  7187   Wed Aug 15 04:03:55 2012 ranaSummaryLSCY-Arm Locking0) Did a bunch of alignment to get beams
roughly centered on ETMY and ITMY and maximize
power. Adjusted the aperture and focus on
 yArmNoise_120815.pngyarm.pdf 
  5937   Fri Nov 18 00:36:23 2011 ZachUpdateGreen LockingY-Arm PDH box modifiedI modified the Y-Arm PDH box (S/N 17)  pdh17_tf_vs_liso_11_17_11.png 
  5956   Sat Nov 19 00:47:24 2011 ZachUpdateGreen LockingY-Arm locked with PDH Box #17I installed the newly modified PDH  error_sig_m_11_18_11.png 
  12188   Thu Jun 16 11:25:00 2016 JohannesUpdateLSCY-Arm round-trip loss measurement with ALSUsing the ALS green beat and armlength
feedback I mapped an IR resonance of the
Y-Arm by stepping through a ramp of offset
 T_vs_steps.pdff_vs_steps.pdf 
  4435   Wed Mar 23 19:16:17 2011 AidanSummaryGreen LockingY-END green equipment is all availableWith the exception of a 2" mirror
mount, I've confirmed that we have everything
for the Y-end green production and mode-matching.
 three-quarter_inch_pedestal.jpg 
  4436   Thu Mar 24 01:16:19 2011 SureshSummaryGreen LockingY-END green equipment is all availableThere was a 2" mirror mount among the spares
on the PSL table.  It has a window LW-3-2050
UV mounted in it.  I
  
  9232   Fri Oct 11 00:37:21 2013 MasayukiUpdateGreen LockingY-arm ALS [Manasa, Masayuki]
-
Motivation
 OLTF.pdfERR.pdf 
  9240   Tue Oct 15 01:39:07 2013 MasayukiUpdateGreen LockingY-arm ALS  
 - Motivation
 PDHinloop.pdfALSinloop.pdf 
  14738   Tue Jul 9 18:06:05 2019 gautamUpdateLSCY-arm ASS in a workable stateThe Y-arm ASS was tuned to be in a workable
state. Basically, I followed Koji's recipe.
 ditherFreqs.pdftransRenorm.png 
  9054   Thu Aug 22 20:25:28 2013 MasayukiSummaryGreen LockingY-arm PDH OLTF measurement[Manasa, Masayuki]
We measured the the openloop transfer
function of the PDH green lock of the y-arm.The
 OLTF_PDH_Glock_yarm_7.png 
  12884   Mon Mar 13 16:47:41 2017 SteveUpdatePEMY-arm air conditon belts replacedThe east end AC unit is arching over and
running rough at CES. Called for mechanic.......

Both belts were replaced and the
  
  13048   Wed Jun 7 14:11:49 2017 gautamUpdateASSY-arm coil driver electronics investigationRana suggested taking a look at the Y-arm
test mass actuator TFs (measured by driving
the coils one at a time, with only local
 CoilTFs.pdfY_OL_calib_check.png 
  13051   Wed Jun 7 17:45:11 2017 gautamUpdateASSY-arm coil driver electronics investigationI repeated the test of driving C1:SUS-<Optic>_<coil>_EXC
individually and measuring
 CoilTFs.pdf 
  13052   Thu Jun 8 02:11:28 2017 gautamUpdateASSY-arm coil driver electronics investigation
p.p1
{margin: 0.0px 0.0px 0.0px 0.0px; font: 18.0px
'Helvetica Neue'; -webkit-text-stroke: #000000}
p.p3
 AnalogCheck.pdfAnalogCheck_zoom.pdfArmCtrl.pdf 
  9164   Thu Sep 26 10:55:29 2013 SteveUpdateGeneralY-arm floor space for testLiyuon will set up a  ~5 mW He/Ne
laser for  waist measurement
  
  11879   Mon Dec 14 16:27:11 2015 gautamUpdateGreen LockingY-end AUX PDH noise breakdownSummary:

I've
attached the results from my measurements
 YAUX_NB_Dec2015.pdfPDH_errSig_Calib.pdf 
  11907   Mon Jan 4 16:45:11 2016 gautamUpdateGreen LockingY-end AUX PDH noise breakdownSummary:

I've
re-measured the noise breakdown for the Y-end
 ErrSigBreakdown.pdfcontrolSigBreakdown.pdfYEnd_PDH_OLTF.pdf 
  8817   Wed Jul 10 01:27:44 2013 gautamUpdateGreen LockingY-end Green PDH open-loop transfer function [Annalisa, gautam]
Summary:
We have measured the open-loop transfer
 Green_PDH_measurement.pdfY-end_Green_PDH.pdf 
  14943   Sat Oct 5 21:26:34 2019 gautamUpdateALSY-end green alignment tweakedSummary:

I improved the alignment of the
green beam into the Y arm cavity.
 ALSY_alignment.pngALSY_OOL.pdf 
  4994   Wed Jul 20 06:17:04 2011 SureshUpdateGreen LockingY-end green laser power issuesThe Y-end green beam power is 0.47 mW.
While
aligning the Y-end aux laser light into the
fiber we noticed that the green power out
 Y-end_table_powers.pdfY-end_table.png 
  14230   Thu Oct 4 22:15:30 2018 yukiConfigurationASCY-end table upgradeBefore changing setup at Y-end table, I
measured the status value of the former setup
as follows. These values will be compared
 AUXYGreenLock20180921.jpgPic_FormerSetup.jpegPic_CurrentSetup1004.jpg 
  14231   Fri Oct 5 00:46:17 2018 KojiConfigurationASCY-end table upgrade???

The SHG crystal has the conversion
efficiency of ~2%W (i.e. if you have 1W input
  
  14232   Fri Oct 5 17:32:38 2018 yukiConfigurationASCY-end table upgradeI measured it with the wrong setting of
a powermeter. The correct ones are here:


beam power going into doubling
  
  14233   Fri Oct 5 17:47:55 2018 gautamConfigurationASCY-end table upgradeWhat
about just copying the Xend
  
  14234   Fri Oct 5 22:49:22 2018 yukiConfigurationASCY-end table upgradeI designed a new layout. It has good mode-matching
efficiency, reasonable sensitivity to component
positions, good Gouy phase separation. I'm
  
  14237   Mon Oct 8 00:46:35 2018 yukiConfigurationASCY-end table upgrade


Quote:


  
  5625   Thu Oct 6 15:37:26 2011 JenneUpdateGreen LockingY-green Mech Shutter Button[Katrin, Jenne]
We were poking around and tried to
make a button for the Y-green shutter, just
  
  5181   Thu Aug 11 02:16:57 2011 JenneUpdateGreen LockingY-green aligned and flashing[Jenne, with ample supervision by Kiwamu
and Suresh]
Y-green was aligned, and is now flashing. 
  
  6234   Fri Jan 27 16:55:28 2012 JenneUpdateGreen LockingY-green realignedThe Yarm green laser really wanted to lock
on a 01/10 mode, so Kiwamu suggested I go
inside and realign the green beam to the
  
  7764   Fri Nov 30 02:40:44 2012 DenUpdateAdaptive FilteringYARMI've applied FIR adaptive filter to YARM
control. Feedback signal of the closed loop
was used as adaptive filter error signal
 yarm_oaf.png 
  7767   Fri Nov 30 11:49:24 2012 KojiUpdateAdaptive FilteringYARMThis is interesting. I suppose you are
acting on the ETMY.
Can you construct the compensation
  
  8552   Wed May 8 18:33:02 2013 KojiUpdateASSYARM ASS - faster and more precise convergencePrecise arm alignment is more demanded.
as the PRMI locking requires good and reliable
alignment of the ITMs.
 YARM_ASS.pngScreenshot.png 
  7211   Fri Aug 17 00:16:30 2012 EricSummaryLSCYARM CalibrationI modified my Simulink model of the YARM
to match the new filter modules Rana installed
on YARM. I also scaled the open loop transfer
 olg_model_meas.pnglength_response_model.pngyarm_uncal_power_spec.pdfyarm_cal_power_spec.pdf 
  7128   Thu Aug 9 00:14:02 2012 EricSummaryLockingYARM Locking and CalibrationToday I spent time locking the YARM
in order to calibrate the arm cavity. Here's
 cal_swept_sine3_tfmagcal_swept_sine3_tfphcal_swept_sine3_cohsensing_func_model.png 
  7130   Thu Aug 9 00:35:53 2012 JenneSummaryLockingYARM Locking and Calibration

    

       
            
  
  7134   Thu Aug 9 10:09:32 2012 EricSummaryLockingYARM Locking and Calibration

    

       
            
 cal_swept_sine3_magnitude.pdfcal_swept_sine3_phase.pdfcal_swept_sine3_coherence.pdf 
  7139   Fri Aug 10 09:51:51 2012 EricSummaryLockingYARM Locking and MeasurementsI forgot to post this last night, but I
locked the YARM again yesterday and misaligned
the other optics. I took measurements on
  
  5742   Wed Oct 26 11:35:08 2011 KatrinUpdateGreen LockingYARM PDH box   PDH_w_wo_jump.png 
  5726   Fri Oct 21 16:59:14 2011 KatrinUpdateGreen LockingYARM PDH box brokenI could not improve the locking. So, I
checked the transfer function of the PDH
box again. The transfer function looks okay
  
  17140   Thu Sep 15 11:13:32 2022 AnchalSummaryASSYARM and XARM ASS restoredWith limited proof of working for a few
times (but robustly), I'm happy to report
that ASS on YARM and XARM is working now.
  
  11504   Thu Aug 13 23:57:33 2015 IgnacioUpdateLSCYARM coherence plotsI took data
from 1123495750 to 1123498750 GPS
time (Aug 13 at 3AM, 50 mins of data) for
 YARM_psd.pngYARM_GUR1_COH.pngYARM_STS_COH.pngYARM_GUR1_COH.png 
  5846   Wed Nov 9 12:05:08 2011 KatrinUpdateGreen LockingYARM error signal and feedback signalerror signal = signal measured behind the
low-pass filter
feedback signal = output of the gain
 fluctuation_test.png 
  5837   Mon Nov 7 17:38:18 2011 KatrinUpdateGreen LockingYARM length fluctuation   fluctuation.pngfluctuation_length.pngfluctuation_Hz_length.png 
  5769   Mon Oct 31 14:01:56 2011 KatrinUpdateGreen LockingYARM locks for 2hToday, I could lock the YARM laser for
2h to the YARM cavity. After to hours the
output of the servo is saturated. I need
 7x 
  12524   Thu Sep 29 20:21:29 2016 JohannesUpdateGeneralYARM loss measurement[Gautam, Johannes]

I scripted a series of YARM DC
reflectivity measurements last night alternating
  
  11472   Thu Jul 30 19:12:52 2015 IgnacioUpdateIOOYAW and PIT WFS Wiener filteringRana pointed out that another way to mitigate
seismic motion at in the mode cleaner would
be to look at the YAW and PITCH output  channels
 YAW.pngPIT.png 
  12175   Tue Jun 14 11:29:25 2016 JohannesSummaryASCYArm OpLev CalibrationIn preparation for the armloss map I checked
the calibration of the Y-Arm ITM and ETM
OpLevs with the method originally described
 CavityCoupling.pdf 
  7643   Wed Oct 31 01:06:31 2012 DenUpdateAlignmentYarm 
 Jenne, Den
We looked at beam spots on ITMY and
  
  8276   Tue Mar 12 00:58:05 2013 ManasaUpdateAlignmentYarm - Spot positions centered[Jenne, Manasa]

  
  6155   Fri Dec 30 02:16:48 2011 kiwamuUpdateGreen LockingYarm ALS : high frequency noise reducedThe
high frequency noise, which has been a dominant
noise above 30 Hz in the Y arm ALS (
 Yarm_ALS_2011Dec29.png 