40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 242 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  15607   Fri Oct 2 10:29:49 2020 gautamUpdateOptical LeversETMY, BS and ITMX HeNes degradingAttachment
#1 shows that the
 OLsum.png 
  15717   Wed Dec 9 11:54:11 2020 gautamUpdateOptical LeversITMX HeNe replacedThe ITMX Oplev (installed in March 2019)
was near end of life judging by the SUM channel
(see 
 OLtrend_old_ndscope.pngITMX_OL_P.pdfITMX_OL_Y.pdf 
  15749   Wed Jan 6 16:18:38 2021 gautamUpdateOptical LeversBS Oplev glitchyAs part of the hunt why the X
arm IR transmission RIN is anomalously high,
I noticed that the BS Oplev Servo periodically
 missingData.pngOLRIN.pdfBS_OL_P.pdfBS_OL_suppression.pdf 
  16231   Wed Jun 30 15:31:35 2021 AnchalSummaryOptical LeversCentered optical levers on ITMY, BS, PRM and ETMYWhen both arms were locked, we found that
ITMY optical lever was very off-center. This
seems to have happened after the c1susaux
  
  16236   Thu Jul 1 16:55:21 2021 AnchalSummaryOptical LeversFixed Centeringoptical levers PRMThis was a mistake. When arms are locked,
PRM is misaligned by setting -800 offset
in PIT dof of PRM. The oplev is set to function
  
  16266   Thu Jul 29 14:51:39 2021 PacoUpdateOptical LeversRecenter OpLevs[yehonathan, anchal, paco]

Yesterday around 9:30 pm, we centered
the BS, ITMY, ETMY, ITMX and ETMX oplevs
  
  16268   Tue Aug 3 20:20:08 2021 AnchalUpdateOptical LeversRecentered ETMX, ITMX and ETMY oplevs at good stateLate elog. Original time 08/02/2021 21:00.

I locked both arms and ran ASS
to reach to optimum alignment. ETMY PIT >
  
  16407   Fri Oct 15 16:46:27 2021 AnchalSummaryOptical LeversVent PrepI centered all the optical levers on ITMX,
ITMY, ETMX, ETMY, and BS to a position where
the single arm lock on both were best aligned.
 Screen_Shot_2021-10-15_at_4.34.45_PM.pngScreen_Shot_2021-10-15_at_4.45.31_PM.pngScreen_Shot_2021-10-15_at_4.34.45_PM.pngScreen_Shot_2021-10-15_at_4.34.45_PM.png 
  16751   Fri Apr 1 14:26:50 2022 TegaUpdateOptical LeversSimplified sketch on MC tableHere is an early sketch
of the MC table. 

 
 MC_Table.drawio.pdf 
  16752   Fri Apr 1 17:02:02 2022 KojiUpdateOptical LeversSimplified sketch on MC tableWe are supposed to have BS Oplev Beams.
We don't like the shallow angle reflections
(i.e. AOI>45deg).
  
  16753   Fri Apr 1 22:22:29 2022 KojiUpdateOptical LeversSimplified sketch on MC tablePossibility to swap BS and ITMX
tables:
BS table, which Tega said MC table,
  
  16755   Mon Apr 4 15:49:06 2022 TegaUpdateOptical LeversSimplified sketch on BS tableI have updated the BS table using feedback
from Koji and Paco and the attached
pdf document is the latest iteration.
 BS_Table.drawio.pdf 
  8018   Wed Feb 6 20:19:52 2013 ManasaUpdateOpticsG&H and LaserOptik mirrors[Koji, Manasa]
We measured the wedge angle of the
G&H and LaserOptik mirrors at the OMC
  
  8023   Thu Feb 7 14:10:25 2013 ManasaUpdateOpticsLaserOptik - AR Reflectivity - Bad dataReflectivity of AR surface of LaserOptik
(SN6)
 
 SN6_R.pngSN6_R.png 
  8045   Fri Feb 8 21:14:52 2013 ManasaUpdateOpticsG&H - AR Reflectivity  Hours of struggle and still no
data 
 pr2.png27_1044419003.bmp 
  8046   Fri Feb 8 22:49:31 2013 KojiUpdateOpticsG&H - AR Reflectivity How about to measure the AR reflectivity
at larger (but small) angles the extrapolate
the function to smaller angle, 
  
  8047   Fri Feb 8 23:04:40 2013 ManasaUpdateOpticsG&H - AR Reflectivity

    

       
            
  
  8051   Sat Feb 9 19:34:34 2013 ranaUpdateOpticsG&H - AR Reflectivity  
 Use the trick I suggested:
Focus the beam so that the beam size
  
  8060   Mon Feb 11 17:54:02 2013 KojiSummaryOpticsCurvature radii of the G&H/LaserOptik mirrorsI, by chance, found  that my windows
partition has Vision32 installed.
So I run my usual curvature characterization
 TT_Mirrors_RoC.pdf 
  8063   Mon Feb 11 19:55:47 2013 ManasaUpdateOpticsG&H - AR Reflectivity  
I adjusted the focal length of the
focusing lens and reduced the beam size enough
  
  8069   Tue Feb 12 18:28:46 2013 JamieSummaryOpticsCurvature radii of the G&H/LaserOptik mirrors

    

       
            
  
  8075   Wed Feb 13 09:28:56 2013 SteveUpdateOpticsG&H - HR plots 
 Gooch & Housego optics
order specification from 03-13-2010
  
  8316   Wed Mar 20 14:44:47 2013 JamieUpdateOpticsupdated calculations of PRC/SRC g-factors and ARM mode matchingBelow are new alamode calculations of the
PRC and SRC g-factors and arm mode matchings. 
These include fixes to the ABCD matrices
  
  8339   Mon Mar 25 16:51:59 2013 JenneUpdateOpticsupdated calculations of PRC/SRC g-factors and ARM mode matchingI think we like the idea of flipping SR2
better than SR3 for the same ghost beam reasons
as PR2 is better than PR3.  There isn't
  
  8352   Tue Mar 26 11:33:55 2013 JamieUpdateOpticsHOWTO calculate effective RoC of flipped TTIn case anyone is curious how I got the
numbers for the effective radius of curvature
of the flipped TT mirrors, I include the
 mirror.mtransmission.mTTflipped.mM2Reff.m 
  13450   Wed Nov 22 17:52:25 2017 gautamUpdateOptimal ControlVisualizing cost functionsI've attempted to visualize the various
components of the cost function in the way
I've defined it for the current iteration
 globalCosts.pdf 
  13497   Tue Jan 2 16:37:26 2018 gautamUpdateOptimal ControlOplev loop tuningI've made various changes to the optimal
loop design approach, but am still not having
much success. A summary of changes made:
 loopOpt_180102_1706.pdfglobalCosts.pdf 
  13498   Wed Jan 3 12:33:16 2018 ranaUpdateOptimal ControlOplev loop tuningWhen putting code into git.ligo.org, one
way to have automated testing is to use the
Gitlab CI. This is an automated 'checker',
  
  13500   Wed Jan 3 16:25:32 2018 awadeUpdateOptimal ControlOplev loop tuningAnother cool feature
is client side pre-commit hooks. 
  
  13520   Tue Jan 9 21:57:29 2018 gautamUpdateOptimal ControlOplev loop tuningAfter some more tweaking, I feel like I
may be getting closer to a cost-function
definition that works.
 loopOpt_180108_2232.pdf 
  17192   Sat Oct 15 17:22:56 2022 ChrisUpdateOptimal ControlIMC alignment controller testing[Anchal, Radhika, Jamie, Chris]

We conducted a test of three alternative
controllers for the IMC pitch DOFs on Friday.
 180.png066.png202.png 
  17198   Tue Oct 18 20:43:38 2022 AnchalUpdateOptimal ControlIMC open loop noise monitorWFS loops were running for past 2 hours
when I made the overall gain slider zero
at:
  
  17199   Wed Oct 19 09:48:49 2022 AnchalUpdateOptimal ControlIMC open loop noise monitorTurning WFS loops back on at:

PDT: 2022-10-19 09:48:16.956979
PDT
  
  17314   Sun Nov 27 15:30:22 2022 ChrisUpdateOptimal ControlIMC alignment controller testingFive more mode cleaner alignment controllers
were tested this morning (remotely). These
were designed to run in tandem with the standard
  
  17   Fri Oct 26 09:10:17 2007 steveRoutinePEMPEM &PSL trendThe fires are out, lab particle counts are
up.
Psl HEPAs are at 100% and mobel HEPAs are
 counts&psl.jpg5dcounts.jpg 
  83   Thu Nov 8 11:40:21 2007 steveUpdatePEMparticle counts are upI turned up the psl HEPA filter to 100%
This 4 days plot shows why
 pslhepaon.jpg 
  114   Mon Nov 19 14:19:25 2007 steveOmnistructurePEMjackhammerThe construction personal successfully jackhemmered
a fence around the "Drever's parking slot"
There is no parking space available close
 jackhammer.jpgjackhammer2.jpg 
  151   Fri Nov 30 20:17:26 2007 AndreyConfigurationPEMAccelerometers and alum.plates for themAll 6 accelerometers which were located near
the ITMX are turned off and disconnected
from the power cords.
 Scheme_Aluminum_Piece-inches.pdf 
  152   Fri Nov 30 21:27:24 2007 ranaDAQPEMweather / stacis / c1pem1I was trying to add some Seis BLRMS channels
to the c1pem1 processor so that we could
have DMT trends.
  
  161   Mon Dec 3 19:44:58 2007 Accelerometers on new mountsConfigurationPEMAndrey
I (Andrey) continued today working with new
accelerometer mounting. (see entry #151 about
 DSC_0194.JPGDSC_0195.JPGDSC_0196.JPG 
  172   Wed Dec 5 23:19:03 2007 AndreyConfigurationPEMAccelerometers are turned on
All accelerometers have been turned on, as
Alan asked during Wednesday meeting.
 7x 
  189   Wed Dec 12 22:24:48 2007 tobinFrogsPEMweather stationI poked at the weather station briefly this
evening.
  
  200   Wed Dec 19 11:31:01 2007 steveOmnistructurePEMaircond filter maintenanceJeff is working on all air condiontion units
of the 40m lab
This we do every six months.
 acfilters6m.jpg 
  204   Wed Dec 19 20:28:27 2007 AndreyDAQPEMNames for all 6 accelerometers have been changed
I eventually [COLOR=red]changed the names
for all 6 accelerometers[/COLOR] (see my
  
  255   Wed Jan 23 11:41:06 2008 steveUpdatePEMsulfur smell in 40mLed - acid car batteries were overcharged
in the machine shop next door
and sulfuric acid smell is coming over to
  
  258   Thu Jan 24 11:52:56 2008 steveUpdatePEMthe mud is cleaned up & MOPA shutter is openedSafety glasses are required again!

I have just opened the mopa shutter.
  
  264   Fri Jan 25 09:22:21 2008 steveUpdatePEMburned toast award goes toDYM for  collaborating with the enemy. 

In order to minimize the number of ants visiting
  
  283   Mon Jan 28 19:35:55 2008 ranaSummaryPEMAccelerometer and Seismometer Coherences[FONT=Arial][COLOR=purple]The attached PDF
shows that there is some strange behavior
at low frequencies.[/COLOR][/FONT]
 Acc.pdf 
  295   Sun Feb 3 05:02:41 2008 ranaUpdatePEMSeism 4 day   Screenshot.png 
  298   Tue Feb 5 17:39:05 2008 jweinerConfigurationPEMPEM-AS_MIC taken down from AS table, will put in PSL enclosure soonI took down the microphone that Andrey hung
above the AS table his first week in lab.
I want to hang the microphone above the PMC
  
ELOG V3.1.3-