  15164   Tue Jan 28 15:39:04 2020 gautamConfigurationComputersSluggish megatron?There were a bunch of medm processes stalled
on megatron (connected with screenshot taking).
To see if they were interfering with the
  
  15167   Tue Jan 28 17:36:45 2020 gautamConfigurationComputersLocal EPICS7.0 installed on megatron[Jon, gautam]

We found that the caput
  
  15246   Wed Mar 4 11:10:47 2020 YehonathanUpdateComputersAllegra revivalAllegra had no network cable and no mouse.
We found Allegra'snetwork cable (black)
and connected it.
  
  15276   Fri Mar 13 20:00:50 2020 JonUpdateComputersLoopback monitoring for slow machinesSummary

Today
I finished implementing loopback monitors
of the up/down state of the slow controls
 Screen_Shot_2020-03-13_at_7.59.55_PM.png 
  15447   Wed Jul 1 18:16:09 2020 gautamUpdateComputersrossa re-re-revivalIn an effort to make a second usable workstation,
I did the following (remotely) on rossa today
(not necessarily in this order, I wasn't
 MCacc.pdf 
  15449   Sun Jul 5 16:14:41 2020 ranaUpdateComputersrossa re-re-revivalmaybe we should make a "dd" copy
of pianosa in case rossa has issues
and someone destroys pianosa by accidentally
  
  15451   Sun Jul 5 18:39:57 2020 ranaUpdateComputersrossa: printerI did

sudo usermod -a -G
  
  15452   Mon Jul 6 00:37:28 2020 gautamUpdateComputersrossa: lib symlinkThis is strange - I was definitely able
to launch medm when I was working on this
machine remotely on Friday. But now, there
  
  15454   Mon Jul 6 12:43:02 2020 ranaUpdateComputersrossa: lib symlinkyes, I rebooted yesterday to fix the 'steaking
white lines' problem in the video/display

maybe we're supposed to edit
  
  15455   Mon Jul 6 12:51:41 2020 gautamUpdateComputersrossa: resolvconf installedIndeed, this is now fixed by following
instructions from here.
I rebooted rossa at ~1250 PDT and confirmed
  
  15460   Wed Jul 8 22:50:33 2020 gautamUpdateComputersrossa: more symlinksI wanted to try using rossa as my locking
workstation today. However, a few problems
became quickly evident. Basically, any of
  
  15463   Thu Jul 9 16:16:20 2020 gautamUpdateComputersrossa: graphics driver issues?I noticed these streaky lines again today
(but they were not a problem last night).
It is annoying if we have to reboot this
  
  15469   Sat Jul 11 00:10:22 2020 gautamUpdateComputersrossa: more developmental workAfter some consultation with Erik von Reis
at LHO, this workstation is progressing towards
being usable
  
  15473   Mon Jul 13 11:33:18 2020 ranaUpdateComputersrossa: more developmental workI too, would prefer py3 for everything,
but aren't all the cdsutils / gaurdian
things still python2?
  
  15475   Mon Jul 13 12:37:05 2020 gautamUpdateComputersrossa: more developmental workIn fact, all these utilities are now available
in python3. There may be some bugs (e.g.
this),
  
  15921   Mon Mar 15 20:40:01 2021 ranaConfigurationComputersinstalled QTgrace on donatella for dataviewerI installed QTgrace using yum on donatella. Both Grace and  cutiegrace.png 
  15928   Wed Mar 17 09:05:01 2021 Paco, AnchalConfigurationComputers40m Control Room Changes
Switched positions of allegra and
donatella.
While doing so, the
hdmi cable previously used by donatella snapped.
  
  15945   Fri Mar 19 15:26:19 2021 AidanUpdateComputersActivated MATLAB license on megatronActivated MATLAB license on megatron   
  15946   Fri Mar 19 15:31:56 2021 AidanUpdateComputersActivated MATLAB license on donatellaActivated MATLAB license on donatella   
  15955   Tue Mar 23 09:16:42 2021 Paco, AnchalUpdateComputersPower cycled C1PSL; restored C1PSLSo actually, it was the C1PSL channels
that had died. We did the following to get
them back:
 MCWFS1and2PITYAW.pdfMCWFS1and2PITYAW_Zoomed.pdf 
  16027   Wed Apr 14 13:16:20 2021 AnchalConfigurationComputers40m Control Room Changes
I have confirmed that the old two
monitors' backlighting is not working.
One can see the impression of the display
  
  16249   Fri Jul 16 16:26:50 2021 gautamUpdateComputersDocker installed on nodusI wanted to try hosting some docker images
on a "private" server, so I installed
Docker on nodus following the instructions
  
  16287   Mon Aug 23 10:17:21 2021 PacoSummaryComputerssystem reboot glitch[paco]

At 09:34 PST I noted a glitch in
the controls room as the machines went down
  
  16307   Thu Sep 2 17:53:15 2021 PacoSummaryComputerschiara down, vac interlock tripped[paco, koji, tega, ian]

Today in the morning the name server
/ network file system running in chiara failed.
  
  16312   Thu Sep 2 21:21:14 2021 KojiSummaryComputersVacuum recovery 2Attachment 1:
We are pumping the main volume with
TP2. Once P1a reached the pressure ~2.2mtorr,
 Screenshot_2021-09-02_21-20-24.pngScreenshot_2021-09-02_21-20-48.png 
  16313   Thu Sep 2 21:49:03 2021 PacoSummaryComputerschiara down, vac interlock tripped[tega, paco]

We found the files that took excess
space in the chiara filesystem (see Attachment
 2021-09-02_21-51-15.png 
  16314   Fri Sep 3 02:03:15 2021 TegaSummaryComputersStrip down large error filesAlso deleted the ~50GB error files from
ldas to prevent rsync from copying them
to nodus again. With the new update to GWsumm,
  
  16346   Mon Sep 20 15:23:08 2021 YehonathanUpdateComputersWifi internet fixedOver the weekend and today, the wifi was
acting bad with frequent disconnections and
no internet access. I tried to log into the
  
  16348   Mon Sep 20 15:42:44 2021 Ian MacMillanSummaryComputersQuantization Code SummaryThis post serves as a summary and description
of code
to run to test the impacts of quantization
 472px-Typical_State_Space_model.svg.pngBiquad_filter_DF-IIx.svg.pngSS-IIR-TF.pdf 
  16350   Mon Sep 20 21:56:07 2021 KojiUpdateComputersWifi internet fixedUg, factory resets... Caltech IMSS announced
that there was an intermittent network service
due to maintenance between Sept 19 and 20.
  
  16355   Wed Sep 22 14:22:35 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryNow that we have a model of how the SS
and IIR filters work we can get to the problem
of how to measure the quantization noise
 IIR64-bitnoisespectrum.pdf 
  16360   Mon Sep 27 12:12:15 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI have not been able to figure out a way
to make the system that Aaron and I talked
about. I'm not even sure it is possible
  
  16361   Mon Sep 27 16:03:15 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI have coded up the procedure in the previous
post: The result does not look like what
I would expect. 
 DeltaNoiseSpectrum.pdf 
  16362   Mon Sep 27 17:04:43 2021 ranaSummaryComputersQuantization Noise Calculation SummaryI suggest that you


change the corner frequency
to 10 Hz as I suggested last week. This filter,
  
  16366   Thu Sep 30 11:46:33 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryFirst and foremost I have the updated bode
plot with the mode moved to 10 Hz. See Attachment
1. Note that the comparison measurement is
 SS-IIR-Bode.pdfPSD_32bit.pdfPSD_64bit.pdf 
  16481   Wed Nov 24 11:02:23 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI added mpmath
to the quantization noise code. mpmath allows
me to specify the precision that I am using
 PSD_IIR_all.pdf 
  16482   Wed Nov 24 13:44:19 2021 ranaSummaryComputersQuantization Noise Calculation SummaryThis looks great. I think what we want
to see mainly is just the noise in the 32
bit IIR filtering subtracted from the 64
  
  16492   Tue Dec 7 10:55:25 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation Summary[Ian, Tega]

Tega and I have gone through the
IIR
 DF2_TS.pdfBIQ_TS.pdfScreen_Shot_2021-12-07_at_11.47.57_AM.pngPSD_COMP_BIQ_DF2.pdfPSD_COMP_SS_DF2.pdf 
  16498   Fri Dec 10 13:02:47 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI am trying to replicate the simulation
done by Matt Evans in his
presentation  (see Attachment
 G0900928-v1_(dragged).pdfPSD_COMP_BIQ_DF2.pdfInput_PSD.pdfInput_Filter.pdfQuantizationN.zip 
  16507   Wed Dec 15 13:57:59 2021 PacoUpdateComputersupgraded ubuntu on zita[Paco]

Upgraded zita's ubuntu and
restarted the striptool script.
  
  16650   Mon Feb 7 16:14:37 2022 TegaUpdateComputersrealtime system reboot problemI was looking into plotting temperature
sensor data trend and why we currently do
not have frame data written to file (on /frames)
  
  16656   Thu Feb 10 14:39:31 2022 KojiSummaryComputersNetwork security issue resolved[Mike P / Koji / Tega / Anchal]

IMSS/LIGO IT notified us that "ILOM
ports" of one of our hosts on the "114"
 PXL_20220210_220816955.jpgPXL_20220210_220827167.jpg 
  16836   Mon May 9 15:32:14 2022 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI made the first pass at a tool to measure
the quantization noise of specific filters
in the 40m system. The code for which can
 SUS-ETMX_SUSYAW3_0.0.pdfLowNoiseBiquad2.pdfquant_noise_floor.pdf 
  16881   Fri May 27 17:46:48 2022 PacoSummaryComputersCDS upgrade visit, downfall and rise of c1lsc models[Paco, Anchal-remote, Yuta, JC]

Sometime around noon today, right
after cds upgrade planning tour, c1lsc FE
  
  16991   Tue Jul 12 13:59:12 2022 ranaSummaryComputersprocess monitoring: MonitI've installed Monit
on megatron and nodus just now, and will
set it up to monitor some of our common processes.
  
  17058   Thu Aug 4 19:01:59 2022 TegaUpdateComputersFront-end machine in supermicro boxesKoji and JC looked around the lab today
and found some supermicro boxes which I was
told to look into to see if they have any
 IMG_20220804_184444473.jpgIMG_20220804_191658206.jpgIMG_20220804_185336240.jpgIMG_20220804_185023002.jpg 
  17066   Mon Aug 8 17:16:51 2022 TegaUpdateComputersFront-end machine setupAdded 3 FE machines - c1ioo, c1lsc, c1sus
-  to the teststand following the instructions
in elog15947.
 IMG_20220808_170349717.jpg 
  17074   Wed Aug 10 20:51:14 2022 TegaUpdateComputersCDS upgrade Front-end machine setupHere is a summary of what needs doing following
the chat with Jamie today.

 
 IMG_20220810_171002928.jpgIMG_20220810_171019633.jpg 
  17083   Tue Aug 16 18:22:59 2022 TegaUpdateComputersc1teststand rack mounting for CDS upgrade[Tega, Yuta]

I keep getting confused about the
purpose of the teststand. The view I am adopting
 IMG_20220816_180157132.jpgIMG_20220816_175125874.jpg 
  17088   Wed Aug 17 11:10:51 2022 ranaUpdateComputersc1teststand rack mounting for CDS upgradewe want to be able to run SimPlant on the
teststand, test our new controls algorithms,
test watchdogs, and any other software upgrades.
  