}{\lambda}\right)^2 + \left(\frac{\Delta {{\delta \nu}}}{{\delta \nu}}\right)^2 + \left(\frac{\Delta \lvert G \lvert}{\lvert G \lvert(\lvert G \lvert - 1)}\right)^2 \right]^{1/2}](https://latex.codecogs.com/gif.latex?%5Cfrac%7B%5CDelta%20%5Clvert%20%5Cdelta%20L%5Clvert%7D%7B%5Clvert%20%5Cdelta%20L%20%5Clvert%7D%20%3D%20%5Cleft%5B%20%5Cleft%28%5Cfrac%7B%5CDelta%20%7BL%7D%7D%7BL%7D%5Cright%29%5E2+%20%5Cleft%28%5Cfrac%7B%5CDelta%20%7B%5Clambda%7D%7D%7B%5Clambda%7D%5Cright%29%5E2%20+%20%5Cleft%28%5Cfrac%7B%5CDelta%20%7B%7B%5Cdelta%20%5Cnu%7D%7D%7D%7B%7B%5Cdelta%20%5Cnu%7D%7D%5Cright%29%5E2%20+%20%5Cleft%28%5Cfrac%7B%5CDelta%20%5Clvert%20G%20%5Clvert%7D%7B%5Clvert%20G%20%5Clvert%28%5Clvert%20G%20%5Clvert%20-%201%29%7D%5Cright%29%5E2%20%5Cright%5D%5E%7B1/2%7D)
including the relative uncertainties in the YARM length, wavelength, and open loop gain. Interestingly, the loop gain term weighs proportionally less as G increases, so even if G = 100 (10), its relative error contribution would be < 1%. To estimate our total error, we assume the wavelength and YARM length are 1064.1(5) and 37.79(1), and add the frequency dependent values for G with 10% error. Finally, we use the rms ASD to estimate the relative error from the beatnote fluctuation measurement.
The measurement was done similar to other instances, taking the 'C1:ALS-BEATY_FINE_PHASE_OUT_HZ_DQ' timeseries (sampled at 16 kHz) and demodulating at the calibration frequencies above to get the mean YAUX laser frequency fluctuation and its uncertainty from the demodulated rms ASD.
Results
Attachment #1 shows the raw timeseries, Attachment #2 shows the spectra around the cal lines, Attachment #3 shows the demodulated timeseries, Attachment #4 shows the final result for the 5 lines, including the tallied errors as detailed above.
ITMY actuation = 4.92(11) nm / count / f^2
Discussion
We compared our results from Attachment #4 against a MICH referenced ITMY actuation calibration found here; which Yuta guess-timated a 10% uncertainty (gray shaded band in Attachment #4). An important correction came for the 575 Hz line, not just because the YAUX OLG is small but because a violin filter on ITMY LSC output has a 1.4475 gain bump. In fact we collected any additional digital gains from the ITMY output filters:
Output filter digital gains at cal lines (from foton)
30.92 Hz |
211.1 Hz |
313.31 Hz |
315.31 Hz |
575.17 Hz |
1.00007 |
1.0034 |
1.0101 |
1.01017 |
1.4475 |
Next
- Consider moving the 575 Hz line to avoid additional digital gain, but try to remain at high frequency.
- Maybe here we can use the resonant gain MOKU filters that Radhika is designing.
- Setup a live loop gain calibration to reduce the uncertainty for the high frequency cal line.
- We can also just grab GTRY (transmission) as a proxy for optical gain and use for budgeting.
- Work on setting up constraints for error mitigation based on allan deviation of the beatnote and PDH nonlinearity.
- Move this to FPMI or some other lock configuration
|
17374
|
Fri Dec 30 11:38:45 2022 |
Paco | Summary | Calibration | ALS Calibration errors -- single arm actuation | Here are my thoughts on calibration errors. This applies to the single arm actuation calibration, but may easily be extended to calibrate the DARM residual noise for example.
According to the math in this post, there are four parameters whose estimates build the total calibration uncertainty: arm length, wavelength, loop gain, and beatnote fluctuation. Below is a table for how each is measured, what the sources of statistical versus systematic error are, how large each relative contribution roughly is, and how we may improve on them.
|
Arm Length |
Wavelength |
ALS beat fluctuation |
AUX Loop gain |
Current Estimate |
FSR scan using ALS, reference to POX/POY (11 MHz) sideband. |
NPRO Specification |
DFD + Phase tracker |
Swept sine |
Statistical error |
Limited by scan range (e.g. DFD range) and resolution. |
No statistical error from specification |
Shot noise limited measurement ? |
Bendat Piersol Table 9.6 (depends on coherence) |
Systematic error |
Limited by freq reference offsets (Marconi), and residual POS-PIT coupling |
NPRO half tuning range |
Flicker noise (electronics, other) |
Swept sine bias and servo drift (thermal, flicker) |
Improvements |
More FSRs per scan at best possible resolution |
Iodine spectrsocopy |
Lower ALS residual frequency noise |
Higher AUX servo gain |
Arm length
Statistical
The arm length has been estimated before by locking the arm with the ALS beat, scanning the arm length and looking at the IR resonances. From the statistical uncertainty standpoint the limit seems to be number of measurable FSRs. Using these numbers, the statistical uncertainty comes to ~ 0.6%. Other attempts claim to have improved on this by almost an order of magnitude giving ~ 0.02%. Simply scanning over more FSRs should improve this as the usual square root number of measurements statistical error reduction.
Systematic
Systematic error comes from the frequency referenced on this measurement (the Marconi 11 MHz sideband oscillator), nonlinearities in the mostly linear scan (e.g. POS to PIT coupling). I think it's safe to neglect frequency offsets > 1 Hz because of the Rb clock reference and the Marconi's own calibration. I'm not sure about the POS to PIT coupling magnitude and whether F2A filters are helping here, but offset scan nonlinearities should distort the FSR nonuniformly and this error may have sneaked into the statistical estimate above. From the posts referenced above, the scan result seems extremely linear, but repeating the measurement and plotting the residuals may give an accurate estimate of the nonlinearity. I think either of the systematic errors discussed here should be below or around the ppm (0.0001%) level, but this should be confirmed.
Wavelength
Statistical
If we use the NPRO specification Mephisto's wavelength is 1064 nm and there is no statistical error.
If on the other hand we do iodine absorption spectroscopy, we may be able to see ~ 4 lines throughout the 30 GHz tuning range of the NPRO. Fun fact: 30 GHz correspond to 1 cm-1 (inverse centimeter). Assuming we can scan our laser with a 0.01 cm-1 resolution, it may be possible to estimate the absolute wavelength to 10 better than any line center. The ATLAS of iodine spectroscopy gives strong absorption lines around 532 nm to 0.001 cm-1, or 0.00001% accuracy. A simple Doppler broadened absorption should improve this further.
Systematic
If we use the NPRO specification the systematic error comes from the number of known significant figures ~ 0.047 %. A slightly better estimate comes from the Prometheus model with a frequency doubled output hitting near the P 83(33-0) line of iodine, at 18787.814 cm-1. This gives a nominal wavelength of 532.259 nm, or 1064.518 nm on the seed. Because the tuning range is 30 GHz, our systematic error may be +0.03 nm - 0.07 nm from 1064.52 nm. Taking the median of 0.05 nm, the relative systematic error from the Nd:YAG specification is 46.9 ppm = 0.0047%.
If on the other hand we do iodine spectroscopy, the systematic error will be dominated by the residual shifts on the iodine vapor, which are negligibly small compared to the Doppler broadened lines. They might add sub-ppm uncertainty to the absolute calibration.
Beat fluctuations
Statistical
The error in estimating beatnote fluctuations is statistically dominated if our beat detection is shot noise limited for example. Other stationary noises with power law spectra decaying faster than 1/f are subject to this effect. The allan deviation discriminates the timescales at which our measurement is dominated by statistical error. Currently our calibration lines have SNR of 10 to 100. Averaging seems to be limited to ~ 100 second timescales, so the statistical error on these measurements is ~ 0.1 to 1.0 %.
Systematic
As suggested in the above, the allan deviation discriminates the statistical dominated timescales for this measurement. There is a correspondence between noise spectra and allan deviation, so we should be able to point out what noises contribute to systematic drift in our ALS noise budget.
Loop gain
Statistical
Invoking Bendat and Piersol, Table 9.6 gives the statistical estimate of loop gain estimate with coherence gamma, and n_avg number of averages. Because of our resonant OL gain filters, assuming G ~ 100 there, and high coherence on the OLTF measurement so gamma ~ 0.9, with 12 averages we should get a relative loop gain error of 9.8%.
Systematic
Also from B&P, we should estimate how biased our TF is. This depends on delays, bandwidths, measurement device noises, etc. Furthermore, the analog electronics in the AUX servo should drift, but we neglect this contribution for now. A simple bias estimate (eq 9.75) tells us that the coherence is biased by the number of averages such that in our estimate above the unbiased coherence is roughly 0.897. This means our systematic contribution from TF bias is ~ 0.17 %.
We should remember that in the case of loop gain, the total error (systematic + statistical) gets an extra suppression factor of the order of the loop gain itself. Radhika's resonant digital gain filters should easily allocate 40 dB (or ~ 100) on every calibration line such that our total calibration error drops to the 0.1% level.
Conclusions
- The main calibration error (at the 1% level) seems to be from the ALS beat frequency. We can simply crank the SNR up, but we should work on the ALS relative stability. I think the low frequency end of the ALS residual frequency noise is currently limited by DFD... I wonder if we can improve on this by implementing a digital PLL (e.g. using a Moku)
|
17376
|
Sat Dec 31 19:27:32 2022 |
Paco | Summary | Calibration | ETMY actuation strength cal with 5 lines | Calibrated ETMY actuation strength using ALS. Attachment #1 shows the result, in close agreement with this previous measurement and a combined uncertainty estimate of 0.88%. The data was taken with 5 oscillators on, at slightly different strengths than with the ITMY run, and the actuation was on ETMY.
The ETMY actuation strength is
10.843e-9 / f^2 +- (0.88)% [m/count]
Note: gpstimes for raw data are 1356490036 to 1356495400 (a little bit over an hour and a half). |
17377
|
Sat Dec 31 20:00:03 2022 |
rana | Summary | Calibration | ETMY actuation strength cal with 5 lines |
- how much frequency dependent variation in the transfer function do we expect? Are there resonances in the mechanical suspension cage or the violin modes?
- it would be interesting to make the same TF, but from counts to coil current, and see if the variation is there. I don't expect to see much variation in the electronics, but there might be something. In principle, we can just measure the voltage at the satellite box, but the coil cable's capacitance and the coil inductance make for some wiggle. I think the resonant frequency ought to be ~ 100 kHz, but perhaps there are some wiggles due to frequency response in the AI filter or something.
|
17384
|
Wed Jan 4 12:12:57 2023 |
Paco | Summary | Calibration | ALS calibration error from DFD | [Paco, Anchal]
One of the crucial and currently limiting calibration errors is in the ALS beat. We think a major driver of calibration uncertainty may be the DFD TF calibration since it depends on the RF beat power.
The RF beat power as monitored by C1:ALS-BEATY_RF_POW shows relative fluctuations of 0.02% at the 16 Hz sampling rate (actually 0.09% rms from Attachment #1) once the single arm and YAUX laser are both locked. This sounds ok, but that's just a statistical estimate. The beat frequency changes every time we break and reacquire the lock, making the BEAT PD frequency response and DFD overall calibration change their nominal TF. This changes can be significantly larger than 0.02% (e.g 4.9% = observed change in the RF power after breaking and reacquiring the YAUX lock this morning). This is far more significant than the contribution from the RIN on the two lasers.
This kind of systematic error could be addressed by either/all:
- Stabilizing the ALS BEAT absolute frequency (offset locking using freq counter and simple integrator or equivalent)
- Rejecting RF beat amplitude fluctuations by mixing a stable DC voltage in the DFD, or using a comparator.
- Our plan this afternoon is to quickly measure the RF AM rejection level from a simple mixer and a stable voltage reference and plan ahead.
- ISS on both lasers
|
17477
|
Wed Feb 22 23:40:48 2023 |
Alex | Update | Calibration | Adding calibration constants for sus matrix and filter control buttons to the sus control screen | The callibration constants were updated for the oplev pitch and yaw. The values were changed as denoted in 17471 were:
PITH: 175.7→ 155 cts/urad
YAW: 193 → 241 cts/urad
To make these changes for the oplev callibration constants I went to ETMY - SELECTED OPLEV SERVO BOX
I then opened OLMATRIX and turned off PITCH and YAW servos in the ETMY SUSPENSION SCREEN such that the system does not attempt to actively make corrections while values are being changed.
Then I adjusted the matrix to include our updated calibration constants and reinitiated the oplev ptich and yaw servo's
This updated the calibration constants for everything

The next change that was made was the addition of the calibration filters for position, pitch, yaw and side into the sitemap view for the suspension systems.
Adding calibration filters will allow us to callibrate the pos, pitch, yaw, and side to true values of urad and umeters (see 17459)
The final screen may be seen bellow (the updated area is outlined in red):

When each of the filter buttons is clicked, the following screen will now appear (circled in yellow is the calibration constant gain we will be calculating and entering into the system):

To create the edits to the controls screen we must complete the following process
We can edit the original screen - right click > evaluate > edit this screen
Then I adjusted the width of the overall screen, and moved the right half of the modules over to the right so I could fit in some filter buttons. I then Navigated to the c1ioo wfs master screen using the open feature to copy a pre existing filter module
I then adjusted the filter module and its contents to correspond to the features and autogenerated model files from RTCDS
There was some rearranging and adjusting needed to get these files in place first. The autogenerated files from the RTCDS can be found in dir = "/opt/rtcds/caltech/c1/medm/c1sus/"
They were autogenerated with names "C1SUS_BS_PITCAL.adl", "C1SUS_BS_POSCAL.adl", "C1SUS_BS_YAWCAL.adl","C1SUS_BS_SIDECAL.adl"
We copied these files to dir = "/opt/rtcds/userapps/trunk/sus/c1/medm/templates/NEW_SUS_SCREENS/"
The file names were changed to "SUS_PITCAL.adl", "SUS_POSCAL.adl", "SUS_YAWCAL.adl", "SUS_SIDECAL.adl"
The directory we placed them in is where the models for c1 sus can be found that are referenced by the sitemap suspension monitor screen
Each file was then opened in Vscode and a few changes were made such that the specific naming values referenced by the different screens of the sitemap and different optics, are replaced by the overarching values seen in each instance of the screens.
There are approximately 50 referenced file names of "C1:SUS-BS_PITCAL" etc. In each instance we made the following changes:
"-BS" was changed to "-$(OPTIC)"
"C1:" was changed to "$(IFO):"
The new strings should read "$(IFO):SUS-$(OPTIC)_PITCAL"
Once this change was made we can now right click on the filter module box, click on "Label/Name/Args" button
In the display file, we must add the path name for the calibration directory "/opt/rtcds/userapps/trunk/sus/c1/medm/templates/NEW_SUS_SCREENS/SUS_POSCAL.adl"
And for the arguments box we will enter OPTIC=$(OPTIC), IFO=$(IFO)
You can also copy and paste the directory names in the file boxes using right click copy from the file manager and paste into the box using a single click of the mouse scroller wheel
Lastly, the PV limits were changed for each number output right click value box > PV limits > Precision > Source changed to "Default" with a value of 1.
The shown value of the position, pitch, yaw, and side was then changed to show the output from the newly added filter. This is done also by right clicking the value box and adjusting the "Readback Channel".
Value changed from "$(IFO):SUS-$(OPTIC)_TO_COIL_1_#_INMON" to the outputs from the filters which are
"$(IFO):SUS-$(OPTIC)_POSCAL_OUTMON" (for others changing POSCAL to the appropriate variable)
This is how to edit and add the Medm screens for single suspension optics into the sitemap IFO SUS screen
Lastly, Tomohiro and I worked on acquiring 6 data sets from DC stepping through adjustments in pitch and yaw for MC1, MC2 and MC3. These datasets will be fit quadratically and combined with more tests dine by AC driving the stepper motors tomorrow to find the calibration constants for the mirrors. |
17492
|
Sat Mar 4 18:57:18 2023 |
Paco | Configuration | Calibration | FPMI DARM calibration run | Locked FPMI, measured DARM and CARM OLTFs, locked YAUX and measured the analog loop TF at the cal line frequencies. Turned the cal lines on with the new filters Anchal added on MC2 (ResGain within and Notches outside the CARM bandwidth which is set to 200 Hz), and hope to get 3600 seconds of data this evening. Log and measurement data are saved under /opt/rtcds/caltech/c1/Git/40m/scripts/CAL/FPMI |
17499
|
Wed Mar 8 18:32:22 2023 |
Anchal | Configuration | Calibration | FPMI DARM calibration run set to happen at 1 am | On rossa in tmux session name FPMI_DARM_Cal, a script is running to take FPMI DARM calibration data at 1:00 am on March 9th. Please do not disturb the experiment untill 6 am. To stop the script do following on rossa:
tmux a -t FPMI_DARM_Cal
ctrl-C
The script will lock both arms, run ASS, then lock FPMI, then tune beatnote frequency with Y AUX laser to around 40 MHz, set phase tracked UGF to 2 kHz, clear phase history, take OLTF of DARM from 2 kHz to 10 Hz, take OLTF of CARM and AUX loop at calibration line frequencies, turn on the calibration lines, and wait for FPMI to unlock or 5 hours to pass, whatever happens first. At the end it will turn off the calibration lines. |
17502
|
Thu Mar 9 19:20:44 2023 |
Anchal | Configuration | Calibration | FPMI DARM calibration run set to happen at 1 am | Running this test again tonight. Will probably run it every night now.
|
17603
|
Thu May 25 14:40:03 2023 |
Paco | Update | Calibration | Measured the PSL wavelength | The PSL wavelength is 1064.5068 +- 0.0015 nm
[Paco, Yehonathan]
With yehonathan's help, we borrowed a WS6-200 wavemeter and calibrated the PSL wavelength using the frequency doubled beam at the PSL table. For this we gathered a FC/APC to FC/PC fiber, cleaned both ends, and launched ~ 6 uW of power into the wavemeter (Attachment #1 shows the setup). The vacuum wavelength was measured to be 532.2534 nm, (see picture in Attachment #2) implying a PSL wavelength of 1064.5068 nm. This is not too far from my previous estimate! The wavemeter claims a "200 MHz accuracy" so we used this as a standard error to estimate the uncertainty of 2 * 0.7 pm @ 532 nm = 1.5 pm @ 1064 nm. This leaves us with 1.4 ppm of relative wavelength error in the ALS based calibration.
- It should be noted that the Nd:YAG temperature was set to 30.615(5) degrees (?) and the injection current to 2.100 Amps for this measurement.
|
17618
|
Sat Jun 3 19:56:59 2023 |
Paco | Update | Calibration | ITMY calibration with ALS and swept line | ITMY actuator calibrated with higher resolution using ALS
Today I came briefly in the lab and restarted all models because the beams were missing in the BHD camera; implying the ASS model controlling TTs has tripped into a weird state. The problem got fixed after that and I recovered the IFO alignment more or less. Thus I began another quick calibration run --
I wrote a script to put calibration line and update the LSC YARM notch filter using python-foton so as to take an ALS calibration sweep of the YARM test mass actuator responses. For a given sweep frequency array, the script loops over the frequency, updates the notchSensMat (LSC-YARM FM10), loads the coefficients, and ramps up the SENSMAT OSC gain and frequency to inject the noise. The YAUX laser is locked to the YARM and YARM is locked to PSL during this measurement. Then, the real-time demodulated BEAT_Y signals are averaged for ~ 3 seconds (just wanted a quick scan, not a very accurate or precise one) and the result is plotted in Attachment #1. Notice that I have included the phase tracker loop correction to account for the high frequency calibration line inferred response (1 + i f/2000)
I then used foton in gui mode and exported the violin filter transfer function (FM1-4 and FM6 for ITMY) magnitude and inverted its effect to get the "dc actuation strength" of ITMY.
Discussion
- The value is consistent with our recently poor actuation due to c1sus - DAC-0 failure, at ~ 3 nm /count /f^2. I look forward to another measurement after the DAC-0 has been replaced / fixed.
- No more "high frequency" lift as seen before?
- There is still some residual frequency dependence near the phase tracker BW; maybe not just a simple integrator?
The idea of having the response shape is so I can then use the 5 lines only to get the response to high accuracy. |
17621
|
Mon Jun 5 18:42:13 2023 |
Paco | Update | Calibration | ITMY calibration with ALS and swept line | ITMY actuator calibrated with higher resolution using ALS after c1sus-DAC0 replacement
I repeated the previous measurement (with fewer points) and the result is summarized in Attachment #1 -- just as a quick confirmation that the actuation strength (POS) is restored to its nominal ~ 5 nm / ct / f^2 value.
(plot updated Tue Jun 6 10:34:27 2023 without violin filters and higher resolution) |
17624
|
Wed Jun 7 15:51:47 2023 |
Koji | Update | Calibration | ITMY calibration with ALS and swept line | Can you make this flat by compensating the gain bump due to the UGF of the phase tracker?
|
|