40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 255 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  13939   Mon Jun 11 13:55:33 2018 keerthanaUpdateGeneralProject UpdatesAs of now, I have made the codes needed
to sweep the marconi frequency for taking
the cavity scan data, the photo diode at
  
  13943   Mon Jun 11 19:16:49 2018 keerthanaUpdateelogComparison of the analytical and finesse values of TMS and FSR.The percentage error which I found out
=[(analytical value - finesse value)/analytical
value]*100
 fitting_1.pdf 
  13945   Mon Jun 11 22:18:18 2018 keerthanaUpdateelogComparison of the analytical and finesse values of TMS and FSR.Oopss !! I made a mistake while taking
the values from my notes. Sorry.

  
  13954   Wed Jun 13 11:59:03 2018 keerthanaUpdateelogcommand line enabled code for frequency scanningI have modified the code for frequency
scanning and have made it completely command
line enabled. The code is written in python.
  
  13956   Wed Jun 13 18:08:36 2018 keerthanaUpdate Finesse code for cavity scanThe unit mentioned in the x-axis was wrong.
So I have remade the graphs. The point where
frequency equals to zero is actually the
 finesse1.pdffinesse2.pdf 
  13995   Thu Jun 21 13:24:00 2018 keerthanaUpdateelogThe cavity scan data of June 20(Jon, Keerthana, Sandrine)

We tried to align the AUX and PSL
laser yesterday. We collected the data from
 AS110_Beat.pdfYEND_Beat.pdf 
  14017   Tue Jun 26 10:06:39 2018 keerthanaUpdateAUXFirst Coherent AUX Scan of PRC Using AM Sidebands(Jon, Keerthana, Sandrine)

I am attaching the plots of the
Reflected and transmitted AUX beam. In the
 TRANS.pdfREFL.pdf 
  14045   Sun Jul 8 22:27:25 2018 keerthanaUpdate AUX diagram(Analisa, Keerthana, Sandrine)

So far we tried four different
techniques to scan the AUX laser. They are,
 PLL-single_demodulation.pdfPLL-double_demodulation.pdf 
  Draft   Wed Jul 11 18:13:19 2018 keerthanaSummaryAUXGouy Phase Measurements from AUX-Laser ScansFrom the Measurement Jon made, FSR is 3.967
MHz and the Gouy phase is 52 degrees. From
this, the length of the Y-arm cavity
  
  14057   Thu Jul 12 14:06:39 2018 keerthanaUpdateelogFinesse and Analytical solution - ComparisonI tried to compare the cavity scan data
we get from the Finesse simulation and that
we expect from the Analytical solution. The
 finesse_cavity.pngAnalytical1.pdfFinesse_Analytical.pdfDifference.pdf 
  13938   Mon Jun 11 11:45:13 2018 keerthana UpdateelogComparison of the analytical and finesse values of TMS and FSR.


Quantity
 finesse1.pdf 
  14039   Thu Jul 5 17:33:36 2018 keerthana, sandrineUpdateelogLights not working
N/S ARM FL.
N/S ARM
INC.


These two lights inside
the 40m-lab are not working.
  
  14040   Thu Jul 5 17:58:04 2018 keerthana, sandrineUpdateelog (Analisa, Sandrine, Keerthana)

Today Annalisa helped us to understand
the new set up used to make the frequency
 setup1.jpgsetup2.jpg 
  6360   Mon Mar 5 23:47:15 2012 keikoConfigurationLSCND2 at REFL OSAND filter ND3 (which is at the   
  6361   Tue Mar 6 00:13:20 2012 keikoUpdateLSCASI signal offset   Screenshot-Untitled_Window.png 
  6368   Tue Mar 6 23:37:31 2012 keikoUpdateSUSMICH noise budget - SUS checkHere are the OSEM spectrum of MICH suspensions
(BS, IX, IY). Bounce and Roll modes are shown
on 16 and 23 Hz. The filters for them has
 6x 
  6375   Wed Mar 7 16:32:09 2012 keikoUpdateLSCOSA I swap an OSA at PSL and OSA at REFL.
It was because the PSL-OSA had a better resolution,
so we place this better one at REFL. The
  
  6376   Wed Mar 7 17:39:40 2012 keikoUpdateLSCMICH noise budget on 5 Mar This is the calibrated MICH noise
budget on Mar 5. There was a sharp peak at
1Hz and a blob on 3 Hz. The demod phase was
 Mar5-MICHbudget.pngMar5-MICHbudget.png 
  6380   Wed Mar 7 20:53:13 2012 keikoUpdateLSCMICH noise budget on 5 Mar 
 
 Mar6-MICHbudget.png 
  6384   Wed Mar 7 23:29:28 2012 keikoUpdateLSCREFL OSA observation kiwamu, keiko
 
 
 REFLOSA.png 
  6385   Thu Mar 8 00:57:48 2012 keikoUpdateLSCMICH noise budget on Mar 5, Mar 6, and oldHere is the recent two noise budgets of
MICH, with the old measurement by Jenne.
The most latest Mar 6 data is quite close
 Mar7MICHbudgettotal.png 
  6393   Fri Mar 9 13:34:13 2012 keikoUpdateLSCupdate on the locking activityWe tried to measure the sensing matrix
for MICH and PRCL last night. They look too
much mixed as we expect... the matrix may
  
  6398   Sat Mar 10 02:00:03 2012 keikoUpdateLSCupdate on the locking activityITMX and ITMY balance for the MICH excitation
(lockin) is adjusted again. Now it's ITMx
= -0.992, ITMy = 1 for MICH (lockin output
  
  6400   Mon Mar 12 01:04:18 2012 keikoUpdateLSCRAM simulation update, RAM LSC matrix I calculated the DRMI RAM LSC
matrix with RAM and the operation point offsets.

    configuration: C1 DRMI
  
  6401   Mon Mar 12 18:57:58 2012 keikoUpdateLSCRAM simulation update, RAM LSC matrix

    

       
            
  
  6417   Wed Mar 14 16:33:20 2012 keikoUpdateLSCRAM simulation / RAM pollution plotIn the last post, I showed that SRCL element
in the MICH sensor (AS55I-mich) is chaned
1% due to RAM.
 Mar14pollution.pngRAMexampleplot.png 
  6419   Wed Mar 14 21:01:36 2012 keikoUpdateLSCevolution of the sensing matrix in PRMI as a function of timeThis is the simulated signals
to compare with the original post #6403
  
  6449   Tue Mar 27 02:18:31 2012 keikoUpdateIOOBeam Profile measurement: IPPOS beamKeiko, Rana, Suresh
Related to the beam profile of IPPOS
today, we tried to measure the beam size
 text9149.pngfirst_cap.pngsecond_cap.pngtext9149.png 
  6452   Tue Mar 27 16:06:59 2012 keikoUpdateIOOBeam Profile measurement: IPPOS beamI changed the ETMY CCD camera angle
so that we can see the suspension frame in
order to repeat the same thing as yesterday.
  
  6458   Tue Mar 27 21:37:51 2012 keikoConfigurationIOOBeam Profile measurement: IPPOS beam From the mode measurement I and Suresh
have done yesterday, I calculated what beam
size we expect at ETM ((1) upper Fig.1)  and
 9x 
  6464   Thu Mar 29 11:29:27 2012 keikoUpdateLSCPOP22/POP110 amplifiresYesterday I and Kiwamu connected two amplifiers
(mini-circuit, ZFL-1000LNB+) for POP22/110.
Dataviewer can see some signals. I'll test
  
  6466   Thu Mar 29 18:42:11 2012 keikoUpdateLSCPOP22/POP110 amplifiresAdding two amplifiers on POP22/110,
I checked the signals going to the dmod board
of 22 and 110.
 P3290004.JPGP3290005.JPG 
  6475   Mon Apr 2 18:24:34 2012 keikoUpdateLSCRAM simulation for Full ifo I extended my RAM script from DRMI
(3DoF) to the full IFO (5DoF).
Again, it calculates the operation
  
  6480   Tue Apr 3 14:11:33 2012 keikoUpdateLSCRAM simulation for Full ifo

    

       
            
  
  6481   Tue Apr 3 14:17:18 2012 keikoUpdateLSCRAM simulation for Full ifoI add a flow-chart drawing what the scripts
do and how the scripts calculate the LSC
matrix.
 flowchart.png 
  6482   Tue Apr 3 15:50:58 2012 keikoUpdateLSCRAM simulation for Full ifoOops,
Yesterday's results for DARM was wrong!
  
  6483   Tue Apr 3 22:50:37 2012 keikoUpdateLSCRAM simulation for Full ifoKoji and
Jamie suggested me to include the coupling
between DoFs when I calculate the last matrix.
  
  6486   Wed Apr 4 23:57:35 2012 keikoUpdateLSCRAM simulation for Full ifo I'm still wondering whether iteration
version or simple version is closer approximation
to the real situation. Sorry for few explanations
  
  6504   Sat Apr 7 00:31:12 2012 keikoUpdateLSCRAM simulation for Full ifoI didn't
understand how CARM can be decreased 2 orderes
of magnitude and PRCL can be INCREASED by
 plot4a.pngplot4b.png 
  2064   Wed Oct 7 11:18:40 2009 kiwamuSummaryElectronicsracks of electronics 
I took the pictures of all racks
of electronics yesterday, and then uploaded
  
  2111   Sun Oct 18 22:05:40 2009 kiwamuUpdateLSCLSC timing issueToday
I made a measurement to research the LSC
timitng issue as mentioned on 
 rough.pngdetail.png 
  2114   Mon Oct 19 10:00:52 2009 kiwamuUpdateLSCRE: LSC timing issueOf course I know there is a downconversion
in OMC signal from 32k to 16k.
But I was just wondering if the delay
  
  2122   Mon Oct 19 23:14:32 2009 kiwamuUpdateLSCLSC timing issueI measured
the noise spectrum of LSC_DARM_IN1 and OMC-LSC_DRIVE_EXC
by using DTT,
 SPE20Hz.pngSPE200Hz.pngSPE2kHz.png 
  2145   Mon Oct 26 18:49:18 2009 kiwamuUpdateLSCOMC-LSC timing issueAccording to my measurements I
conclude that LSC-signal is retarded from
 exp1.pngexp2.pngOMC_LSC60sec.png 
  2146   Mon Oct 26 19:12:50 2009 kiwamuUpdateLSCdiagnostic script for LSC timingThe diagnostic script I've written is available
in the 'caltech/users/kiwamu/work/20091026_OMC-LSC-diag/src'.
To run the script, you can just execute
  
  2153   Tue Oct 27 19:37:03 2009 kiwamuUpdateLSCcron job to diagnose LSC-timingI set a cron job on allegra.martian to
run the
diagnostic script every weekend.
  
  2167   Mon Nov 2 10:56:09 2009 kiwamuUpdateLSCcron job works succesfully & no timing jitterAs
I wrote on Oct.27th, the cron job works
every Sunday.
  
  2169   Mon Nov 2 13:34:36 2009 kiwamuConfigurationPSLremoved multiply resonant EOMI removed the multiply resonant EOM that
has been set by a SURF student from PSL table.
I will use it for checking the resonant
  
  2179   Thu Nov 5 12:34:26 2009 kiwamuUpdateComputerselog rebootedI found elog got crashed. I rebooted the
elog daemon just 10minutes before.
  
  2244   Wed Nov 11 20:57:06 2009 kiwamuUpdateElectronicsMulti-resonant EOM --- LC tank circuit ---I have been working about multi-resonant
EOM since last week.
In order to characterize the behavior
 DSCN0160.JPGLCtank_complete.png 
ELOG V3.1.3-