ID Date Author Typeup Category Subject Text Attachments
  13374   Wed Oct 11 19:31:32 2017 gautamUpdateLSCAS55Q Dark NoiseI tried replacing the AD797s on the daughter
board with OP27s, and saw no significant
improvement in the electronics noise of the
 AS55Q_darkNoises.pdf 
  13376   Thu Oct 12 01:50:11 2017 gautamUpdateLSCAS55Q Dark NoiseI worked on the daughter board a little
more in the evening. I have somehow managed
to make the dark noise ~25% worse [Attachment
 AS55_dark.png 
  13378   Thu Oct 12 12:17:28 2017 gautamUpdateLSCAS55Q Dark NoiseHere is the marked up schematic with the
board as it is stuffed. Annoyingly, there
is a capacitor (C1) which according to the
 D040179_AS55_40m.pdf 
  13379   Thu Oct 12 14:42:45 2017 gautamUpdateCDSslow machine bootfestSteve reported problems getting the X arm
locked. Alignment sliders were inaccessible.
Eurocrate key turning reboots for 
  
  13380   Fri Oct 13 12:26:12 2017 gautamUpdateLSCAS55Q Dark NoiseAttachment #1 -
Measured / modelled noises for AS55 demod
board. I've plotted quadrature sum of
 AS55_DemodNoises.pdf 
  13381   Mon Oct 16 12:13:38 2017 gautamUpdateCDSMegatron maintenanceWall StripTool traces showed that IMC has
not been locked for at least 8 hours when
I came in this morning. Going to the IMC
  
  13382   Mon Oct 16 16:01:04 2017 gautamUpdateLSCAS55Q Dark NoiseKoji suggested looking at the output of
the AS55 demod board on a fast oscilloscope
to look for differences in the two channel
 DemodBoardwOscope.pdfDemodBoardwOscope_ASD.pdf 
  13384   Tue Oct 17 19:31:53 2017 gautamUpdateLSCAS55Q Dark Noise[Koji, gautam]

We took a closer look at the AS55
demod board today. The procedure was to just
 D040179_TFs.pdfAS55_DemodNoises.pdf 
  13385   Tue Oct 17 23:07:52 2017 gautamUpdateCDSFEs unresponsiveWhile working on the IFO tonight, I noticed
that the blinky status lights on c1iscex
and c1iscey were frozen (but those on the
  
  13386   Wed Oct 18 01:41:32 2017 jamieUpdateCDSFEs unresponsive


  
  13387   Wed Oct 18 02:09:32 2017 gautamUpdateCDSFEs unresponsiveI was looking at the ASDC channel on dataviewer,
and toggling various settings like whitening
gain. At some point, the signal just froze.
  
  13388   Wed Oct 18 09:21:22 2017 jamieUpdateCDSFEs unresponsive


  
  13392   Wed Oct 18 17:34:09 2017 gautamUpdateSUSASDCSummary:

The signal path for the ASDC signal
is AS55
  
  13393   Wed Oct 18 19:17:42 2017 gautamUpdateGeneralPRC angular feedforwardLast night, I collected ~30mins of data
for the vertex seismometer channels and the
POP QPD PIT/YAW signals with the PRMI locked
 pop_feedforward_potential.pdf 
  13394   Wed Oct 18 23:11:53 2017 gautamUpdateCDSFEs unresponsiveThis happened again just now - it was roughly
this time when this happened last night as
well.
  
  13396   Fri Oct 20 16:30:17 2017 gautamUpdateCDSFB1 installed on shelves[steve, jamie, gautam]

The machine that now serves as
out Frame Builder, FB1, was sitting on top
  
  13397   Mon Oct 23 09:17:41 2017 SteveUpdatePEMants alartDo not leave organic trash or food boxes
in the 40m to attrack ants !
 ants.jpgants2.jpg 
  13398   Tue Oct 24 16:22:53 2017 gautamUpdateCDSToy DARM model setup in c1tst[alex, gautam]

Alex is going to have an undergrad
work on a calibration optimization project
 TOY_DARM.pngTOY_DARM_SIMULINK.png 
  13399   Tue Oct 24 16:43:11 2017 SteveUpdateCDSslow machine bootfest[ Gautam , Steve ]

c1susaux
  
  13402   Fri Oct 27 09:34:20 2017 SteveUpdatePEMearthquakesLompoc 4.3M and 3.7M Avalon

 
 recentEQs.png 
  13403   Fri Oct 27 10:14:11 2017 SteveUpdateVACRGA scan at day 372Valve configuration: Vacuum normal

Note: Tp2 running at 75Krpm 0.25A
26C has a  load high pitch sound today.
 RGA_scan_d372.png 
  13404   Sat Oct 28 00:36:26 2017 gautamUpdateCDS40m files backup situation - ddrescueNone of the 3 dd backups I made were bootable
- at boot, selecting the drive put me into
grub rescue mode, which seemed to suggest
 415E2F09-3962-432C-B901-DBCB5CE1F6B6.jpegBFF8F8B5-1836-4188-BDF1-DDC0F5B45B41.jpeg 
  13406   Mon Oct 30 08:08:06 2017 SteveUpdatesafetysafety trainingUdit Kahndelwal received 40m specific basic
safety traning on Friday, Oct. 27
  
  13407   Mon Oct 30 10:09:41 2017 SteveUpdateVACTP2 failed IFO pressure 1.2e-5 Torr at 9:30am




 tp2failed.pngifo_1.0E-5_Torrit.pngtp2failed2dago.png4days.png 
  13408   Mon Oct 30 11:15:02 2017 gautamUpdateCDSslow machine bootfest + vacuum snafuEurocrate key turning reboots today morning
for c1psl
  
  13409   Mon Nov 6 09:09:43 2017 SteveUpdateVACsetting up new TP2 turboOur new Agilent Technology TwisTorr
84FS AG rack controller ( English Manual
pages 195-297 )  RS232/485, product
  
  13410   Mon Nov 6 11:15:43 2017 gautamUpdateCDSslow machine bootfest + IFO re-alignmentEurocrate key turning reboots today morning
for
  
  13412   Tue Nov 7 17:45:05 2017 gautamUpdateLSCDRMI Nosie Budget v3.1Some days ago, I had tried to measure the
SRCL->MICH and PRCL->MICH cross couplings
using broadband noise injected between 120-180
 SRCL_MICH_whitenoise_tf.pdfPRCL_MICH_whitenoise_tf.pdfMICH_aux.pdfC1NB_disp_40m_MICH_NB_2017-10-08.pdf 
  13413   Tue Nov 7 22:56:21 2017 gautamUpdateLSCDRMI locking recoveredI hadn't re-locked the DRMI after the
work on the AS55 demod board. Tonight, I
was able to recover the DRMI locking with
 DRMI_7Nov20178.png 
  13414   Wed Nov 8 00:28:16 2017 gautamUpdateLSCLaser intensity coupling measurement attemptI tried measuring the coupling of PSL intensity
noise by driving some broadband noise bandpassed
between 80-300Hz using the spare DAC channel
 PSL_RIN.pdf 
  13415   Wed Nov 8 09:37:45 2017 ranaUpdateLSCDRMI Nosie Budget v3.1why no oplev trace in the NB ?




  
  13416   Wed Nov 8 09:59:12 2017 gautamUpdateLSCDRMI Nosie Budget v3.1The Oplev trace is missing for now, as
I have not re-measured the A2L coupling since
modifying the Oplev loop shape (specifically
  
  13417   Wed Nov 8 12:19:55 2017 gautamUpdateSUScoil driver series resistanceWe've been talking about increasing
the series resistance for the coil driver
path for the test masses. One consequence
 vthresh.pdf 
  13418   Wed Nov 8 14:28:35 2017 gautamUpdateGeneralMC1 glitches returnThere hasn't been a big glitch that
misaligns MC1 by so much that the autolocker
can't lock for at least 3 months, seems
 MC1_glitchy.png6AFDA67D-79B1-469C-A58A-9EC5F8F01D32.jpeg 
  13419   Wed Nov 8 16:39:24 2017 KiraUpdatePEMADC noise measurementGautam and I measured the noise of the
ADC for channels 17, 18, and 19. We plan
to use those channels for measuring the noise
 ADC-fit.pngIMG_20171108_162532.jpgIMG_20171108_162556.jpg 
  13420   Wed Nov 8 17:04:21 2017 gautamUpdateCDSgds-2.17.15 [not] installedI wanted to use the foton.py utility for
my NB tool, and I remember Chris telling
me that it was shipping as standard with
  
  13422   Thu Nov 9 15:33:08 2017 johannesUpdateCDSrevisiting Acromag


  
  13423   Fri Nov 10 08:52:21 2017 SteveUpdateVACTP3 drypump replacedPSL shutter closed at 6e-6 Torr-it    

   The foreline pressure
of the drypump is 850 mTorr at 8,446 hrs
  
  13424   Fri Nov 10 13:46:26 2017 SteveUpdatePEMM3.1 local earthquakeBOOM
SHAKA-LAKA
 3.1M_local_EQ.png 
  13426   Tue Nov 14 08:54:37 2017 SteveUpdateIOOMC1 glitching   MC1_glitching.png 
  13428   Wed Nov 15 01:37:07 2017 gautamUpdateLSCDRMI low freq. nosie improvedPianosa
just crashed and ate my elog, along with
 C1NB_disp_40m_MICH_NB_2017-11-15.pdfOL_A2L_couplings.pdf 
  13429   Thu Nov 16 00:14:47 2017 Udit KhandelwalUpdateSUSSOS Sapphire Prism designSummary:


SOS solidworks model is
nearly complete

Having trouble
  
  13430   Thu Nov 16 00:45:39 2017 gautamUpdateSUSSOS Sapphire Prism design 




  
  13431   Thu Nov 16 00:53:26 2017 gautamUpdateLSCDRMI noise sub-budgetsI've incorporated the functionality
to generate sub-budgets for the various grouped
traces in the NBs (e.g. the "A2L"
 C1NB_a2l_40m_MICH_NB_2017-11-15.pdfC1NB_aux_40m_MICH_NB_2017-11-15.pdf 
  13432   Thu Nov 16 13:57:01 2017 gautamUpdateOptical LeversOptical lever noiseI disabled the OL loops for ITMX, ITMY
and BS at GPStime 1194897655 to come up with
an Oplev noise budget. OL spots were reasonably
 VertexOLnoise.pdfITMYvsSRM.pdf 
  13433   Thu Nov 16 15:43:01 2017 ranaUpdateOptical LeversOptical lever noiseI bet the calibration
is out of date; probably we replaced the
  
  13436   Tue Nov 21 11:21:26 2017 gautamUpdateCDSRFM network downI noticed yesterday evening that I wasn't
able to engage the single arm locking servos
- turned out that they weren't getting
 RFMerrors.png 
  13437   Tue Nov 21 11:37:29 2017 gautamUpdateOptical LeversBS OL calibration updatedI calibrated the BS oplev PIT and YAW error
signals as follows:


Locked X-arm, ran dither
 OL_calib_BS_PERROR.pdfOL_calib_BS_YERROR.pdfVertexOLnoise_updated.pdf 
  13438   Tue Nov 21 16:00:05 2017 KiraUpdatePEMseismometer can testingI performed a test with the can last week
with one layer of insulation to see how well
it worked. First, I soldered two heaters
 cooling_fit.pngIMG_20171121_164835.jpg 
  13439   Tue Nov 21 16:28:23 2017 gautamUpdateOptical LeversBS OL calibration updatedThe numbers I have from the fitting don't
agree very well with the OSEM readouts. Attachment
#1 shows the Oplev pitch and yaw channels,
 BS_oplev_sweep.png 
ELOG V3.1.3-