  16249   Fri Jul 16 16:26:50 2021 gautamUpdateComputersDocker installed on nodusI wanted to try hosting some docker images
on a "private" server, so I installed
Docker on nodus following the instructions
  
  16248   Thu Jul 15 14:25:48 2021 PacoUpdateLSCCM board[gautam, paco]

We tested the CM board by implementing
the high bandwidth IR lock (single arm).
 high_BW_TFs.pdf 
  16247   Wed Jul 14 20:42:04 2021 gautamUpdateLSCLocking[paco, gautam]

we decided to give the PRFPMI lock
a go early-ish. Summary of findings today
  
  16246   Wed Jul 14 19:21:44 2021 KojiUpdateGeneralBrrrJordan reported on Jun 18, 2021:

"HVAC tech came today, and replaced
  
  16245   Wed Jul 14 16:19:44 2021 gautamUpdateGeneralBrrrSince the repair work, the temperature
is significantly cooler. Surprisingly, even
at the vertex (to be more specific, inside
 rmTemp.pdf 
  16244   Mon Jul 12 18:06:25 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyI edited /cvs/cds/caltech/target/c1auxey1/ETMYaux.db
(after creating a backup) and added the spare
coil driver channels.
  
  16243   Fri Jul 9 18:35:32 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyFollowing Koji's channel list review,
we made changes to the
wiring spreadsheet.
  
  16242   Fri Jul 9 15:39:08 2021 AnchalSummaryALSSingle Arm Actuation Calibration with IR ALS Beat [Correction]I did this analysis again by just doing
demodulation go 5s time segments of the 60s
excitation signal. The major difference is
 ITMX_calibration_With_ALS_Beat.pdf 
  16241   Thu Jul 8 11:20:38 2021 Anchal, Paco, GautamSummaryLSCPRFPMI locking attemptsLast night Gautam walked us through the
algorithm used to lock PRFPMI. We tried it
several times with the PSL HEPA filter off
  
  16240   Tue Jul 6 17:40:32 2021 KojiSummaryGeneralLab cleaningWe held the lab cleaning for the
first time since the campus reopening (Attachment
1).
 7x 
  16239   Tue Jul 6 16:35:04 2021 Anchal, Paco, GautamUpdateIOORestored MCWe found that megatron is unable to properly
run scripts/MC/WFS/mcwfsoff and scripts/MC/WFS/mcwfson
scripts. It fails cdsutils commands due to
  
  16238   Tue Jul 6 10:47:07 2021 Paco, AnchalUpdateIOORestored MCMC was unlocked and struggling to recover
this morning due to misguided WFS offsets.
In order to recover from this kind of issue,
  
  16237   Fri Jul 2 12:42:56 2021 Anchal, Paco, GautamSummaryLSCsnap file changed for MICHWe corrected the MICH locking snap file
C1configure_MI.req and saved an updated C1configure_MI.snap.
Now the 'Restore MICH' script in
  
  16236   Thu Jul 1 16:55:21 2021 AnchalSummaryOptical LeversFixed Centeringoptical levers PRMThis was a mistake. When arms are locked,
PRM is misaligned by setting -800 offset
in PIT dof of PRM. The oplev is set to function
  
  16235   Thu Jul 1 16:45:25 2021 YehonathanUpdateBHDSOS assemblyThe bonding test passed - the weight still
hangs from the dumbell. Unfortunately, I
broke the bond trying to release the assembly
  
  16234   Thu Jul 1 11:37:50 2021 PacoUpdateGeneralrestarted c0rgaPhysically rebooted c0rga workstation after
failing to ssh into it (even as it was able
to ping into it...) the RGA seems to be off
  
  16233   Thu Jul 1 10:34:51 2021 Paco, AnchalSummaryLSCETMY QPD fixedPaco worked on alignign the beam splitter
to get light on the ETMY QPD and was successful
in centering it without any other changes
  
  16232   Wed Jun 30 18:44:11 2021 AnchalSummaryLSCTried fixing ETMY QPDI worked in Yend station, trying to get
the ETMY QPD to work properly. When I started,
only one (quadrant #3) of the 4 quadrants
  
  16231   Wed Jun 30 15:31:35 2021 AnchalSummaryOptical LeversCentered optical levers on ITMY, BS, PRM and ETMYWhen both arms were locked, we found that
ITMY optical lever was very off-center. This
seems to have happened after the c1susaux
  
  16230   Wed Jun 30 14:09:26 2021 Ian MacMillanUpdateCDSSUS simPlant modelI have looked at my code from the previous
plot of the transfer function and realized
that there is a slight error that must be
 SingleSusPlantTF.pdfPlant_TF_Test.zip 
  16229   Tue Jun 29 20:45:52 2021 YehonathanUpdateBHDSOS assemblyI glued another batch of 6 magnet+dumbell
assemblies. I will take a look at them under
the microscope once they are cured.
 20210629_135736.jpg20210629_135746.jpg 
  16228   Tue Jun 29 17:42:06 2021 Anchal, Paco, GautamSummaryLSCMICH locking tutorial with GautamToday we went through LSC locking mechanics
with Gautam and as a "Hello World"
example, worked on locking michelson cavity.
  
  16227   Mon Jun 28 12:35:19 2021 YehonathanUpdateBHDSOS assemblyOn Thursday, I glued another set of 6 dumbells+magnets
using the same method as before. I made sure
that dumbells are pressed onto the magnets.
 toomuchglue1.pngtoomuchglue2.pngdirtydumbell.pngcleandumbell.pngassembly_on_metalbracket.png 
  16226   Fri Jun 25 19:14:45 2021 JonUpdateEquipment loanZurich Instruments analyzerI returned the Zurich Instruments analyzer
I borrowed some time ago to test out at home.
It is sitting on first table across from
 ZI.JPG 
  16225   Fri Jun 25 14:06:10 2021 JonUpdateCDSFront-End Assembly and TestingSummary

Here is the final
summary (from me) of where things stand with
the new front-end systems. With Anchal and
 test_stand.JPG 
  16224   Thu Jun 24 17:32:52 2021 Ian MacMillanUpdateCDSFront-End Assembly and TestingAnchal and I ran tests on the two systems
(C1-SUS2 and C1-BHD). Attached are the results
and the code and data to recreate them.
 C1-SU2_Channel_Responses.pdfC1-BHD_Channel_Responses.pdfCDS_Channel_Test.zip 
  16223   Thu Jun 24 16:40:37 2021 KojiUpdateSUSMC lock acquired back again[Koji, Anchal]

The issue
of the PD output was that the PD whitened
 P_20210624_163641_1.jpg 
  16222   Wed Jun 23 09:05:02 2021 AnchalUpdateSUSMC lock acquired back againMC was unable to acquire lock because the
WFS offsets were cleared to zero at some
point and because of that MC was very misaligned
  
  16221   Tue Jun 22 17:05:26 2021 YehonathanUpdateBHDSOS assemblyAccording to the schematics,
the distance between the original EQ tap
holes is 0.5". Given that the original
  
  16220   Tue Jun 22 16:53:01 2021 Ian MacMillanUpdateCDSFront-End Assembly and TestingThe channels on both the C1BHD and C1SUS2
seem to be frozen: they arent updating and
are holding one value. To fix this Anchal
  
  16219   Tue Jun 22 16:52:28 2021 PacoUpdateSUSADC/Slow channels issuesAfter sliding the alignment bias around
and browsing through elog while searching
for "stuck" we concluded the ITMX
 shake_and_damp.png 
  16218   Tue Jun 22 11:56:16 2021 Anchal, PacoUpdateSUSADC/Slow channels issuesWe checked back in time to see how the
BS and PRM OSEM slow channels are zero. It
was clear that they became zero when we worked
 CDS_FE_Status.png 
  16217   Mon Jun 21 17:15:49 2021 Ian MacMillanUpdateCDSCDS UpgradeAnchal and I wrote a script (Attachment
1) that will test the ADC and DAC connections
with inputs on the INMON
 DAC2ADC_Test.py 
  16216   Fri Jun 18 23:53:08 2021 KojiUpdateBHDSOS assemblyThen, can we replace the four small EQ
stops at the bottom (barrel surface) with
two 1/4-20 EQ stops? This will require drilling
  
  16215   Fri Jun 18 19:02:00 2021 YehonathanUpdateBHDSOS assemblyToday I glued some magnets to dumbells.

First, I took 6 magnets (the maximum
I can glue in one go) and divided them into
 20210618_115017.jpgUntitled_2.png20210618_160041_HDR.jpg 
  16214   Fri Jun 18 14:53:37 2021 AnchalSummaryPEMTemperature sensor network proposalI propose we set up a temperature sensor
network as described in attachment 1.

Here there are two types of units:
 40mTempSensors.pdf 
  16213   Fri Jun 18 10:07:23 2021 Anchal, PacoSummaryAUXXend Green Laser PDH OLTF with coherenceWe did the measurement of OLTF for Xend
green laser PDH loop with excitation added
at control point using a SR560 as shown in
 XEND_PDH_OLTF_with_Coherence.pdfBeta_Amp.pdf 
  16212   Thu Jun 17 22:25:38 2021 KojiUpdateSUSNew electronics: Sat Amp / Coil DriversIt is a belated report: We received 5 more
sat amps on June 4th. (I said 7 more but
it was 6 more) So we still have one more
 P_20210604_231028.jpeg 
  16211   Thu Jun 17 22:19:12 2021 KojiUpdateElectronics25 HAM-A coil driver units delivered25 HAM-A coil driver units
were fabricated by Todd and I've transported
them to the 40m.
 P_20210617_195811.jpg 
  16210   Thu Jun 17 16:37:23 2021 Anchal, PacoUpdateSUSc1susaux computer rebootedJon suggested to reboot the acromag chassis,
then the computer, and we did this without
success. Then, Koji suggested we try running
  
  16209   Thu Jun 17 11:45:42 2021 Anchal, PacoUpdateSUSMC1 Gave trouble againTL;DR

MC1 LL Sensor showed signs of fluctuating
large offsets. We tried to find the issue
 SummaryScreenShot.pngMC1_LL_SENSOR_DEAD.png 
  16208   Thu Jun 17 11:19:37 2021 Ian MacMillanUpdateCDSCDS UpgradeJon and I tested the ADC and DAC cards
in both of the systems on the test stand.
We had to swap out an 18-bit DAC for a 16-bit
  
  16207   Wed Jun 16 20:32:39 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyI installed 2 additional isolators in the
Acromag chassis. I set all the input channels
to PNP. I ran the digital inputs (EnableMon
  
  16206   Wed Jun 16 19:34:18 2021 KojiUpdateGeneralHVACI made a flow sensor with a stick and tissue
paper to check the airflow.

- The HVAC indicator was not lit,
 HVAC_Power.jpegSouth_Arm.jpegSouth_End_Tenperature.jpegVertex.jpegEast_Arm.jpeg 
  16205   Wed Jun 16 17:24:29 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyI updated the wiring diagram according
to Koji's suggestion. According to the
 Optical_isolator_Wiring.pdf 
  16204   Wed Jun 16 13:20:19 2021 Anchal, PacoSummaryCamerasMon 7 in Control Room ReplacedWe replaced the Mon 7 with an LCD monitor
from back bench. It is fed the analog signal
from BNC converted into VGS with a converter
 IMG_20210616_083810.jpg 
  16203   Tue Jun 15 21:48:55 2021 KojiUpdateCDSOpto-isolator for c1auxeyIf my understanding is correct, the (photo
receiving) NPN transistor of the optocoupler
is energized through the acromag. The LED
 Acromag_RTS_BI_config.jpg 
  16202   Tue Jun 15 15:26:43 2021 Anchal, PacoSummaryAUXXend Green Laser PDH OLTF measurement loop algebra, excitation at control pointAttachment 1 shows the case when excitation
is sent at control point i.e. the PZT output.
As before, free running laser noise 
 AuxPDHloop.pdf 
  16201   Tue Jun 15 11:46:40 2021 Ian MacMillanUpdateCDSSUS simPlant modelI have added more degrees of freedom. The
model includes x, y, z, pitch, yaw, roll
and is controlled by a matrix of transfer
 x1sup_isolated-6-15-v1.pdfC1_SUS_SINGLE_PLANT-6-15-v1.pdf 
  16200   Mon Jun 14 18:57:49 2021 AnchalUpdateAUXXend is unbearably hot. Green laser is loosing lock in 10's of secondsWorking in Xend with mask on has become
unbearable. It is very hot there and I would
really like if we fix this issue.
 XAUX_PDH_Err_In_ASD.pdfXAUX_PZT_Out_Mon_ASD.pdf 