  8671   Tue Jun 4 16:04:34 2013 AnnalisaUpdateLSCALS-TRY_OUT needs anti-whitening

    

       
            
  
  8672   Tue Jun 4 17:28:09 2013 AnnalisaUpdateLSCC1:ALS-TRY_OUT filter and green progress [Annalisa, Gautam, Rana]
I made the anti-whitening filter
for the C1:ALS-TRY_OUT channel.
 green.JPGQUAD1_1054358327.mp4 
  8674   Tue Jun 4 21:50:23 2013 AnnalisaUpdateLSCC1:ALS-TRY_OUT filter and green progress 
 [Annalisa, Gautam]
 The green beam alignment has
  
  8679   Wed Jun 5 14:43:42 2013 AnnalisaUpdateLSCALS-TRY_OUT DQ channels

    

       
            
  
  8680   Wed Jun 5 15:03:42 2013 AnnalisaUpdateLSCC1:ALS-TRY_OUT filter and green progress

    

       
            
 faraday_rejected_beam.JPG 
  8691   Sat Jun 8 00:24:11 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching[Annalisa, Nic]
After connecting the PD with the
reflection from the arm  to the PDH
  
  8692   Mon Jun 10 21:39:26 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching 
Still no good locking! 
  
  8695   Wed Jun 12 01:56:58 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching 
 For the mode matching calculation
I was using the ETMY focal length that I
 waistVaryingLensPos.pdfgreen.JPGModeMatchingY.pdf 
  8696   Wed Jun 12 22:48:10 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matchingAfter restoring alignment I could see again
strong 00 flashes (about 250-300 counts on
ALS-TRY). So I locked the arm with IR and
  
  8699   Thu Jun 13 10:57:36 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching> > Hmmm.  You seem to be saying that more
light is reflected than is injected. Is this
a units problem? Or was some IR on the power
  
  8704   Thu Jun 13 23:28:40 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching

    

       
            
  
  8715   Mon Jun 17 23:53:03 2013 AnnalisaUpdateGreen LockingY arm locked on green!!Y
arm locked on green carrier in 00 mode!
It
locked at almost 280 cts, and the transmitted
  
  8734   Thu Jun 20 17:47:44 2013 AnnalisaConfigurationSUSETMY oplev servo[Jenne, Annalisa]
The ETMY Oplev servo didn't work
properly, when it was activated the ETMY
  
  8749   Tue Jun 25 23:49:04 2013 AnnalisaUpdateSUSETMY OplevI had some problem with the Oplev Servo
today. I was working at the mode matching
fine tuning and I left the Oplev servo enabled
  
  8751   Wed Jun 26 00:15:51 2013 AnnalisaUpdateGreen LockingETMY - green locking and beat note setup[Koji, Annalisa]
Alignment improving

    The alignment of the green
  
  8768   Thu Jun 27 17:41:08 2013 AnnalisaUpdateGreen LockingETMY -beat note found! 
 Y
 beat_note.JPG 
  8792   Wed Jul 3 01:49:46 2013 AnnalisaUpdateGreen LockingALS servo configuration[Koji, Annalisa, Manasa]
Today we worked on the ALS servo
stabilization for the Y arm.
 ALSALS_calibrated 
  8793   Wed Jul 3 03:06:29 2013 AnnalisaUpdateGreen LockingALS servo configuration 
I realized that I cannot open the
attached plots. I'll fix them tomorrow.
  
  8819   Wed Jul 10 02:28:04 2013 AnnalisaUpdateGreen LockingBeat notes lost![Manasa, Jenne, Annalisa]
I was going to find the beat note
to start the cavity scan, but I couldn't.
  
  8821   Wed Jul 10 11:44:02 2013 AnnalisaUpdateGreen LockingY beat note found!I found the beat note for the Y arm. Nothing
was changed with respect to yesterday night,
but the beat is back!
  
  8831   Thu Jul 11 14:38:38 2013 AnnalisaUpdateGreen LockingY arm cavity scanYesterday I did a cavity scan with IR while
holding the Yarm with green.
ALS
 IRlocked_res_mot_0710.pdfArmScanN5.pngCavityScanETMYmis 
  8842   Sat Jul 13 03:27:20 2013 AnnalisaUpdateGreen LockingY arm caity scanI started doing a scan of the Y arm cavity
with IR with ALS enabled.
ALS
 PowerSpectrum0712ScanCavityAligned.pdfScanCavityMisPitch.pdfScanCavityMisYaw.pdf 
  8844   Sun Jul 14 18:19:00 2013 AnnalisaUpdateGreen LockingArm cavity scanYesterday evening Nic and me were in the
lab. The Mode Cleaner was unlocked, but after
many attempt we could fix it and we did many
  
  8886   Mon Jul 22 03:09:51 2013 AnnalisaUpdateGreen LockingY Arm cavity scanYesterday and today I was in the lab doing
many cavity scan.
First I did many measurement with
 Screenshot-scan3_0722.pdf_-_Adobe_Reader.png 
  8910   Tue Jul 23 19:37:08 2013 AnnalisaUpdateendtable upgradeEnd table picture

    

       
            
 IMG950073.jpgIMG950072.jpg 
  8930   Sun Jul 28 19:39:04 2013 AnnalisaUpdateendtable upgradePicture Yend table picture updated on the wiki
page
  
  8931   Sun Jul 28 20:13:41 2013 AnnalisaUpdateGreen LockingY Phase tracker calibrationI did a calibration measurement for the
Y part of the BeatBox using a Marconi. This
is in order to get a more accurate calibration
 YbeatBox_Calibration.pdf 
  14041   Fri Jul 6 12:12:09 2018 AnnalisaConfigurationThermal CompensationThermal compensation setupI tried to put together a rudimentary heater
setup. 

As a heating element, I used the
 IMG_1887.jpgIMG_1884.jpgIMG_1883.jpgIR20180706_0358_labels.png 
  14043   Sat Jul 7 19:50:38 2018 AnnalisaConfigurationThermal CompensationStudy about the Thermal projection setup and its effect on the cavityI made some simulation to study the change
that the heater setup can induce on the Radius
of Curvature of the ETM.
 6x 
  14050   Tue Jul 10 23:44:23 2018 AnnalisaConfigurationThermal CompensationHeater setup assembly[Annalisa, Koji]

Today both the heater and the reflector
were delivered, and we set down the setup
 8x 
  14071   Fri Jul 13 23:39:46 2018 AnnalisaConfigurationThermal CompensationThermal compensation setup - power supply[Annalisa, Rana]

In order to power the heater setup
to be installed in the ETMY chamber,
 IMG_2012.jpgIMG_2013.jpg20180713_213818.jpg 
  14081   Wed Jul 18 03:14:48 2018 AnnalisaUpdateGeneralVent 80 recovery[Gautam, Johannes, Koji, Annalisa]

Tonight we increased the power
of the PSL laser and we achieved the lock
  
  8801   Thu Jul 4 01:09:33 2013 Annalisa, KojiUpdateLSCPRMI locked with REFL165Summary:
-
The new REFL165 PD was installed on the AP
 130703_PRMI.pdfScreenshot.png 
  14062   Fri Jul 13 00:15:13 2018 Annalisa, TerraConfigurationAUXY arm cavity scan [Annalisa, Terra, Koji, Gautam]

Summary: We
find a configuration for arm scans which
 IMG_6492.JPGIMG_6494.JPG 
  14078   Tue Jul 17 17:37:46 2018 Annalisa, TerraConfigurationThermal CompensationHeaters installationSummary

We
installed two heaters setup on the ETMY bench
in order to try inducing some radius of curvature
 6x 
  14086   Thu Jul 19 04:44:09 2018 Annalisa, TerraSummaryThermal Compensationfrequency shift observed with heating!Annalisa, Gautum, Koji, Terra

Summary: with
the reflector setup, we measured a frequency
 scanning_fine_2018-07-19-07-32-08_parsed.pdfscanning_fine_2018-07-19-06-57-47_parsed.pdfYscan_scanning_parsed_2am.txt.pdf 
  13703   Mon Mar 26 10:15:20 2018 ArijitUpdateIOOPMC and IMC re-locked[Gautam, Arijit]

PMC and IMC re-aligned and re-locked.
Both cavities are staying locked. Arm cavities
  
  13788   Wed Apr 25 17:44:39 2018 ArnoldUpdatePEMPEM Anti-Alias wiring

 
  
  12621   Wed Nov 16 17:07:12 2016 AshleyUpdateGeneralPreliminary Microphone DataI am currently looking at the acoustic
noise around both arms to see if there are
any frequencies from machinery around the
 first_PSD_12kHz.pdfIMG_0171.JPG 
  12738   Thu Jan 19 10:21:54 2017 AshleyUpdateGeneralPreliminary Microphone DataBrief Summary:
I am currently looking at the acoustic
noise around both arms to see if there are
 xend_psd.pngxblrms.pngIMG_3734.JPG 
  12826   Mon Feb 13 17:39:45 2017 AshleyUpdateGeneralPreliminary Microphone Data Update
Problems that have occurred since
my last post: All of the sudden, I was getting
very strange data that was very quiet and
 figure_1.pngx_and_y_blrms_03.pngxblrms_median.png 
  7589   Mon Oct 22 20:44:49 2012 AyakaUpdateAdaptive Filteringmicrophone noiseI will do some experiments on acoustic
noise canceling during my stay.
Now I am planning to cancel acoustic
 mic_noise2.png 
  7596   Tue Oct 23 10:24:42 2012 AyakaUpdateAdaptive Filteringmicrophone noise

    

       
            
  
  7607   Wed Oct 24 14:15:34 2012 AyakaUpdateAdaptive Filteringmicrophone noisePrevious results
I am measuring the noise level of
the microphones. The circuit does not seems
 mic_open.pngmic_noise.png 
  7621   Thu Oct 25 09:53:23 2012 AyakaUpdateAdaptive Filteringmicrophone noise

    

       
            
  
  7633   Fri Oct 26 18:25:02 2012 AyakaUpdateAdaptive FilteringMicrophone noise again[Raji, Ayaka]
Thanks to Den, power supplies for
microphone circuit are changed.
 mic_noise.png 
  7636   Mon Oct 29 08:41:22 2012 AyakaUpdateAdaptive FilteringMicrophone noise again

    

       
            
  
  7672   Mon Nov 5 20:37:01 2012 AyakaUpdateWienerFilteringPlay with wiener filtering I am trying to find what limits the
reduction rate with wiener filtering.
I did some calculations below:
 estimate.pngWfilter_notch.png 
  7688   Thu Nov 8 10:11:58 2012 AyakaUpdateWienerFilteringPlay with wiener filteringI will attach a document which describes
how the noise affect the wiener filter and
the noise cancellation ratio.
 document.pdfestimate.pngR_model.png 
  7702   Tue Nov 13 00:28:10 2012 AyakaUpdateIOOMC locked, spots centered[Rana, Ayaka, Jenne]
We aligned the REFL beam to the center
of PD.
 spot1112.pngDSC_4902.JPGDSC_4904.JPG 
ELOG V3.1.3-