40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 260 of 341  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  4094   Thu Dec 23 13:30:09 2010 steveConfigurationVACslow pumpdown completeThe pump down continued this morning by
the removal of the butterfly valve. Two roughing
pumps were used to reach 500 mTorr
 slow2dpd.jpg 
  4093   Thu Dec 23 12:19:43 2010 kiwamuUpdateGreen Lockinginstalled doubling oven base at PSL tableI
gave a christmas present to a doubling oven
who has been sitting on the PSL table.
 DSC_2820_ss.jpgDSC_2814_ss.jpgDSC_2815_ss.jpg 
  4092   Thu Dec 23 08:54:32 2010 SureshUpdateelogthe delhi univ syndromeSorry folks!  I couldnt get to the
elog and didnt know that the elog was crashing
every time I tried to access it. 
  
  4091   Thu Dec 23 03:15:11 2010 KojiUpdateelogelogd is getting killed by SureshELOG has crashed and I restarted it.
Actually the filtering is not effective
so far as elog is not using apache but has
  
  4090   Wed Dec 22 21:38:47 2010 kiwamuConfigurationVACRe:slow pumpdown at 12 hoursI stopped the pumping at 9:30 pm. Now
we are at 29 torr.

  
  4089   Wed Dec 22 17:24:50 2010 steveConfigurationVACslow pumpdown at 12 hoursWe have reached 200 Torr at 12 hours of
slow pumping speed. Kiwamu stopped the pumping
for 11 hrs last night .and I restarted it
 slowpd12h.jpg 
  4088   Wed Dec 22 15:47:22 2010 KojiUpdateVACTank closing procedure[Jenne Kiwamu Joe Osamu Steve Koji]
Yesterday (21st), we closed the BSC
and the four testmass chambers.
  
  4087   Wed Dec 22 15:30:47 2010 OsamuUpdateASCETMY oplev fixedAccording to c1scy.mdl, OL signals should
be connected to adc_0_24 to adc_0_27 but
they were connected to adc_0_16 to adc_0_19
  
  4086   Wed Dec 22 11:24:23 2010 haixingUpdateSUSmeasurement of imbalance in quadrant maglev protopeYesterday, a sequence of force and gain
measurement was made to determine the imbalance
in the
 config_2x2.png 
  4085   Wed Dec 22 06:50:19 2010 ranaUpdateelogelogd is getting killed by SureshAfter another elog crash, I've blacklisted
the domain that Suresh is using by editing
the apache httpd.conf. Let's see what happens
  
  4084   Tue Dec 21 16:34:42 2010 kiwamuSummaryVACAll the test masses have been wiped [Jenne and Kiwamu]
 We wiped all the test masses with
  
  4083   Tue Dec 21 16:20:09 2010 steveConfigurationVACpumpdown has startedSlow pumpdown of   
  4082   Tue Dec 21 11:52:58 2010 josephbUpdateComputersRGA scripts fixed, c0rga fixedc0rga apparently had a full hard drive. 
There was 1 Gig log file in /var/log directory,
called Xorg.0.log.old which I deleted which
  
  4081   Tue Dec 21 08:26:08 2010 ranaUpdateelogelogd is getting killed by SureshSuresh killed the elogd again from India.
This was the log file:
Accept-Charset: ISO-8859-1,utf-8;q=0.7,*;q=0.7
  
  4080   Mon Dec 20 23:32:58 2010 kiwamuUpdateIOORe:checking out & closing the vacuum chambers    
  4079   Mon Dec 20 23:10:25 2010 JenneUpdateSUSPretty much ready for pump-down. A few final things....[Kiwamu, Jenne, Koji, Osamu]
We have mostly prepared the IFO for
pump down. 
  
  4078   Mon Dec 20 22:56:20 2010 JenneUpdateIOOPlan for closing the vacuum chambersTuesday 

    If still everythig is
fine, put the BS heavy door.

-
  
  4077   Mon Dec 20 16:57:58 2010 steveUpdateIOOchecking out & closing the vacuum chambers
    Check EQ-stops
  
  4076   Mon Dec 20 10:47:29 2010 KojiUpdateIOOPlan for closing the vacuum chambersMonday

    Place the bars on the
  
  4075   Mon Dec 20 10:06:36 2010 kiwamuUpdateCDSETMY damped  Last Saturday
I succeeded in damping the ETMY suspension
 2010Dec18.png 
  4074   Sun Dec 19 22:45:28 2010 ranaUpdateelogrestartedI deleted the yellow box which showed up
by default when making an elog entry. Would
be nice if we could make it so that you have
  
  4073   Sun Dec 19 11:19:42 2010 KojiUpdateelogrestartedDid it again. It seemed that Google bot
came to the elog and tried to obtain  "http://nodus.ligo.caltech.edu:8080/robots.txt".
That was the last of the log.
  
  4072   Sat Dec 18 23:33:06 2010 KojiUpdateelogrestartedDid the same.

  
  4071   Sat Dec 18 06:24:49 2010 ranaUpdateelogrestartedThe process was taking up 100% of the CPU
and not responding via web. The .log file
showed the last action was somebody reading/editing
  
  4070   Sat Dec 18 01:17:04 2010 kiwamuUpdateIOOsome more alignments [Koji and Kiwamu]
 We did some more vacuum
works today. It is getting ready to pump
  
  4069   Fri Dec 17 03:37:47 2010 ranaUpdateSUSITMY / SRM / BS / PRM OPLEVs aligned

    
        
  
  4068   Fri Dec 17 02:22:06 2010 kiwamuUpdateCDSETMY damping: not good  I made some efforts
in order to damp ETMY, however it still doesn't
  
  4067   Fri Dec 17 00:55:30 2010 KojiUpdateIOOThe dark port beams reached the AP table[Koji and Kiwamu]
We
obtained two dark port beams on the AP table:
  
  4066   Fri Dec 17 00:30:05 2010 KojiUpdateIOOITMY / SRM / BS / PRM OPLEVs aligned[Steve and Koji]
The
invac OPLEV mirrros were aligned
  
  4065   Thu Dec 16 15:10:18 2010 josephb, kiwamuUpdateCDSETMY working at the expense of ETMXI acquired
a second full pair of Host interface board
cards (one for the computer and one for the
  
  4064   Thu Dec 16 10:52:42 2010 josephbUpdateCamerasNew PoE digital camerasWe have two new Basler acA640-100gm cameras. 
These are power over ethernet (PoE) and very
tiny.
 basler.jpg 
  4063   Thu Dec 16 01:23:43 2010 kiwamuUpdateSUSSRM OSEMs installed  [Zach and Kiwamu]
 We worked
 DSC_2757_ss.jpg 
  4062   Wed Dec 15 23:10:40 2010 KojiUpdateIOOSRM Oplev / Dark Steering mirrors installedI helped the vacuum installation work in
the evening.
- Three steering mirrors after the
  
  4061   Wed Dec 15 18:29:59 2010 JenneUpdatePEMSeismometer Channels Being Recorded AgainThe Seismometer channels are once more
being recorded.  Alastair brought Gur1
back from the ATF the other day, and today
  
  4060   Wed Dec 15 17:21:20 2010 josephbUpdateCDSETMY controls statusStatus:
The
c1iscey was converted over to be a diskless
  
  4059   Wed Dec 15 16:04:49 2010 steveConfigurationVACvacuum valves found in default conditionThis condition is created when we run out
of nitrogen that holds the valves in set
positions. The Maglev and other turbos are
  
  4058   Wed Dec 15 14:23:32 2010 KojiUpdateCDSETMY IO chassis updateGreat!

I wish this board works fine at least for
several days...
  
  4057   Wed Dec 15 13:36:44 2010 josephbUpdateCDSETMY IO chassis updateI gave
Alex a sob story over lunch about having
to go and try to resurrect dead VME crates. 
  
  4056   Wed Dec 15 12:46:18 2010 KojiSummaryIOOFinishing up the vac workWhat else?
v: Edit on Dec 15 10PM
  
  4055   Tue Dec 14 22:42:56 2010 kiwamuUpdateSUSinstalled the last TT . And some more progresses  [Koji, Oasmu and Kiwamu]
 
  
  4054   Tue Dec 14 15:15:19 2010 kiwamuUpdateSUSput ETMY and aligned the beam  [Zach and Kiwamu]
 We
  
  4053   Tue Dec 14 11:24:35 2010 josephbUpdateCDSburt restoreI had
updated the individual start scripts, but
forgotten to update the rc.local file on
  
  4052   Tue Dec 14 09:26:17 2010 ZachUpdateelogrestarted Restarted the elog with the script   
  4051   Tue Dec 14 04:14:53 2010 ranaUpdateElectronicsRF Photodiode CharacterizationsThis is looking better, but the fit data
for the TF should be plotted along with the
data. The data should be made up of points
  
  4050   Tue Dec 14 01:04:23 2010 kiwamuUpdateSUSalignment of ITMs and PRM done   The alignment of the ITMs   
  4049   Mon Dec 13 22:21:41 2010 kiwamuSummarySUSfunny output matrix of ETMX: solved !I found that
a few connections in the simulink model of
  
  4048   Mon Dec 13 21:03:30 2010 KevinUpdateElectronicsRF Photodiode Characterizations[Koji, Jenne, Kevin]
Jenne worked on fixing REFL11 last
week (see elog 4034)
  
  4047   Mon Dec 13 18:06:43 2010 JenneUpdateSUSETMY resuspended, ready to install. Tip Tilt realigned, ready to install.[Koji, Jenne]
I wish I could use a bigger font
for this, but, 
 StatusTable.png 
  4046   Mon Dec 13 17:18:47 2010 josephbUpdateCDSBurt updatesProblem:
Autoburt wouldn't
restore settings for front ends on reboot
  
  4045   Mon Dec 13 11:56:32 2010 josephb, alexUpdateCDSDolphin is workingProblem:
The dolphin RFM was not sending
data between c1lsc and c1sus.
  
ELOG V3.1.3-