  16661   Thu Feb 10 21:10:43 2022 KojiUpdateGeneralVideo Mux setting resetNow the video matrix is responding correctly
and the web interface shows up. (Attachment
1)
 Screenshot_2022-02-10_21-11-21.pngScreenshot_2022-02-10_21-11-54.png 
  12694   Fri Jan 6 17:00:26 2017 ranaFrogsTreasureVideo of Lab TourIn this video: https://youtu.be/iphcyNWFD10,
the comments focus on the orange crocs, my
wrinkled shirt, and the first aid kit.
  
  7945   Mon Jan 28 17:01:19 2013 DenUpdateLockingVideo of PRM-flat test cavityWhat mode will you get if lock the cavity
PRM - ITMY/ITMX/TEST MIRROR without PR2,
PR3 and BS?
  
  7951   Tue Jan 29 10:50:02 2013 JenneUpdateLockingVideo of PRM-flat test cavity 
I think Den accidentally edited and
overwrote my entry, rather than replying,
  
  2314   Mon Nov 23 16:28:12 2009 steveSummaryCamerasVideo swicher options


   
        
            
  
  4498   Thu Apr 7 13:12:23 2011 KojiHowToVIDEOVideo switching tipLong time ago, I looked at the manual of
the video switcher. 
  
  4529   Fri Apr 15 02:30:24 2011 KojiHowToVIDEOVideo switching tipI have made a small python script to handle
the video matrix.
It is too far from the perfection,
  
  7839   Mon Dec 17 14:45:01 2012 JenneUpdateAlignmentVideos with PRMI locked[Jamie, Jenne]
Koji and Jamie locked the PRMI, and
then Jamie and I took some videos. 
  
  10394   Thu Aug 14 22:16:02 2014 JenneUpdateSUSViolin Mode filters for ETMsThe instigator of this was that we were
seeing ring-ups of ETMs during our ALS locks
this evening.  We measured the ETMY
  
  10393   Thu Aug 14 20:52:36 2014 ranaUpdateWikiViolin Mode table added to WikiMech
Resonance Wiki
I've updated the wiki by trawling
  
  9057   Fri Aug 23 01:52:34 2013 JenneUpdateSUSViolin filters moved to LSC, from SUS[Rana, Jenne]  MICHloopNotches_23Aug2013.pdf 
  9058   Fri Aug 23 14:19:28 2013 ranaUpdateSUSViolin filters moved to LSC, from SUS  Just to rephrase somewhat:

    We balance the BS & PRM actuators
  
  8620   Wed May 22 18:24:19 2013 JenneUpdateSUSViolin mode survey

    

       
            
  
  4991   Tue Jul 19 20:36:08 2011 ranaUpdateComputersVirtualBox + Windows 7 on rossaI installed Virtual Box on rossa. Then
I put Windows 7 in there and am now installing
Altium.
  
  7239   Tue Aug 21 00:35:25 2012 ranaSummaryIOOVisibilities and ChromeMC and PMC vis:  Untitled.pdf 
  13450   Wed Nov 22 17:52:25 2017 gautamUpdateOptimal ControlVisualizing cost functionsI've attempted to visualize the various
components of the cost function in the way
I've defined it for the current iteration
 globalCosts.pdf 
  3206   Tue Jul 13 13:56:29 2010 GopalConfigurationOptic StacksVitol Material PropertiesViton flouroelastomers have somewhat variable
material properties. The following parameters
are being used for eigenfrequency analysis.
  
  3222   Wed Jul 14 19:00:56 2010 GopalConfigurationOptic StacksVitol Material Properties, REVISED

    
        
  
  15084   Sun Dec 8 20:27:11 2019 ranaUpdateComputersViviana upgrade to Ubuntu 16The IBM laptop at EX was running Ubuntu
14, so I allowed it to start upgrading itself
to Ubuntu16 as it desired. After it is done,
  
  1713   Thu Jul 2 05:27:12 2009 ClaraUpdatePEMVoltage Divider OopsI tested the voltage dividers and was getting
up to about 3V. I retested the mic w/o the
voltage divider in place, and, lo and behold,
 voltage_divider_diagram.png 
  2288   Wed Nov 18 00:38:33 2009 ranaSummaryElectronicsVoltage Noise of the SR560's OUTPUTs (the back panel)I've
measured the voltage noise of the SR560's
lead acid battery outputs; they're not so
 sr560.png 
  8778   Thu Jun 27 23:18:46 2013 jamieUpdateComputer Scripts / ProgramsWARNING: Matlab upgraded

    

       
            
  
  4816   Tue Jun 14 12:23:44 2011 Jamie, JoeUpdateCDSWE ARE ALL GREEN! LSC back up and running in new configuration.After moving the c1lsc computer to 1X4,
then connecting c1lsc to it's IO chassis
in 1Y3 by a fiber PCIe extension cable, everything
  
  1313   Mon Feb 16 21:49:06 2009 Kakeru, RanaUpdateIOOWFSWe centerd the input of WFS QPD.   
  6066   Sun Dec 4 13:56:54 2011 DenUpdateIOOWFSYesterday I locked the MC and left at 8
pm. Analyzing the data I saw that MC was
locked all time from 8 pm to 12.30 am when
  
  6067   Sun Dec 4 23:49:38 2011 DenUpdateIOOWFS

    

       
            
  
  15266   Wed Mar 11 18:12:53 2020 gautamSummaryPSLWFS Demod board modifications[koji, gautam]

 D980233-B_Mar2020Mods.pdf 
  13936   Sun Jun 10 03:46:38 2018 KojiUpdateIOOWFS HEAD SW confusionI was checking on the slow machine channels
and found something I could not understand.

On the IOO WFS HEAD screen, there
 C1IOO_WFS_HEADS.png 
  13946   Mon Jun 11 22:46:24 2018 KojiUpdateIOOWFS HEAD SW confusionThe unfortunate discovery today was that
the attenuator switches on the IMC WFS heads
are actually assigned to individual segments,
 180611_IMC_WFS1.pdf180611_IMC_WFS2.pdf 
  13960   Thu Jun 14 00:46:09 2018 ranaUpdateIOOWFS HEAD SW confusionits painful, but you and I should probably
take these out, bypass the switches
and use them with fixed gain;
  
  5859   Wed Nov 9 21:48:43 2011 SureshUpdateIOOWFS Servo included into the MC_AutolockerThe WFS
servo loop will come on 5 seconds after the
MC is locked. 
  
  17258   Fri Nov 11 19:11:50 2022 JCUpdateGeneralWFS Whitening and Demod BoardsWFS Whitening and Demod boards were scavenged.
 IMG_6419.JPGIMG_6424.JPG 
  3182   Thu Jul 8 19:43:16 2010 nancyUpdateIOOWFS calculationsThe WFS error signals were recorded in
the order 
WFS1_PIT
  
  3184   Thu Jul 8 21:44:43 2010 nancyUpdateIOOWFS calculations 
I just found the singular values
and the condition number of the 4*4 matrix
  
  7444   Wed Sep 26 23:55:14 2012 JenneUpdateIOOWFS centeredSince the MC spots are good, I put the
beam back on WFS 1 and WFS 2.
Also, I changed the indicators on
  
  1358   Thu Mar 5 00:06:32 2009 Kakeru, RanaUpdateIOOWFS centeringWe found that the MC REFL image was no longer
round and that the MCWFS DC quadrant spots
were mostly
 IOO_graph.jpg 
  1391   Wed Mar 11 23:41:33 2009 Kakeru, YoichiUpdateIOOWFS centering We found the MC reflection was distorted
. And WFC beam went to upward of QPD
We recentered WFC beam and these
  
  15450   Sun Jul 5 18:25:42 2020 ranaUpdateElectronicsWFS characterizationin the lab, checkin on the WFS

Sun Jul 5 18:25:50 2020

I redid Gautam's measurements
 WFS_attenOff.pdf 
  15547   Sat Aug 29 20:07:48 2020 ranaUpdateElectronicsWFS characterizationI set up to do the WFS head modifications
today, but I was shot down in flames due
to a missing AC/DC adapter.
  
  15548   Sat Aug 29 22:10:09 2020 gautamUpdateElectronicsWFS characterizationClearly this "riff raff" is referring
to me. It won't help today I guess but
there is one each on the carts holding the
  
  15472   Sun Jul 12 22:40:35 2020 gautamUpdateElectronicsWFS characterization - old SURF reportAfter some hunting, I found this
old SURF report with the WFS head measurements.
The y-axes don't make much sense to me,
  
  8724   Wed Jun 19 15:07:20 2013 ranaUpdateIOOWFS debuggingTrying to figure out what's wrong with
the MC WFS:
1) The symptom seems to be that the
  
  8733   Thu Jun 20 15:15:39 2013 ranaUpdateIOOWFS debuggingTried a bunch of stuff, but eventually
just turned off the TRANS_QPD loops and loops
are stable. Needs more debugging. 
 Untitled.png 
  8815   Tue Jul 9 20:09:53 2013 KojiUpdateIOOWFS debuggingThe low UGFs of the MC WFS servos made
the MC insane thesedays: 
The servos are too slow and we kept
  
  9210   Sun Oct 6 23:43:07 2013 ranaUpdateIOOWFS debugging

    

       
            
  
  8735   Thu Jun 20 20:46:16 2013 gautamUpdateIOOWFS debugging-QPD debugging 
 I wanted to make sure that
the QPD map on the C1IOO_MC_TRANS_QPD.adl
 MC2_QPD-map.png 
  6660   Tue May 22 13:06:11 2012 JenneUpdateIOOWFS didn't turn off automaticallyI just sat down in the control room, and
discovered the PMC (and everything else)
unlocked.  I relocked the PMC, but the
  
  6669   Wed May 23 21:32:15 2012 SureshUpdateIOOWFS didn't turn off automatically

    

       
            
  
  5688   Tue Oct 18 21:19:18 2011 ranaConfigurationIOOWFS disabled in SUSI found that the MC WFS had large offset
control signals going to the MC SUS. Even
though the input switch was off, the integrators
  
  14858   Thu Sep 5 18:42:19 2019 aaronHowToCDSWFS discussion, restarting CDS[aaron, rana]

While going to take some transfer
functions of the MC WFS loop, LSC was down.
  
ELOG V3.1.3-