40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 283 of 344  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  3095   Mon Jun 21 20:11:21 2010 KojiUpdatePhotosInspection of Magnets for the TTsWere these magnets chipped before the Ni
plating?
  
  3094   Mon Jun 21 18:01:34 2010 JenneUpdate40m UpgradingSRM, PRM hung, magnets inspected[Jenne, Kiwamu, Rana, Eric Gustafson]
The SRM and PRM have been re-hung,
and are ready for installation into the chambers. 
  
  3093   Mon Jun 21 14:21:34 2010 Jenne, KiwamuUpdatePhotosInspection of Magnets for the TTs    
  3092   Sun Jun 20 18:28:25 2010 kiwamuUpdateGreen LockingRe: lock with PDH boxOn the wiki I summarized about the modification
of the PDH box which is currently running
on the end PDH locking. 
  
  3091   Sun Jun 20 16:07:23 2010 KojiSummaryCOCCalibration of the metrology lab interferometerKiwamu and Koji
Summary
We have visited GariLynn's
 ring1_inner_centering.pdfring1_outer_centering.pdfSRMU01_pic.png 
  3090   Sat Jun 19 17:31:48 2010 ranaDAQCDSExcess Noise in C1:IOO-MC_DRUM1 fixed by rebootI was getting an excess noise in the C1:IOO-MC_DRUM1
channel - it was a flat spectrum of 10 cts/rHz
  
  3089   Fri Jun 18 22:12:29 2010 AlbertoUpdateIOOMode Profile after Mode Matching Telescope (Round 2)GJ   
  3088   Fri Jun 18 21:45:39 2010 kiwamuUpdateIOOMode Profile after Mode Matching Telescope (Round 2)    
      
 MMT20100618_edit.pngnewIOO_overlap_edit.png 
  3087   Fri Jun 18 15:07:26 2010 AlbertoUpdateLSCShort Cavity Length Adjustments


   
        
            
  
  3086   Fri Jun 18 13:47:20 2010 KojiUpdateLSCShort Cavity Length AdjustmentsYou should have been in my lecture yesterday!
Power in the cavity is not a good
index (=error signal) to judge the optimal
  
  3085   Fri Jun 18 13:42:52 2010 KojiHowToGeneralUpdate your workAll SURFs (and all others as always) are
supposed to post the update of your status
on the elog.
  
  3084   Thu Jun 17 17:09:44 2010 AlbertoUpdateLSCShort Cavity Length AdjustmentsI calculated the phase shifts that the
sidebands would pick up in the arms in the
case we changed the arm length to 38.4m as
  
  3083   Wed Jun 16 18:44:07 2010 AlbertoConfigurationComputers40MARS


   
        
            
  
  3082   Wed Jun 16 18:14:13 2010 AidanUpdateGeneralGlass cover from overhead light smashed on PSL tableI was giving a tour of the 40m yesterday.
We were looking at the PSL table. About 30
seconds after I turned the lights on a glass
 DSC_1769.JPGDSC_1768.JPG 
  3081   Wed Jun 16 18:12:16 2010 nancyConfigurationComputers40MARSi added my laptop's mac address to teh
martian at port 13 today.
 
  
  3080   Wed Jun 16 11:31:19 2010 josephbSummaryComputersRemoved scaling fonts from medm on AllegraBecause it was driving me crazy while working
on the new medm screens for the simulated
plant, I went and removed the aliased font
  
  3079   Tue Jun 15 21:28:44 2010 albertoUpdateLocking40m Upgrade Optickle Model


   
        
            
 allTransferFunctions_DARMoff_0.pdfallTransferFunctions_DARM2AS_10pmDARMoffset.pdfJan_DARM2AS.pdf 
  3078   Tue Jun 15 19:24:25 2010 ranaUpdateIOOMode Profile after Mode Matching Telescope


   
        
            
  
  3077   Tue Jun 15 16:28:32 2010 kiwamuUpdateIOOMode Profile after Mode Matching TelescopeWe obtained
a good mode match overlap of 99.0% for the
 newIOO_overlap_edit.png 
  3076   Mon Jun 14 22:16:08 2010 JenneUpdateIOOMode scan after Mode Matching Telescope[Jenne, Kiwamu]
We measured the mode after the Mode
Matching Telescope. 
 after_MMT.png 
  3075   Mon Jun 14 07:57:07 2010 albertoUpdateLocking40m Upgrade Optickle Model

    
        
  
  3074   Sun Jun 13 08:28:44 2010 valeraUpdateLocking40m Upgrade Optickle Model In my calculation of the digital
filters of the optical transfer functions
the carrier light is resonant in coupled
  
  3073   Sat Jun 12 19:43:19 2010 AlbertoUpdateWIKI-40M UpdateIFO modeling Wiki Page updatedToday I started writing the IFO modeling
wiki page.
The idea is to make it a reference
  
  3072   Sat Jun 12 19:41:04 2010 AlbertoUpdateLocking40m Upgrade Optickle ModelI wrote down the settings according to
which I tuned the optickle model of the 40m
Upgrade.
 optickleIFOworkingpoint.pdf 
  3071   Sat Jun 12 18:03:00 2010 sharmilaUpdateelogTemperature ControllerKiwamu and I setup a serial port terminal
for receiving data from TC200 via a RS-232
USB interface. It was done using a Python
  
  3070   Fri Jun 11 22:09:58 2010 valeraHowToCDSfoton It appears that foton does not like
the unstable poles, which we need to model
the transfer functions.
  
  3069   Fri Jun 11 15:04:25 2010 josephbUpdateCDSMulti-filter matrix medm screens finished and script for copying filters from SOS fileI've finished the MEDM portion of the RCG
FiltMuxMatrix part.  Now it generates
an appropriate medm screen for the matrix,
 FiltMatrixMedm.png 
  3068   Fri Jun 11 14:31:04 2010 kiwamuUpdateIOOmode matching of new IOOWe decided not to care about the mode
after MMT1.
 profile_MMT.pngdist_MMO.png 
  3066   Fri Jun 11 13:32:28 2010 KojiUpdateGreen Lockingend PDH with thermal feedbackGJ! 

  
  3065   Fri Jun 11 11:54:42 2010 kiwamuUpdateGreen Lockingend PDH with thermal feedbackA thermal
feedback was installed to the end PDH locking
 LPF.pngthermal_feedback.png 
  3064   Thu Jun 10 11:10:21 2010 AlbertoUpdateGeneralLaTeXlabs


   
        
            
  
  3063   Thu Jun 10 10:58:02 2010 KojiUpdateGeneralLaTeXlabsI could not dare to share my google doc
with this site...

  
  3062   Thu Jun 10 07:53:14 2010 AlbertoUpdatePEMLaTeXlabs


   
        
            
  
  3061   Wed Jun 9 21:05:44 2010 ranaSummaryComputersop540m is not to be usedThis is a reminder (mainly for Steve, who somehow   
  3060   Wed Jun 9 19:47:08 2010 nancyUpdatePEMlead balls on concrete


   
        
            
  
  3059   Wed Jun 9 11:13:11 2010 kiwamuUpdateGreen Lockinglock with PDH boxA
progress on the end PDH locking :
  
  3058   Wed Jun 9 10:31:13 2010 steveUpdateSAFETYsafety trainingNancy and Sharmila received introductory
early bird surf safety training for the 40m
lab.
  
  3057   Tue Jun 8 20:52:25 2010 josephbUpdatePEMDAQ up (for the moment)As a test, I did a remote reboot of both
Megatron and c1iscex, to make sure there
was no code running that might interfere
  
  3056   Tue Jun 8 18:39:36 2010 ranaUpdatePEMDAQ down

    
  
  3055   Tue Jun 8 15:58:25 2010 josephb, alexUpdateCDSNew multi-filter matrix part added to RCG (at the 40m at least)A new webview of the LSP model is available
at:
https://nodus.ligo.caltech.edu:30889/FE/lsp_slwebview_files/
 CDS_Library.png 
  3054   Tue Jun 8 00:38:22 2010 Koji, KiwamuUpdateIOOimproved Gaussian beam in new IOOThe shape
of the beam spot in the new input optics
 2010-6-7_2.png 
  3053   Mon Jun 7 07:39:38 2010 AlbertoOmnistructureElectronicsCapacitor Bridge Test


   
        
            
  
  3052   Sun Jun 6 08:08:05 2010 rana, sanjitSummaryElectronicsCapacitor Bridge TestTo get a feel for the Capacitive Bridge
problems, we setup a simple bridge using
fixed (1 nF) caps on a breadboard. We used
 CapacitanceBridge.png 
  3051   Sun Jun 6 04:48:41 2010 ranaUpdateCOCITM01 HR Phase MapWhile trying to set up the SIS-FFT to use
our new ITM phase maps, I noticed that the
surface of our ITMs looks pretty good actually
 itm01hr.png 
  3050   Fri Jun 4 23:52:57 2010 ranaUpdatePEMseismometers off of linoleum floor   Untitled.pnghuddlez.png 
  3049   Fri Jun 4 11:32:51 2010 Alberto, kiwamuUpdateIOOMC MMT1 Mirror Tests[Alberto, Kiwamu]
Last Wednesday,
we measured the beam profile after the MC
mode matching telescope n.1 (MMT1). We found
 MCMMT1spareOpticsTestSetup.png 
  3048   Thu Jun 3 22:33:31 2010 valeraSummaryCDSsimulated plant work I put matlab files and a summary
into the 40m wiki for the fitting of the
40m Optickle transfer functions and generating
  
  3047   Thu Jun 3 22:17:05 2010 ranaUpdatePEMseismometers off of linoleum floor At ~2350 UTC on June 2, the seismometers
were turned off. After the granite slab was
repositioned with the new lead, the Ranger
 Untitled.pnga.pngUntitled.png 
  3046   Thu Jun 3 14:40:28 2010 Alberto, KiwamuUpdateIOOmode measurement of new input optics


   
        
            
  
  3045   Thu Jun 3 14:13:20 2010 JenneUpdateIOOmode measurement of new input optics


   
        
            
  
ELOG V3.1.3-