Entry  Mon Mar 16 12:26:59 2009, Yoichi, Configuration, IOO, MC1 drift MC1_Drift1.pdf
    Reply  Tue Mar 17 08:44:37 2009, Yoichi, Configuration, IOO, MC1 drift MC1_Drift3.pdf
Entry  Thu Mar 19 02:45:36 2009, Yoichi, Configuration, IOO, A loose wire found for MC1  
    Reply  Thu Mar 19 10:45:43 2009, Yoichi, Configuration, IOO, A loose wire found for MC1  AfterWireFix-1.pdf
Entry  Fri Mar 20 11:01:02 2009, steve, Update, PEM, particle counts are high particles32d.jpg
Entry  Fri Mar 20 12:07:19 2009, Yoichi, Configuration, ASC, ETMY beam centering 
Entry  Fri Mar 20 15:54:29 2009, steve, Omnistructure, General, 480V crane power switch on MEZ 
Entry  Sun Mar 22 22:39:24 2009, rana, Summary, LSC, Calibration of the ITM and ETM Actuation free.png
Entry  Mon Mar 9 19:33:10 2009, rana, Update, DMF, seisBLRMS in temp condition Untitled.png
    Reply  Fri Mar 13 19:26:09 2009, Yoichi, Update, DMF, seisBLRMS compiled 
       Reply  Sun Mar 22 22:47:58 2009, rana, Update, DMF, seisBLRMS compiled but still dying 
Entry  Mon Mar 9 23:55:38 2009, Osamu, DAQ, Computers, bscteststand and kami1 outside martian 
    Reply  Sun Mar 22 23:16:41 2009, rana, DAQ, Computer Scripts / Programs, tpman restart 
Entry  Mon Mar 23 15:50:44 2009, rana, Configuration, LSC, filters deleted, lsc rebooted 
Entry  Tue Mar 24 03:05:25 2009, Yoichi, Update, Locking, Locking tonight 
Entry  Tue Mar 24 09:04:02 2009, steve, Update, SUS, 4.8 mag earthquake 
Entry  Tue Mar 24 13:10:07 2009, Alberto, Configuration, PSL, new mirror installed on the AP table 
Entry  Tue Mar 24 13:54:49 2009, Jenne, Update, SUS, Op Levs Centered 
Entry  Tue Mar 24 19:55:24 2009, Jenne, Update, LSC, New PO DC 
    Reply  Tue Mar 24 23:23:05 2009, rana, Update, LSC, New PO DC 
Entry  Wed Mar 25 04:18:28 2009, Yoichi, Update, Locking, Tuesday Locking AO-Loop-p9.png
Entry  Wed Mar 25 09:55:45 2009, steve, Update, IOO, glitching sensors of MC glitchesofMC.jpg
Entry  Wed Mar 25 17:22:58 2009, Yoichi, Update, IOO, MC lock without FSS MC-loop-gain.png
Entry  Wed Mar 25 20:41:43 2009, Jenne, Update, IOO, Mode Cleaner Servo Board Transfer Functions (to be updated) MCwithBoxsmall.JPGMCnoBoxsmall.JPGPomonaBoxforMCsmall.JPG
    Reply  Thu Mar 26 00:45:24 2009, Jenne, Update, IOO, Mode Cleaner Servo Board Transfer Functions (to be updated) MCwithandwithoutfilter25Mar2009.pngPomonaBoxMCfilter25Mar2009.pngMCServoData25Mar2009.tar.gz
Entry  Thu Mar 26 04:01:24 2009, Yoichi, Update, PSL, FSS Open Loop Gain OpenLoopTF.png
Entry  Thu Mar 26 04:09:38 2009, Yoichi, Update, IOO, Single X arm lock spectra with different MC lock schemes XarmSpectra.pdfXarmSpectraZoom.pdf
Entry  Thu Mar 26 04:27:26 2009, Yoichi, Update, Locking, 3.8kHz peak as a function of the arm power CARM-PODC.pdf
Entry  Thu Jan 22 23:36:50 2009, pete, HowTo, oplevs, arm cavity oplev calibration ETMYpitpower.pngETMYpitcal.png
    Reply  Fri Jan 23 12:48:12 2009, Kakeru, Update, oplevs, arm cavity oplev calibration ITMX_pitch.png
       Reply  Thu Jan 29 17:24:41 2009, Kakeru, Update, oplevs, arm cavity oplev calibration 
          Reply  Sat Mar 14 22:53:12 2009, Kakeru, Update, oplevs, arm cavity oplev calibration oplev.pdf
             Reply  Fri Mar 20 15:37:58 2009, Kakeru, Update, oplevs, arm cavity oplev calibration 
                Reply  Thu Mar 26 09:08:18 2009, Kakeru, Update, oplevs, arm cavity oplev calibration 
Entry  Fri Mar 27 02:50:54 2009, Yoichi, Update, Locking, DD demodulation phase suspicious 
Entry  Fri Mar 27 02:40:06 2009, pete, Summary, IOO, MC glitch investigation MC1_Drift.png
    Reply  Fri Mar 27 15:05:42 2009, Yoichi, Update, IOO, MC glitch investigation MC1_Drift.pdfMC2_Drift.pdf
       Reply  Fri Mar 27 17:52:16 2009, Yoichi, Update, IOO, MC glitch investigation 
Entry  Sun Mar 29 13:44:27 2009, steve, Update, SUS, ETMY sus damping restored 
Entry  Mon Mar 30 12:29:17 2009, Yoichi, Configuration, , MC1 glitches not seen during the weekend MC_drift.pdf
Entry  Mon Mar 30 12:46:36 2009, Yoichi, Configuration, IOO, IOO QPDs were missing the beam IOO-QPDs.pdf
Entry  Sun Mar 29 17:54:41 2009, Yoichi, Update, SUS, MC1 drift investigation continued Drift1.pdf
    Reply  Mon Mar 30 09:07:22 2009, rana, Update, SUS, MC1 drift investigation continued 
       Reply  Mon Mar 30 13:29:40 2009, Yoichi, Update, SUS, MC1 drift investigation continued 
Entry  Mon Mar 30 15:51:27 2009, steve, Update, Electronics, HP4291A left the lab to be repaired 
Entry  Mon Mar 30 17:02:46 2009, Yoichi, Configuration, General, AP OSA aligned 
Entry  Tue Mar 31 09:42:32 2009, steve, Update, PEM, ETMY sus damping restored again 
Entry  Wed Apr 1 10:22:13 2009, steve, Update, VAC, RGA logging is working rga-090401.png
Entry  Wed Apr 1 15:47:48 2009, Yoichi, Update, Locking, 3.8kHz peak looks like a real optical response of the interferometer CARM-ETM-EXC.pngAOpath-TFs.png
Entry  Wed Apr 1 16:14:36 2009, Yoichi, Update, Locking, 3.8kHz peak does not change with SRC offset 
Entry  Wed Mar 25 01:37:35 2009, rana, yoichi, Summary, IOO, No Reference Cavity Required 
    Reply  Wed Apr 1 23:18:07 2009, rana, koji, Summary, IOO, No Reference Cavity Required 
Entry  Fri Apr 3 10:01:50 2009, steve, Update, VAC, rgascan with temp plot pd66tempow.jpgrga-090403scan.png
Entry  Fri Apr 3 14:52:38 2009, Jenne, Omnistructure, PEM, Guralp is finally back! 
Entry  Fri Apr 3 17:20:05 2009, Yoichi, Update, Locking, The 3.8kHz peak seems like the DARM RSE (not 100% sure though) AO-TF-DARM-OFFSET.pngAO-TF-DARM-DEMOD-PHASE.pngAO-TF-MICH-OFFSET.pngPOX_1I.pngDARM-Loop.pdf
Entry  Mon Apr 6 19:09:15 2009, Jenne, Update, PEM, Old Guralp is hooked back up to the ADC 
Entry  Mon Apr 6 21:50:43 2009, rana, Update, LSC, Arm Locking via pushing MC2 mc2-xarm.pdfUntitled.pngnohands.pdf
Entry  Wed Apr 8 02:47:42 2009, Yoichi, Update, Locking, Locking status CARM_TFs.pdfDARM_TFs.pdfDARM-CARM-Coupling.pdf
Entry  Tue Apr 7 21:39:57 2009, Yoichi, Configuration, Computers, LSC code recompiled with a fix for denormalization problem 
    Reply  Wed Apr 8 18:18:33 2009, rana, Configuration, Computers, LSC code recompiled with a fix for denormalization problem 
Entry  Wed Apr 8 18:46:50 2009, rana, Configuration, General, DMF, SVN, x2mc, and matlab 
Entry  Thu Apr 9 11:27:19 2009, steve, Update, VAC, vac gauge reading problem vacgflsec.jpgvacgflmin.jpg
Entry  Thu Apr 9 12:23:49 2009, pete, Update, Locking, tuning ETM common mode FPMI-DARM-CARM-ETM-fineScan.pdf
Entry  Thu Apr 9 20:56:12 2009, Yoichi, HowTo, General, Restore the alignment. Write elog entries. 
Entry  Fri Apr 10 01:24:08 2009, rana, Update, Computers, allegra update (sort of) 
Entry  Thu Apr 9 23:11:27 2009, rob, Summary, Locking, Laser PM to PO-DC transfer functions at multiple CARM offsets CARMoffs1.pngCARMoffs2.pngCARMcarpet.png
    Reply  Thu Apr 9 23:20:35 2009, rob, Summary, Locking, Laser PM to REFL-DC transfer functions at multiple CARM offsets CARMoffs1_r.pngCARMoffs2_r.pngCARMcarpet_r.png
       Reply  Fri Apr 10 03:10:08 2009, rana, Summary, Locking, Laser PM to REFL-DC transfer functions at multiple CARM offsets 
Entry  Fri Apr 10 04:54:24 2009, Yoichi, Update, Locking, REFL_DC for CARM AO-loop-gain-CARM-REFL_DC.png
Entry  Fri Apr 10 18:11:18 2009, Jenne, Update, PSL, ISS has a bad cable? 
ELOG V3.1.3-