  12467   Fri Sep 2 21:15:53 2016 gautamUpdateSUSITMX and ETMX preemptive table levelingThe ITMX table had relaxed overnight into
a slightly misaligned state overnight - since
the ITMX table holds PR2 and hence can affect
  
  12471   Tue Sep 6 00:14:14 2016 gautamUpdateElectronicsSatellite Amplifier 




 osempdComparison.pdf 
  12474   Tue Sep 6 20:45:14 2016 gautamUpdateSUSX arm test masses back in chamber[Teng, Johannes,
Lydia, gautam]


The
 IMG_3137.JPGIMG_3143.JPGIMG_3142.JPGIMG_3148.JPG 
  12475   Tue Sep 6 20:52:42 2016 gautamUpdateSUSOSEM issues



The
 P9060254.JPG 
  12476   Wed Sep 7 17:23:26 2016 gautamUpdateSUSPRM LR fixed for now[johannes, gautam]


We took the heavy door
off in the morning with Steve's help
The
 IMG_3208.JPGIMG_3211.JPG 
  12478   Thu Sep 8 22:12:36 2016 gautamUpdateSUSX arm in place, locked to green, IR flashes visibleDetailed elog to follow but summary of
todays activities:


ITMX and ETMX are back
  
  12480   Fri Sep 9 17:50:02 2016 gautamUpdateSUSHeavy doors on BS-PRM, ETMY chambers[steve, teng, johannes, lydia, gautam]


we set about doing some
final checks on the Y arm while Johannes
  
  12526   Fri Sep 30 19:53:07 2016 gautamUpdateendtable upgradeX end IR pickoff fiber coupled[johannes, gautam]

Today we re-installed the fiber
coupler on the X-endtable to couple some
  
  12532   Wed Oct 5 16:28:10 2016 gautamUpdateendtable upgradeEX laser power monitor PD installedI installed a 10% BS to pick off some of
the light going to the IR fiber, and have
added a Thorlabs PDA55 PD to the EX table
  
  12533   Wed Oct 5 19:10:04 2016 gautamUpdateGeneralArm loss measurement review[ericq,gautam]

There are multiple methods by which
the arm loss can be measured, including,
  
  12534   Wed Oct 5 19:43:13 2016 gautamSummaryGeneralVent reviewThis elog is meant to review some of the
important changes made during the vent this
summer - please add to this if I've forgotten
  
  12542   Mon Oct 10 11:48:05 2016 gautamUpdateCDSPower-cycled c1susaux, realigned PMC, spots centered on WFS1 and WFS2[Koji, Gautam]

We did the following today morning:


I re-aligned the PMC -
  
  12545   Mon Oct 10 18:34:52 2016 gautamUpdateGeneralPZT OM MirrorsI did a quick survey of the drive electronics
for the PZT OM mirrors today. The hope is
that we can correct for the clipping observed
  
  12551   Tue Oct 11 13:30:49 2016 gautamUpdateSUSPRM LR problematic againPerhaps the problem is electrical? The
attached plot shows a downward trend for
the LR sensor output over the past 20 days
 PRM_LR_decay.png 
  12552   Wed Oct 12 13:34:28 2016 gautamUpdateSUSPRM LR problematic againLooks like what were PRM problems are now
seen in the SRM channels, while PRM itself
seems well behaved. This supports the hypothesis
 08.png 
  12560   Thu Oct 13 19:28:14 2016 gautamUpdateGeneralin-air alignmentI did the following today to prepare for
taking the doors off tomorrow.


Locked MC at low power

low
  
  12561   Fri Oct 14 10:31:53 2016 gautamUpdateGeneraldoors are off ITMY and BS/PRM chambers[steve,ericq,gautam]

We re-checked IMC locking, arm
alignments (we were able to lock and dither
  
  12563   Fri Oct 14 18:33:55 2016 gautamUpdateGeneralAS clipping investigations[steve,ericq,gautam]

In the afternoon, we took the heavy
door off the OMC chamber as well, such that
 7x 
  12566   Mon Oct 17 22:45:16 2016 gautamUpdateGeneralAS beam centered on all OMs[ericq, lydia, gautam]

IMC realignment, Arm
dither alignment
 7x 
  12568   Tue Oct 18 18:56:57 2016 gautamUpdateGeneralOM5 rotated to bypass OMC, green scatter is from window to PSL table[ericq, lydia, gautam]


We started today by checking
leveling of ITMY table, all was okay on that
 OMCchamber.pdfgreenGhosts.JPGIMG_3322.JPGIMG_3326.JPG 
  12571   Wed Oct 19 16:41:55 2016 gautamUpdateGeneralHeavy doors back on[ericq, lydia, steve, gautam]


We aligned the arms, and
centered the in-air AS beam onto the PDs
 8x 
  12576   Fri Oct 21 02:06:20 2016 gautamUpdateGeneralIFO recoveryThe pressure on the newly installed gauge
on the X arm was 6E-5 torr when I came in
today evening, so I decided to start the
  
  12578   Mon Oct 24 11:39:13 2016 gautamUpdateGeneralALS recoveredI worked on recovering ALS today. Alignments
had drifted sufficiently that I had to to
the alignment on the PSL table onto the green
 ALSOutOfLoop20161024.pdfXendPDHOLTF20161024.pdf 
  12579   Tue Oct 25 15:56:11 2016 gautamUpdateGeneralPRFPMI locked, arms loss improved[ericq,gautam]

Given that most of the post vent
recovery tasks were done, and that the ALS
 PRFPMIlock_25Oct2016.pdfITMYwoes.png 
  12583   Thu Oct 27 12:06:39 2016 gautamUpdateGeneralPRFPMI locked, arms loss improved


 PRG.pdf 
  12586   Fri Oct 28 01:44:48 2016 gautamUpdateGeneralPRFPMI model vs data studiesFollowing Koji's suggestion, I decided
to investigate the relation between my Finesse
model and the measured data.
 6x 
  12587   Fri Oct 28 15:46:29 2016 gautamSummaryLSCX/Y green beat mode overlap measurement redoneI've been meaning to do this analysis
ever since putting in the new laser at the
X-end, and finally got down to getting all
  
  12592   Wed Nov 2 22:56:45 2016 gautamUpdateCDSc1pem revampedinstalling the BLRMS 2k blocks turned out
to be quite non-trivial due to a whole host
of CDS issues that had to be debugged, but
  
  12594   Thu Nov 3 11:33:24 2016 gautamUpdateGeneralpower glitch - recoveryI did the following:


Hard reboots for fb, megatron,
and all the frontends, in that order
Checked
  
  12595   Thu Nov 3 12:38:42 2016 gautamUpdateCDSc1pem revampedA number of changes were made to C1PEM
and some library parts. Recall that the motivation
was to add BLRMS channels for all our suspension
 BLRMSresp.pdf 
  12596   Thu Nov 3 12:40:10 2016 gautamUpdateGeneral projector light bulb is outThe projector failed just now with a pretty
loud 'pop' sound - I've never
been present when the lamp goes out, so I
  
  12602   Mon Nov 7 16:05:55 2016 gautamUpdateSUSPRM Sat. Box. DebuggingShort summary of my Sat. Box. debugging
activities over the last few days. Recall
that the SRM Sat. Box has been plugged into
 D961289-B2.pdfPRMSatBoxtest.png 
  12603   Mon Nov 7 17:24:12 2016 gautamUpdateGreen LockingGreen beat setup on PSL tableI've been trying to understand the
green beat setup on the PSL table to see
if I can explain the abysmal mode-matching
 CurrentX.pdfCurrentY.pdfProposedShift_copy.pdf 
  12606   Tue Nov 8 11:54:38 2016 gautamUpdateSUSPRM Sat. Box. looks to be fixedLooks like the PRM Sat. Box is now okay,
no evidence of the kind of glitchy behaviour
we are used to seeing in any of the 5 channels.
  
  12609   Wed Nov 9 23:21:44 2016 gautamUpdateGreen LockingGreen beat setup on PSL tableI tried to realize an improvement in the
mode matching onto the BBPDs by moving the
lens mentioned in the previous elog in this
  
  12610   Thu Nov 10 19:02:03 2016 gautamUpdateCDSEPICS Freezes are backI've been noticing over the last couple
of days that the EPICS freezes are occurring
more frequently again. Attached is an instance
 epicsFreezesBack.png 
  12611   Sat Nov 12 01:09:56 2016 gautamUpdateLSCRecovering DRMI lockingNow that we have all Satellite boxes working
again, I've been working on trying to
recover the DRMI 1f locking over the last
  
  12613   Mon Nov 14 14:21:06 2016 gautamSummaryCDSReplacing DIMM on OptimusI replaced the suspected faulty DIMM earlier
today (actually I replaced a pair of them
as per the Sun Fire X4600 manual). I did
  
  12616   Tue Nov 15 19:22:17 2016 gautamUpdateGeneralhousekeepingPRM and SRM sat. boxes have been switched
for some time now - but the PRM sat. box
has one channel with a different
  
  12619   Wed Nov 16 03:10:01 2016 gautamUpdateLSCDRMI locked on 1f and 3f signalsAfter much trial and error with whitening
gains, demod phases and overall loop gains,
I was finally able to lock the DRMI
  
  12623   Thu Nov 17 15:17:16 2016 gautamUpdateIMCMCL FeedbackAs a starting point, I was looking at some
of the old elogs and tried turning on the
MCL feedback path with the existing control
 MCLerror.pdfMCLtest.pngYarmCtrl.pdf 
  12627   Fri Nov 18 17:52:42 2016 gautamUpdatePSLFSS Slow control -> Python, WFS re-engaged[yinzi, craig, gautam]

Yinzi had translated the Perl PID
script used to implement the discrete-time
  
  12630   Mon Nov 21 14:02:32 2016 gautamUpdateLSCDRMI locked on 3f signals, arms held on ALSOver the weekend, I was successful in locking
the DRMI with the arms held on ALS. The locks
were fairly robust, lasting order of minutes,
 DRMIArms_Nov20.pdf 
  12631   Mon Nov 21 15:34:24 2016 gautamUpdateCOCRC folding mirrors - updated specs
p.p1 {margin:
0.0px 0.0px 0.0px 0.0px; font: 12.0px 'Helvetica
Neue'; -webkit-text-stroke: #000000}
li.li1
 Recycling_Mirrors_Specs_Nov2016.pdf 
  12635   Wed Nov 23 01:13:02 2016 gautamUpdateIMCMCL FeedbackI wanted to get a clearer idea of the FSS
servo and the various boxes in the signal
chain and so Lydia and I poked around the
 MCL_plant.pdfOLG.pdfMC_armSpectra_X.pdfMC_armSpectra_Y.pdf 
  12638   Wed Nov 23 16:21:02 2016 gautamUpdateLSCITMY UL glitches are back 




 ITMYproblemsBack.png 
  12643   Mon Nov 28 10:27:13 2016 gautamUpdateSUSITMY UL glitches are backI left the tester box plugged in from Thursday
night to Sunday afternoon, and in this period,
the glitches still appeared in (and only
 ITMY_satboxSpectra.pdfITMY_UL_testerBox.png 
  12648   Wed Nov 30 01:47:56 2016 gautamUpdateLSCSuspension woesShort summary:


Looks
 IMCwoes.png 
  12652   Wed Nov 30 17:08:56 2016 gautamUpdateLSCBinary output breakout box removed[ericq, gautam]

To diagnose the glitches in OSEM
readouts, we
  
  12653   Thu Dec 1 02:19:13 2016 gautamUpdateLSCBinary output breakout box restoredAs we suspected, the binary breakout board
(D080478, no drawing available) is simply
a bunch of tracks printed on the PCB to route
 MC1_glitch_fast.pngITMY_testerGlitch.pngITMYsatbox.pngULcomparison.pdf 