ID |
Date |
Author |
Type |
Category |
Subject |
2546
|
Mon Jan 25 16:46:33 2010 |
Alberto | Update | ABSL | 166 MHz sideband turned off |
Quote: |
I turned off the modulation at 166MHZ becasue I don't need it if I'm only locking the PRC.
It was introducing extra amplitude modulations of the beam which interfered with the AbsL's PLL photodiode.
I'm going to turn it back on later on.
|
I turned back on the 166MHz modulation just a bit. I set the slider at 4.156.
When it was totally off the MZ seemd quite unhappy. |
2545
|
Mon Jan 25 16:30:37 2010 |
Alberto | Update | ABSL | 166 MHz sideband turned off | I turned off the modulation at 166MHZ becasue I don't need it if I'm only locking the PRC.
It was introducing extra amplitude modulations of the beam which interfered with the AbsL's PLL photodiode.
I'm going to turn it back on later on. |
2544
|
Mon Jan 25 11:42:24 2010 |
josephb | Update | Computers | Megatron and BO board | I was talking with Vladimir on Friday discussing the Binary Output board, we looked at the manual for it (Contec DO-32L-PE) and we realized its an opto-coupler isolated open-collector output. He mentioned they had the right kind of 50 channel breakout board for testing in Riccardo's lab.
This morning I borrowed the 50 channel breakout board from Riccardo's lab, and along with some resistor loads, test the BO board. It seems to be working, and I can control the output channel on/off state. |
2543
|
Fri Jan 22 14:40:49 2010 |
Alberto | Update | ABSL | Overnight measurement |
Quote: |
I'm leaving a measurement running overnight. It should be done in about one hour.
Tomorrow morning, If you need to use the interferometer, and you don't want to have the auxiliary beam going onto the dark port, you can turn down the flipping mirror and close the NPRO's mechanical shutter.
|
This is what I measured last night:

This is not a fit. It's just a comparison of the model with the data. |
2542
|
Fri Jan 22 12:33:37 2010 |
josephb, alex | Update | Computers | Modified CDS_PARTS for Binary output | Turns out the CDSO32 part (representing the Contec BO-32L-PE binary output) rquires two inputs. One for the first 16 bits, and one for the second set of 16 bits. So Alex added another input to the part in the library. Its still a bit strange, as it seems the In1 represents the second set of 16 bits, and the In2 represents the first set of 16 bits.
I added two sliders on the CustomAdls/C1TST_ETMY.adl control screen (upper left), along with a bit readout display, which shows the bitwise and of the two slider channels. For the moment, I still can't see any output voltage on any of the DO pins, no matter what output I set.
|
2541
|
Fri Jan 22 02:54:06 2010 |
Alberto | Update | ABSL | Overnight measurement | I'm leaving a measurement running overnight. It should be done in about one hour.
Tomorrow morning, If you need to use the interferometer, and you don't want to have the auxiliary beam going onto the dark port, you can turn down the flipping mirror and close the NPRO's mechanical shutter. |
2540
|
Thu Jan 21 17:23:30 2010 |
josephb,alex,koji | HowTo | Computers | RCG code fixes | In order to see the Contec DO-32L-PE Digital output PCIe card with the new controls, we had to add the CDO32 part to the CDS_PARTS.mdl file in control /cds/advLigo/src/epics/simLink/ directory on megatron, as well as create the actual model mdl file (based on cdsDio.mdl ) in the control/cds/advLigo/src/epics/simLink/lib directory.
The CDO32.pm file (in /home/controls/cds/advLigo/src/epics/util/lib ) has existed for some time, it was just missing the associated pieces in simlink. However, Alex also checked out a newer version Dio.pm in the process. As we are not using this part at this time, it should be fine.
The code now compiles and sees the digital output card.
You need a special care on this block as it turned out that the code does not compiled if the "constant" block is connected to the input. You must use appropriate block such as bitwise operator, as shown below. |
Attachment 1: CDO32.png
|
|
2539
|
Thu Jan 21 15:16:16 2010 |
josephb, koji | Summary | Computers | Megatron used to lock Y arm | We succeeded in having a stable single arm (Y) lock using Megatron to replace c1iscey.
Now the lock with megatron is pretty easy. Really. It's very cool.
As we saw the oscillation of the YARM servo, we temporalily increased the gain of TRY filter by a factor of 2 (0.003->0.006). Also decreased the gain of YARM servo by the factor of 2 (1->0.5). This makes the servo gain reduced by a factor of 4 in total. This change seemed to come from the change of the ADC/DAC range.
We finally fixed the hi-gain pd transmission communications from Megatron to the c1lsc by tracking down the correct RFM memory location (which is unhelpfully labeled as a qpd channel in both losLinux and lsc40.m). The memory location is 0x11a1e0, and is refered to as qpdData[3]. |
2538
|
Thu Jan 21 11:08:30 2010 |
kiwamu, steve | Update | VAC | Dry Pump replacement | This morning I and Steve replaced the dry fore pump of TP3, which is located under the y-arm.
After replacing it we confirmed vacuum normal condition. The fore line pressure of TP3 went down to 11 mTorr from 750 mTorr
Attached picture is new pump after setup. |
Attachment 1: DSCN0428.JPG
|
|
2536
|
Thu Jan 21 10:31:13 2010 |
Koji | Update | ABSL | Some preliminary results from measuring PRC's transmissivity for an amplitude modulated beam | Nice and interesting plot.
I suppose slight decrease of the Schnupp asymmetry (in your model) adjusts the discrepancy in the high freq region.
At the same time, it will make the resonance narrower. So you need to put some loss at the recombination (=on the BS)?
...of course these depends on the flatness of the calibration. |
2535
|
Thu Jan 21 10:09:27 2010 |
Koji | Summary | IOO | Photos of the optical tables | I made a wiki page dedicated for the photos of the optical tables.
The current layouts were uploaded.
http://lhocds.ligo-wa.caltech.edu:8000/40m/Optical_Tables |
2534
|
Wed Jan 20 20:11:56 2010 |
Alberto | Update | ABSL | Some preliminary results from measuring PRC's transmissivity for an amplitude modulated beam | Here I'm posting a plot showing a set of measurements that I made in the past few days to determine the absolute length of the PRC cavity.
As in my other AbsL measurements, I inject an auxiliary laser beam into the cavity and look at the transmission. In the PRC case, the beam is injected through the dark port and I look at a pick-off of the REFL beam. The aux laser is phase locked to the PSL beam and I control the differential frequency between the two. The PSL and the aux beam interfere and beat at their differential frequency.
The attached plot shows the transmitted power as a function of the beat frequency.
Fitting the data with the model would let me determine the cavity length.
By now I can estimate the length of the PRC at about 2.257m, but it's still a rather approximate value.
I can't provide accurate error bars yet. I need to optimize the measurements to get a more precise value.
I will go more through the details of the measurement technique and of the fitting function as soon as I have more definitive results.
The data points shown here were taken at different times and not always in optimal alignment condition of the PRC.
To get a good fit of the data I should have fewer frequency segments, taken in a shorter period of time, and in which the power circulating inside of the cavity (ie SPOB) fluctuates as little as possible.
For what regards the time needed for a measurements, I already significantly sped up the measurements (i.e. optimizing the scanning and acquisition GPIB scripts, and fixing a couple of problems with the PDH box used in the PLL), and finally now I can scan several tens of MHz in few minutes.
About the frequency segments, so far they have been determined by two factors
1) Tthe frequency generator in the PLL: the Marconi works as a continuous wave generator only in limited ranges. Switching from one to another brakes the wave in a way that causes the PLL to lose lock.
2) Getting below 18 MHz a series of other beats appear on the PLL photodiode and make the PLL lose lock.
For the first problem, I'm thinking of using two Marconis and to mix their signals. I would keep one at 300MHz and I would scan the other from 300MHz to 500MHz. In fat, in that frequency range the Marconi has not discontinuity.
To try to avoid the other beats at low frequency, I'm not entirely sure about what to do yet.
To be continued... |
Attachment 1: 2010-01-19_PRCtransmissivityVsModel.png
|
|
2533
|
Tue Jan 19 23:26:07 2010 |
kiwamu | Update | Electronics | Re:Re: triple resonant circuit for EOM |
Quote: |
5. For the impedance matching, I will select a transformer so that 55MHz is matched. In contrast I will leave two lower resonances as they are.
This is because 11MHz and 29.5MHz usually tend to have higher impedance than 55MHz. In this case, even if the impedance is mismatched, the gain for these can be kept higher than 11.
I will post the detail for this mismatched case tomorrow.
|
Here the technique of the impedance matching for the triple resonant circuit are explained.
In our case, the transformer should be chosen so that the impedance of the resonance at 55MHz is matched.
We are going to use the transformer to step up the voltage applied onto the EOM.
To obtain the maximum step-up-gain, it is better to think about the behavior of the transformer.
When using the transformer there are two different cases practically. And each case requires different optimization technique. This is the key point.
By considering these two cases, we can finally select the most appropriate transformer and obtain the maximum gain.
( how to maximize the gain ?)
Let us consider about the transformer. The gain of the circuit by using the transformer is represented by
(1)
Where ZL is the impedance of the load (i.e. impedance of the circuit without the transformer ) and n is the turn ratio.
It is apparent that G is the function of two parameters, ZL and n. This leads to two different solutions for maximizing the gain practically.

- case.1 : The turn ratio n is fixed.
In this case, the tunable parameter is the impedance ZL. The gain as a function of ZL is shown in the left figure above.
In order to maximize the gain, Z must be as high as possible. The gain G get close to 2n when the impedance ZL goes to infinity.
There also is another important thing; If the impedance ZL is bigger than the matched impedance (i.e. ZL = 50 * n^2 ), the gain can get higher than n.
- case.2 : The impedance ZL is fixed.
In contrast to case1, once the impedance ZL is fixed, the tunable parameter is n. The gain as a function of n is shown in the right figure above.
In this case the impedance matched condition is the best solution, where ZL=50*n^2. ( indicated as red arrow in the figure )
The gain can not go higher than n somehow. This is clearly different from case1.
( Application to the triple resonant circuit )
Here we can define the goal as "all three resonances have gain of more than n, while n is set to be as high as possible"
According to consideration of case1, if each resonance has an impedance of greater than 50*n^2 (matched condition) it looks fine, but not enough in fact.
For example if we choose n=2, it corresponds to the matched impedance of 50*n^2 = 200 Ohm. Typically every three resonance has several kOhm which is clearly bigger than the matched impedance successfully.
However no matter how big impedance we try to make, the gains can not be greater than G=2n=4 for all the three resonance. This is ridiculous.
What we have to do is to choose n so that it matches the impedance of the resonance which has the smallest impedance.
In our case, usually the resonance at 55MHz tends to have the smallest impedance in those three. According to this if we choose n correctly, the other two is mismatched.
However they can still have the gain of more than n, because their impedance is bigger than the matching impedance. This can be easily understand by recalling the case1.
(expected optimum gain of designed circuit)
By using the equation (1), the expected gain of the triple resonant circuit including the losses is calculated. The parameters can be found in last entry.

The turn ratio is set as n=11, which matches the impedance of the resonance at 55MHz. Therefore 55MHz has the gain of 11.
The gain at 11MHz is bigger than n=11, this corresponds to the case1. Thus the impedance at 11MHz can go close to gain of 22, if we can make the impedance much big.
|
2532
|
Tue Jan 19 16:21:18 2010 |
Alberto | Update | ABSL | Watchdogs not working and then fixed | This afternoon the watchdogs stopped working: they didn't trip when the suspension positions crossed the threshold values.
I rebooted c1susaux (aka c1dscl1epics0 in the 1Y5 rack), which is the computer that runs the watchdog processes.
The reboot fixed the problem. |
2531
|
Tue Jan 19 12:54:39 2010 |
Alberto | Update | ABSL | Measurement in progress | A measurement will be running for the next hour. Please be careful. |
2530
|
Tue Jan 19 10:30:29 2010 |
josephb | Update | Computers | Boot fest to restart the computer and c1iscey not responding. |
Quote: |
Thi afternoon I found that the RFM network in trouble. The frontends sync counters had railed to 16384 counts and some of the computers were not responding. I went for a bootfest, but before I rebooted c1dcu epics. I did it twice. Eventually it worked and I could get the frontends back to green.
Although trying to burtrestore to snapshots taken at any time after last wednesday till today would make the RFM crash again. Weird.
Also, c1iscey seems in a coma and doesn't want to come back. Power cycling it didn't work. I don't know how to be more persuasive with it.
|
During the testing of Megatron as the controller for ETMY, c1iscey had been disconnected from the ethernet hub. Apparently we forgot to reconnect it after the test. This prevented it from mounting the nfs directory from linux1, and thus prevented it from coming up after being shutdown. It has been reconnected, restarted, and is working properly now. |
2529
|
Tue Jan 19 03:27:47 2010 |
kiwamu | Update | Electronics | Re: triple resonant circuit for EOM | 1. You are right, the gain for the single resonant circuit was about 9.3 in my measurement.
But the reason why the triple is better than the single resonant circuit comes from the transformer.
The impedance can be degraded by a loss of the transformer, because it got worse after applying the transformer in the past measurement.
Also I definitely confirmed that the circuit had the impedance of 7.2 kOhm at the resonance of 52.9MHz without the transformer.
So it shall give the gain of 12, but did not after applying the transformer.
2. Yes, I think we need some variable components just in case.
5. For the impedance matching, I will select a transformer so that 55MHz is matched. In contrast I will leave two lower resonances as they are.
This is because 11MHz and 29.5MHz usually tend to have higher impedance than 55MHz. In this case, even if the impedance is mismatched, the gain for these can be kept higher than 11.
I will post the detail for this mismatched case tomorrow.
Quote: |
The design looks very good. I have some questions.
1. As far as I remember, you've got the gain of slightly worse than 10 for a 55MHz single resonant case. Why your expectation of the gain (G=11) for the highest resonance better than this?
Supposing the loss exists only on the EOM, the other part of the LC network for the triple work as an inductor at the resonant frequency. This is just equivalent as the single resonant case. So the expected gain at 55MHz should coincides with what we already have. Probably, the resistance of 4 Ohm that is used here had too rough precision???
2. How can you adjust the resonances precisely?
Do we need any variable components for Cs and Ls, that may have worse quality than the fixed one, generally speaking.
I myself has no experience that I had to tune the commercial EOM because of a drift or whatever. I hope if you can adjust the resonance with a fixed component it should be fine.
3. Changing Cp. What does it mean?
Do you put additional cap for Cp?
4. The resonances for the lower two look very narrow. Is that fine?
This will show up in a better shape if we look at the transfer function for the gain. Is this right?
If we have BW>100kHz, it is sufficient.
5. Impedance matching for the lower two resonances.
Yep. You know this problem already.
|
|
2528
|
Tue Jan 19 03:20:28 2010 |
Koji | Update | Electronics | design complete --- triple resonant circuit for EOM --- | First I was confused, but now I think I understood.
My confusion:
If the k get bigger, L get smaller, C get bigger. This makes R(L) smaller and R(C) smaller. This sounds very nice. But why smaller k is preferable in the Kiwamu's result?
Explanation:
The resultant impedance of the network at a resonance is determined by Zres = L/(R C) or something like that. Here R = R(L)+R(C). (I hope this is right.)
Here larger Zres is preferable. So smaller R is nice.
But If the speed of reduction for R is slower than that of L/C (which is proportional to k^-2), increasing k does not help us to increase of Zres. And that's the case.
This means "if we can put the LC network in the box of EOM, we can do better job!" as we can reduce Cp.
Quote: |

Loss for Capacitor : R(C) = 0.5 (C / 10pF)^{-0.3} Ohm
Loss for Inductor : R(L) = 0.1 ( L / 1uH) Ohm
|
|
2527
|
Tue Jan 19 03:04:14 2010 |
Koji | Update | Electronics | triple resonant circuit for EOM | Self-follow:
I got the answer of Q3 from the follow-up entry.
For Q4, once you get the impedance of the LC network lower than n^2*50, the EOM gain will be quite low. This means that the resonance is anyway narrow.
I did some simple calculation and it shows that the width of the resonance will be 100kHz~500kHz. So it maybe OK.
Quote: |
The design looks very good. I have some questions.
1. As far as I remember, you've got the gain of slightly worse than 10 for a 55MHz single resonant case. Why your expectation of the gain (G=11) for the highest resonance better than this?
Supposing the loss exists only on the EOM, the other part of the LC network for the triple work as an inductor at the resonant frequency. This is just equivalent as the single resonant case. So the expected gain at 55MHz should coincides with what we already have. Probably, the resistance of 4 Ohm that is used here had too rough precision???
2. How can you adjust the resonances precisely?
Do we need any variable components for Cs and Ls, that may have worse quality than the fixed one, generally speaking.
I myself has no experience that I had to tune the commercial EOM because of a drift or whatever. I hope if you can adjust the resonance with a fixed component it should be fine.
3. Changing Cp. What does it mean?
Do you put additional cap for Cp?
4. The resonances for the lower two look very narrow. Is that fine?
This will show up in a better shape if we look at the transfer function for the gain. Is this right?
If we have BW>100kHz, it is sufficient.
5. Impedance matching for the lower two resonances.
Yep. You know this problem already.
|
|
2526
|
Tue Jan 19 02:40:38 2010 |
Koji | Update | Electronics | triple resonant circuit for EOM | The design looks very good. I have some questions.
1. As far as I remember, you've got the gain of slightly worse than 10 for a 55MHz single resonant case. Why your expectation of the gain (G=11) for the highest resonance better than this?
Supposing the loss exists only on the EOM, the other part of the LC network for the triple work as an inductor at the resonant frequency. This is just equivalent as the single resonant case. So the expected gain at 55MHz should coincides with what we already have. Probably, the resistance of 4 Ohm that is used here had too rough precision???
2. How can you adjust the resonances precisely?
Do we need any variable components for Cs and Ls, that may have worse quality than the fixed one, generally speaking.
I myself has no experience that I had to tune the commercial EOM because of a drift or whatever. I hope if you can adjust the resonance with a fixed component it should be fine.
3. Changing Cp. What does it mean?
Do you put additional cap for Cp?
4. The resonances for the lower two look very narrow. Is that fine?
This will show up in a better shape if we look at the transfer function for the gain. Is this right?
If we have BW>100kHz, it is sufficient.
5. Impedance matching for the lower two resonances.
Yep. You know this problem already.
|
2525
|
Tue Jan 19 02:39:57 2010 |
kiwamu | Update | Electronics | design complete --- triple resonant circuit for EOM --- | The design of the triple resonant circuit has been fixed.
I found the optimum configuration, whose gain is still 11 at 55MHz even if there are realistic losses.
As I mentioned in the last entry, there are infinite number of the similar solutions to create the same resonant frequencies.
However owing to the effect of the losses, the resultant gain varies if the similar solution changes
The aim of this study is to select the optimum solution which has a maximum gain ( = the highest impedance at the resonance ).
In order to handle the losses in the calculation, I modeled the loss for both inductors and the capacitors.
Then I put them into the circuit, and calculated the impedance while changing the solutions.
(method)
1). put the scaling parameter as k in order to create the similar solution.
2). scale the all electrical parameters (L1, L2,...) by using k, so that C1'=C1 x k, L1'=L1/k ,...
3). Insert the losses into all the electrical components
4). Draw the impedance curve in frequency domain.
5). See how the height of the impedance at the resonance change
6). Repeat many time this procedure with another k.
7). Find and select the optimum k

There is a trick in the calculation.
I put a capacitor named Cpp in parallel to the EOM in order to scale the capacitance of the EOM (see the schematic).
For example if we choose k=2, this means all the capacitor has to be 2-times larger.
For the EOM, we have to put Cpp with the same capacitance as Cp (EOM). As a result these two capacitors can be dealt together as 2 x Cp.
So that Cpp should be Cpp = (k-1) Cp, and Cpp vanishes when we choose k=1.
The important point is that the scaling parameter k must be greater than unity, that is k > 1.
This restriction directly comes from Cp, the capacitance of the EOM, because we can not go to less than Cp.
If you want to put k < 1, it means you have to reduce the capacitance of the EOM somehow (like cutting the EO crystal ??)
(loss model)
I've modeled the loss for both the inductors and the capacitors in order to calculate the realistic impedance.
The model is based on the past measurements I've performed and the data sheet.
Loss for Capacitor : R(C) = 0.5 (C / 10pF)^{-0.3} Ohm
Loss for Inductor : R(L) = 0.1 ( L / 1uH) Ohm
Of course this seems to be dirty and rough treatment.
But I think it's enough to express the tendency that the loss increase / decrease monotonically as L / C get increased.
These losses are inserted in series to every electrical components.
( Note that: this model depends on both the company and the product model. Here I assume use of Coilcraft inductors and mica capacitors scattered around 40m )
( results )
The optimum configuration is found when k=1, there is no scaling. This is the same configuration listed in last entry
Therefore we don't need to insert the parallel capacitor Cpp in order to achieve the optimum gain.
The figure below shows the some examples of the calculated impedance. You can see the peak height decrease by increasing the scale factor k.

The black dash line represents the EOM-loss limit, which only contains the loss of the EOM.
The impedance at the resonance of 55MHz is 6.2 kOhm, which decreased by 3% from the EOM-loss limit. This corresponds to gain of G = 11.
The other two peaks, 11MHz and 29.5MHz dramatically get decreased from EOM-loss limit.
I guess this is because the structure below 50MHz is mainly composed by L1, L2, C1, C2.
In fact these components have big inductance and small capacitance, so that it makes lossy.
( next step )
The next step is to choose the appropriate transformer and to solder the circuit. |
2524
|
Tue Jan 19 00:10:44 2010 |
rana | Update | Electronics | triple resonant circuit for EOM | Very cool.  |
2523
|
Mon Jan 18 23:44:19 2010 |
kiwamu | Update | Electronics | triple resonant circuit for EOM | The first design of the triple resonant EOM circuit has been done.
If only EOM has a loss of 4 Ohm, the gain of the circuit is expected to be 11 at 55MHz 
So far I've worked on investigation of the single resonant circuit and accumulated the knowledge about resonant circuits.
Then I started the next step, designing the triple resonant circuit.
Here I report the first design of the circuit and the expected gain.
( What I did )
At first in order to determine the parameters, such as inductors and capacitors, I have solved some equations with numerical ways (see the past entry).
In the calculation I put 6 boundary conditions as followers;
(first peak=11MHz, second peak=29.5MHz, third peak=55MHz, first valley=22MHz, second valley=33MHz, Cp=18pF)
The valley frequencies of 22MHz and 33MHz are chosen in order to eliminate the higher harmonics of 11MHz, and Cp of 18pF represents the capacitance of the EOM.
Basically the number of parameters to be determined is 6 ( L1, L2, ...,), therefore it is completely solved under 6 boundary conditions. And in this case, only one solution exists.
The point is calculation does not include losses because the loss does not change the resonant frequency.

( results )
As a result I obtained the 6 parameters for each components shown in the table below.
Cp [pF] |
18.1 |
C1 [pF] |
45.5 |
C2 [pF] |
10.0 |
Lp [uH] |
2.33 |
L1 [uH] |
1.15 |
L2 [uH] |
2.33 |
Then I inserted the loss into the EOM to see how the impedance looks like. The loss is 4 Ohm and inserted in series to the EOM. This number is based on the past measurement .
Let us recall that the gain of the impedance-matched circuit with a transformer is proportional to square-root of the peak impedance.
It is represented by G = sqrt(Zres/50) where Zres is the impedance at the resonance.
As you can see in the figure, Zres = 6.4 kOhm at 55MHz, therefore the gain will be G=11 at 55MHz.
Essentially this gain is the same as that of the single resonant circuit that I've been worked with, because its performance was also limited mainly by the EOM loss.
An interesting thing is that all three peaks are exactly on the EOM limited line (black dash line), which is represented by Zres = L/CR = 1/ (2pi f Cp)^2 R. Where R = 4 Ohm.

( next plan )
There are other solutions to create the same peaks and valleys because of the similar solution.
It is easy to understand if you put Cp' = Cp x N, the solutions must be scaled like L1'=L1/N, C1'=C1 x N, ..., Finally such scaling gives the same resonant frequencies.
So the next plan is to study the effect of losses in each components while changing the similar solution.
After the study of the loss I will select an optimum similar solution. |
2522
|
Mon Jan 18 20:58:40 2010 |
Alberto | Update | ABSL | Measurement in progress |
Quote: |
I started a long measurement of the PRC's transmissivity. I'm leaving the lab and I'm going to be back at about 8 tonight. Please do not disturb the interferometer. it is important that the MC and the PRC stay locked all the time.
|
That measurement is finished. I'm now going to start another one that will take another hour or so. I'm leaving it running for the night. If you want to work on the IFO, it should be definitely done by 11pm. |
2521
|
Mon Jan 18 18:34:01 2010 |
Alberto | Update | ABSL | Measurement in progress | I started a long measurement of the PRC's transmissivity. I'm leaving the lab and I'm going to be back at about 8 tonight. Please do not disturb the interferometer. it is important that the MC and the PRC stay locked all the time. |
2520
|
Mon Jan 18 09:44:36 2010 |
Alberto, Bob | Omnistructure | Environment | No rain water infiltrations so far | It has rained continuously for the last 24 hours. Bob walked through the lab looking for possible water infiltrations. The floor looked dry: no puddles or leaks anywhere so far. |
2519
|
Sun Jan 17 19:18:55 2010 |
Alberto | Update | Computers | Boot fest to restart the computer and c1iscey not responding. | Thi afternoon I found that the RFM network in trouble. The frontends sync counters had railed to 16384 counts and some of the computers were not responding. I went for a bootfest, but before I rebooted c1dcu epics. I did it twice. Eventually it worked and I could get the frontends back to green.
Although trying to burtrestore to snapshots taken at any time after last wednesday till today would make the RFM crash again. Weird.
Also, c1iscey seems in a coma and doesn't want to come back. Power cycling it didn't work. I don't know how to be more persuasive with it. |
2518
|
Sun Jan 17 05:22:42 2010 |
rana | Configuration | Computers | ELOG script change | With Dave Barker's help, I changed the elog startup script. Instead of running as a Daemon with the -D option,
it now runs in the background with the unix "&". I think that the stdout and stderr are now redirected to a log file called elog.log.
We can 'tail -f' this file to see what its up to and debug any future crashing. |
2517
|
Fri Jan 15 18:53:05 2010 |
josephb,peter,koji | Update | Computers | Attempted locking with Megatron replacing ETMY front end | This afternoon we attempted to lock the interferometer using Megatron insteady of the usual ETMY front end.
We attempted it once, found the alignment seemed particularly bad, then realized we had forgotten to add the QPDs. In the process of adding the QPDs to the tst.mdl file, we realized I (Joe) should have been looking at the iscNetDsc.h file, not the iscNetDs40m.h file for the RFM memory structure. The only major difference was the memory location of where the qpd information gets passed.
We added QPDs to the tst.mdl file, writing to the RFM network with the QPD pitch, yaw and sum values.
We also added normalization to the oplev, by dividing the OL pitch and yaw values by the OL sum value in the tst.mdl file.
The lscPos, ascPit, ascYaw were working properly, although we did have to poke at the ascPit and ascYaw values once before they started reading properly at Megatron (they started at -1e20). We think the RFM card may have started in an odd state, and without something causing the ascPit and ascYaw values to change, it never updated.
At the end of the day, the interferometer was locked for a few seconds. There is are still some issues to be worked on, but its progress.
Koji returned everything back to normal operations after the test. |
2516
|
Fri Jan 15 12:04:26 2010 |
Sanjit, mevans | Update | Adaptive Filtering | Canceling noise again! |
OAF is successfully canceling noise again, thanks to Matt!
Here is a plot showing more than a factor of 10 noise reduction around 3Hz (similar to what we saw in the simulations)
The changes that has made it work are:
- use of RANGER channel (with ACC_MC1_X and/or ACC_MC2_X)
- mu = 0.01, tau = 1.0e-6, ntaps = 2000, nDown = 16
- nDelay = 5 and nDelay = 7 both work (may not be so sensitive on delay at low frequencies)
- Main changes: filter bank on the PEM channels (ASS_TOP_PEM_## filters: 0.1:0, 1:, Notch24, AA32)
- Added the AI800 filter for upsampling in MC1 (should not matter)
Matt suggested playing with the emphasis (EMPH) filters to cancel noise in different frequency bands.
|
Attachment 1: OAF_15JAN2010.png
|
|
2515
|
Fri Jan 15 11:21:05 2010 |
josephb | Update | Computers | Megatron and tst model for ETMY | The tst model wasn't compiling this morning due to some incorrect lines in the RfmIOfloat.pm file located in /home/controls/cds/advLIgo/src/epics/util/lib file on megatron.
The error was "Undefined subroutine &CDS::RfmIOfloat::partType called at lib/Parser2.pm line 354, <IN> line 3363."
I changed RfmIO to RfmIOfloat on lines 1 and 6.
Basically the first 6 lines are now
package CDS::RfmIOfloat;
use Exporter;
@ISA = ('Exporter');
sub partType {
return RfmIOfloat;
}
The tst now compiles. At the moment, I believe we should be able to switch megatron in for ETMY and attempt to lock the arm. The whitening/dewhitening filters are still not automatically synced in software and hardware, but I don't think that should prevent locking. |
2514
|
Thu Jan 14 11:44:06 2010 |
josephb | Summary | Computers | Memory locations for TST model for ITMY | The main communications data structure is RFM_FE_COMMS, from the rts/src/include/iscNetDsc40m.h file. The following comments regard sub-structures inside it. I'm looking at all the files in /rts/src/fe/40m to determine how the structures are used, or if they seem to be unnecessary.
The dsccompad structure is used in the lscextra.c file. I am assuming I don't need to add anything fo the model for these. They cover from 0x00000040 to 0x00001000.
FE_COMMS_DATA is used twice, once for dataESX (0x00001000 to 0x00002000), and once for dataESY (0x00002000 to 0x00003000).
Inside FE_COMMS_DATA we have:
status and cycle which look to be initialized then never changed (although they are compared to).
ascETMoutput[P,Y], ascQPDinput are all set to 0 then never used.
qpdGain is used, and set by asc40m, but not read by anything. It is offset 114, so in dataESX its 4210 (0x00001072), and in dataESY its (0x00002072)
All the other parts of this substructure seem to be unused.
daqTest, dgsSet, low1megpad,mscomms seem unused.
dscPad is referenced, but doesn't seem to be set.
pCoilDriver is a structure of type ALL_CD_INFO, inside a union called suscomms, inside FE_COMMS_Data, and is used. In this structure, we have:
extData[16], an array of DSC_CD_PPY structures, which is used. Inside extData we have for each optic (ETMY has an offset of 9 inside the extData array):
Pos is set in sos40m.c via the line pRfm->suscomms.pCoilDriver.extData[jj].Pos = dsp[jj].data[FLT_SUSPos].filterInput; Elsewhere, Pos seems to be set to 1.0
Similarly, Pit and Yaw are set in sos40m, except with FLT_SUSPitch and FLT_SUSYaw, and being set elsewhere to 1.1, 1.2. However, these are never applied to the ETMX and ETMY optics (it goes through offests 0 through 7 inclusive).
Side is set 1.3 or 1.0 only, not used.
ascPit , ascYaw, lscPos are read by the losLinux.c code, and is updated by the sos40m.c code. For ETMY, their respective addresses are: 0x11a1c0, 0x11a1c4, 0x11a1c8.
lscTpNum, lscExNum, seem to be initialized, and read by the losLinux.c, and set by sos40m.c.
modeSwitch is read, but looks to be used for turning dewhitening on and off. Similarly dewhiteSW1R is read and used.
This ends the DSC_CD_PPY structure.
lscCycle, which is used, although it seems to be an internal check.
dum is unused.
losOpLev is a substructure that is mostly unused. Inside losOpLev, opPerror, opYerror, opYout seem to be unused, and opPout only seems ever to be set to 0.
Thats the end of ALL_CD_INFO and pCoilDriver.
After we have itmepics, itmfmdata, itmcoeffs, rmbsepics,...etymyepics, etmyfmdata,etmycoeffs which I don't see in use.
We have substructure asc inside mcasc, with epics, filt, and coeff char arrays. These seem to be asc and iowfsDrv specific.
lscIpc, lscepics, and lscla seems lsc specific,
The there is lscdiag struct, which contains v struct, which includes cpuClock, vmeReset, nSpob, nPtrx, nPtry don't seem to be used by the losLinux.c.
The lscfilt structure contains the FILT_MOD dspVME, which seems to be used only by lsc40m.
The lsccoeff structure contrains the VME_COEF pRfmCoeff, which again seems to only interact in the lsc code.
Then we have aciscpad, ascisc, ascipc, ascinfo, and mscepics which do not seem to be used.
ascepics and asccoeff are used in asc.c, but does not seem to be referenced elsewhere.
hepiepics , hepidsp, hepicoeff, hepists do not appear to be used.
|
2513
|
Wed Jan 13 12:03:00 2010 |
Alberto | Update | ABSL | Measurement now running. Please be careful | At the moment I'm running a measurement on the PRC and I'm planning to leave it going for the time we'll be at the 40m meeting.
Please be careful in the lab. Thank you. |
2512
|
Wed Jan 13 12:01:06 2010 |
Alberto | Update | Computers | c1dcuepics, c1lsc rebooted this morning | Since last night the alignemtn scripts couldn't work.
c1lsc wasn't working properly because attempts to lock the X arm would try to control ETMY and attempts of locking the Y arm, wouldn't actuate any optics.
Also, another sign of a malfunctioning c1lsc was that one of the LSC filter modules, FM6, couldn't get loaded properly. It looked like only half loaded on the LSC MEDM screen.
On the other hand, plotting the trend of the last month, c1lsc's CPU didn't look more loaded that usual.
Rebooting and restarting C1lsc wasn't enough and I also had to reboot c1dcuepics a couple of times beforse getting things back to work. |
2511
|
Tue Jan 12 14:28:01 2010 |
steve | Summary | Environment | lab temp of 7 years |
Quote: |
Quote: |
Rana noticed that recently the temperature inside the lab has been a little bit too high. That might be causing some 'unease' to the computers with the result of making them crash more often.
Today I lowered the temperature of the three thermostats that we have inside the lab by one degree:
Y arm thermostat: from 71 to 70 F
X arm thermostat: from 70 to 69 F
Aisle thermostat: from 72 to 71 F.
For the next hours I'll be paying attention to the temperature inside the lab to make sure that it doesn't go out of control and that the environment gets too cold.
|
Today the lab is perceptibly cooler.
The temperature around the corner is 73 F.
|
|
Attachment 1: labtemp7y.png
|
|
2510
|
Tue Jan 12 13:24:50 2010 |
Haixing | Update | SUS | Quadrant Magnetic Levitation | I have tried to make the quadrant magnetic levitation work but unfortunately I did not succeed. During the experiment, I have made
the following changes to the circuit and setup:
(1) I added small resistors (6K) in parallel to R11, R23, R35 and R47 (indicated in the following schematics) to increase
the control bandwidth from 20 Hz to 80 Hz.

(2) I changed RLED1, RLED2, RLED3, RLED4 from 2.2K to 1.5K in the LED driver such that the current of the
LED increases and in turn the displacement sensitivity increases.
(3) I changed R51 and R51 (in the differencing block for PD1 and PD2) from 5K to 1 K. Correspondingly,
I increased R52 and R54 from 5K to 50K. This changes increase the gain in the differential control by a
factor of 50, which compensates the gain loss after increasing the control bandwidth.
(4) The trim pots in the coil drive block have the following values: 100K for pot1 and pot4, 1K fro pot 2 and pot3.
To increase the gain, I replaced R17, R30, R31, R41 by 102 Om resistors (we run out of 100 Om chip resistors.)
(5) I wrapped the OSEM flags by plastic tubes to block the light from the LED more efficiently. This also removed
the changes of the photocurrent in the photodetector when the levitated plate moves horizontally.
Possible issues that cause the setup not working at the moment:
(1) The feedback gain could be probably still not enough. During the experiment, I can't feel any force changes when the
flags crossing the zero point. The error signals and control signal has the right sign.
(2) The levitated weight may be not enough and the working point is below the extremum of the DC attracting force.
This could give rise to a large negative spring which requires unreasonable feedback gain to compensate.
(3) The DC attracting force between the magnets are differing each other too much (mismatch) and can't
be compensated by the coil driving force.
(4) The control bandwidth may be still not large enough. Initially my design was 100 Hz, but I forgot to divide
the angular frequency by 2pi and the resulting circuit has a bandwidth of 20 Hz. Later I increase it up to 80 Hz
by changing the resistors as mentioned before.
(5) The polarization of the coil could have a wrong sign. I have checked with Gauss meter, but still the absence
of zero-point crossing force change makes me worry about this.
For continuation of this work, I will finish writing my document and summarize all the results and outline what
needs to be done in the future. If everything goes well, I will be back in June and can spend more time on this
experiment. I can also work with the summer students together on this project. |
2509
|
Tue Jan 12 11:34:26 2010 |
josephb | Update | PEM | Allegra dataviewer |
Quote: |
So that we can use both Guralps for Adaptive stuff, and so that I can look at the differential ground motion spectra, I've reconnected the Guralp Seismometers to the PEM ADCU, instead of where they've been sitting for a while connected to the ASS ADC. I redid the ASS.mdl file, so that the PEM and PEMIIR matricies know where to look for the Gur2 data. I followed the 'make ass' procedure in the wiki. The spectra of the Gur1 and Gur2 seismometers look pretty much the same, so everything should be all good.
There's a problem with DataViewer though: After selecting signals to plot, whenever I hit the "Start" button for the realtime plots, DataViewer closes abruptly.
When I open dataviewer in terminal, I get the following output:
allegra:~>dataviewer
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
msgget: No space left on device
allegra:~>framer4 msgget:msqid: No space left on device
Does anyone have any inspiration for why this is, or what the story is? I have GR class, but I'll try to follow up later this afternoon.
|
This problem seems to be restricted to allegra. Dataviewer works fine on Rosalba and op440m, as well as using ssh -X into rosalba to run dataviewer remotely. DTT seems to work fine on allegra. The disk usage seems no where near full on allegra. Without knowing which "device" its refering to (although it must be a device local to allegra), I'm not sure what to look at now.
I'm going to do a reboot of allegra and see if that helps.
Update: The reboot seems to have fixed the issue.
|
2508
|
Tue Jan 12 09:37:05 2010 |
Alberto | Update | ABSL | IFO available | I finished measuring the AbsL for this morning. The IFO is again available.
Please don't mess up with the interferometer though. I'll be back in a couple of ours |
2507
|
Tue Jan 12 09:14:52 2010 |
steve | Summary | General | Scattering Measurements of 35W Beam Dumps |
What was the power level, polarization and beam size at beam trap? |
2506
|
Mon Jan 11 21:49:17 2010 |
Jenne | Update | ABSL | Measurement running |
Quote: |
Leaving for dinner. Back in ~1hr.
I left a measurement running. Please don't interfere with it till I'm back. Thanks.
|
Per Alberto's instructions, I have closed the shutter on his laser so that the Adaptive Team can play with the Mode Cleaner. |
2505
|
Mon Jan 11 19:36:13 2010 |
Alberto | Update | ABSL | Measurement running | Leaving for dinner. Back in ~1hr.
I left a measurement running. Please don't interfere with it till I'm back. Thanks. |
2504
|
Mon Jan 11 16:59:14 2010 |
Alberto | Update | ABSL | Interferometer Busy | I'm currently running a measurement on the PRC.
Please don't interfere with the IFO until it is done. Talk with Alberto if you've been intending to work inside the lab.
Thank you. |
2503
|
Mon Jan 11 14:16:59 2010 |
Jenne | Update | PEM | Gur2 cables reconnected to the PEM ADCU | So that we can use both Guralps for Adaptive stuff, and so that I can look at the differential ground motion spectra, I've reconnected the Guralp Seismometers to the PEM ADCU, instead of where they've been sitting for a while connected to the ASS ADC. I redid the ASS.mdl file, so that the PEM and PEMIIR matricies know where to look for the Gur2 data. I followed the 'make ass' procedure in the wiki. The spectra of the Gur1 and Gur2 seismometers look pretty much the same, so everything should be all good.
There's a problem with DataViewer though: After selecting signals to plot, whenever I hit the "Start" button for the realtime plots, DataViewer closes abruptly.
When I open dataviewer in terminal, I get the following output:
allegra:~>dataviewer
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
msgget: No space left on device
allegra:~>framer4 msgget:msqid: No space left on device
Does anyone have any inspiration for why this is, or what the story is? I have GR class, but I'll try to follow up later this afternoon. |
2502
|
Mon Jan 11 11:06:53 2010 |
Alberto | Update | ABSL | Measurement running |
Quote: |
I'm working on the AbsL experiment. A measurement which involved the PRC locked is running at the moment.
Please make sure of not interfering with the interferometer until it is done. Thank you.
|
I'm done for the moement.
I realized that I need to take into account somehow the DC power from the photodiode. By now the measurement of the transmitted beat's power is affected by the total power circulating inside of the PRC and thus it depends on the cavity alignment.
I closed the laser shutter and turned down the flipping mirrors.
I'm planning to restart measuring by 2.30pm today. Till then the interferometer is available. |
2501
|
Mon Jan 11 10:01:06 2010 |
Alberto | Omnistructure | Environment | Lab Thermostats Temperature Lowered by 1 deg F |
Quote: |
Rana noticed that recently the temperature inside the lab has been a little bit too high. That might be causing some 'unease' to the computers with the result of making them crash more often.
Today I lowered the temperature of the three thermostats that we have inside the lab by one degree:
Y arm thermostat: from 71 to 70 F
X arm thermostat: from 70 to 69 F
Aisle thermostat: from 72 to 71 F.
For the next hours I'll be paying attention to the temperature inside the lab to make sure that it doesn't go out of control and that the environment gets too cold.
|
Today the lab is perceptibly cooler.
The temperature around the corner is 73 F. |
2500
|
Mon Jan 11 09:18:44 2010 |
Alberto | Update | General | Measurement running | I'm working on the AbsL experiment. A measurement which involved the PRC locked is running at the moment.
Please make sure of not interfering with the interferometer until it is done. Thank you. |
2499
|
Sun Jan 10 23:22:56 2010 |
Jenne | Summary | General | Scattering Measurements of 35W Beam Dumps | On Friday, Rana and I measured the scatter coming from the 35W beam dumps.
(These are the ones with big aluminum heat sinks on the back that kind of look like little robots with 2 legs...inside the horn is a piece of polished silicon at Brewster's Angle.)
SETUP:
For the measurement, we used the Scatterometer setup at the 40m on the small optical table near MC2.
We used a frequency of 1743 Hz for the Chopper, and this was also used as the reference frequency for the SR830 Lock-In Amplifier.
The settings on the Lock-In were as follows:
Input A
24dB/octave
AC coupled
Floating input
"Low Noise"
Time Constant = 1sec
'Scope reading Output A, Output A set to 'Display', and A's display set to "R" (as in magnitude).
Sensitivity changed throughout the experiment, so that's quoted for each measurement.
MEASUREMENTS:
White Paper Calibration - white paper placed just in front of Beam Dump. Sensitivity = 500microVolts. Reading on 'scope = 7V
Laser Shuttered. Sensitivity = 500microVolts. 'scope reading = 9mV.
Black Glass at Beam Dump location. Sensitivity = 500microVolts. Reading on 'scope = 142mV. (DON'T touch the glass....measure the same setup with different sensitivity)
Black Glass at Beam Dump location (Not Touched since prev. measurement). Sensitivity = 10microVolts. Reading on 'scope = 6.8V
Laser Shuttered. Sensitivity = 10microVolts. 'scope Reading = 14mV +/- 10mV (lots of fluctuation).
Black Glass Wedge Dump at Beam Dump location. Sensitivity = 10microVolts. 'scope = 100mV.
Beam Dump with original shiny front plate. Sensitivity = 10microVolts. 'scope railing at 11V
Beam Dump with front plate removed. Sensitivity = 10microVolts. 'scope reading = 770mV
Beam Dump, no front plate, but horn's opening surrounded by 2 pieces of Black Glass (one per side ~1cm opening), BG is NOT flush with the opening...it's at an angle relative to where the front plate was. Sensitivity = 10microV. 'scope = 160mV +/- 20mV.
Beam Dump, no front plate, only 1 piece of Black Glass. Sensitivity = 10microV. 'scope reading = 260mV.
Beam Dump, no front plate, 2 pieces of Black Glass, normal incidence (the BG is flush with where the front plate would have been). Sensitivity = 10microV. 'Scope reading = ~600mV
CALIBRATION:
Using our calibration numbers (Black Glass measured at 2 different sensitivities, not touching the setup between the measurements), we can find the calibration between our 2 different sets of measurements (at 500microV and 10microV), to compare our Beam Dump with regular white paper.
BG at 500uV was 142mV. BG at 10uV was 6.8V. 6.8V/0.142V = 47.9
So the white paper, which was measured at 500uV sensitivity, would have been (7V * 47.9) = 335 V in 10uV sensitivity units.
This is compared to the BG wedge dump at 10uV sensitivity of 100mV, and the Beam Dump reading of 770mV, and the Beam Dump with-black-glass-at-the-opening reading of 160mV.
So our Silicon/Steel horn dump is ~8x worse than a Black Glass wedge and (335 / 0.77) = 435x better than white paper.
We used regular white paper as a calibration because it has a Lambertian reflectance. For some general idea of how to do these kinds of scatter measurements, you can look at this MZ doc.
Assuming that our white paper had a BRDF of (1/pi)/steradian, we can estimate some numbers for our setup:
Sensitivity (signal with the laser shuttered) = (0.02 / 335 / pi) = 2 x 10^-5 / sr. This is ~3x worse than the best black glass surfaces.
Our wedge = (0.1 / 335 / pi) = 1 x 10^-4 / sr. Needs a wipe.
Our Silicon-Steel Horn = (0.75 / 335 / pi) = 7 x 10^-4 / steradian.
Our measurements were all made at a small angle since we are interested in scatter back along the incoming beam. We were using a 1" lens to collect the scatter onto a PDA55. The distance from the beam to the center of the lens was ~2" and the detector's lens was ~20" from the front of the horn. So that's an incident angle of ~3 deg.
CONCLUSIONS:
* It seems that any front plate other than Black Glass is probably worse than just having no front plate at all.
* If we put in a front plate, it shouldn't be normal to the incident beam. Black Glass at normal incidence was almost at the same level as having no front plate. So if we're going to bother with a front plate, it should be about 30deg or 40deg from where the original front plate was.
* No front plate on the Dump is about 7x a Black Glass wedge dump.
* The silicon looks like it might have some dust on it (as well as the rest of the inside of the horn). We should clean everything. (Maybe with deionized nitrogen?)
* We should remeasure the Beam Dump using polished steel at a small (30-40deg) angle as the front plate.
ATTACHMENTS:
* Photos taken with the Olympus camera, which has its IR blocker removed.
* In the photo you can see that we have a lot of reflection off of the horn on the side opposite from the silicon.
* The 2nd picture is of the scatterometer setup. |
Attachment 1: P1090014_copy.JPG
|
|
Attachment 2: ScatterometerSetup.png
|
|
2498
|
Sun Jan 10 17:15:25 2010 |
Koji | Update | SUS | transfer function measurement of the quadrant maglev circuit | 1. Yes. That is the bad. You should eventually replace the BNCs to the isolated ones.
2. OK. I like to emphasize again that everyone works on electronics should read data sheets more carefully and seriously because they have many important practical instructions to exploit full performance of the components.
Quote: |
Quote: |
1. Why do all of the BNCs have no GND connection? Each should have the individual cables to the ground. Each signal line and the corresponding ground line should be twisted together.
2. This looks the (usual) oscillation of the V-I conversion stage but I can't tell anything as I don't have the circuit diagram of the whole circuit.
3. In a certain case, putting some capacitance at the feedback may help. Read P.11 of the data sheet of LT1125. Try to put some capacitors from 20pF to some larger one whether it changes the situation or not. I suppose the bandwidth of your sensor can be ~1kHz. So putting a capacitance less than 10nF still has no effect to the servo.
|
1. They are all connected to the box which has a single connection to the board ground. If I connect each of them to the ground, there would be many small loops
of ground. Of course, I should have replaced all the connectors such that the they are disconnected to the box as point out by Robert.
2. The oscillation disappears after I add 5 nF capacitor in parallel to the existing resistor. Thank you very much for pointing this out.
|
|
2497
|
Sun Jan 10 16:50:34 2010 |
Haixing | Update | SUS | transfer function measurement of the quadrant maglev circuit |
Quote: |
1. Why do all of the BNCs have no GND connection? Each should have the individual cables to the ground. Each signal line and the corresponding ground line should be twisted together.
2. This looks the (usual) oscillation of the V-I conversion stage but I can't tell anything as I don't have the circuit diagram of the whole circuit.
3. In a certain case, putting some capacitance at the feedback may help. Read P.11 of the data sheet of LT1125. Try to put some capacitors from 20pF to some larger one whether it changes the situation or not. I suppose the bandwidth of your sensor can be ~1kHz. So putting a capacitance less than 10nF still has no effect to the servo.
|
1. They are all connected to the box which has a single connection to the board ground. If I connect each of them to the ground, there would be many small loops
of ground. Of course, I should have replaced all the connectors such that the they are disconnected to the box as point out by Robert.
2. The oscillation disappears after I add 5 nF capacitor in parallel to the existing resistor. Thank you very much for pointing this out. |
2496
|
Sun Jan 10 16:05:51 2010 |
Alberto | Omnistructure | Environment | Lab Thermostats Temperature Lowered by 1 deg F | Rana noticed that recently the temperature inside the lab has been a little bit too high. That might be causing some 'unease' to the computers with the result of making them crash more often.
Today I lowered the temperature of the three thermostats that we have inside the lab by one degree:
Y arm thermostat: from 71 to 70 F
X arm thermostat: from 70 to 69 F
Aisle thermostat: from 72 to 71 F.
For the next hours I'll be paying attention to the temperature inside the lab to make sure that it doesn't go out of control and that the environment gets too cold. |
|