40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 287 of 341  Not logged in ELOG logo
    Reply  Wed Jul 20 19:24:12 2011, rana, Update, SUS, oplev gains today Untitled.pnga.png
    Reply  Sun Jul 24 20:47:21 2011, rana, Summary, Electronics, AA filter tolerance analysis 
    Reply  Mon Jul 25 00:35:44 2011, rana, Update, SUS, something wrong with ETMY LR sensor a.pngbad.png
Entry  Thu Jul 28 21:52:40 2011, rana, Update, Computers, another attempt to use pianosa 
    Reply  Sat Jul 30 02:47:43 2011, rana, Update, PSL, ABSL Laser crystal temp left largely excited & left unattended for more than 3hours 
    Reply  Sat Jul 30 20:41:50 2011, rana, Update, PSL, RefCav Stabilization back on Untitled.png
    Reply  Mon Aug 1 11:46:56 2011, rana, Summary, LSC, Tolerance of Arm length = 2 cm 
    Reply  Tue Aug 2 16:55:21 2011, rana, Update, ABSL, Arm length measurement : cavity kick technique L.png
    Reply  Thu Aug 4 11:18:12 2011, rana, Update, SUS, sus at atm 
    Reply  Sat Aug 6 13:38:02 2011, rana, Summary, General, Summary of today's in-vacuum work 
    Reply  Mon Aug 8 00:12:58 2011, rana, Update, CDS, diagonalization of MC input matrix 
    Reply  Mon Aug 8 00:58:26 2011, rana, Update, CDS, diagonalization of MC input matrix null.png
    Reply  Mon Aug 8 12:08:05 2011, rana, Update, SUS, sus at atm Untitled.png
    Reply  Wed Aug 10 14:35:39 2011, rana, Update, PEM, Calibration of Guralp and STS2 
Entry  Wed Aug 10 22:47:22 2011, rana, Summary, VAC, Vacuum Workstation (linux3) re-activated 
    Reply  Sat Aug 27 15:47:59 2011, rana, Update, CDS, OSEM noise / nullstream and what does it mean for satellites Untitled.png
Entry  Tue Sep 6 22:51:53 2011, rana, Summary, Cameras, All Camera setups a need upgrading 
Entry  Wed Sep 7 00:39:34 2011, rana, Update, SUS, ITMX adjustments 
    Reply  Wed Sep 7 22:17:04 2011, rana, Update, IOO, RF Amp for EOM on PSL Table 
    Reply  Fri Sep 9 19:15:17 2011, rana, Update, IOO, RF Amp for EOM on PSL Table 
Entry  Sat Sep 10 11:07:37 2011, rana, HowTo, SUS, Optical Lever Servo Tuning thoughts 
Entry  Sat Sep 10 18:52:45 2011, rana, Update, Computers, conlog getting filled up 
Entry  Sat Sep 10 19:03:57 2011, rana, Update, LSC, Y Arm work 
Entry  Sat Sep 10 20:30:01 2011, rana, Update, IOO, MC trans re-aligned / MC2 shifted mysteriously / MC2 re-aligned MCdecenter.png
    Reply  Wed Sep 14 12:01:05 2011, rana, Update, Adaptive Filtering, Modifications to LSC, RFM models, added OAF model 
Entry  Wed Sep 14 20:30:36 2011, rana, Update, SUS, Some screens are still bad Untitled.png
Entry  Wed Sep 14 22:07:41 2011, rana, Update, SUS, ITM Oplevs are broken mm.jpg
    Reply  Sun Sep 18 14:08:52 2011, rana, Update, SUS, Calibration plan for the oplevs 
    Reply  Mon Sep 19 17:45:39 2011, rana, Update, SUS, Some screens fixed Untitled.png
    Reply  Mon Sep 19 18:05:27 2011, rana, Update, SUS, Summary screen sussum.png
    Reply  Wed Sep 21 00:34:29 2011, rana, Update, SUS, SUS diag stuff... just so I remember what I'm doing 
    Reply  Wed Sep 21 00:37:01 2011, rana, Update, SUS, ITMY and SRM oplev calibrations - measured and estimated 
    Reply  Wed Sep 21 16:22:14 2011, rana, Update, SUS, Summary screen 
    Reply  Wed Sep 21 17:42:35 2011, rana, Update, IOO, AM modulation misery 
    Reply  Wed Sep 21 21:13:35 2011, rana, Update, IOO, AM modulation misery 
    Reply  Sat Sep 24 01:51:02 2011, rana, Update, SUS, Oplev filter optimization for 2 poles and 2 zeros 
    Reply  Sun Oct 2 13:45:13 2011, rana, Summary, General, Recovery from the power shutdown: apache / svn 
    Reply  Mon Oct 10 10:14:43 2011, rana, Update, LSC, length fluctuations in SRCL 
    Reply  Tue Oct 11 15:14:50 2011, rana, Update, LSC, BS actuator reponse at low frequency : measured 
Entry  Tue Oct 11 15:19:17 2011, rana, HowTo, Environment, 40m map 40mLabMap.png40mLabMap.jpg
    Reply  Thu Oct 13 21:40:59 2011, rana, Summary, VAC, Recovery from the power shutdown is completed 
    Reply  Sat Oct 15 10:58:32 2011, rana, Update, IOO, MC WFS Output Matrix determination 
    Reply  Sun Oct 16 02:30:00 2011, rana, Update, Electronics, Testing REFL165  
    Reply  Sun Oct 16 05:35:18 2011, rana, Update, Computer Scripts / Programs, Failing to set SUS summary screen values 
Entry  Mon Oct 17 23:28:32 2011, rana, Update, Electronics, StochMon 
Entry  Tue Oct 18 21:19:18 2011, rana, Configuration, IOO, WFS disabled in SUS 
Entry  Fri Oct 28 00:53:39 2011, rana, Update, Electronics, POP 22/110 Design poy22110.pdf
    Reply  Sun Oct 30 14:08:35 2011, rana, Update, Electronics, RFAM monitor in place. ( Uncalibrated ) EPICS troubles 
    Reply  Fri Nov 4 19:30:06 2011, rana, Update, SUS, Dr. SUS paths updated--question of human oversight remains 
    Reply  Sun Nov 6 21:09:03 2011, rana, Update, Adaptive Filtering, coherence 