40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 239 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  10959   Fri Jan 30 02:57:03 2015 JenneUpdateModern ControlFirst try with PRCL ASC Wiener filtering[Aside - How do you rotate plots in the
new elog?  It's showing them correctly
in the attachments list below the entry,
 9x 
  10967   Tue Feb 3 04:07:49 2015 JenneUpdateModern ControlMeasured PRM -> POP QPD TFsToday (after centering the POP QPD), I
measured the PRM to POP QPD transfer functions. 
I am suspicious that this was part of my
 PIT_measured_TF.pngYAW_measured_TF.png 
  10993   Tue Feb 10 02:55:29 2015 JenneConfigurationModern ControlQuacky filtersI discovered that somehow my Wiener filters
that show up in Foton are not the same as
what I have in Matlab-land. 
 Mismatch_wienerQuackFoton_xaxis_9Feb2015.pngMismatch_wienerQuackFoton_yaxis_9Feb2015.pngMismatch_wienerQuackFoton_zaxis_9Feb2015.png 
  11186   Tue Mar 31 22:27:43 2015 JenneUpdateModern ControlPreliminary PRMI angular Wiener resultsBefore locking for the evening, I wanted
to try again implementing the Wiener
filters that I had designed back
 PRMI_31Mar2015.pdf 
  11202   Sat Apr 4 17:54:03 2015 ranaUpdateModern ControlPreliminary PRMI angular Wiener resultsThis
is a very cool result. I'm surprised
  
  11229   Tue Apr 21 01:17:13 2015 JenneUpdateModern ControlT-240 self-noise propagated through stack and pendulumGoing back to Wiener filtering for a moment,
I took a look at what the T-240 noise level
looks like in terms of pitch motion on one
 T240selfnoise.pngLimits.tar.gz 
  11310   Tue May 19 14:51:44 2015 ericqUpdateModern ControlBrushing up on Wiener FilteringAs part of preparing for the SURF projects
this summer, I grabbed ~50 minutes of MCL
and STS_1 data from early this morning to
 mclData.pngmclWiener.zip 
  11313   Tue May 19 17:53:38 2015 ranaUpdateModern ControlBrushing up on Wiener FilteringGood to see that misofw.m is still alive
and well. Todo:


Apply weighting to the
  
  14603   Fri May 10 18:24:29 2019 gautamUpdateNoiseBudgetaligoNBI pulled the aligoNB git repo to /ligo/GIT/aligoNB/aligoNB.   
  15047   Mon Nov 25 22:10:26 2019 shrutiUpdateNoiseBudgetDiagnostics This is to help troubleshoot the excess
noise measured earlier.

The following channels were measured
 LSC.pdfITMY.pdfITMX_L.pdf 
  15300   Tue Apr 7 15:30:40 2020 JonSummaryNoiseBudget40m noise budget migrated to pygwincIn the past year, pygwinc has expanded
to support not just fundamental noise calculations (e.g.,
quantum, thermal) but also any number of
  
  16152   Fri May 21 12:12:11 2021 PacoUpdateNoiseBudgetAUX PDH loop identification[Anchal, Paco]

We went into 40m to identify where
XARM PDH loop control elements are. We didn't
  
  16975   Wed Jul 6 19:58:16 2022 PacoSummaryNoiseBudgetXARM noise budget[Anchal, Paco, Rana]

We locked the XARM
using POX11
 xarm_nb_2022_07.pdf 
  5   Fri Oct 19 16:11:38 2007 pkpOtherOMCOMC PZT responseSam and I locked the laser to the OMC cavity
and looked at the error signal as a function
of the voltage applied to the OMC PZT.
 fullspec.jpg4.5to10.jpg4.5to10.pdffullres.pdf 
  6   Sat Oct 20 11:54:13 2007 waldmanOtherOMCOMC and OMC-SUS work[Rich, Chub, Pinkesh,  Chris,  Sam]

Friday the 18th was a busy day in OMC land.
  
  8   Mon Oct 22 19:27:14 2007 pkpOtherOMCPZT calibration/ transfer function.We measured the PZT transfer function by comparing
the PZT response of the circuit with the
cavity in the loop, with that of the circuit
 calib.pdfcalibpzt2.pdfall2.pdfnoPZT2.pdf 
  9   Tue Oct 23 09:01:00 2007 ranaOtherOMCPZT calibration/ transfer function.Are you sure that the error signal sweep is
not saturated on the top ends? This is usually
the downfall
  
  14   Thu Oct 25 17:52:45 2007 waldmanOtherOMCOMCs with QPDs[Rich, Chub, Pinkesh, Sam]

Yesterday we got the QPD, OTAS, and PZT cabling
  
  16   Thu Oct 25 23:35:36 2007 waldmanOtherOMCHang the OMC![Pinkesh, Sam]

We tried,  convicted and hung the OMC today.
 IMG_1483.jpgIMG_1481.jpg 
  19   Fri Oct 26 17:34:43 2007 waldmanOtherOMCOMC + earthquake stops
[Chub, chris, Pinkesh, Sam]
  
  20   Fri Oct 26 21:48:40 2007 waldmanConfigurationOMCFiber to 056I set up a 700 mW NPRO in Rana's lab and launched
it onto a 50m fiber.  I got a few mW onto
the fiber,  enough to see with a card before
  
  21   Sat Oct 27 19:00:44 2007 waldmanConfigurationOMCHanging, locked OMC with REFL extracted.I got the OMC locked to the fiber output today.
 It was much more difficult than I expected
and I spent about 30 minutes or so flailing
  
  25   Mon Oct 29 11:07:22 2007 waldmanSoftware InstallationOMCSoftware install on OMS[Alex, Sam]

We spent a little time this morning working
  
  26   Mon Oct 29 12:20:15 2007 waldmanConfigurationOMCChanged OMS filtersI changed the OMS configuration so that some
of the OMC-SUS LED channels go to a breakout
box so that we can input the PDH error signal.
  
  27   Mon Oct 29 23:10:05 2007 waldmanConfigurationOMCLost in DAQspace[Pinkesh, Sam]

In setting up a Digital based control of
 SS.pdfSS.gif 
  37   Wed Oct 31 09:45:28 2007 waldmanOtherOMCResolution to DAQland saga[Jay, Sam]

We did a rough accounting for the linear
  
  42   Wed Oct 31 23:55:17 2007 waldmanOtherOMCQPD testsThe 4  QPDs for the OMC have been installed
in the 056 at the test setup.  All 4 QPDs
work and have medm screens located under
 QPD_SignalSpectrum.pdfQPD_SignalSpectrum.gif 
  43   Thu Nov 1 01:28:04 2007 waldmanOtherOMCFirst digital lock of OMC[Pinkesh, Sam]

We locked a fiber based NPRO to the suspended
 071101_PZT_firstLoopSweep.pdf071101_PZT_firstLoopSweep.gif071101_OMC_FirstLock_spectra.pdf071101_OMC_FirstLock_spectra.gif 
  58   Fri Nov 2 12:18:47 2007 waldmanSummaryOMCLocked OMC with DCPD[Rich, Sam]

We locked the OMC and look at the signal
 071102_OMC_LockedDCPD.gif071102_OMC_LockedDCPD.pdf 
  59   Sat Nov 3 16:20:43 2007 waldmanSummaryOMCA good day's work
I followed up yesterday's test of the PZT
with a whole mess of characterizations of
 6x 
  60   Sun Nov 4 23:22:50 2007 waldmanUpdateOMCOMC PZT and driver response functionsI wrote a big long elog and then my browser
hung up,  so you get a less detailed entry.
 I used Pinkesh's calibration of the PZT
 7x 
  63   Mon Nov 5 14:44:39 2007 waldmanUpdateOMCPZT response functions and De-whiteningThe PZT has two control paths:  a DC coupled
path with gain of 20,  range of 0 to 300
V,  and a pair of 1:10 whitening filters,
 07110_DithertoVmonAC_sweep2-0.png071105_LSCtoVmonDC_sweep4-0.png07110_DithertoVmonAC_sweep2.pdf071105_LSCtoVmonDC_sweep4.pdf 
  79   Wed Nov 7 14:01:31 2007 waldmanOmnistructureOMCFrequency and Intensity noiseOne of the biggest problems I had using the
PZT to lock was excessive noise.  I did a
little noise hunting and found that the problem
  
  82   Thu Nov 8 00:55:44 2007 pkpUpdateOMCSuspension tests[Sam , Pinkesh]

We tried to measure the transfer functions
 9x 
  86   Fri Nov 9 00:01:24 2007 waldmanOmnistructureOMCOMC mechanical resonances (Tap tap tappy tap)[Pinkesh, Aidan, Sam]

We did a tap-tap-tappy-tap test of the OMC
 7x 
  87   Fri Nov 9 00:23:12 2007 pkpUpdateOMCX and Z resonancesI got a couple of resonance plots going for
now. I am still having trouble getting the
Y measurement going for some reason. I will
 Xtransferfunc.pdfZtransferfunc.pdf 
  93   Mon Nov 12 10:53:58 2007 pkpUpdateOMCVertical Transfer functions[Norna Sam Pinkesh]

These plots were created by injected white
 VerticalTrans.pdf 
  99   Wed Nov 14 07:48:38 2007 nornaOmnistructureOMCOMC Cable dressing[Snipped from an email]

1) Last Friday Pinkesh and I set the OMC
 OMC-11-13-07_011.jpgVerticalTrans.pdf 
  102   Wed Nov 14 16:54:54 2007 pkpUpdateOMCMuch better looking vertical transfer functions[Norna Pinkesh]

So after Chub did his wonderful mini-surgery
 VerticalTransPreampwireremovedNov142007.pdfVerticalTranswiresclampedNov142007.pdf 
  105   Thu Nov 15 17:09:37 2007 pkpUpdateOMCVertical Transfer functions with no cables attached.[Norna Pinkesh]

The cables connecting all the electronics
 VerticaltransferfuncnocablesattachedNov152007.pdf 
  179   Fri Dec 7 11:33:24 2007 waldmanOmnistructureOMCPZT wiringThe 2 pin LEMO connector has got an unmarked
pin and a pin marked by a white half-circle.
The unmarked pin is connected to the side
  
  206   Thu Dec 20 19:05:34 2007 waldmanHowToOMCHOWTO build front endsFor instance,  to build the TPT front end
code.
  
  207   Thu Dec 20 19:10:03 2007 waldmanUpdateOMCStressful reattachment of heaterPhotos may follow eventually,  but for now
here's the rundown.  I scraped the heater
clean of the thermal epoxy using a clean
  
  1888   Tue Aug 11 23:55:04 2009 rana, richSummaryOMCQuantum Efficiency and Dark Current measurements of eLIGO PhotodiodesRich Abbott, Rana
Summary: We found that the 3mm
InGaAs photodiodes from eGTRAN which are
 IMG_0135.png 
  1958   Thu Aug 27 16:14:28 2009 steveSummaryOMCburned photodiodeOld -pre 6/2009  LLO DCPD 3 mm od
GTRAN photodiode
 20090827_173252.jpg20090827_170802.jpg 
  2095   Thu Oct 15 02:38:10 2009 rana, robUpdateOMCDark Port Mode Scan using the OMCBottom trace is proportional to the OMC
PZT voltage - top trace is the transmitted
light through the OMC. Interferometer is
 OMC-ModeScan_091015.png 
  8849   Mon Jul 15 16:44:46 2013 AlexUpdateOMCOMC North Safety [Eric Alex]
We are planning on testing our laser
module soon, so we have added aluminum foil
 photo_2_(1).JPG 
  14022   Tue Jun 26 20:59:36 2018 aaronUpdateOMCprep for vent in a couple weeksI checked out the elog from the vent in
October 2016 when the OMC was removed from
the path. In the vent in a couple weeks,
  
  14051   Wed Jul 11 15:57:00 2018 aaronUpdateOMCReviving OMC electronicsGautam showed me the electronics racks
for the OMC PZTs and DAQ. I'm in the
process of chasing down what channels we
  
  14052   Wed Jul 11 16:23:21 2018 aaronUpdateOMCCoordination of the Output Mode-cleaner Mirror Insertion Expedition (COMMIE)I started this document on my own with
notes as I was tracing the beam path through
the output optics, as well as some notes
  
ELOG V3.1.3-