40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 248 of 344  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  12437   Wed Aug 24 14:44:33 2016 PrafulUpdateElectronicsDecoupling capacitor 101Do these look good for the ceramic capacitors?
We're running low.

http://www.mouser.com/ProductDetail/Vishay-BC-Components/K104K15X7RF53L2/?qs=sGAEpiMZZMuMW9TJLBQkXmrXPxxCV7CRo6C15yUYAos%3d
  
  12438   Wed Aug 24 19:37:55 2016 KojiUpdateElectronicsDecoupling capacitor 101Yes

Interesting articles how they should
only be used for power decoupling and not
  
  12439   Wed Aug 24 23:47:30 2016 PrafulUpdateElectronicsFinished Prototype BoxGautam helped me drill holes in a metal
box and I set up my circuit inside. Everything
seems to be working so far. Tomorrow I'll
 out1.pdfout2.pdfout3.pdfin1.pdfin2.pdf 
  12440   Thu Aug 25 08:19:25 2016 Max IsiUpdateGeneralSummary pages down due to cluster maintenance The system is back from maintenance and
the pages for last couple of days will be
filled retroactively by the end of the week.
  
  12441   Thu Aug 25 15:43:29 2016 ericqUpdateSUSOSEM issuesWe've seen for some time now that one
of the PRM OSEM signals has been gone, and
all of the SRM signals seem dark. We had
 SRM_OSEMS.pngPRM_LR.png 
  12442   Thu Aug 25 19:03:56 2016 PrafulUpdateElectronicsAcoustic Tab and Amp SuspensionMy box has been suspended in the PSL using
surgical tubing, and it has been connected
to C1:PEM-MIC_1 (C17) with a BNC. I made
  
  12443   Thu Aug 25 20:07:35 2016 gautamUpdateSUSOSEM issues - maybe resolved?[lydia, johannes,
gautam]

While
  
  12444   Thu Aug 25 21:11:43 2016 gautamUpdateSUSETMY back in IFOThere was
some confusion as to the order in which we
should go about trying to recover the Y arm.
 ETMY_BounceSpectra_25Aug2016.pdf 
  12445   Fri Aug 26 11:35:44 2016 gautamUpdateSUSETMY UL sensor problematic I've been noticing that the ETMY UL
sensor output has been erratic  over
the last few days. It seems to be jumping
 ETMY_BounceSpectra_26Aug2016.pdf41.png19.png 
  12446   Fri Aug 26 14:05:38 2016 SteveUpdateSUSETMY UL sensor problematic This problem has existed well before the
vent

 
 ETMY-ULhistory.png 
  12447   Fri Aug 26 14:09:46 2016 ericqUpdateSUSETMY UL sensor problematic We do indeed have a box of clean spare
OSEMs, it should be out with all of the other
boxes of clean stuff we had for the suspension
  
  12448   Fri Aug 26 17:48:14 2016 gautamUpdateSUSbounce mode coupling reductionWe worked on reducing the bounce mode coupling
into the sensor signals today. After some
trial and error, essentially following the
 ETMY_BounceSpectra_26Aug2016_1.pdf 
  12449   Sun Aug 28 21:40:11 2016 gautamUpdateSUSETMY UL sensor problematic I wanted to observe the UL coil for any
excursions over the weekend. Looking at the
2 day trend, something is definitely wrong.
 ETMY_UL_problematic.png 
  12450   Mon Aug 29 09:37:05 2016 gautamUpdateSUSETMY UL sensor problematic It looks like the problem is indeed in
the Satellite box. Attachment #1 shows the
second trend for the last 12 hours (~930pm
 satelliteBox.png 
  12451   Mon Aug 29 14:42:06 2016 gautamUpdateSUSETMY Satellite box diagnosticsI opened up the ETMY satellite box to investigate
the glitches seen in the UL sensor output. 

Attachments #1 & 2: The
 IMG_6840.JPGIMG_6841.JPG 
  12452   Mon Aug 29 21:53:14 2016 LydiaUpdateSUSETMY bounce mode coupling[gautam, johannes, lydia]

We decided to try some different
approaches on minimizing the ETMY bounce
 IMG_3051.JPG42.png 
  12453   Tue Aug 30 09:51:37 2016 SteveUpdateSUSthe chamber HEPA tents are backHow to minimize particles entering the
vacuum envelope.

 
 ETMYtentHEPA.jpgvented_for_60_days.png 
  12454   Tue Aug 30 15:44:28 2016 SteveUpdateSUS wire standoffs update100
Sapphire prisms ordered. Delivery date
9-30-2016
  
  12455   Tue Aug 30 20:26:36 2016 gautamUpdateSUSITMY installed[gautam,
johannes, lydia]
 IMG_3052.JPGSRM_sensor_level_comp.pngETMY_BounceSpectra_30Aug2016.pdf 
  12456   Wed Aug 31 18:07:43 2016 JohannesUpdateSUSITMY free swinging[Lydia, Gautam, Koji, Johannes]

Summary of things done today:
  
  12457   Wed Aug 31 22:09:18 2016 gautamUpdateSUSY arm locked to Green Koji tweaked the alignment sliders till
we were able to get the Y arm locked to green
in a 00 mode, GTRY ~ 0.5 which is the prevent
  
  12458   Wed Aug 31 23:01:02 2016 gautamUpdateSUSthe chamber HEPA tents are backSome more numbers we found while working
in/around the chamber today:

  
  12459   Thu Sep 1 08:30:24 2016 SteveUpdateSUSITMY_UL is sickSo if the SRM satellite box is good, than
the ITMY sensor UL or vacuum cabeling from
sersor to sat amp is bad.
 ITMY_SENSOR_UL.pngspareSatAmp.jpg 
  12460   Thu Sep 1 15:28:01 2016 ranaUpdateElectronicsAcoustic Tab and Amp Suspension
add photo of installation
no
more secret personal pages! put channels
into the actual pages that we look at
make
  
  12461   Thu Sep 1 15:40:52 2016 SteveUpdateSUSHEPAs on each chamber doorThis is an option to isolate the vacuum
chamber from the dusty 40m lab: 4x8 HEPA
unit or
 chamberDoorHepaEA.pdf 
  12462   Thu Sep 1 15:43:16 2016 ranaUpdateSUSOSEM adjustmentsOn the bounce roll balancing:

Recall that back in 2006, the main
issue was not with the bounce mode coupling
  
  12463   Thu Sep 1 17:25:02 2016 PrafulUpdateElectronicsAcoustic Tab and Amp SuspensionI'll add a picture of the installation
when I get back to campus and finish hooking
up the power cable. I haven't added this
  
  12464   Thu Sep 1 19:18:14 2016 JohannesUpdateSUSITMX and ETMX preemptive table levelingI balanced the ITMX and ETMX tables into
level position today, for which I had to
move quite a few of the on-table weights.
 8x 
  12465   Thu Sep 1 19:59:22 2016 JohannesUpdateSUSIR mode flashes in Y arm[Gautam, Lydia, Johannes]


After placing the irises
on the ETMY and ITMY cages we found that
  
  12466   Fri Sep 2 21:09:08 2016 gautamUpdateSUSY arm locked in air[johannes, lydia, gautam]


The Y arm has been locked
to IR in air using POY11 as an error signal 
 03.png56.png 
  12467   Fri Sep 2 21:15:53 2016 gautamUpdateSUSITMX and ETMX preemptive table levelingThe ITMX table had relaxed overnight into
a slightly misaligned state overnight - since
the ITMX table holds PR2 and hence can affect
  
  12468   Fri Sep 2 21:16:45 2016 ranaUpdateElectronicsSatellite AmplifierIn November of 2010, Valera Frolov (LLO),
investigated
our satellite amplifiers and made some recommendations
  
  12469   Mon Sep 5 19:57:24 2016 OsamuUpdateSUSOSEM adjustmentsHi 40m people,

As Rana is saying, the bounce mode
does not matter, or we cannot do anything. Generally
  
  12470   Mon Sep 5 21:05:06 2016 ranaUpdateElectronicsSatellite AmplifierThe attached PDF shows the output noise
of the satellite amp. This was calculated
using 'osempd.fil' in the 40m/LISO
 osempd.pdf 
  12471   Tue Sep 6 00:14:14 2016 gautamUpdateElectronicsSatellite Amplifier 




 osempdComparison.pdf 
  12472   Tue Sep 6 18:21:13 2016 ranaUpdateSUSOSEM issuesI looked at the PRM free swing spectra.
The modes look like they're at the right
frequencies, so pointing more and more towards
 PRMswing.png 
  12473   Tue Sep 6 20:30:56 2016 ranaUpdateSUSITMY_UL is sickIn the morning, Steve will start opening
the north BS door so that we can enter to
inspect the PRM LR OSEM.
  
  12474   Tue Sep 6 20:45:14 2016 gautamUpdateSUSX arm test masses back in chamber[Teng, Johannes,
Lydia, gautam]


The
 IMG_3137.JPGIMG_3143.JPGIMG_3142.JPGIMG_3148.JPG 
  12475   Tue Sep 6 20:52:42 2016 gautamUpdateSUSOSEM issues



The
 P9060254.JPG 
  12476   Wed Sep 7 17:23:26 2016 gautamUpdateSUSPRM LR fixed for now[johannes, gautam]


We took the heavy door
off in the morning with Steve's help
The
 IMG_3208.JPGIMG_3211.JPG 
  12477   Wed Sep 7 18:00:47 2016 LydiaUpdateGeneralAcromag Progress[Teng, Lydia]

We
would like to establish a system for setting
  
  12478   Thu Sep 8 22:12:36 2016 gautamUpdateSUSX arm in place, locked to green, IR flashes visibleDetailed elog to follow but summary of
todays activities:


ITMX and ETMX are back
  
  12479   Fri Sep 9 11:24:15 2016 SteveUpdatesafetysafety trainingVisiting
graduate student Teng Zhang from Glasglow
  
  12480   Fri Sep 9 17:50:02 2016 gautamUpdateSUSHeavy doors on BS-PRM, ETMY chambers[steve, teng, johannes, lydia, gautam]


we set about doing some
final checks on the Y arm while Johannes
  
  12481   Sat Sep 10 14:26:01 2016 ranaUpdateGeneralPRM SRM alignmentFor the PRM, I aligned it until the arm
flashes were maximized and the REFL camera
showed a centered spot with dips happening
 Osamu.JPG 
  12482   Mon Sep 12 17:15:22 2016 JohannesUpdateGeneralPRM SRM alignment[Gautam, Steve, Johannes]

We put on the remaining heavy doors
on the chambers (ITMY, ITMX,ETMX, in this
 IMG_3273.JPGIMG_3275.JPG 
  12483   Mon Sep 12 17:54:24 2016 SteveUpdateVACpumpdown 79 We are pumping down. The annuloses
are below 10 mTorr

The vacuum gauges are not communicating
  
  12484   Mon Sep 12 20:15:22 2016 LydiaUpdateSUSDiagonalization in air[Lydia, Teng]

We ran the scripts to diagonalize
the damping matrices using the free swinging
 ITMY_fit.jpgBS_diag.jpg 
  12485   Mon Sep 12 20:19:25 2016 LydiaUpdateGeneralMC REFL beam splitter not replacedThe
beam splitter that directs light into the
MC REFL photodiode has not been replaced;
  
  12486   Tue Sep 13 11:00:59 2016 LydiaUpdateSUSETMY UL glitch returned 




  
ELOG V3.1.3-