  12181   Wed Jun 15 09:52:02 2016 jamieUpdateCDSVery encouraging results from overnight split daqd testVery encouraging   
  12182   Wed Jun 15 10:19:10 2016 SteveConfigurationCDSGPS antennas... debuggingVisual
inspection of rooftop GPS antennae:
 6x 
  12183   Wed Jun 15 11:21:51 2016 jamieUpdateCDSstill work to do to transition to new configuration/codeJust to be clear, there's still quite
a bit of work to fully transition the 40m
to this new system/configuration.  Once
  
  12185   Wed Jun 15 22:12:55 2016 varunUpdateCDSDAFI update: stereo outputI wish to have stereo audio output for
the DAF module. Hence, there needs to be
a second output from the DAF. I added this
 IMG_20160615_145535907.jpgIMG_20160615_145413005_HDR.jpgIMG_20160616_101229499.jpgIMG_20160616_101157096.jpg 
  12186   Thu Jun 16 08:52:14 2016 SteveUpdateGeneralilluminators turned offPSL, BS, ITMY and ETMX the illuminators
were left on over night.
  
  12187   Thu Jun 16 11:10:17 2016 SteveUpdateSUSspare ETMX optics preparation to be hanged



D
Location
 SOSsus_Page_1.pngSOSsus_Page_2.pngETMXspareTowerFace.jpgETMXspareTowerBack.jpgmagnets-dumbbells.jpg 
  12188   Thu Jun 16 11:25:00 2016 JohannesUpdateLSCY-Arm round-trip loss measurement with ALSUsing the ALS green beat and armlength
feedback I mapped an IR resonance of the
Y-Arm by stepping through a ramp of offset
 T_vs_steps.pdff_vs_steps.pdf 
  12189   Thu Jun 16 12:06:59 2016 ericqUpdateLSCRF Amp installed at POY11 RF outputI have installed a ZFL-500LN on the RF
output of POY11. This should reduce the effect
of the CM board voltage offsets by increasing
 IMG_3426.jpg 
  12190   Thu Jun 16 15:57:46 2016 gautamUpdateCOCContrast as a function of RoC of ETMXSummary

In a previous elog, I demonstrated
that the RoC mismatch between ETMX and
 contrastDefect.pdffinesseCode.zip 
  12191   Thu Jun 16 16:11:11 2016 jamieUpdateCDSupgrade aborted for nowAfter poking at the new configuration more,
it also started to show instability. 
I couldn't figure out how to make test
  
  12192   Thu Jun 16 18:08:57 2016 JohannesUpdatePSLBefore the AOM installationThere was only one razor blade beam dump
labeled for atmospheric use left, but that's
all we need. Steve is working on restocking.
 IMG_20160615_154556392e.jpg 
  12193   Thu Jun 16 18:42:12 2016 ranaUpdateCOCContrast as a function of RoC of ETMXThat sounds weird. If the ETMY RoC   
  12194   Thu Jun 16 23:02:57 2016 gautamUpdateCOCContrast as a function of RoC of ETMX


 contrastDefect.pdf 
  12195   Fri Jun 17 15:22:31 2016 gautamUpdateVACN2 supply line restored after retiling


 c0vac_06172016.png 
  12196   Fri Jun 17 22:36:11 2016 JohannesUpdatePSLAOM installationSubham and I have placed the AOM back into
the setup right in front of the PMC.

Steps undertaken:
 aom_new_mount.jpgaom_beam_split.jpgaom_dump_IR.jpg 
  12197   Mon Jun 20 01:38:04 2016 ranaUpdateCOCContrast as a function of RoC of ETMXSo, it seems that changing the ETMX for
one of the spares will change the contrast
defect from ~0.1% to 0.9%. True? Seems like
  
  12198   Mon Jun 20 08:26:56 2016 SteveUpdatePSLAOM picturesGood job Johannes and Subham.

 
 AOMinplace.jpginplaceAOM.jpgAOMin.png 
  12199   Mon Jun 20 09:36:10 2016 SteveUpdateSUS EQ 3.1 m Big Bear Lake, CANo suspention lost damping.

 
 eq3.1BigBearLakeCA.png 
  12200   Mon Jun 20 11:11:20 2016 SteveConfigurationCDSGPS receiver not resetting properlyI called https://www.endruntechnologies.com/pdf/USM3014-0000-000.pdf 
and they said it's very likely just needs
a software update. They will email Jamie
  
  12201   Mon Jun 20 11:19:41 2016 jamieConfigurationCDSGPS receiver not resetting properly


  
  12202   Mon Jun 20 14:03:04 2016 jamieConfigurationCDSEndRun GPS receiver upgraded, fixedI
just upgraded the EndRun Technologies Tempus
LX GPS receiver timing unit, and it seems
 GPSreceiverWorking.jpg 
  12203   Mon Jun 20 16:33:09 2016 VarunUpdateElectronicsAnti-Aliasing Filter circuit schematicSummary: The aim is to
design an analog anti-aliasing (AA) filter
placed before the ADC, whose function is
 8x 
  12204   Mon Jun 20 18:07:15 2016 gautamUpdateCOCContrast as a function of RoC of ETMX


 contrastDefectComparison.pdf 
  12205   Tue Jun 21 04:01:09 2016 ericqUpdateLSCY arm @ 30kHz UGF w/POY, AOWith the newly amplified POY signal, locking
the mode cleaner to the Y arm at ~30kHz bandwidth
was quite straightforward. The offset jumps
 inloop_outloop.pdfxarm.pdfyolg.png 
  12207   Tue Jun 21 11:26:42 2016 varunFrogsCDSmedm command not working"medm: command not
found" error when run through
  
  12208   Tue Jun 21 11:49:29 2016 ericqFrogsCDSmedm command not workingThe workstations' .bashrc
is a symbolic link to /users/controls/.bashrc

In it, someone commented out the
  
  12209   Tue Jun 21 14:12:10 2016 SteveUpdatePEM vacuum envelope wipedI wiped down the cranes with wet towel
and Mario our janitor did the chamber tops
with the tubes.
 60dPEM.png 
  12210   Wed Jun 22 08:40:42 2016 ranaUpdateLSCY arm @ 30kHz UGF w/POY, AOBelow 100 Hz, I suppose this means that
the X arm is now limited by the quadrature
sum of the X and Y arm seismic noise.
  
  12211   Wed Jun 22 10:15:45 2016 varunUpdateCDSDAFI update: stereo outputI have updated the DAFI with the following
changes:

1) Separated both the channels
 C1DAF_OVERVIEW.pngDAF_link_from_LSC.png 
  12212   Wed Jun 22 14:03:42 2016 VarunUpdateElectronicsAnti-Aliasing Filter circuit schematicI found an anti-aliasing circuit on the
40m wiki. It consists of A differential LPF
made using THS4131 low noise differential
 io.pdfAA.JPGratios_v2.pdf 
  12213   Thu Jun 23 17:24:32 2016 ericqUpdateGeneralTweaksI spent some time this afternoon reviving
some of my CESAR/ESCOBAR shenanigans on the
Y arm. I found it neccesary to adjust a few
  
  12214   Sun Jun 26 15:27:28 2016 ranaFrogsIOOPMC /MC lopcedFound PMC unlocked for many hours so I
relocked it. IMC relocked by itself, but
the input switch seems to be flickering to
  
  12215   Mon Jun 27 15:12:09 2016 varunUpdateCDSDAFI update: stereo outputUsing an RC to BNC connector from the inner
drawer, I have added a second output cable
going from the output Fibox in the control
 IMG_20160627_151753247.jpg 
  12216   Mon Jun 27 15:26:03 2016 SteveOmnistructureALARMfire alarm testThe fire alarm came on around 15:05 
for about 2-3 minutes. We all  left
the lab and counted heads.  I called
 fireAlarmTest.png 
  12217   Mon Jun 27 15:47:17 2016 SteveUpdateGeneralQPR clean room glovesI got some
QPR Nitrile gloves. They are LIGO approved.White
nitrile gloves are naturally anti-static-
  
  12218   Tue Jun 28 09:14:27 2016 SteveUpdateSUS ETMX optics preparation to be rehangedGiven the effect on the contrast defect,
the consensus at the meeting Wednesday 6-22 
was that we should continue to use the existing
 nylonFCss.jpg 
  12219   Tue Jun 28 16:06:09 2016 gautamUpdateCOCRC folding mirrors - further checksHaving investigated the mode-overlap as
a function of RoC of the PRC and SRC folding
mirrors, I've now been looking into possible
 C1_HOMcurves_Y.pdfC1_HOMcurves_DR.pdf 
  12220   Tue Jun 28 16:09:41 2016 PrafulUpdateGeneral40m Summary PagesSet up gwsumm on optimus and generated
summary pages from both L1 and C1 data. Still
a few manual steps need to be taken during
  
  12221   Tue Jun 28 16:10:49 2016 PrafulUpdateGeneralBluebird MicrophonesFound 1 out of 2 bluebird microphones in
the 40m.
  
  12222   Tue Jun 28 17:11:27 2016 PrafulUpdateGeneralEM172 MicrophonesFound 60 EM172 microphones. Previous elog
with details: 7777.
  
  12223   Tue Jun 28 20:43:23 2016 KojiSummaryCOCFirst Contact cleaning practiceMade a dry run of the in-situ cleaning
for a 3inch optic.

Attachment 1: The Al dummy mass
 7x 
  12224   Tue Jun 28 22:54:43 2016 AakashUpdateGeneralSeismometer Enclosure Development | SURF 2016The existing enclosure for seismometer
at LIGO 40m lab is a cylindrical stainless
steel can placed upside down over the seismometer.
 plot1.pngplot2_corrected.png 
  12225   Wed Jun 29 00:09:36 2016 AakashUpdateGeneralThings from past | SURF 2016I have taken out the heaters and temperature
sensors from the enclosure which was made
by Megan last summer. Soon I will test and
  
  12226   Wed Jun 29 08:20:04 2016 SteveUpdateSUS First Contact shelf life
We'll follow LIGO policy:
Our
policy is to use first contact within 1 year
of purchase for use in the interferometers.
  
  12227   Wed Jun 29 14:32:22 2016 SteveUpdateSUS how to remove epoxy from optics 

Hi Steve -
  
  12228   Wed Jun 29 15:34:00 2016 SteveUpdatesafetySURF 2016 safetyPraful Vasiceddy received 40m specific
basic safety training.

  
  12229   Wed Jun 29 16:02:29 2016 SteveUpdateSUS ETMX beam baffleIn the attached photo from 2012, one can
see the installed black glass baffle. According
to the drawings (LIGO-DNNNXXX) this one has
 IMG_1608.JPG 
  12230   Wed Jun 29 16:05:47 2016 ericqUpdateSUSETMX suspension readinessI've gone through the SOS suspension
document (E970037)
and some old elogs to get an idea of all
  
  12231   Thu Jun 30 10:03:16 2016 SteveUpdateSUS how to remove epoxy from opticsProposed Acetone soak dish for SOS epoxy
softening.

It has good acces through 5"
 SOSsoakDish.jpgSOSsoakDish_tv.jpg 
  12232   Thu Jun 30 14:31:02 2016 ChemistryUpdateSUSNO   mad-scientist.jpg 