40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 254 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  3652   Tue Oct 5 16:30:00 2010 josephb, yutaHowToCDSScreen settings and medm screens for new systemYou can find the sitemap medm screen in
/opt/rtcds/caltech/c1/medm/master
The settings for the screens were
  
  3653   Tue Oct 5 16:58:41 2010 josephb, yutaUpdateCDSc1sus front end statusWe moved the filters for the mode cleaner
optics over from the C1SUS.txt file in /opt/rtcds/caltech/c1/chans/
to the C1MCS.txt file, and placed SUS_ on
  
  3658   Wed Oct 6 11:03:51 2010 josephb, yutaHowToCDSHow to start diaggui for right nowI'm hoping to get a proper install this
week done, but for now, this a stop gap.
To start diagnostic test tools, go
  
  3662   Wed Oct 6 16:16:48 2010 josephb, yutaUpdateCDSc1sus statusAt the moment, c1sus and c1mcs on the c1sus
machine seem to be dead in the water. 
At this point, it is unclear to me why.
  
  3666   Thu Oct 7 10:48:41 2010 josephb, yutaUpdateCDSc1sus statusThis
problem has been resolved.
Apparently during one of Alex's debugging
  
  3668   Thu Oct 7 14:57:52 2010 josephb, yutaUpdateCDSc1sus statusAround noon, Yuta and I were trying to
figure out why we were getting no signal
out to the mode cleaner coils.  It turns
  
  3706   Wed Oct 13 17:04:34 2010 josephb, yutaUpdateCDSburt restore now working with filter settingsPreviously, burt restoring was not setting
filters on and off, which was required us
to constantly go through all the filter banks
  
  3707   Wed Oct 13 17:12:33 2010 josephb, yutaUpdateCDSFilter name length problem found and fixedThe missing filter files for ULPOS, URPOS,
and so forth for the mode cleaner optics
was due to the length of the names of the
  
  3797   Wed Oct 27 15:38:19 2010 josephb, yutaUpdateCDSIO chassis with bad timing was taken back to DownsProblem:
The front end timing was not working
properly for 2 of the IO chassis.  They
  
  3821   Fri Oct 29 11:25:15 2010 josephb, yutaSummaryCDS[EMERGENCY] accidentally deleted daqdProblem:
Missing daqd file, i.e. the framebuilder
executable.
  
  3845   Tue Nov 2 13:51:40 2010 josephb, yutaUpdateCDSRFM slowdown problemProblem:
Each RFM memory location which needs
to be read by a front end model slows the
  
  3861   Thu Nov 4 15:27:33 2010 josephb, yutaUpdateCDSc1ioo test points not workingProblem:
We can't access any of the c1ioo
computer testpoints.  Dataviewer and
  
  3880   Mon Nov 8 14:30:15 2010 josephb, yutaUpdateCDSAdded LIGONDSIP setting to cshrc.40mWe added the following line to the cshrc.40m
file in the 64-bit linux and 32-bit linux
sections:
  
  3946   Thu Nov 18 14:05:06 2010 josephb, yutaUpdateCDSc1sus is alive!Problem:
We broke c1sus by moving ADC cards
around.
  
  3659   Wed Oct 6 12:00:23 2010 josephb, yuta, kiwamuUpdateCDSFound and fixed filter sampling rate problem with suspensionsWhile we looking using dtt and going over
the basics of its operation, we discovered
that the filter sample rates for the suspensions
  
  3911   Fri Nov 12 20:40:51 2010 josephb, yuta, valeraConfigurationElectronicsAA voltage rangeWe changed the range of the two SUS AA
boards in the corner from +/-2 V to +/-10
V by changing the supply voltage from +/-5
  
  1574   Mon May 11 12:25:03 2009 josephb,AlexUpdateComputersfb40m down for patchingThe 40m frame builder is currently being
patched to be able utilize the full 14 TB
of the new raid array (as opposed to being
  
  2212   Mon Nov 9 13:22:08 2009 josephb,alexUpdateComputersMegatron updateAlex and I took a look at megatron this
morning, and it was in the same state I left
it on Friday, with file system errors. 
  
  2967   Fri May 21 14:31:46 2010 josephb,alexUpdateCDSNew computer and IO chassis working in 1X4Alex brought over a ADC, DAC, and PCIe
card which goes into the computer and talk
to the IO chassis.  We tried installing
  
  3034   Wed Jun 2 11:25:16 2010 josephb,alexUpdateCDSCDS saga (aka the bad code saga)Alex updated the awg.par file to handle
all the testpoints.  Basically its very
similar to the testpoint.par, but the prognum
  
  3632   Fri Oct 1 10:56:30 2010 josephb,alexUpdateCDSfb work continuedAlex fixed the time issue with the IRIG-B
signal being far off, apparently their IRIG-B
signal in downs seems to be different. 
  
  2540   Thu Jan 21 17:23:30 2010 josephb,alex,kojiHowToComputersRCG code fixesIn order to see the Contec DO-32L-PE
Digital output PCIe card with the new
controls, we had to add the CDO32 part to
 CDO32.png 
  2695   Mon Mar 22 16:57:45 2010 josephb,daisuke, alexConfigurationComputersMegatron test points working againWe changed the pointer on /cvs/cds/caltech/target/gds/bin/awgtpman
from
/opt/gds/awgtpman    to
  
  3237   Fri Jul 16 15:57:19 2010 josephb,kiwamuUpdateComputersNew X end FE and IO chassis workWe finished setting up the new X end front
end machine (still temporarily called c1scx),
and attached it to its IO chassis. 
  
  3434   Wed Aug 18 12:24:58 2010 josephb,kiwamuUpdateCDSshmem issueApparently its possible to have working
models get into a bad state in regards to
shared memory, which prevents the model from
  
  3432   Wed Aug 18 11:40:59 2010 josephb,kiwamu,yoichiUpdateCDSEnd station working with latest RCG codeWe were able to get the latest SVN checkout
(revision 2009), working with the c1x00 (IOP)
and c1vgl models at the new X end on the
  
  2517   Fri Jan 15 18:53:05 2010 josephb,peter,kojiUpdateComputersAttempted locking with Megatron replacing ETMY front endThis afternoon we attempted to lock the
interferometer using Megatron insteady of
the usual ETMY front end.
  
  2911   Tue May 11 16:38:16 2010 josephb,rana,rolfUpdateCDSCDS questions and thoughts1) What is c1asc doing?  What is ascaux
used for?  What are the cables labeled
"C1:ASC_QPD" in the 1X2 rack really
  
  303   Fri Feb 8 17:55:53 2008 joshConfigurationPEMPEM-AS_MIC now in PSL enclosureI have moved the microphone to the PSL enclosure,
hanging near the south (Y) side from a support
rod for the overhanging storage area so that
  
  780   Fri Aug 1 11:51:15 2008 justingOmnistructureComputersadded /cvs/cds/site directoryI added a /cvs/cds/site directory.  This is
the same as is dicsussed [URL=http://ilog.ligo-la.caltech.edu/ilog/pub/ilog.cgi?group=detector&date_to_view=04/19/2008&anchor_to_scroll_to=2008:04:19:15:54:09-lisab]here[/URL].
 Right now it just has the text file 'cit'
  
  298   Tue Feb 5 17:39:05 2008 jweinerConfigurationPEMPEM-AS_MIC taken down from AS table, will put in PSL enclosure soonI took down the microphone that Andrey hung
above the AS table his first week in lab.
I want to hang the microphone above the PMC
  
  4772   Tue May 31 14:29:00 2011 jzweizigUpdateCDSframesThere seems to be something strange going
on with the 40m frame builder.
Specifically, there is a gap in the
  
  4407   Sun Mar 13 00:00:58 2011 jzweizig, ranaConfigurationDAQNDS2 code change and restart John has changed the NDS2 code and
restarted it on Mafalda. The issue is that
it goes off the rails everytime the DAQD
  
  10711   Thu Nov 13 22:52:48 2014 kateUpdatePEMSeismometers set up for huddle testJenne, Diego, Kate
We want to conduct a huddle test
with the three 40m seismometers (2 Guralps
 Seismic_13Nov2014.pdfseism_closed.jpgseism_open.jpg 
  13866   Fri May 18 19:10:48 2018 keerthanaUpdateGeneralCode for adjusting the oscillator frequency remotlyTarget: Phase locking
can be acheived by giving a scan to the oscilator
frequency. This frequency is now controlled
 frequency_set.jpg 
  13875   Mon May 21 18:02:55 2018 keerthanaUpdateGeneralTesting of the new mini-circuits frequency counterToday, I tested the new mini-circuit frequency
counter by connecting it with the beat signal
output. The frequency counter works fine.
 frequency_counter.jpg 
  13879   Tue May 22 17:29:27 2018 keerthanaUpdateelogMEDM Diagram for the auxilary laser system control and display.(keerthana, gautam, jon)

In the morning, Jon gave me an
overview of the Auxiliary laser system which
 MEDM_aux.png 
  13915   Mon Jun 4 19:41:01 2018 keerthanaUpdate Finesse code for cavity scanThe cavity scan data obtained from the
Finesse simulation is attached here. Fig1
indicates the cavity scan data in the absence
 Fig1.pngFig2.png 
  13924   Thu Jun 7 10:26:36 2018 keerthanaUpdatePSLobserving the resonance signal corresponding to the injected frequency.

(Johannes, Koji,
Keerthana)

The PLL loop ensures that the frequency
 photodetector_alignment.jpgdesign1.PNG 
  13926   Thu Jun 7 14:35:26 2018 keerthanaUpdateelogTable- useful for doing the scanning.I think this table will help us to fix
the scanning range of the Marconi frequency.
This will also help in predicting the position
  
  13939   Mon Jun 11 13:55:33 2018 keerthanaUpdateGeneralProject UpdatesAs of now, I have made the codes needed
to sweep the marconi frequency for taking
the cavity scan data, the photo diode at
  
  13943   Mon Jun 11 19:16:49 2018 keerthanaUpdateelogComparison of the analytical and finesse values of TMS and FSR.The percentage error which I found out
=[(analytical value - finesse value)/analytical
value]*100
 fitting_1.pdf 
  13945   Mon Jun 11 22:18:18 2018 keerthanaUpdateelogComparison of the analytical and finesse values of TMS and FSR.Oopss !! I made a mistake while taking
the values from my notes. Sorry.

  
  13954   Wed Jun 13 11:59:03 2018 keerthanaUpdateelogcommand line enabled code for frequency scanningI have modified the code for frequency
scanning and have made it completely command
line enabled. The code is written in python.
  
  13956   Wed Jun 13 18:08:36 2018 keerthanaUpdate Finesse code for cavity scanThe unit mentioned in the x-axis was wrong.
So I have remade the graphs. The point where
frequency equals to zero is actually the
 finesse1.pdffinesse2.pdf 
  13995   Thu Jun 21 13:24:00 2018 keerthanaUpdateelogThe cavity scan data of June 20(Jon, Keerthana, Sandrine)

We tried to align the AUX and PSL
laser yesterday. We collected the data from
 AS110_Beat.pdfYEND_Beat.pdf 
  14017   Tue Jun 26 10:06:39 2018 keerthanaUpdateAUXFirst Coherent AUX Scan of PRC Using AM Sidebands(Jon, Keerthana, Sandrine)

I am attaching the plots of the
Reflected and transmitted AUX beam. In the
 TRANS.pdfREFL.pdf 
  14045   Sun Jul 8 22:27:25 2018 keerthanaUpdate AUX diagram(Analisa, Keerthana, Sandrine)

So far we tried four different
techniques to scan the AUX laser. They are,
 PLL-single_demodulation.pdfPLL-double_demodulation.pdf 
  Draft   Wed Jul 11 18:13:19 2018 keerthanaSummaryAUXGouy Phase Measurements from AUX-Laser ScansFrom the Measurement Jon made, FSR is 3.967
MHz and the Gouy phase is 52 degrees. From
this, the length of the Y-arm cavity
  
  14057   Thu Jul 12 14:06:39 2018 keerthanaUpdateelogFinesse and Analytical solution - ComparisonI tried to compare the cavity scan data
we get from the Finesse simulation and that
we expect from the Analytical solution. The
 finesse_cavity.pngAnalytical1.pdfFinesse_Analytical.pdfDifference.pdf 
ELOG V3.1.3-