40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 283 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  1598   Mon May 18 02:18:17 2009 ranaSummarySEIUsing STACIS w/ a good position sensor[FONT=Verdana]WE turned off STACIS a few years
ago because we noticed that it was causing
noise below a few Hz and making
 stacis40.png 
  1600   Mon May 18 15:31:11 2009 ranaUpdatePEMTemp sensor[quote]Picture of cooler for posterity is
attached[/quote]
 Untitled.png 
  1602   Mon May 18 20:16:20 2009 ranaConfigurationVACnot itThere was essentially no change in the ETMY
oplev spectrum with the cryo off!
 a.png 
  1603   Mon May 18 21:34:18 2009 ranaConfigurationSUSETMY f2pRatio script runNow that the ETMY optical lever is not so
bad, I ran the f2pRatio script and it seems
to have worked.
  
  1608   Tue May 19 16:08:03 2009 ranaSummarySEIEUCLIDFrom Stuart Aston, I've attached a picture
of the EUCLID position sensor:
 Picture_6.png 
  1617   Thu May 21 18:07:32 2009 ranaUpdatePSLScrew on Needle valve loosenedAlberto and I went in to loosen up the needle
valve yesterday around 4:30 PM. The idea
was to cut down on 
 Untitled.png 
  1618   Thu May 21 18:21:57 2009 ranaSummaryTreasureYoichi's words    
  1639   Mon Jun 1 15:01:31 2009 ranaUpdatePSLLaser Power after fixing the laser chiller: more tracesIf you look at the correlation between RMTEMP
and HTEMP, you see what we knew: namely that
there
 Picture_7.png 
  1640   Mon Jun 1 19:19:26 2009 ranaUpdatePSL1000 days of hour-trend   u.png 
  1646   Wed Jun 3 03:30:52 2009 ranaUpdateMOPANPRO current adjustI increased the NPRO's current to the max
allowed via EPICS before the chiller shutdown.
Yesterday, I did this
 Untitled.png 
  1649   Wed Jun 3 18:55:27 2009 ranaUpdateCOCsnapshot of upgrade layout   layout.png 
  1689   Sun Jun 21 00:08:26 2009 ranaConfigurationComputerselog rebooted 
nodus:log>dmesg
  
  1702   Thu Jun 25 17:27:42 2009 ranaUpdateComputerstdsresp on linux I downloaded the tdsresp.pl from LLO and put
it into the various TDS/bin paths. Also updated
the LLO specific path stuff. It runs.
  
  1706   Fri Jun 26 19:14:04 2009 ranaUpdateEnvironmentseisBLRMS for the past 3 weeks[COLOR=chocolate][SIZE=2]Restarted the seisBLRMS.m
on mafalda (running a term on op540m). Don't
know why it stopped - the
  
  1727   Thu Jul 9 02:18:09 2009 ranaUpdatePEMBonnie moved to PSL, getting some coherence with the PMC_ERR channelMy guess is that we need a different acoustic
strategy. The microphones are mainly for
high frequencies, 
  
  1729   Thu Jul 9 19:24:50 2009 ranaUpdatePEMmore mic position changes; mics not picking up high frequenciesMight be the insidious 850 Hz AA filters in
the black AA box which precedes the ADC.
  
  1730   Fri Jul 10 17:32:08 2009 ranaUpdateEnvironmentseisBLRMS & mafalda restartedRana, Alberto

Mafalda's ethernet cable had fallen out of
  
  1732   Sun Jul 12 20:05:06 2009 ranaOmnistructureEnvironmentChanged office tempThis is a 7-day minute trend. There's [B]no
obvious effect[/B] in any of the channels
looking back 2 days. 
 Picture_3.png 
  1738   Mon Jul 13 15:48:05 2009 ranaOmnistructureEnvironmentRemoval of the cold air deflection device for the MOPA chillerAround 2 PM today, I removed the blue flap
which has been deflecting the cold air from
the AC down into the laser chiller.
  
  1761   Sat Jul 18 19:49:48 2009 ranaUpdatePEMGuralp Box FailThat's terrible: R5 & R8 should definitely
be 100 Ohm and not 100kOhm. 100k would make
it a noise disaster. They should also be
 Picture_1.pngPicture_2.pngAD620.pdf 
  1793   Sun Jul 26 13:19:54 2009 ranaUpdatePSLAligning the mode cleanerI set the MC back to its good alignment
(June 21st) using this
procedure. The trend of the OSEM values
 Untitled.png 
  1796   Mon Jul 27 14:12:14 2009 ranaSummarySUSTM Coil Noise SpectraRob noticed that the ITMY DAC channels were
saturating occassionally. Looking at the
spectrum we can see why.
 Coils.pdf 
  1809   Wed Jul 29 19:31:17 2009 ranaConfigurationComputerselog restartedJust now found it dead. Restarted it. Is
our elog backed up in the daily backups?
  
  1814   Thu Jul 30 21:26:16 2009 ranaUpdateIOOMC Drumhead modeI used COMSOL 3.5a to do a FEA of one of the
MC flat mirrors. Should be close to the same
for all the mirrors.
 mc2drum.png 
  1851   Fri Aug 7 00:10:14 2009 ranaUpdatePSLRef cav reflection PD is funkywe have a tester cable, but you don't want
it. Instead the problem is probably at the
cross-connect. The D-cable goes to a cross-connect
  
  1867   Sat Aug 8 15:08:14 2009 ranaConfigurationPSLSMOO settings updated in psl.db and SVN updatedI have added/modified SMOO settings to
all of the records in psl.db appropriately.
Changes checked in to SVN.
  
  1868   Sat Aug 8 17:19:07 2009 ranaUpdatePEMTwo Guralps plugged in, prepped for huddle test I found that several of the cables
are unlabeled so I'm not sure what's plugged
in. In the end, I found that the TEMP_2,
 Untitled.png 
  1869   Sat Aug 8 17:23:29 2009 ranaUpdatePEMoffensive 2 Hz sine wave removedFriday, we were seeing a 2 Hz harmonic
series in all of the PEM channels. Today
I found that some bad person had put in
  
  1870   Sun Aug 9 16:32:18 2009 ranaUpdateComputersRCG work. MDC MDP open loop transfer functionThis is very nice. We have, for the first
time, a real time plant with which we can
test our changes of the control system. From
 a.png 
  1887   Tue Aug 11 23:17:21 2009 ranaSummaryComputersNodus rebooted / SVN downLooks like someone rebooted nodus at ~3
PM today but did not elog it. Also the SVN
is not running. Why?
  
  1897   Thu Aug 13 09:22:06 2009 ranaUpdatePEMrangerRana, Jan, Jenne
We noticed that the Ranger data was
all bogus at low frequencies. So we checked
  
  1912   Sat Aug 15 18:57:48 2009 ranaUpdateVACUPS failedAs Rob noted last Friday, the UPS which
powers the Vacuum rack failed. When we were
trying to move the plugs around to debug
  
  1920   Mon Aug 17 17:43:11 2009 ranaSummaryGeneralconlogger restartedAdded the conlog directory to the SVN,
minus the enormous data directory. We are
now free to make changes to the conlog code.
  
  1927   Wed Aug 19 02:17:52 2009 ranaOmnistructureEnvironmentControl Room Workstation desks lowered to human heightThere were no injuries...Now we need to
get some new chairs.
  
  1938   Tue Aug 25 00:35:04 2009 ranaUpdateGeneralTransfer function of Mode Cleaner StacksLooks like all of the accelerometers and
seismometers have been disconnected since
early AM last Monday when Clara disconnected
 Untitled.png 
  1939   Tue Aug 25 01:27:09 2009 ranaConfigurationComputersRaid update to Framebuilder (not quite)


   
        
            
  
  1940   Tue Aug 25 02:37:53 2009 ranaConfigurationComputer Scripts / ProgramsFirefox 3.5 installed for 64 bit linux in apps/   DSC_0620.JPG 
  1942   Tue Aug 25 11:02:39 2009 ranaSummaryPSLTemperature BoxThe PSL Temperature Box (D980400-B-C, what
kind of numbering scheme is that?) modified
at LHO/LLO ~8 years ago to have better resolution
 D980400-B.pdf 
  1946   Tue Aug 25 21:55:11 2009 ranaUpdatePSLreference cavity temp box temporarly out of orderThere's no elog entry about what work has
gone on today, but it looks like Peter took
apart the reference cavity temperature control
 Untitled.pngrc-heater.jpg 
  1956   Thu Aug 27 13:42:08 2009 ranaSummaryPSLReference Cavity Temperature Control: psl.db changesI made the changes
to the psl.db to handle the new Temperature
  
  1957   Thu Aug 27 14:00:33 2009 ranaUpdatePSLRC thermal servo impulse responseI stepped the TIDALSET and looked at
what happened. Loop was closed with the very
 Untitled.png 
  1968   Mon Sep 7 20:05:18 2009 ranaUpdatePSLRCTEMP v. RMTEMPSince ~Aug. 27, the reference cavity has
been running with no thermal control. This
is not really a problem at the 40m; a 1 deg
 rct2.pngrct.png 
  1970   Mon Sep 7 23:35:03 2009 ranaUpdatePSLRC thermal servo: PID script modified, database + screen addedI have added the records for the RC thermal
PID servo into the psl/slowpid.db file which
also holds the records for the SLOW servo
 Untitled.png 
  1971   Mon Sep 7 23:51:48 2009 ranaConfigurationComputersmatlab installed: 64-bit linuxI have wiped out the 2008a install of 64-bit
linux matlab and installed 2009a in its place.
Enjoy.
  
  1976   Tue Sep 8 19:30:33 2009 ranaUpdatePSLc1psl rebooted for new RCPID database settingsThe RC thermal PID is now controllable
from its own MEDM screen which is reachable
from the FSS screen. The slowpid.db and
 c1psl-term-dump.txt.gzC1PSL_FSS_RCPID.pngPicture_1.png 
  1983   Thu Sep 10 18:25:15 2009 ranaUpdatePSLc1psl rebooted for new RCPID database settingsI added a new database record (C1:PSL-FSS_RCPID_SETPOINT)
to allow for changing of the RC setpoint
while the loop is on. This will enable us
  
  1986   Sat Sep 12 15:40:15 2009 ranaUpdatePSLRC response v. can temperatureI stepped the RC can temperature  Picture_2.pngUntitled.pdf 
  1995   Wed Sep 23 19:36:41 2009 ranaUpdatePSLRC temperature performanceThis first plot shows the RC temperature
channels' performance from 40 days ago, before
we disabled the MINCO PID controller. Although
 Untitled.pngUntitled.pnge.png 
  1998   Thu Sep 24 19:35:20 2009 ranaHowToPhotos40m Google accountI've created a 40m Google account. Please
post all the 40m related photos to this site.
If you don't already have it, download Picasa
  
  1999   Thu Sep 24 20:17:05 2009 ranaSummaryLSCComparison of Material Properties for the new RFPD Mounts
    

       
             
  
ELOG V3.1.3-