    Reply  Wed Nov 23 00:00:53 2011, Zach, Summary, Green Locking, Some issues on the Y end green PDH locking 


    
        
            Quote:
        
        
            

           (AM transfer function)
Entry  Mon Feb 2 17:25:44 2009, Alberto, Configuration, General, Some little problem with the new elog 
For some reason the new elog does not look exactly like it should. 

1) Some of the editing features are not available.

2) The Reply option opens the
HTML of the message by default.

I think this is happening because Nodus is a Sun of platform and things are a little bit different from linux.

I'm
working to fix these things. If I make any change and need to restart the elog, I'll try to be very quick.

I apologize for the inconveniences.
    Reply  Mon Feb 2 18:32:54 2009, Alberto, Configuration, General, Some little problem with the new elog 


    
        
            Quote:
        
        
            For some reason the new elog does not look exactly like it should.   1) Some of the editing features are not available.  2) The Reply
Entry  Mon Sep 7 23:18:01 2009, Alberto, Update, Locking, Some locking attempts 
Tried to lock the interferometer but arm power didn't get over 65.
Tonight, after the weekend, I resumed the work on locking.
When I started the Mode Cleaner was unlocked because the MZ was also unlocked.
Entry  Tue Mar 3 19:11:48 2020, gautam, Update, LSC, Some locking prep 

Re-aligned and locked the arm cavities for IR and green.
Re-set trans normalization because after the c1iscex and c1iscey reboots,
these didn't come back to the old values.
Entry  Tue Feb 10 02:40:54 2015, Jenne, Update, LSC, Some locking thoughts on PRMI 
[EricQ, Jenne]

We wanted to make the PRMI lock more stable tonight, which would hopefully allow us to hold lock much longer.  Some success, but nothing
out-of-this-world.
    Reply  Tue Feb 10 03:09:02 2015, ericq, Update, LSC, Some locking thoughts on PRMI 
Unfortunately, we only had one good CARM offset reduction to powers of about 25, but then my QPD loop blew it. We spent the vast majority of the night
dealing with headaches and annoyances. 

Things that were a pain:
Entry  Fri Oct 31 19:59:26 2014, Koji, Update, General, Some locking work / PRMI analysis PRMIsb_PRCL_OLTF.pdfPRMIsb_MICH_OLTF.pdfPRMIsb_PRCL_SPE.pdfPRMIsb_MICH_SPE.pdf
Preparations
- According to Diego's report, the MC WFS gains were too high. We'll fix this later by tweaking the servo shapes.
But for now, all of the WFS gains were reduced by 40%.
Entry  Sat Jan 17 01:10:36 2015, Jenne, Update, LSC, Some locking, may need to modify UGF part again 
I have been playing with the IFO tonight.  Mostly, I wanted to make sure that all of the scripts for the carm_cm_up sequence were working, and they
seem to all be fine. 

I also turned on all 4 UGF servos.  My big ah-ha moment for the night
    Reply  Tue Jan 20 21:58:04 2015, diego, Update, LSC, Some locking, may need to modify UGF part again UGF_SERVO_MDL.png
 




Quote:



I have been playing with
Entry  Tue Nov 18 15:20:58 2014, Jenne, Update, LSC, Some lockloss plots from PRFPMI 8x
Elog from ~5am last night:
Tonight was just several trials of PRFPMI locking, while trying to pay more attention to the lockloss plots each time.
General notes:  
    Reply  Tue Nov 18 17:11:30 2014, Jenne, Update, LSC, Some lockloss plots from PRFPMI 
I am still staring at / trying to figure out the latter 4 locklosses posted earlier.  But, I have just included the transmission QPD angular output
signals to the frames, so we should be able to look at that with locklosses tonight. 
To get the lockloss plots:  in ..../scripts/LSC/LocklossData/ , first
Entry  Tue Mar 31 02:51:39 2015, ericq, Update, LSC, Some locks 
I had a handful of ~10 minute locks tonight. I intended to work on the 1f PRMI transition, but ended just familiarizing myself with the current scheme. 

Before touching anything, I committed the locking scripts to the svn. Unfortunately, the up script as I found it never worked for me tonight.
I had to reintroduce the digitial crossover helper in CM_SLOW to get past the ramping up of the overall REFL11 gain. (With this is in place, there is some
    Reply  Tue Mar 31 03:02:44 2015, Koji, Update, LSC, Some locks 
Assuming the carrier mode in PRC is stable and the SB is the one moving, can we just use the POP DC QPD to control PRM?

Can we plot the arm power trend for multiple locks to see if it is associated with any thermal phenomenan in the IFO?
They should be able to fit with an exp + DC.
    Reply  Tue Mar 31 18:27:58 2015, ericq, Update, LSC, Some locks qpdSwitch.pngqpdAlways.png



Quote:



Can we plot the arm power
trend for multiple locks to see if it is associated with any thermal phenomenan in the IFO?
Entry  Thu Jun 24 13:02:59 2010, Jenne, Update, Computers, Some lunchtime reboots 
[Jenne, Megan, Frank]
We rebooted c1iovme, c1susvme1, and c1susvme2 during lunch.  Frank is going to write a thrilling elog about why c1iovme needed some attention.
C1susvme 1&2 have had their overflow numbers on the DAQ_RFMnetwork screen red at 16384 for the past few days.  While we were booting computers
Entry  Wed Mar 25 18:27:34 2015, Koji, Summary, General, Some maintainance 
- I found that the cable for the AS55 LO signal had the shielding 90% broken. It was fixed.

- The Mon5 monitor in the control room was not functional for months. I found a small CRT down the east arm.
It is now set as MON5 showing the picture from cameras. Steve, do we need any safety measure for this CRT?
Entry  Tue May 12 12:04:41 2015, manasa, Update, General, Some maintenance 
* Relocked IMC. I guess it was stuck somewhere in the autlocker loop. I disabled autolocker and locked it manually. Autolocker has been
reenabled and seems to be running just fine.

* The X arm has been having trouble staying locked. There seemed to be some amount of gain peaking. I reduced
Entry  Sun May 3 22:48:12 2009, Yoichi, Update, Locking, Some measurements at the lock point ArmPowerTrend.pngCARMSweep.pngCM-AO-Loop-SB1.png
I attached some measurement results at when the IFO is at the full lock point.

The first plot shows the trend of the arm powers after the interferometer was locked.
Entry  Wed Feb 25 04:21:58 2015, ericq, Update, CDS, Some model updates 
I changed the suspension library block to acquire the SUS_[optic]_LSC_OUT channels at 16k for sensing matrix investigations. We could save the FB some
load by disabling these and oplev channels in the mode cleaner optic suspensions. 

I removed nonexistant PDs from c1cal, to try and speed it up from its constantly overflowing state. It's still pretty bad, but under 60us
Entry  Fri Sep 12 03:49:57 2014, ericq, Update, LSC, Some more PRFPMI efforts 
 Since DRMI didn't get fully commissioned, I tried my hand at PRFPMI locking with the newly improved ALS performance. 
ALS seemed reliable, I think my main limiting factor was the PRMI locking. We should set up a restore script for PRFPMI that is a superset of the
ALS CARM DARM, because the current restore script doesn't put all the vertex settings back, so I was trying to lock for a while without the FM boosts on
    Reply  Wed Nov 23 12:58:33 2022, Yehonathan, Update, BHD, Some more calculations LO_phase_sens_vs_LO_phase_RF.pdfLO_phase_sens_vs_LO_phase_RF_fixed_demod.pdfLO_phase_sens_vs_MICH_Offset.pdf
Changed the BHD BS transmissivity to 0.56.

Demodulation Phases

As was noted before. The LO phase sensitivity plot vs LO phase from the previous elog shows the optimal sensitivity at each LO phase. That means
    Reply  Wed Nov 23 17:28:39 2022, Yehonathan, Update, BHD, Some more calculations Fields_at_BHDBS.pdf
Fields at the BHD BS. More on this later.
Entry  Fri Aug 28 23:33:38 2020, gautam, Update, BHD, Some more hardware changes 
Just a quick set of notes detailing changes so that there are no surprises, more details to follow.


Trek driver has been temporarily placed on top of the KEPCO supply east of the OMC electronics rack. Cabling to it has been laid out
as well. I turned both off so neither should be energized now.
A new AI chassis (and associated cabling including the DAC SCSI cable and +/-24
    Reply  Tue Oct 12 17:10:56 2021, Anchal, Summary, CDS, Some more information 
Chris pointed out some information displaying scripts, that show if the DAQ network is working or not. I thought it would be nice to log this information
here as well.


controls@fb1:/opt/mx/bin 0$ ./mx_info
MX
Entry  Thu Feb 17 13:20:06 2011, Suresh, Update, VIDEO, Some more labels 
[Larisa, Kiwamu, Steve and Suresh]
 
  We continued the labeling of video cables. All exiting cables which are going to be used used in the new scheme have been labeled.
Entry  Sat Nov 19 15:58:04 2011, Mirko, Update, IOO, Some more looks into OSEM noise 8x
[Den, Mirko]
We looked some more into the the OSEM signals and their coherence to the seismometer signals.
We were able to verify that the coherence OSEM sensor <-> seismometer signal goes down with increasing the OSEM gain. This seems to indicate
    Reply  Tue Jul 7 14:06:10 2020, gautam, Update, ASC, Some more thoughts about ASC ITM_OL_DCcoupling.png
Summary:

I want to be able to run the dither alignment servo with the PRFPMI locked - I've been thinking about what the scheme should be, and I list
here some questions I had while thinking about this.
    Reply  Sun Jun 24 20:02:07 2018, gautam, Update, SUS, Some notes about coil driver noise CoilDriverSchematic.pdfD010001_2k_fastOnly_2.25k.pdfD010001_4k_fastOnly_4.5k.pdf
Summary:

For a series resistance of 4.5 kohm, we are suffering from the noise-gain amplified voltage noise of the Op27 (2*3.2nV/rtHz), and the Johnson
noise of the two 1 kohm input and feedback resistances. As a result, the current noise is ~2.7 pA/rtHz, instead
    Reply  Wed Sep 2 00:49:47 2020, gautam, Update, BHD, Some notes about homodyne phase heterodyneMICH.pdfunwrappedPhase.pdfunwrappedPhase_zoom.pdfphaseNoisePSD.pdf
Summary:

Using a heterodyne measurement setup to track both quadratures, I estimated the relative phase fluctuation between the LO field and the interferometer
output field. It may be that a single PZT to control the homodyne
    Reply  Tue Nov 18 22:34:28 2014, Jenne, Update, LSC, Some other plots from PRFPMI TRXmax98_TRYmax107_CARMdarmOnALS_0carmOffset.pngZoom_with_POP22.pngZoom_with_POP110.pngZoom_with_ErrSigs.png


    
        
            Quote:
        
        
            

           I was able to  hold the PRMI on REFL33I&Q, and have ALS CARM and DARM at zero CARM  offset.  The arm would "buzz" through
    Reply  Mon Sep 30 17:04:30 2019, gautam, Update, CDS, Some path changes 
I made some model changes to c1lsc. To propagate the changes, I tried the usual rtcds make sequence. But I got an error about the model file not being
in the path. This is down to my re-organization of the paths to cleanly get everything under git version control. So I had to run the following path modification.
Where is this variable set and how can I add the new paths to it? The model compilation, installation
    Reply  Tue Sep 8 11:49:04 2020, gautam, Update, CDS, Some path changes 
I edited /diskless/root.jessie/home/controls/.bashrc
so that I don't have to keep doing this every time I do a model recompile.




Quote:


Entry  Wed Jan 20 20:11:56 2010, Alberto, Update, ABSL, Some preliminary results from measuring PRC's transmissivity for an amplitude modulated beam 2010-01-19_PRCtransmissivityVsModel.png
Here I'm posting a plot showing a set of measurements that I made in the past few days to determine the absolute length of the PRC cavity.
As
in my other AbsL measurements, I inject an auxiliary laser beam into the cavity and look at the transmission. In the PRC case, the beam is injected through
the dark port and I look at a pick-off of the REFL beam. The aux laser is phase locked to the PSL beam and I control the differential frequency between
    Reply  Thu Jan 21 10:31:13 2010, Koji, Update, ABSL, Some preliminary results from measuring PRC's transmissivity for an amplitude modulated beam 
Nice and interesting plot.

I suppose slight decrease of the Schnupp asymmetry (in your model) adjusts the discrepancy in the high freq region.
Entry  Mon Mar 22 16:29:17 2021, gautam, Update, ASC, Some prep for AS WFS commissioning AS_WFS_head.pngWFSquads.pdf

Added rough cts2mW calibration filters to the quadrants, see Attachment
#1. The number I used is:
          0.85 A/W         *       500 V/A         
    Reply  Fri Mar 13 00:32:38 2020, gautam, Update, LSC, Some progress RFonly_CARM.pngCARMTF.pdf
Finally, some RF only CARM, see Attachment #1.
During this time, DARM was also on a blend of IR and ALS control, but I couldn't turn the ALS path off in ~4-5 attempts tonight (mostly me pressing
a wrong button). Attachment #2 shows
Entry  Fri Sep 25 16:10:17 2009, Jenne, Update, Adaptive Filtering, Some progress on OAF, but more still to be done OAF_Running_25Sept2009.jpg
[Jenne, Sanjit]
It seems now that we are able to get the OAF system to do a pretty good job of approximating the MC_L signal, but we can't get it to actually do
any subtracting.  I think that we're not correctly setting the phase delay between the witness and the MC_L channels or something (I'm not sure though
Entry  Wed Nov 24 18:11:26 2010, Jenne, Update, PEM, Some progress on getting PEM channels 
I have made a little bit of progress on the PEM channels.  I have begun writing up detailed instructions in the
DAQ Wiki page on how to add a channel to the new DAQ system.  I have followed those instructions thus far, and can see my channels in the .ini
file (and in the daqconfig gui thing), but I don't have any channels in Dataviewer or DTT.  
Entry  Fri Oct 16 12:40:59 2009, Koji, Configuration, General, Some questions 
Some questions came arise to me:
A. How the green injection system should be? How the handing off between 532 and 1064 should be?
This is not new, though. It would be worth reminding.
Entry  Thu Apr 17 17:27:32 2014, ericq, Update, LSC, Some reference Plots carm2TRX.pdfcarmSignalLevels.pdf
Jenne made some suggestions for some plots that would be useful on our CARM offset reduction adventures, so I made some with my MIST model. 
First, here's a plot showing the transfer function of CARM to TRX, with logarithmically spaced offsets out to 3nm. While not a control signal,
it shows us where the optical plant resonance stuff is happening. The peaks in this TF correspond to peaks in REFL11, REFL55, AS11, etc., as in the close-to-resonance
Entry  Wed Sep 14 20:30:36 2011, rana, Update, SUS, Some screens are still bad Untitled.png
I've found that a few of the screens still have Whited-Out fields due to naming changes (OL SUM and ALS-> TM OFFSET). I attach a screen shot of it.
The OL screens have the wrong SUM names and the IFO ALIGN screen is pointing to the wrong SUS screens.
    Reply  Fri Sep 16 17:46:13 2011, kiwamu, Update, SUS, Some screens fixed 
The bad medm screens have been fixed. There are no blank fields and all the links are correct.  


    
        
            Quote from #5409
    
    Reply  Mon Sep 19 17:45:39 2011, rana, Update, SUS, Some screens fixed Untitled.png


    
        
            Quote:
        
        
            
            Kiwamu:       The
    Reply  Fri Feb 7 02:24:24 2020, gautam, Update, LSC, Some short notes 
[koji, gautam] 

Plots + interpretation tomorrow.


CM_Slow path can be used to stabilize the arm powers somewhat but the AO crossover remains out of reach.
The REFL11 (=CARM_B)
Entry  Fri Apr 10 03:44:51 2015, Jenne, Update, LSC, Some small progress, may have DAC problem? PRMI_sb_powers_9Apr2015.png
Small steps tonight, but all in the forward direction.

On one of my better locks, I saw a kind of weird phenomenon with the PRMI sideband powers versus the carrier powers:

    Reply  Fri Apr 10 12:09:19 2015, ericq, Update, LSC, Some small progress, may have DAC problem? 




Quote:



At the very end,
the last 10 seconds or so, the POP110 power goes down, and sits at about half it's maximum value.  POP22 isn't quite as bad, in that it still
Entry  Fri Nov 20 17:44:38 2009, Jenne, Update, Adaptive Filtering, Some svn shenanigans 
[Sanjit, Jenne]
Sanjit and I are trying to put names to some signals which exist in SimuLink land, but which don't (yet) exist in EPICS land.  The deelio
is that for each of the chosen SEIS signals in the ASS_TOP_PEM screen, the signal is split.  One part of the signal is used to decide how the adaptive
Entry  Wed Nov 18 22:49:06 2020, gautam, Update, ASC, Some thoughts about AS WFS electronics 
Where do we want to install the interface and readout electronics
for the AS port WFS? Options are:


1Y1 / 1Y3  (i.e. adjacent to the LSC rack) - advantage is that 55 MHz RF signal is readily available for demodulation. But
    Reply  Wed Nov 25 18:30:23 2020, gautam, Update, ASC, Some thoughts about AS WFS electronics 
An 8 channel whitening chassis was prepared and tested. I measured:


TF from input to output - there are 7 switchable stages (3 dB, 6 dB, 12 dB and 24 dB flat whitening gain, and 3 stages of 15:150 Hz z:p
whitening). I enabled one at a time and measured the TF. 
Noise with input terminated.


In summary,