40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 241 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  13087   Thu Jun 29 10:04:18 2017 jigyasaUpdateComputer Scripts / ProgramsMC2 Pitch-Yaw offsetThe script is being executed again, now.




  
  13089   Fri Jun 30 11:08:26 2017 jigyasaUpdateCamerasGigE camera at ETMX
With Steve's help in
 PicturesETMX.pdfdirtyETMXwindow.jpg 
  13091   Fri Jun 30 15:25:19 2017 jigyasaUpdateCamerasGigE camera at ETMXAll thanks to Steve, we cleaned the view
port on the ETMX on which the camera is installed,
and with a little fine tuning of the focus
 Image__2017-06-30__15-10-05.pdf14ms.pdf 
  13092   Fri Jun 30 16:03:54 2017 jigyasaUpdateCamerasGigE camera at ETMX 




 14msexposure.png 
  13098   Thu Jul 6 11:58:28 2017 jigyasaUpdateCamerasHDR images of ETMXI captured a few images of the beam spot
on ETMX at 5ms, 10ms, 14ms, 50ms, 100ms,
500ms, 1000ms exposure and ran them through
 ETMXHDRcolormap.pngETMXHDRimage.png 
  13105   Mon Jul 10 17:13:21 2017 jigyasaUpdateComputer Scripts / ProgramsCapture image without pylon GUIOver the day, I have been working on a
C++ program to interface with Pylon to capture
images and reduce dependence on the Pylon
  
  13118   Sat Jul 15 01:28:53 2017 jigyasaUpdateCamerasBRDF CalibrationsThis evening,
Gautam helped me with setting up the apparatus
for calibrating the GigE for BRDF measurements.
  
  13121   Sun Jul 16 11:58:36 2017 jigyasaUpdateCamerasBRDF Calibrations 

From
what I understood froom my reading, [Large-angle
  
  13122   Sun Jul 16 12:09:47 2017 jigyasaUpdateCamerasBRDF CalibrationsWith this idea in mind, we can now actually
take images of the illuminated paper at
different scattering angles, assume BRDF
  
  4394   Thu Mar 10 01:28:47 2011 joe, jamie, rana, chrisSummaryCDSSimSuspension !Today was a banner day for  40mETMY.pngdvsim.pngredpill_bluepill.jpg 
  2624   Mon Feb 22 11:38:05 2010 joe, jenne and steveConfigurationVACvacuum is back to normalMorning condition: vacuum rack power is
still off, no MEDM screen reading.....meaning
unknown vacuum pressure.We closed PSL shutter
  
  12849   Thu Feb 23 15:48:43 2017 johannesUpdateComputersc1psl un-bootableUsing the PDA520 detector on the AS port
I tried to get some better estimates for
the round-trip loss in both arms. While setting
 scope_PDA520_ITM_aligned_ETM_misaligned.pngscope_PDA520_ITM_slightly_misaligned.pngpmc_trans_last10days.png 
  12851   Thu Feb 23 19:44:48 2017 johannesUpdateComputersc1psl un-bootableYes, that was one of the things that I
wanted to look into. One thing Gautam and
I did that I didn't mention was to reconnect
 slow_startup_logs.tar.gz 
  12852   Fri Feb 24 20:38:01 2017 johannesUpdateComputersc1psl boot-stall culprit identified[Gautam, Johannes]

c1psl finally booted up again,
PMC and IMC are locked.
  
  12854   Tue Feb 28 01:28:52 2017 johannesUpdateComputersc1psl un-bootableIt turned out the 'ringing' was
caused by the respective other ETM still
being aligned. For these reflection measurements
  
  12869   Mon Mar 6 12:34:30 2017 johannesSummaryASSASS light injection scenariosWhat we want from the light source for
the AS port light injection:


Frequency control for locking
  
  12874   Wed Mar 8 18:18:51 2017 johannesUpdateComputer Scripts / Programsloss scriptI started a loss script on Donatella that
will scan the beam spot across ETMY, recording
the reflected power from the arm via the
  
  12879   Thu Mar 9 22:28:11 2017 johannesUpdateComputer Scripts / Programsloss scriptloss map script running on Rossa that moves
the beam on ETMX. Yarm was misaligned for
this, most recent PIT and YAW settings were
  
  12882   Fri Mar 10 19:48:56 2017 johannesUpdateComputer Scripts / Programsloss scriptLoss script running again, on Pianosa this
time. Due to an oversight in the code the
beam wasn't actually moved across ETMY
  
  12883   Sat Mar 11 20:11:58 2017 johannesUpdateComputer Scripts / Programsloss scriptYarm script running on Pianosa. Still working
on visualization of the ETMX lossmap.

  
  12938   Mon Apr 10 18:42:09 2017 johannesUpdateCamerasPylon installation warningIt looks like we may not need to use this
old Pylon version after all. Gautam and I
looked into installing SnapPy with the makefile
  
  12958   Fri Apr 28 22:50:35 2017 johannesUpdateCamerasAttempting to Load Camera ClientYou'll likely have to run camera_server.py
using the same ini file first before you
can use the client. Since the pylon installation
  
  12965   Wed May 3 16:12:36 2017 johannesConfigurationComputerscatastrophic multiple monitor failuresIt seems we lost  monfight.jpg 
  13235   Mon Aug 21 20:11:25 2017 johannesSummaryGeneralLoss measurements planThere are three methods we (will soon)
have available to evaluate the round-trip
dissipative losses in the arms that do not
  
  13241   Tue Aug 22 16:56:54 2017 johannesSummaryGeneralAS laser existing components inventoryI surveyed the lab today to see what we
may need to buy for the AS laser setup.

We
  
  13264   Mon Aug 28 23:22:56 2017 johannesUpdatePSLPSL table auxiliary NPROI moved the axuiliary NPRO to the PSL table
today and started setting up the optics.

The Faraday Isolator was showing
 aom_switching_zoomin.pngaom_switching_zoomout.pngaom_switching_mini_zoomin.pngaom_switching_mini_zoomout.png 
  13271   Tue Aug 29 21:36:59 2017 johannesUpdatePSLPSL table auxiliary NPRO


 isomet_mini_1st_zoomout.pngisomet_mini_0th_zoomout.png 
  13298   Tue Sep 5 23:13:44 2017 johannesUpdatePSLPSL table auxiliary NPROI used Gautam's mode measurement of
the auxiliary NPRO (w=127.3um,
z=82mm) for the spacing of the optics
 PSL_IR.pdfpsl_aux_laser.pdf 
  13299   Wed Sep 6 01:09:11 2017 johannesUpdateComputer Scripts / ProgramsNew set of loss measurementsI
stumbled upon a faster way to stream data from
 XARM_20170905.pdfYARM_20170905.pdf 
  13301   Thu Sep 7 23:09:00 2017 johannesUpdatePSLPSL table auxiliary NPROI brought the DEI Pulser
unit and a suitable Pockels cell
over from Bridge today (I also found an identical
 3200-1113_200_switching_PD10A_zoomin.png3200-1113_200_switching_PD10A_zoomout.png 
  13306   Mon Sep 11 12:40:32 2017 johannesUpdatePSLPSL table auxiliary NPROI changed the PSL table auxiliary laser
setup to the 200 MHz AOM and put the light
back in the fiber. Coupling efficiency is
 psl_aux_laser2.svg.pngPSL_IR2.png 
  13307   Mon Sep 11 12:56:40 2017 johannesUpdateComputer Scripts / Programslossmap attemptsI was trying to get a lossmap measurement
over the weekend but had some trouble first
with the IMC and then with the PMC.
  
  13310   Mon Sep 11 23:31:50 2017 johannesUpdateCameraspost-vent camera capture comparisonThe latest pre-unintended vent captures
of the test mass face cameras were taken
on June
 13x 
  13330   Mon Sep 25 17:56:33 2017 johannesUpdateComputer Scripts / Programstransmitted power during lossmapI had to do a reboot + burt restore of
c1psl today. It was unresponsive and I couldn't
get the PMC to lock. I also had to slightly
  
  13334   Tue Sep 26 22:11:08 2017 johannesUpdateCameraspost-vent camera capture comparisonI configured the remaining GigE-Camera
to work on the 40m network. We currently
have 3 operational Basler cameras:
 lens_distance.pdfImage__2017-09-26__18-54-29.jpgIMG_20170926_190157222_HDR.jpgIMG_20170926_185649325.jpg 
  13348   Mon Oct 2 12:44:45 2017 johannesUpdateCamerasBasler 120gm calibrationDisclaimer: Wrong calibration
factors! See 
 calib_20170930_152.pdfcalib_20170930_153.pdf 
  13354   Tue Oct 3 01:58:32 2017 johannesHowToCamerasCCD calibrationDisclaimer: Wrong calibration
factors! See 
 gige_calibration.pdf 
  13375   Thu Oct 12 01:03:49 2017 johannesHowToCamerasETMX GigE side viewI calculated a better lens solution for
the ETMX side view with the simple python
script that's attached. The camera is
 IMG_20171011_164549698.jpgImage__2017-10-11__16-52-01.pngGigE_lens_position_helper.py.zip 
  13389   Wed Oct 18 11:37:58 2017 johannesHowToCamerasETMX GigE side view at 50 deg


  
  13391   Wed Oct 18 15:26:58 2017 johannesHowToCamerasRevision: CCD calibrationThe units were still off in my previous
post. Here's the corrected, sanity-checked
version:
 calib_20170930_152.pdfcalib_20170930_153.pdf 
  13422   Thu Nov 9 15:33:08 2017 johannesUpdateCDSrevisiting Acromag


  
  13443   Wed Nov 22 00:54:18 2017 johannesOmnistructureComputersSlow DAQ replacement computer progressI got the the SuperMicro 1U server box
from Larry W on Monday and set it up in the
CryoLab for initial testing.
  
  13458   Wed Nov 29 21:40:30 2017 johannesOmnistructureComputersSlow DAQ replacement computer progress[Aaron, Johannes]

We
configured the AtomServer for the Martian
  
  13463   Mon Dec 4 22:06:07 2017 johannesOmnistructureComputersAcromag XEND progressI wired up the power distribution, and
ethernet cables in the Acromag chassis today.
For the time being it's all kind of loose
  
  13464   Thu Dec 7 11:14:37 2017 johannesHowToComputer Scripts / ProgramsLots of red on the FE status screenSince we're getting ready to put the
replacement slow DAQ for c1auxex in I wanted
to bring the IFO back to operating condition
 22.png 
  13466   Thu Dec 7 15:46:31 2017 johannesHowToComputer Scripts / ProgramsLots of red on the FE status screen[Koji, Johannes]

The issue was partially fixed and
the interferometer is in workable condition
 04.png 
  13468   Thu Dec 7 22:24:04 2017 johannesOmnistructureComputersAcromag XEND progress 




 sourcing_input.pngsourcing_to_sourcing_with_common_supply.pngIMG_20171207_193128928.jpg 
  13469   Fri Dec 8 12:06:59 2017 johannesOmnistructureComputersc1auxex2 ready - but need more cablesThe new slow machine c1auxex2
is ready to deploy. Unfortunately we don't
have enough 37pin DSub cables to connect
  
  13470   Fri Dec 8 23:31:31 2017 johannesFrogsASSc1ass slow channel offloading scripts with small While staring at epics records all day
I noticed something about the PIT/YAW offset
sliders and ASS offset offloading to slow
  
  13471   Wed Dec 13 09:49:23 2017 johannesUpdateASSwiring diagramI attached a wiring schematic from the
slow DAQ to the eurocrate modules. Of these,
pins 1-32 (or 1A-16C) and pins 33-64 (17A-32C)
 1Y9.pdf 
ELOG V3.1.3-