40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 283 of 344  Not logged in ELOG logo
ID Date Authordown Type Category Subject Text Attachments
  8081   Wed Feb 13 22:09:26 2013 JenneUpdateAlignmentREFL is not clippedWe need to calculate whether this level
of astigmatism is expected from the new active
TT mirrors, but 
  
  8086   Fri Feb 15 01:51:43 2013 JenneSummaryAlignmentIFO aligned and ready for PRMI locking 
Yuta and Manasa, you guys are awesome!
Small, inconsequential point: 
  
  8116   Wed Feb 20 18:35:42 2013 JenneUpdateAlignmentNew in-vac alignment procedureI have updated the vacuum checklist for
in vacuum alignment.  Please take a
look (https://wiki-40m.ligo.caltech.edu/vent/checklist)
  
  8117   Wed Feb 20 18:53:48 2013 JenneUpdateAlignmentIFO ready for doors, then pumping[Yuta, Manasa, Sendhil, Jenne, Steve, Jamie,
Koji, Evan]
  
  8126   Thu Feb 21 12:56:38 2013 JenneUpdateCDSc1iscex dead againc1iscex is dead again.  Red lights,
no "breathing" on the FE status
screen.
  
  8127   Thu Feb 21 13:34:35 2013 JenneUpdateTreasureIR card removed

    

       
            
  
  8145   Sat Feb 23 14:52:03 2013 JenneUpdateLSCETMYT camera back to normal

    

       
            
  
  8149   Sat Feb 23 16:54:24 2013 JenneUpdateLSCcan't lock Y armI'm not sure that Yuta had found the real
Yarm flashes last night.  When I came
in today, the Yarm would flash.  However
  
  8163   Mon Feb 25 22:30:40 2013 JenneBureaucracyGeneralaction items for PRFPMI 
 CDS:
    - Check out ASS
  
  8165   Tue Feb 26 01:49:27 2013 JenneUpdateLockingPRMI locked[Jenne, Yuta]
We began the evening, after alignment
of all optics was good (arms flashing, PRC
  
  8171   Tue Feb 26 15:32:47 2013 JenneUpdateLockingFPMI locked

    

       
            
  
  8175   Wed Feb 27 00:08:43 2013 JenneUpdateIOOMeditations on converting TT channels to be more SUS-likeJamie and I have had a few back-and-forths
on this, but I wanted to write down my thoughts
on the parts of the SUS infrastructure that
  
  8176   Wed Feb 27 00:56:01 2013 JenneUpdateASSMotivation for reactivating the ASSI am putting a little bit of brain power
into reviving the ASS, and I want to write
down what the motivation is, and what the
  
  8178   Wed Feb 27 02:21:55 2013 JenneUpdateASSMotivation for reactivating the ASSI have modified the MeasureSpotPositions.py
script to accept the arms as valid cavities
(it used to give an error "Sorry, this
  
  8179   Wed Feb 27 02:44:39 2013 JenneUpdateLockingDRFPMI flashesBefore Yuta left, I asked him to restore
all optics to last saved values, to avoid
hysteresis.
  
  8180   Wed Feb 27 02:52:40 2013 JenneOmnistructureSAFETYBack door unlockedDid someone unlock the back door by the
(unofficial) bike storage lately?  Out
of habit, I checked the door behind me while
  
  8202   Thu Feb 28 14:51:43 2013 JenneUpdatePEM"Rock Monster" causing low frequency noiseManasa and I have been wondering why the
low frequency seismic noise has been different
in the last few days/weeks.  I went
 RockMonsterOn_ForFewMinutes.png 
  8203   Fri Mar 1 01:17:06 2013 JenneUpdateLSCXarm oscillationThere is an oscillation in the Xarm at
631Hz, which is not in the Yarm.  There
is a small peak in POY11_I at this frequency,
 POX11_630Hz_osc.pdf 
  8204   Fri Mar 1 02:49:34 2013 JenneUpdateASSArm A2L measurementI haven't finished debugging the scripts
so that the measurement is fully automatic,
like the MC, but I did measure the arm spot
 QUAD1_1046168242.bmp 
  8215   Sun Mar 3 22:16:46 2013 JenneUpdateLSCLSC whitening triggering started[Jenne, Annalisa]
We have started working on writing
the c-code to parse the LSC input matrix,
  
  8229   Tue Mar 5 01:43:04 2013 JenneUpdateASSArm A2L measurement script finishedIn either .../scripts/XARM or ...../scripts/YARM
run either A2L_XARM or A2L_YARM.
The wrapper script will, like the
 YARMdecenter.png 
  8234   Tue Mar 5 18:36:27 2013 JenneUpdateLSCLSC whitening triggering startedMore effort at debugging the LSC whitening. 
Today I tried moving things over
to the c1tst model, which runs on the y-end
  
  8246   Wed Mar 6 21:58:39 2013 JenneUpdateElectronicsPOX whitening was fine all alongAfter my investigations this afternoon
(with help from Sendhil and Shivaraj), 
  
  8249   Thu Mar 7 11:43:15 2013 JenneUpdateElectronicsPOX and POY whitening DC gain left lowManasa and Jan were having trouble locking
the Yarm, and asked me to take a look at
it.  After a good long time of trying
  
  8250   Thu Mar 7 12:39:12 2013 JenneUpdateLockingErudite discussion on PRMI locking[Rana, Jenne, Yuta] (late last night)
After some trouble getting the PRMI
to lock with REFL55 I&Q last night, we
  
  8253   Thu Mar 7 18:41:03 2013 JenneUpdateElectronicsPOX whitening was fine all alongHere are the transfer functions that we
took back in 2011 (see elog
4915 and replies) for POX:
 POX11I.pngPOX11Q.png 
  8258   Fri Mar 8 13:42:35 2013 JenneUpdateABSLBS installed on ITMY tableRe:  POY beam reduction.
We are able to lock the Yarm with
the beam / gain as it is.  I had thought
  
  8260   Fri Mar 8 16:02:52 2013 JenneUpdateAlignmentGetting closer to beam centering on YarmI'm working on getting the input beam centered
on the Yarm optics.  To do this, I measured
the spot positions, move the tip tilts, realign
 YARMdecenter_zoom_8Mar2013.png 
  8268   Mon Mar 11 14:10:05 2013 JenneUpdateEnvironmentMC suspensions moved by this morning's earthquakesNone of the suspensions
All suspensions were tripped (edited
by Manasa; see elog
 EQ.pngMC-SUS-kicked-EQ.png 
  8269   Mon Mar 11 15:52:46 2013 JenneUpdateIOOMC spots centered, WFS realignedLooking more into the MC, it appears that
no spot centering was done after the power
attenuation optics were removed (see elog
 MCspots_11Mar2013.png 
  8272   Mon Mar 11 19:01:21 2013 JenneUpdatePEMproposed seismometer locationsThis is my interpretation of where Steve
is proposing to place the seismometers (he
wrote ITMX southwest, but I'm pretty sure
 SeismometerProposedPositions_11March2013.pdf 
  8274   Tue Mar 12 00:35:56 2013 JenneUpdateComputersFB's RAID is beeping [Manasa, Jenne]
Manasa just went inside to recenter
the AS beam on the camera after our Yarm
  
  8275   Tue Mar 12 00:45:50 2013 JenneUpdateIOOMC weird again~20 minutes ago, maybe right around the
time the fb's RAID died (elog 8274)
the mode cleaner started behaving weirdly
  
  8277   Tue Mar 12 11:49:18 2013 JenneUpdateIOOMC weird again[Manasa, Annalisa, Jenne]
The MC wasn't locking on TEM00 this
morning, and the WFS kept pulling the MC
  
  8279   Tue Mar 12 14:02:22 2013 JenneUpdateAlignmentBeam drift - mystery partially solved?Steve just told those of us in the control
room that the custodian who goes into the
IFO room regularly steps on the blue support
  
  8281   Wed Mar 13 02:48:13 2013 JenneUpdateIOOMC all betterKoji reminded me (again....this is probably
the  2nd or 3rd time I've "discovered"
this, at least) that the script
  
  8290   Wed Mar 13 21:04:37 2013 JenneUpdateGreen LockingPSL green cleaned upBoth X and Y green are aligned such that
the arm beams hit the broadband PD. 
Also, the 4th port of the combining BS for
  
  8291   Thu Mar 14 04:20:54 2013 JenneUpdateGreen LockingYbeat attemptI dedicated my evening to trying to get
the Ygreen beatnote (the idea being to then
get the Xgreen beatnote).
  
  8293   Thu Mar 14 13:38:29 2013 JenneUpdateGreen LockingPSL green cleaned upI ran a cable to the GTRX camera. 
It is now input #2.  The videoswitch
script input naming is modified to match
  
  8294   Thu Mar 14 16:41:48 2013 JenneUpdateGreen LockingYarm ALS laser is funny / dying

    

       
            
  
  8297   Thu Mar 14 20:22:33 2013 JenneUpdateGreen LockingXbeat attemptI aligned the Xgreen and PSL green to overlap
on the X beat PD, and reconnected the splitter
which combines the X and Y beat signals and
  
  8298   Fri Mar 15 01:57:02 2013 JenneUpdateGreen LockingX arm green locked in TEM00This work earlier today had required moving
the harmonic separator back closer to its
original position, so that the green could
  
  8299   Fri Mar 15 02:14:27 2013 JenneUpdateCDSSimulink linking to wrong library partJamie and I discovered a problem with Matlab/Simulink
earlier today. 
In the end suspension models, there
  
  8300   Fri Mar 15 02:19:01 2013 JenneUpdateGreen LockingYarm ALS laser is funny / dyingI turned the laser back on around 1am. 
This is still happening, although right now
it is turning off more often than before,
  
  8302   Fri Mar 15 16:46:52 2013 JenneBureaucracyAuxiliary lockingYend table upgrade - fast track?In light of the Yend auxiliary laser's
ill health, I think we should reconsider
the possibility of changing out the Yend
  
  8304   Mon Mar 18 12:23:25 2013 JenneBureaucracyAuxiliary lockingYend table upgrade - go fetch NPRO from ATFZach has just replied, and said that we
should feel free to take
  
  8312   Tue Mar 19 19:19:50 2013 JenneUpdate40m UpgradingEndtable upgrade : INVENTORYDoes "Ready (in stock)" for the
base plates mean in stock at the company,
or in hand and already here in the
  
  8334   Mon Mar 25 09:52:22 2013 JenneUpdateComputersc1lsc mxstream won't restartMost of the front ends' mx streams weren't
running, so I did the old mxstreamrestart
on all machines (see elog
  
  8339   Mon Mar 25 16:51:59 2013 JenneUpdateOpticsupdated calculations of PRC/SRC g-factors and ARM mode matchingI think we like the idea of flipping SR2
better than SR3 for the same ghost beam reasons
as PR2 is better than PR3.  There isn't
  
  8347   Tue Mar 26 00:06:37 2013 JenneUpdateLockingAS beam put back on PD[Jenne, Gabriele]
We aligned MICH (first locked Yarm,
but didn't optimize since we don't have TRY,
  
ELOG V3.1.3-