  11669   Tue Oct 6 03:30:17 2015 ericqUpdateLSCDRFPMI Progress[ericq, Gautam]

Highlight of the night: the DRFPMI
was held at arm powers > 110 for 20 seconds.
  
  11670   Tue Oct 6 16:56:40 2015 gautamUpdateGeneralFOL fiber box revamp[gautam, ericq]

We had a look at the IR beat (PSL+Xarm)
today using the new FOL fiber box, and compared
 20151006_Xbeat_psd.pdf20151006_Xbeat_coherence.pdf 
  11671   Thu Oct 8 04:48:50 2015 ericqUpdateLSCDRFPMI ProgressProgress was made. CARM was stably locked
on RF only. DARM was RF only for a few moments
before I typed in a wrong number...
  
  11672   Thu Oct 8 13:13:20 2015 KojiUpdateLSCDRFPMI ProgressPlease clarify: I wonder if you were at
the zero offset for CARM and DARM or not.
I am 25% excited right now.
  
  11673   Thu Oct 8 14:14:50 2015 ericqUpdateLSCDRFPMI Progress


  
  11674   Thu Oct 8 16:48:23 2015 KojiUpdateLSCDRFPMI ProgressAwesome   
  11675   Thu Oct 8 21:35:49 2015 ranaUpdateLSCDRFPMI ProgressGive us a lockloss or other kind of time
series plot so we can bask in the glory.
  
  11676   Fri Oct 9 09:22:38 2015 ericqUpdateLSCDRFPMI Progress   oct8_allRF.pdf 
  11677   Fri Oct 9 11:24:06 2015 JenneUpdateLSCDRFPMI ProgressI hope the grappa was already cold, and
ready to drink! 
  
  11678   Fri Oct 9 11:41:09 2015 ericqUpdateVACN2 Pressure fellAt 10:02AM, the N2 Pressure fell below
60 PSI. The watch script saw this happen,
but I did not recieve the email it is supposed
  
  11679   Fri Oct 9 13:31:21 2015 ericqUpdateLSCALS plant shapeTo get a better look at how to do fast
ALS, I took some "Plant TF"
measurements of the X arm. 
 xarm_plantTFs.pdf 
  11680   Fri Oct 9 14:50:18 2015 KojiUpdateLSCALS plant shapeALS is the comparison of the
PSL laser freq vs the
end laser freq that is locked to the arm
  
  11681   Fri Oct 9 16:23:25 2015 ericqUpdateLSCALS plant shapeAh, I understand it now! Since the additive
offset path keeps the post-cavity frequency
TF flat, the pre-cavity frequency must grow
  
  11682   Fri Oct 9 16:43:50 2015 ericqUpdateIOOWeird IMC behaviorA few minutes ago, Gautam and I were poking
around the IOO rack, looking at where he
should power his frequency divider box, and
 IMC_oddity.png 
  11683   Fri Oct 9 19:54:58 2015 gautamUpdateCDSFrequency divider box - installation in 1X2 rackThe new ZKL-1R5 RF amplifier that Steve
ordered arrived yesterday. I installed this
in the frequency divider box and did a quick
 IMG_0027.JPGtime_seris_25MHz.pdf 
  11684   Mon Oct 12 17:04:02 2015 gautamUpdateCDSFrequency divider box - further testsI carried out some more tests on the digital
frequency counting system today, mainly to
see if the actual performance mirrors the
 calibration.pdfsystematics.pdf 
  11685   Tue Oct 13 05:48:39 2015 ericqUpdateLSC:/[ericq, Gautam]

Despite our best efforts, the grappa
remains out of reach: the DRFPMI was not
  
  11686   Tue Oct 13 16:28:21 2015 ericqUpdateLSCFast ALS pomonaI've made a cascaded passive 2-pole
pomona box for fast ALS use, using LISO to
check that it'll give the right shape
 liso_lp.zip2LPfit.pdf 
  11687   Tue Oct 13 17:04:54 2015 ericqUpdateCDSCDS thingsAfter some discussion at last week's
40m meeting, I increased the frequency of
daqd trying to write out minute trends from
  
  11688   Wed Oct 14 15:59:06 2015 ranaUpdateComputer Scripts / Programsnodus web apache simlinks too softNone of the links here seem to work. I
forgot what the story is with our special
apache redirect 
  
  11689   Wed Oct 14 16:53:22 2015 KojiUpdateGeneralNon inverting buffer for SR560Eric needed a buffer to drive low input
impedance (~130Ohm) of his pomona box, I
quickly made a non-iverting buffer with G=+10.
 IMG_20151014_145608547.jpgIMG_20151014_145548751.jpg 
  11690   Wed Oct 14 17:40:50 2015 gautamUpdateCDSFrequency divider box - further testsSummary:

I carried out some further diagnostics
and found some ways in which I could optimize
 time_series_input_signals.pdfcalibration_20151012.pdfsystematics_20151012.pdf 
  11691   Thu Oct 15 03:08:57 2015 ericqUpdateLSCDRFPMI Locked for 20 sec[ericq, Gautam]

For real this time.

 DRFPMI_locked.pdf 
  11692   Thu Oct 15 04:14:14 2015 ericqUpdateLSCDRFPMI Locked for 20 secFast ALS was still a problem tonight. I
don't think high frequency ALS noise
saturating the PC drive is the issue; I put
  
  11693   Thu Oct 15 10:59:12 2015 KojiUpdateLSCDRFPMI Locked for 20 secGreat
job!
Many thanks Eric, Gautam, and all
  
  11694   Thu Oct 15 14:39:58 2015 ericqUpdateComputer Scripts / Programsnodus web apache simlinks too soft


  
  11695   Fri Oct 16 18:27:52 2015 SteveUpdateVAC vacuum normal conditionVacuum normal configuration with VM1-closed,
VM2-open valve positions. Power load normal
24V 0.2A
 oct16Fpm2015.png 
  11696   Sat Oct 17 18:55:07 2015 ranaUpdateLSCDRFPMI Locked for 20 sec in addition
to Koji's words I feel like we should
  
  11697   Mon Oct 19 11:20:34 2015 gautamUpdateVACRGA scan resetSteve pointed out that in the aftermath
of the Nitrogen running out a couple of times
last week, the RGA had shut itself off thinking
 RGAscan_151019.png 
  11698   Mon Oct 19 15:23:22 2015 ericqUpdateLSCLonger DRFPMI lockHere is a longer lock, about 100 seconds
RF only, from later that same night. The
in-loop CARM and DARM error signals have
 second_DRFPMI_15Oct2015.png 
  11699   Mon Oct 19 16:16:01 2015 ericqUpdateCDSC1ALS crashesGautam was working on his digital frequency
counter stuff when the c1als model crashed.
I had trouble bringing it back until I realized
  
  11700   Mon Oct 19 16:20:52 2015 ericqUpdateLSCGreen beatnote couplers installedLast Friday, I installed some RF couplers
on the green BBPDs' outputs, and sent
them over to Gautam's frequency divider
  
  11702   Tue Oct 20 15:51:44 2015 ericqUpdateSUSMC2 F2P tunedUsing a modified version of Hang's
deMod_deCoup scripts, I tuned the MC2 coil
output matrix to minimize the appearance
  
  11703   Tue Oct 20 16:27:04 2015 ericqUpdateVACvacuum VME machines rebooted[ericq, Gautam, Steve]

Following roughly the same procedure
as ELOG
  
  11704   Tue Oct 20 17:36:01 2015 gautamUpdateCDSFrequency counting with moving averageI'm working on setting up a moving-average
in the custom C code block that counts the
zero crossings to see if this approach is
  
  11705   Wed Oct 21 10:03:15 2015 SteveUpdateVACafter running out of N2 




 1d_after_reboot.png 
  11706   Wed Oct 21 15:42:56 2015 SteveUpdateVACvacuum gauge checkConvectron gauge check:

Brand new 10 years old convectron
gauge at atm was swapped into the place of
 Gauges.png 
  11707   Thu Oct 22 08:52:04 2015 SteveUpdateVACclean RGA scan after sweaty MaglevClean comparable scan at vacuum normal.
There was no backstreaming.
 clean_scan.png 
  11708   Fri Oct 23 09:55:50 2015 SteveUpdateLSCstable days   stable4days.png 
  11709   Fri Oct 23 18:36:48 2015 gautamUpdateCDSFrequency counting - workable setup preparedI've
made quite a few changes in the software
as well as the hardware of the digital frequency
 Yscan.pdf 
  11710   Fri Oct 23 19:27:19 2015 KojiUpdateCDSFrequency counting - workable setup preparedIt is a nice scan. I'm still thinking
about the equivalence of the moving average
and the FIR low pass that I have mentioned
  
  11711   Fri Oct 23 21:58:10 2015 ranaUpdateSUSMC2 F2P mis-tunedThe OSEMs cannot be used for coil balancing
above ~10 Hz. The main coupling path from
OSEM drive to sensor is not through the mirror
  
  11712   Sat Oct 24 12:34:43 2015 gautamUpdateCDSFrequency counting - workable setup preparedSorry for the confusion - I did mean Green
beat frequency, and I had neglected the
factor of 2 in my earlier calculations. However,
 Yscan.pdfFrequency_readout.pdf 
  11713   Mon Oct 26 18:10:38 2015 IgnacioUpdateIOOLast Wiener MCL subtractionsAs per Eric's request, here is the
code and TF measurement that was used to
calculate the MC2 FF filter that is loaded
 code_TF.zip 
  11714   Mon Oct 26 18:59:25 2015 gautamUpdateLSCGreen beatnote couplers installedI found
(an old) 10 dB coupler in the RF component
shelves near MC2 - it has BNC connectors
  
  11715   Mon Oct 26 19:10:59 2015 gautamUpdateGreen LockingAUX PDH loop characterizationI began my attempts to characterize the
PDH loops at the X end today. My goal was
to make the following measurements:
  
  11716   Tue Oct 27 03:46:26 2015 ericqUpdateSUSMC2 F2P mis-tunedD'oh. Good point.

Reverted for now; I'm thinking
about doing laser pointer->MC2 QPD...
  
  11718   Tue Oct 27 03:56:52 2015 ericqUpdateLSCDRFPMI workA handful of DRFPMI locks tonight, longest
one was ~7 minutes. 

EPICS/network latency has been
  
  11719   Tue Oct 27 10:08:12 2015 SteveUpdateVAC CC vacuum gaugesCC1 and CC2 are working again. Why did
they start working  again ?

 
 gauges_5y_vs_8d.png13.9yCC1&4.png 
  11720   Wed Oct 28 14:07:44 2015 KojiUpdateIOOMC WFS Offsets updateMC WFS offsets were updated to have a better
operating point.
 
  