ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
5517
|
Thu Sep 22 13:45:17 2011 |
Paul | Update | SUS | ETMX actuator response fits | Fitting results:
Pitch
-- Fit completed after 305 iterations--
Started |
 |
5516
|
Thu Sep 22 11:50:37 2011 |
Koji | Update | LSC | Locking status update | Both loops basically have no phase margins.
i.e. unstable. How can you lock PRMI with
these servos? |
|
5515
|
Thu Sep 22 11:49:05 2011 |
kiwamu | Update | LSC | some LSC scripts don't run on pianosa | Found some LSC scripts didn't run on pianosa.
Particularly all the scripts on the C1:IFO_CONFIGURE
screen don't run. |
|
5514
|
Thu Sep 22 10:43:50 2011 |
Paul | Update | SUS | Power spectrum with different filter gains | I thought it might be informative
before trying to optimise the filter design
to see how the current one performs with |
|
5513
|
Thu Sep 22 04:49:14 2011 |
Anamaria | Update | LSC | Locking status update - Some Scripts, No Louck | The scripts I wrote can be found in /users/anamaria/scripts/sensemat/
]There are two of them:
- one that sets all the switches, |
|
5512
|
Thu Sep 22 01:45:41 2011 |
Keiko | Update | LSC | Locking status update | Keiko, Anamaria
Tonight we want to measure the LSC
matrix for PRMI and compare the simulation |
 |
5511
|
Thu Sep 22 01:05:28 2011 |
Katrin | Update | Green Locking | New modulation frequency (Y arm) | [Kiwamu / Katrin]
On Wednesday, the green light was |
|
5510
|
Thu Sep 22 00:00:10 2011 |
Paul | Update | SUS | ITMY and SRM actuator response functions - complex fitting results | Here are the results of the complex fitting.
The residuals are bigger this time, but still
probably small enough to be ok(?), with the |
   |
5509
|
Wed Sep 21 23:44:45 2011 |
Paul | Update | SUS | Re:ITMY and SRM actuator response functions - fitting results |
|
|
5508
|
Wed Sep 21 23:25:51 2011 |
kiwamu | Update | SUS | Re:ITMY and SRM actuator response functions - fitting results | Did you take the 180 deg shift into your
account ?
Since your measurement was done when |
|
5507
|
Wed Sep 21 23:05:16 2011 |
Paul | Update | SUS | ITMY and SRM actuator response functions - fitting results | I used an fminsearch function to
fit the SRM and ITMY actuator response magnitudes.
The testfunction was just that for a single |
   |
5506
|
Wed Sep 21 21:13:35 2011 |
rana | Update | IOO | AM modulation misery | How about changing the x-axis of all these
plots into meters or picometers and tell
us how wide the PRC resonance is? (something |
|
5505
|
Wed Sep 21 19:20:41 2011 |
Suresh | Update | IOO | PSL beam into MC was off in Pitch. Readjusted. | I found the PSL beam into the MC off in
pitch by large amount. I readusted
the PSL beam for optimal coupling. |
|
5504
|
Wed Sep 21 18:53:03 2011 |
Keiko | Update | IOO | AM modulation misery | The signal
offset due to the AM modulation is estimated
by a simulation for PRCL for |
  |
5503
|
Wed Sep 21 17:42:35 2011 |
rana | Update | IOO | AM modulation misery | I'd like to see some |
|
5502
|
Wed Sep 21 16:44:18 2011 |
Keiko | Update | IOO | AM modulation mistery | AM
modulation depths are found to be 50 times smaller |
 |
5501
|
Wed Sep 21 16:31:28 2011 |
Paul | Update | SUS | ITMY and SRM actuator response functions | I divided the open loop transfer
functions by the filter response and the
sensor responses (previously measured calibration |
   |
5500
|
Wed Sep 21 16:22:14 2011 |
rana | Update | SUS | Summary screen | The SUS SUMMARY screen is now fully |
|
5499
|
Wed Sep 21 14:44:25 2011 |
Paul | Update | SUS | ITMY and SRM open loop transfer functions |
Here are the open loop transfer
functions for ITMY and SRM. The various settings |
|
5498
|
Wed Sep 21 14:28:25 2011 |
Koji | Summary | LSC | The LSC code/screen modification for LSC LOCKINs | The
LSC code has been modified
-
The code was modified, compiled, and installed. |
|
5497
|
Wed Sep 21 11:35:07 2011 |
steve | Update | VAC | RGA scan | RGA scan with maglev pumping speed at day
14 of the pump down.
The larger inserted box contains |
|
5496
|
Wed Sep 21 09:10:15 2011 |
Paul | Update | SUS | ITMY and SRM oplev calibrations - measured and estimated |
|
|
5495
|
Wed Sep 21 02:49:39 2011 |
Keiko | Summary | LSC | LSC matrices | I created 3 kinds of LSC matrices, PRMI condition
with carrier resonant in PRC, PRMI condition |
|
5494
|
Wed Sep 21 00:37:01 2011 |
rana | Update | SUS | ITMY and SRM oplev calibrations - measured and estimated | I found that some of the Optical Lever
Servos were ON today and injecting nonsense
into the interferometer optics. I have set |
|
5493
|
Wed Sep 21 00:34:29 2011 |
rana | Update | SUS | SUS diag stuff... just so I remember what I'm doing | ETMX was ringing up when it was mis-aligned
for Y arm locking. I restored the input matrix
to something more diagonal and its now damping |
|
5492
|
Tue Sep 20 23:59:53 2011 |
Koji | Summary | LSC | Plan to update the LSC code for multiple lock-ins | DRMI team needs to use at least three lockins
on LSC
Increase the number |
|
5491
|
Tue Sep 20 23:01:37 2011 |
Keiko | Update | IOO | AM modulation mistery | Keiko, Suresh
AM modulations are still there ... the |
|
5490
|
Tue Sep 20 21:13:39 2011 |
Suresh | Update | IOO | MC aligned and PSL beam into MC readjusted | This morning after Kiwamu maximised the
PSL beam coupling into the MC we noticed
that the MC2 face camera showed the spot |
|
5489
|
Tue Sep 20 20:58:35 2011 |
Anamaria | Configuration | LSC | New AP Table Drawing | As promised, I have made a final AP table
drawing, including the MC camera relocation
changes by Kiwamu. I have posted it in the |
|
5488
|
Tue Sep 20 19:00:49 2011 |
Paul | Update | SUS | ITMY and SRM oplev calibrations - measured and estimated |
Kiwamu noticed that the 1/L in the
counts per radian should have just been L, |
|
5487
|
Tue Sep 20 18:03:45 2011 |
Paul | Update | SUS | ITMY and SRM oplev calibrations - measured and estimated | The measured calibration factors for the
oplevs are as follows:
SRM pitch: 666urad |
|
5486
|
Tue Sep 20 17:45:30 2011 |
kiwamu | Update | CDS | daqd is restarting by hisself ? | [Jenne / Kiwamu]
Fb
was sick. Dataviewer and Fourier Tools didn't |
|
5485
|
Tue Sep 20 16:45:09 2011 |
Jenne | Update | SUS | SUS diag stuff... just so I remember what I'm doing | Has the Q been checked? Still
in progress...
|
|
5484
|
Tue Sep 20 16:38:25 2011 |
Keiko | Update | IOO | Small modulation depth | Resonator
box and the modulations are back now. But
the modulation depth seems to be a bit smaller |
|
5483
|
Tue Sep 20 16:31:24 2011 |
Keiko | Update | IOO | Small modulation depth | Modulation
resonator box is removed and the modulation |
|
5482
|
Tue Sep 20 15:54:42 2011 |
kiwamu | Update | Cameras | MC refl camera is available | [Suresh / Kiwamu]
The
MC REFL camera is now available. The camera |
|
5481
|
Tue Sep 20 15:39:57 2011 |
Koji | Update | SUS | free swinging test in vacuum condition | Can't we use Yuta's auto-Q adjust script?
http://nodus.ligo.caltech.edu:8080/40m/3723
Edit by KI : |
|
5480
|
Tue Sep 20 15:23:16 2011 |
Jenne | Update | SUS | free swinging test in vacuum condition | This is using data for the SRM from: 20
Sept 2011 03:20:00 PDT = 1000549215
You can see that there are still |
|
5479
|
Tue Sep 20 14:53:13 2011 |
Jenne | Update | SUS | Jenne's Scripts started |
|
|
5478
|
Tue Sep 20 13:57:44 2011 |
kiwamu | Update | IOO | incident beam to MC aligned | Since the MC wasn't able to capture the
00 mode in this morning I aligned the incident
beam going to MC. |
|
5477
|
Tue Sep 20 09:44:44 2011 |
Jenne | Update | SUS | Jenne's Scripts started |
|
|
5476
|
Tue Sep 20 04:12:26 2011 |
Jenne | Update | SUS | Jenne's Scripts started |
|
|
5475
|
Tue Sep 20 03:12:14 2011 |
Anamaria | Update | SUS | Jenne's Scripts started | I followed Jenne's instructions, ran the
matrix filler script and then set the optics
to freeswing. Someone has to burt resture |
|
5474
|
Tue Sep 20 03:02:23 2011 |
Keiko | Update | LSC | locking activity tonight | Keiko,
Anamaria, Koji
We |
|
5473
|
Tue Sep 20 02:21:10 2011 |
Koji | Update | LSC | LSC MEDM screen cleaning up | I have made some cleaning up of the LSC-related
MEDM screens.
- LSC overview screen: ADC OVFL and |
|
5472
|
Mon Sep 19 23:19:40 2011 |
Keiko | Update | IOO | AM modulation mistery | Keiko, Anamaria
We started to investigate the AM
modulation mistery again. Checking just after |
|
5471
|
Mon Sep 19 22:47:44 2011 |
Jenne | Update | SUS | SUS diag stuff... just so I remember what I'm doing | The last person out tonight should
run the following scripts:
In Matlab: |
|
5470
|
Mon Sep 19 21:19:25 2011 |
Katrin | Update | Green Locking | Broadband photodiode characterization | Another Hamasutu S3399 photodiode was tested
with the electronic circuit as described
in LIGO-D-1002969-v. |
    |
5468
|
Mon Sep 19 20:56:36 2011 |
Paul | Summary | SUS | Remaining SRM and ITMY OSEMs calibrations |
I've now taken data for the pitch
and yaw calibrations for the OSEMs of SRM |
   |
5467
|
Mon Sep 19 18:05:27 2011 |
rana | Update | SUS | Summary screen |
|
|