  1915   Mon Aug 17 02:05:49 2009 Yoichi,ranaUpdatePSLReference cavity reflection looks badRana, Yoichi

It has been a well known fact that the reference
 P8170113.JPGUntitled.png 
  1917   Mon Aug 17 04:16:13 2009 YoichiUpdatePSLReference cavity reflection looks bad[quote]Rana, Yoichi
- We also moved the Refcav reflection camera
to look at the leakage through a reflection
  
  1922   Tue Aug 18 01:16:01 2009 JenneUpdatePSLMach Zehnder is realignedThe Mach Zehnder and I got to know each
other today.  The reason for redoing
the alignment was to improve pointing from
 MachZehnderOptics2.pdf 
  1923   Tue Aug 18 14:24:43 2009 YoichiSummaryPSLReference Cavity InspectionRana, Koji, Yoichi

To see why the reflected beam from the RC
  
  1925   Tue Aug 18 15:52:27 2009 JenneUpdatePSLMZI tweaked up the MZ alignment. 
The reflection had been around 0.550, which
kept the MEDM indicator green, but was still
  
  1926   Tue Aug 18 19:57:47 2009 rana, JenneUpdatePSLMZ- we finished the MZ alignment; the contrast
is good.
- we did the RFAM tuning using a
 MZ_RFAMmon_setup_small.jpgMZ_RFAMmon_SpecAnalyzer_small.jpgMZ_EOM_IRrefl2_small.jpg 
  1942   Tue Aug 25 11:02:39 2009 ranaSummaryPSLTemperature BoxThe PSL Temperature Box (D980400-B-C, what
kind of numbering scheme is that?) modified
at LHO/LLO ~8 years ago to have better resolution
 D980400-B.pdf 
  1943   Tue Aug 25 18:42:42 2009 steveUpdatePSLreference cavity temp box temporarly out of order


   
        
            
  
  1945   Tue Aug 25 21:36:28 2009 AlbertoUpdatePSLreference cavity temp box temporarly out of order 
 Is that the reason of the PSL
craziness tonight? See attachment.
 2009-08-25_PSLtrend.png 
  1946   Tue Aug 25 21:55:11 2009 ranaUpdatePSLreference cavity temp box temporarly out of orderThere's no elog entry about what work has
gone on today, but it looks like Peter took
apart the reference cavity temperature control
 Untitled.pngrc-heater.jpg 
  1948   Wed Aug 26 14:45:14 2009 steveUpdatePSLPSL-FSS_RCTEMP of 4 yearsThe reference cavity vacuum chamber temp
is plotted starting Feb 22 of 2005
This plot suggest that the MINCO
 refcavtemp.jpg 
  1949   Wed Aug 26 15:42:17 2009 AlbertoUpdatePSLreference cavity temp box temporarly out of order

    
        
  
  1950   Wed Aug 26 16:10:28 2009 Peter KingConfigurationPSLPSL reference cavity temperature box modificationsThe 40m Lab reference cavity temperature
box S/N BDL3002 was modified as per DCN D010238-00-C.
These were:
 DSC_0731.jpg 
  1951   Wed Aug 26 16:11:41 2009 AlbertoUpdatePSLreference cavity temp box temporarly out of orderIt turned out that half an hour was too
long. In less than that the reference cavity
temperature passed the critical point when
  
  1952   Wed Aug 26 16:31:34 2009 steveUpdatePSLreference cavity temp box temporarly out of order


   
        
            
  
  1953   Wed Aug 26 16:35:03 2009 AlbertoConfigurationPSLPSL reference cavity temperature box modificationsBasically, in addition to the replacement
of the resistors with metal film ones, Peter
replaced the chip that provides a voltage
  
  1954   Wed Aug 26 19:58:14 2009 Rana, AlbertoUpdatePSLReference Cavity Temperature Control: MINCO PID removedSummary: This afternoon we managed
to get the temperature control of the reference
cavity working again.
 rc.png 
  1956   Thu Aug 27 13:42:08 2009 ranaSummaryPSLReference Cavity Temperature Control: psl.db changesI made the changes
to the psl.db to handle the new Temperature
  
  1957   Thu Aug 27 14:00:33 2009 ranaUpdatePSLRC thermal servo impulse responseI stepped the TIDALSET and looked at
what happened. Loop was closed with the very
 Untitled.png 
  1968   Mon Sep 7 20:05:18 2009 ranaUpdatePSLRCTEMP v. RMTEMPSince ~Aug. 27, the reference cavity has
been running with no thermal control. This
is not really a problem at the 40m; a 1 deg
 rct2.pngrct.png 
  1970   Mon Sep 7 23:35:03 2009 ranaUpdatePSLRC thermal servo: PID script modified, database + screen addedI have added the records for the RC thermal
PID servo into the psl/slowpid.db file which
also holds the records for the SLOW servo
 Untitled.png 
  1972   Tue Sep 8 12:26:16 2009 AlbertoUpdatePSLConnection of the RC heater's power supply replacedI
have replaced the temporary clamps that were
connecting the RC heater to its power supply
  
  1976   Tue Sep 8 19:30:33 2009 ranaUpdatePSLc1psl rebooted for new RCPID database settingsThe RC thermal PID is now controllable
from its own MEDM screen which is reachable
from the FSS screen. The slowpid.db and
 c1psl-term-dump.txt.gzC1PSL_FSS_RCPID.pngPicture_1.png 
  1978   Tue Sep 8 20:15:33 2009 rana, jenneSummaryPSLRC temperature servo: Heater Voltage noiseWe measured the voltage noise of the
heater used to control the RC can temperature.
It is large.
 09080901.PDFTEK00074.PNG 
  1983   Thu Sep 10 18:25:15 2009 ranaUpdatePSLc1psl rebooted for new RCPID database settingsI added a new database record (C1:PSL-FSS_RCPID_SETPOINT)
to allow for changing of the RC setpoint
while the loop is on. This will enable us
  
  1986   Sat Sep 12 15:40:15 2009 ranaUpdatePSLRC response v. can temperatureI stepped the RC can temperature  Picture_2.pngUntitled.pdf 
  1991   Fri Sep 18 14:25:00 2009 robOmnistructurePSLwater under the laser chillerrob, koji, steve
We noticed some water (about a cup)
on the floor under the NESLAB chiller today. 
  
  1992   Fri Sep 18 16:05:08 2009 JenneOmnistructurePSLwater under the laser chiller

    
        
  
  1993   Fri Sep 18 16:26:02 2009 steveSummaryPSLNeslab chiller is OKRob found puddles of water very close to
the chiller during lunch time. We raised
the unit and took the side cover off. All
  
  1995   Wed Sep 23 19:36:41 2009 ranaUpdatePSLRC temperature performanceThis first plot shows the RC temperature
channels' performance from 40 days ago, before
we disabled the MINCO PID controller. Although
 Untitled.pngUntitled.pnge.png 
  2008   Sun Sep 27 14:45:45 2009 KojiUpdatePSLSLOWscan resultI ran (script dir)/PSL/FSS/SLOWscan on
op440m from 11:30 to 12:30 on 27th. Although
Rana and later I myself set "timed bombs"
 SLOWscan_090927.pngPages_from_miser_126_manual.png 
  2009   Sun Sep 27 15:25:58 2009 KojiUpdatePSLSLOWscan resultOh, AMPMON dependence could be an artifact
of the ND filter???
For my case, it should be real dependence
 power_dependence.png 
  2010   Sun Sep 27 23:21:14 2009 ranaUpdatePSLSLOWscan result

    
        
  
  2013   Mon Sep 28 17:39:34 2009 robUpdatePSLproblemsThe PSL/IOO combo has not been behaving
responsibly recently. 
The first attachment is a 15 day
 problems.pngproblems2.png 
  2033   Thu Oct 1 10:23:00 2009 steveUpdatePSLMC2 damping restored again The EQ did not change the input beam
pointing. All back to normal, except MC2
wachdogs tripped again.
 mc2again.jpg 
  2049   Mon Oct 5 09:31:05 2009 AlbertoFrogsPSLPSL laser accidentally turned offAlberto, Steve,
While I was moving a cart near by
the PSL table I pushed the red emergency
  
  2050   Mon Oct 5 10:41:31 2009 KojiUpdatePSLPSL laser accidentally turned offThe PSL output looks smaller than the incident.
Try to FSS Slow actuator adj of -5.6 (nominal),
instead of -3.5.
  
  2051   Mon Oct 5 13:43:37 2009 ZachUpdatePSLPSL table photosI have been commissioned to take pictures
of the PSL table so that it can be diagrammed.
I am starting now (1:42 pm, 10/5/09).
  
  2052   Mon Oct 5 14:18:41 2009 ZachUpdatePSLPSL table photos

    
  
  2055   Mon Oct 5 19:39:26 2009 KojiUpdatePSLPSL laser accidentally turned offI set the FSS slow actuator adj to -5.6
at the lunch time. It gave a little help
at that time.  Now max of the MC Trans is
  
  2057   Tue Oct 6 10:09:55 2009 ZachUpdatePSLMore picturesI'm back to terrorize the PSL table again.
The pictures I took yesterday were rubbish--today
I'm using a clamp that Steve was nice enough
  
  2083   Mon Oct 12 18:37:55 2009 ZachUpdatePSLInventory--Apologies for the late post--
I was at the PSL table taking an
inventory of the components for a while after
  
  2088   Mon Oct 12 22:15:15 2009 ranaConfigurationPSLStray beam blockingYou can remove the RFAM measuring setup.
Once we upgrade, we will no longer have a
MZ or the related problems. 
  
  2089   Tue Oct 13 10:31:11 2009 ZachUpdatePSLone more timeI am at the PSL table taking what is hopefully
the last set of pictures for the diagram.
Woohoo.
  
  2090   Tue Oct 13 10:50:58 2009 ZachUpdatePSLone more time

    
  
  2098   Thu Oct 15 12:35:09 2009 ZachUpdatePSLinventoryI'm at the PSL table taking inventory of
the elements I don't have down yet.
  
  2099   Thu Oct 15 12:57:23 2009 ZachUpdatePSLinventory

    
        
  
  2142   Mon Oct 26 15:40:01 2009 steveUpdatePSLlaser power is down The laser power is down 5-6%  laserpowerdown.jpg 
  2147   Mon Oct 26 23:14:08 2009 KojiUpdatePSLlaser power is down I adjusted the steerings to the PMC and
gained 7%. Now the MC_TRANS 7.0 has been
recovered.
 PSL091026.png 
  2151   Tue Oct 27 18:01:49 2009 robUpdatePSLhmmmA 30-day trend of the PCDRIVE from the
FSS.
 pcdrive_trend.png 
ELOG V3.1.3-