  485   Sun May 18 18:44:48 2008 ranaSummarySUSOptical Lever SUM Trend - 80 daysI used the OL-Trend.xml dataviewer template
to make this plot. Looks like the ETMY optical
lever
 e.pdf 
  486   Sun May 18 18:59:15 2008 ranaConfigurationComputerscron and hostsI added rosalba to the hosts file for the
control room machines (131.215.113.103).
  
  493   Fri May 23 08:24:24 2008 ranaAoGTreasureYoichi Aso has arrived !   Colossus_back_(800_x_600)-thumb.jpg 
  495   Sun May 25 16:20:27 2008 ranaConfigurationComputersjoinPDFI have installed joinPDF 2.1 on rosalba. Since
its written in Java, I didn't have to tinker
with it at all to work on a 64-bit machine.
  
  496   Sun May 25 19:33:16 2008 ranaUpdateIOOMC Bad after Re-alignmentThe MC pointing was off and the transmitted
power was down after John and Andrey brought
it back after the bootfest.
 e.pdfpmc.png 
  497   Sun May 25 20:30:25 2008 ranaSummaryPSLPMC Mode MatchingI checked the PMC mode matching by ramping
the gain down to -10 dB (from +20 dB) and
moving the DC offset around until it caught
 pmc.png 
  499   Sun May 25 22:33:00 2008 ranaUpdateSUSETMY Oplev WorkI found the ETMY table in disarray and put
the panels back on and put the ETMY OL laser
back on the quad.
  
  509   Sun Jun 1 19:25:10 2008 ranaConfigurationComputersnew monitor on op440mI installed the new 24" flat screen on op440m.
I increased the screen resolution from 1280x1024
to 1900x1200 using
 Andrey-440.jpgBusby08.jpg 
  544   Wed Jun 18 18:50:09 2008 ranaUpdateComputersIt can only be attributable to human error. (HAL - 2001)[B]There has been another one of "those" events
and all of the front end machines are down.[/B]
  
  546   Thu Jun 19 20:22:03 2008 ranaUpdateGeneralFE Computer StatusI called Rolf (@LLO) who called Alex (@MIT)
who suggested that we power cycle every crate
  
  547   Fri Jun 20 01:38:55 2008 ranaUpdatePEM20 day WeatherYoichi showed me that its possible to make
PNG images from PS using GS:
 test.png 
  552   Mon Jun 23 15:22:04 2008 ranaBureaucracySAFETYLaser Safety Walkthrough today   Walkthrough08.jpg 
  560   Tue Jun 24 22:43:23 2008 ranaSummarySEIStack TF   Screenshot.png 
  570   Thu Jun 26 01:08:22 2008 ranaConfigurationGeneralAlarm Handler RevivedI have revived the Alarm Handler by turning
it on on op540m and adjusting the levels
of
 b.gif 
  571   Thu Jun 26 01:10:18 2008 ranaUpdatePEMAlarm Handler indicates that dust level is high[I]In its first useful act[/I], the Alarm
Handler started beeping indicating that the
[COLOR=purple]dust particle
 Untitled.png 
  576   Thu Jun 26 18:27:04 2008 ranaUpdateComputer Scripts / ProgramsNo Dataviewer No CryDataviewer was hanging. It would open the
Grace window but then not plot anything.
Since DTT was working
  
  578   Thu Jun 26 20:59:22 2008 ranaUpdateComputer Scripts / ProgramsAlarm Handler[COLOR=red][SIZE=5][B]Please do not turn off
the Alarm Handler on op540m.[/B][/SIZE][/COLOR]
  
  579   Thu Jun 26 21:07:11 2008 ranaConfigurationASSdust & MC1I realized today, that yesterday while we
were trying to debug the adaptive noise canceler,
I turned
 Screenshot-2.png 
  593   Sun Jun 29 18:58:43 2008 ranaSummaryComputers1e20 is too big for AWG and/or IOVMEWhile testing out my matlab/awgstream based
McWFS diagnostic script I accidentally put
a
  
  594   Sun Jun 29 19:19:47 2008 ranaSummaryIOOTrends of the PSL/IOO Quads over 1000 daysOnly IOO POS has been working for the past
2 years. I guess we should recommission the
IOO ANG and REFL QPDs
 a.png 
  597   Sun Jun 29 20:29:48 2008 ranaUpdatePSLCorrelation of PSL SLOW control v. Room temperature   slowtemp.png 
  662   Sat Jul 12 23:28:31 2008 ranaUpdatePSLPMC needs helpAs everyone has noticed recently, the PMC
seems to have a PZT problem. It often zooms
 Untitled.png 
  663   Sun Jul 13 17:19:29 2008 ranaSummaryPSLMOPA SLOWM CalibrationJohn, Rana

We first unlocked the FSS and ramped the
 SLOWDCcalibration.png 
  676   Tue Jul 15 19:15:57 2008 ranaSummarySUSETMX Dewhitening characterizationSince the boys found that the ETM dewhitening
transient was kicking the IFO out of lock
we
 etmx-dw-transient.pdf 
  713   Tue Jul 22 11:55:22 2008 ranaUpdatePSLNote from R. Abbott re: the PMCan email from Rich:
[CODE]Your PZT is broken.
  
  718   Tue Jul 22 22:25:31 2008 ranaUpdateLSCLooptickle for existing 40mJohn and I have adapted the Stefan-Looptickle
model of the 40m upgrade to have the parameters
of the old one.
 nb.png 
  719   Wed Jul 23 01:42:26 2008 ranaConfigurationPSLFSS RFPD: Examined, "repaired", and re-installed[U]Rob said that there might be something
wrong with the FSS RFPD since the loop gain
is so low.[/U]
 Untitled.pdf 
  736   Thu Jul 24 21:04:58 2008 ranaUpdatePSLFSSSince Jenne and Yoichi are going to finish
up their refcav/FSS work in the morning I
decided to
  
  737   Thu Jul 24 21:53:00 2008 ranaSummaryTreasureHigh School Tour group and the PMCThere was a tour today of 40 high school kids.
[COLOR=red]I warned them that the lasers
could burn out their
  
  743   Sun Jul 27 20:25:49 2008 ranaConfigurationEnvironmentOffice Temperature increased to 75 FSince we have the chiller for the PSL chiller
now, [SIZE=2][COLOR=darkred]I've just increased
the office area 
  
  744   Sun Jul 27 20:49:21 2008 ranaConfigurationComputersNTPAfter Aidan did whatever he did on op440m,
I had to restart ntpd. I noticed it didn't
actually do
  
  745   Sun Jul 27 23:06:17 2008 ranaUpdatePSLPMC, MZ, MC-MMT, etc.With the new PMC now in I aligned the MZ to
the new beam (there is sadly no steering
between the PMC and the MZ). 
  
  749   Mon Jul 28 17:44:07 2008 ranaUpdatePSLPMC PZT v. temperatureThis plot shows that the PMC [COLOR=darkblue]PZT
has ~20 Vpp fluctuations on a 24 hour timescale[/COLOR]
which is correlated to the 24 hour temperature
 Untitled.pdf 
  755   Tue Jul 29 13:54:08 2008 ranaUpdateSUSETMY and PRM have EQ related problemsThe attached trend shows that ETMY and PRM
both had large steps in their sensors
around the time of the EQ and didn't return
 Untitled.png 
  762   Wed Jul 30 00:42:04 2008 ranaUpdateSUSTrends and file formatsI propose that we do not use .eps format but
.pdf instead. For images like the plots Sharon
has below we should use only .png and for
 Untitled.png 
  763   Wed Jul 30 01:08:50 2008 ranaSummarySUSSUS Drift ScreenThis is a snap of the SUS Drift screen with
all of the optics biases set back to their
nominal
 infection-2.png 
  770   Wed Jul 30 15:12:08 2008 ranaSummaryIOOHistory of the MC abs length> I was notified by Rob and Rana that there
were many measurements of the MC abs length
(i.e. modulation 
  
  773   Wed Jul 30 18:45:01 2008 ranaConfigurationSUSNew SUS Drift TechnologyI updated the SUS DRIFT screen again, this
time with a new feature.
  
  775   Thu Jul 31 10:27:17 2008 ranaUpdatePSLPMC Scan Graphs[quote]Graphs of the PMC scan data that I
got earlier today. 
[/quote]
  
  778   Fri Aug 1 01:13:32 2008 ranaConfigurationPSLPSL Quad change and new scriptKoji and I changed a few optics so that now
~60% of the beam that went to the PSL POS
QPD
  
  781   Fri Aug 1 16:33:52 2008 ranaConfigurationPSLPSL Quad change and new scriptHere's the sensor ringdown trend from the
kick.
 Untitled.png 
  784   Sat Aug 2 16:05:38 2008 ranaConfigurationComputer Scripts / ProgramsmDV updateI did an [B]svn update on our mDV[/B] directory.
Justin has improved it so that the NDS client
binaries
  
  785   Sat Aug 2 18:37:41 2008 ranaUpdateSUSOSEM Spectra[COLOR=darkblue]
The attached PDF file is from the .xml files
that I found from 7/30. Looks like someone
 free_080730.pdf 
  786   Sun Aug 3 20:53:54 2008 ranaConfigurationPEMGuralpWe got our repaired Guralp back in the mail
from England (s/n T4157). I plugged it in
to Ben's 3-Guralp breakout box (http://www.ligo.caltech.edu/docs/D/D060506-00.pdf)
  
  808   Thu Aug 7 10:27:59 2008 ranaUpdateSUSFree swinging OSEM spectraSometimes we see extra peaks in the OSEM spectra
coming from a beat between the regular eigenmodes.
This probably comes from the OSEM shadow
  
  812   Fri Aug 8 09:54:10 2008 ranaUpdateCamerasNew code + gstreamer allows for easy saving and compression of images[quote]Modified the CamSnap code to output
the image data stream to standard out.  This
can then be piped into a gstreamer plugin
  
  819   Sun Aug 10 16:57:02 2008 ranaSummaryPhotosPhotos from Vent 8/4 - 8/8http://www.ligo.caltech.edu/~rana/40m/VentAug08/

I've added the D40 pictures from last week
  
  820   Mon Aug 11 00:58:31 2008 ranaUpdatePEM2 years of temperature trendThe PSL RMTEMP alarmed again because it says
the room temperature is 19.5 C. Steve said
in
 Untitled.png 
  821   Mon Aug 11 09:39:29 2008 ranaUpdatePEM2 years of temperature trendSteve and I went around and inspected and
then adjusted the thermostats and [FONT=Comic
Sans MS]humidostats[/FONT].
  
  867   Thu Aug 21 17:55:14 2008 ranaHowToIOOMC WFS DC OffsetsI ran the McWFS_dc_offsets script to trim
out the DC offsets on the MC WFS DC signals.
  
ELOG V3.1.3-